UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

Similar documents
UNA 26h Stainless Steel Design. Installation Instructions Stainless Steel Steam Trap UNA 26h

Condensate Drain Valve AK 45. Original Installation Instructions English

GESTRA. GESTRA Steam Systems MK 25/2 MK 25/2S. Installation Instructions Steam Traps MK 25..., DN 40-50

UNA 23 UNA 25 UNA 26 UNA 27

UNA 23 UNA 25 UNA 26 UNA 27

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME

PA 46 PA 47 MPA 46 MPA 47

GESTRA DISCO Non-Return Valves RK 41, PN 16. Non-Return Valves PN 6/10/16 DN (½ 8") RK 41, PN 16. Application for liquids, gases, vapours.

Compact System NRGS 11-2 NRGS Original Installation Instructions English

GESTRA. GESTRA Steam Systems ZK 313 ASME. Installation Instructions Control Valve ZK 313 ASME

BB 1... BB 2... Installation and Maintenance Instructions Dual-Plate Check Valves BB 1..., BB 2...

Grey cast iron Fig. 600 Page 2. Forged steel High temperature steel Stainless steel Fig. 600/601 (Y) DN15-25 Page 4 DN40-50 Page 6

CONA Further components / Accessories

SCA Series Steel Inverted Bucket Steam Traps

Grey cast iron Fig. 610 Page 2. Forged steel Stainless steel Fig. 610/612 (Y) Page 4

BA 46 BA 46-ASME BA 47 BA 47-ASME BAE BAE ASME BAE BAE ASME

Grey cast iron SG iron Cast steel/ Forged steel High temperature steel Stainless steel Fig. 631 Page 2

M21Fi ISO Reduced Bore Firesafe API607 Ball Valve DN15 to DN150 Flanged PN40

Steam Trap MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Level Electrode NRG NRG NRG NRG

Forged steel Stainless steel Fig. 610/612 (Y) Page 2. Forged steel Fig. 616 Page 6

High temperature steel Fig. 600 Page 8. High temperature steel Fig. 600 Page 10. High temperature steel Fig. 600 Page 12

Grey cast iron SG iron Cast steel Forged steel High temperature steel Stainless steel Fig. 631 Page 2

M21Fi ISO Ball Valve DN15 to DN150

M21Hi ISO Reduced Bore Ball Valve DN15 to DN150 Flanged PN40

S and SF Series Cast Iron Inverted Bucket Steam Traps

High temperature steel Fig. 600 Page 8. High temperature steel Fig. 600 Page 10. High temperature steel Fig. 600 Page 12

Experience In Motion. Gestra Steam Solutions Catalog

M10F Ball Valve DN¼" to DN2½"

Forged steel Stainless steel Fig. 60A Page 2. Forged steel Stainless steel Fig. 61A Page 4. Forged steel Stainless steel Fig.

Grey cast iron SG iron Forged steel/ Cast steel Stainless steel Fig. 631 Page 2. High temperature steel Fig. 631 / Fig. 632 Page 8

NRG 16-12, NRG 17-12, NRG 19-12

Grey cast iron SG iron Forged steel/ Cast steel Stainless steel Fig. 631 Page 2. High temperature steel Fig. 631 / Fig. 632 Page 8

Forged steel Fig. 640/641 (Y) Page 6

MFP14, MFP14S and MFP14SS Automatic Pumps

M21Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN15 to DN150 Flanged PN40

GESTRA. Technical Information

CONA ANSI Further components / Accessories

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Forged steel High temperature steel Stainless steel Fig. 640/641 (Y) Page 2. High temperature steel Fig. 640/641 (Y) Page 6

ARI-Strainer. ARI-Strainer - Screen and supporting basket made of stainless steel. ARI-Strainer - Y-pattern with flanges

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

AWH ARMATUREN- WERK HALLE GMBH. Thermodynamic steam trap. Thermodynamic steam trap. Thermodynamic steam trap PN40. Thermodynamic steam trap PN63

FT47 SG Iron Ball Float Steam Traps (DN15 to DN50)

Technical information 2018

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

Forged steel High temperature steel Stainless steel BR 640 / BR 641 (Y) Page 2. with system connectors. Stainless steel BR 642 / BR 643 (Y) Page 4

ARI-Strainer. Strainer - Screen and supporting basket made of stainless steel. ARI-Strainer - Y-pattern with flanges

PV4 and PV6 Piston Valves

GESTRA. Technical Information

GESTRA Technical Information

M10Si ISO Ball Valve DN¼" to DN2½"

Pressure reducing valve Pressure reducing valve in straightway form DN

Conductivity Switch LRGS Original Installation Instructions English

GL Ludemann Y-Strainers

These installation and maintenance instructions must be read in full and completely understood before the installation!

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

APT10-2 Automatic Pump Trap

AN ISO 9001:2008 CERTIFIED COMPANY. Safety Valve

Pressure Reducing Valve Type 2114/2415

NRG Installation Instructions Level Probe Type NRG A Siebe Group Product 1

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

APT14 Automatic Pump Trap Installation and Maintenance Instructions

What's in a ball valve?

ARI-FABA -ANSI LongLife Stop valve with bellows seal

ARI-Check valve. ARI-Check valve, metallic sealing. ARI-Check valve - Straight through with flanges. ARI-Check valve - Straight through with flanges

Ball Valves in investment cast stainless 2-way

Masoneilan * Pressure Regulators Steam, Gas or Liquid Service Models 525 and 526

Float-operated condensate pump ARI Condensate pump (mechanical) Displacement: 16,5-20 litres. High temperature steel. Stainless steel.

CONA -control Monitoring system for steam traps

Excess pressure regulator Excess pressure regulator, straight through DN

K-BALL THREE PIECE HEAVY DUTY, REDUCED AND FULL BORE BALL VALVES SERIES 180

Kunkle Bailey 756 safety relief valve

Series MRK and MRM For nominal pressures up to 640 bar /class 4500 Automatic Recirculation Valve for pump protection

SERIES 270A HIGH SIDE FLOAT VALVES BULLETIN 270A-SB11-02 SERVICE BULLETIN

Stop check valves type SCA , SCA-SS Check valves type CHV , CHV-SS Technical leaflet REFRIGERATION AND AIR CONDITIONING

Spring Loaded Safety Valve. SiC 11/13/14

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

YARWAY FLOAT TRAPS SERIES 23000, 26000, 33000

Control Valve. 3-Piece 30, 60, or 1/8" Slotted Port. General Chemical. Industrial. Power INLINE BALLVALVE.COM

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

ARI-CHECKO -V / -D Check valve ARI-Check valve, metallic sealing

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

ARI-FABA LA Stop valve with bellows seal Free of maintenance stop valve with bellow seal - metallic sealing - long construction

Stop check valves, SCA-X Check valves, CHV-X

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

Strainer. ARI-Strainer. ARI-Strainer Y-pattern with flanges. ARI-Strainer Y-pattern with flanges. ARI-Strainer Y-pattern with butt weld ends

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Cast iron Nodular iron Cast steel BR 050 Page 2. Stainless steel BR 059 Page 2. Cast steel BR 080 Page 3

(ST-B1 / ST-B2 / ST-B3 / ST-B4) CAST IRON INVERTED BUCKET STEAM TRAP

Choice of body materials Cast iron, carbon steel, chrome moly, forged steel, stainless steel, bronze.

Hand Expansion Valves Built Stronger to Last Longer Sizes: 6mm (¼ ) to 305mm (4 )

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

VALFONTA SELF-ACTING PRESSURE REDUCING VALVE M1

Metso High Consistency Sampler Metso Nove H. Installation & Owner s Manual K10196 V1.1 EN

Installation and Maintenance Manual Duplex Pressure Powered Pump Package Unit with Insulation Jacket and Condensate Recovery Meter PPPPU-D

Check & stop valve, SCA-X Check valve, CHV-X

DN [ ] DN [ ] Functional data Media Cold and hot water, water with glycol up to max. 50% vol.

Shut-off Check valves and regulating valves for for Industrial Refrigeration

Transcription:

UNA 13 UNA 15 UNA 15 Stainless Steel Design Installation Instructions 810604-01 Steam Traps UNA 13, UNA 15 1

Contents Important Notes Page Use... 7 Safety note... 7 Danger... 7 Explanatory Notes Scope of supply... 8 Description... 8 Function... 8 Technical data... 9, 10 Corrosion resistance... 10 Sizing... 10 Installation UNA 13, UNA 15... 11 Flanged design... 11 Screwed-socket design... 11 Socket-weld design... 11 Butt-weld design... 12 Heat treatment of welds... 12 Change direction of flow... 12 Hand vent valve... 13 Float-lifting lever (accessory)... 13 Commissioning UNA 13, UNA 15... 13 Maintenance Clean trap... 14 Torques... 14 Spare Parts List Spare parts... 15 2

Capacity Chart Orifice 21 Orifice 13 Orifice 4 1 2 3 1 2 3 Orifice 14, DN 15-25, ½" - 1" Orifice 13, DN 15-25, ½" - 1" Orifice 21, DN 15-25, ½" - 1" Fig. 1 3

Parts Drawings B P A C D F O E G H N I M L G H J Fig. 2 K 4

Maintenance A L M N Fig. 3 L M N Fig. 4 5

Key A B C D Flow direction arrow Body Retainer Thermostatic capsule E Name plate F Hand vent valve G Plug H Gasket C 17 x 23 I Cover J K L M N O P Float-lifting lever Handle Control unit SIMPLEX Control unit SIMPLEX R Control unit DUPLEX Body gasket 77 x 67 x 1 (graphite/crni) Socket-head cap screw 6

Important Notes Use Use steam traps UNA 13 and UNA 15 only for discharge of condensate and liquids in pipes within the admissible pressure/temperature ratings. Check the chemical resistance and suitability of the steam trap for the desired application. Safety Note The steam trap may only be installed by qualified staff. Qualified staff are those persons who through adequate training in engineering, the use and application of equipment in accordance with regulations concerning steam systems, and first aid & accident prevention have achieved a recognised level of competence appropriate to the installation and commissioning of this device. Danger The steam trap is under pressure when the system is operating. When loosening flanged connections, plugs or the control unit hot water, steam, corrosive fluids or toxic gases may escape. This presents the risk of severe scalds and acid burns to the whole body or severe cases of poisoning. Before carrying out installation and maintenance work it is therefore essential to isolate and depressurize the trap. The trap becomes hot during operation. This presents the risk of severe burns to hands and arms. Before carrying out any installation or maintenance work make sure that the trap is cold. Sharp edges on internals present a danger of cuts to hands. Always wear industrial gloves when replacing the control unit. 7

Explanatory Notes Scope of Supply UNA 13 1 Steam trap type UNA 13 1 Installation manual UNA 15 1 Steam trap type UNA 15 1 Installation manual UNA 15 Stainless Steel Design 1 Steam trap type UNA 15 stainless steel design 1 Installation manual Description UNA 13, UNA 15 are ball float traps with rolling ball closing mechanisms. The steam traps work independently of back pressure, thus ensuring universal application. UNA 13, UNA 15 feature a body with bolted cover and a control unit. The control unit is freely accessible after removing the cover and can be replaced without taking the body out of the pipe. Three different control units are available: Level-dependent SIMPLEX control for cold condensates, level-dependent SIMPLEX R control with inner vent pipe for continuous air-venting and temperature-dependent DUPLEX control with automatic deaeration for saturated steam systems. suitable for large condensate flowrates asbestos-free body gasket (graphite/crni) horizontal or vertical installation according to position of cover Function The ball valve of the control unit is operated by the float as a function of the condensate level in the trap. The cross-sectional area (CSA) of the orifice dictates the max. flowrate when the valve is completely open. The max. differential pressure of the control unit is a function of the CSA of the orifice and the density of the fluid to be discharged. There are three different closing units (orifices) available which can also be retrofitted. Float traps equipped with control units DUPLEX enable automatic temperature-dependent deaeration of saturated steam systems during start-up and in continuous operation. 8

Explanatory Notes continued Technical Data Orifices (O) O 04, PMX 04 bar (060 psi) O 13, PMX 13 bar (185 psi) O 21, PMX 21 bar (305 psi) UNA 13 UNA 15 suitable suitable suitable suitable suitable Pressure/Temperature Rating UNA 13, grey cast iron, PN 16 Max. service pressure [barg] 16 13 PMA [psig] 230 185 Related temperature [ C] 120 300 TMA [ F] 248 572 Max. differential pressure (inlet pressure minus outlet pressure) PMX Orifice 4: 4 bar (58 psi) Orifice 13: 13 bar (185 psi) Pressure/Temperature Rating UNA 15, carbon steel, PN 25 Max. service pressure [barg] 25 21 13 PMA [psig] 363 305 185 Related temperature [ C] 120 225 400 TMA [ F] 248 437 752 Max. differential pressure Orifice 4: 4 bar (58 psi) (inlet pressure minus Orifice 13: 13 bar (185 psi) outlet pressure) PMX Orifice 21: 21 bar (305 psi) Pressure/Temperature Rating UNA 15, stainless steel, PN 25 Max. service pressure [barg] 20 16 14 PMA [psig] 290 232 203 Related temperature [ C] 100 200 300 TMA [ F] 212 392 572 Max. differential pressure Orifice 4: 4 bar (58 psi) (inlet pressure minus Orifice 13: 13 bar (185 psi) outlet pressure) PMX Orifice 21: 21 bar (305 psi) 9

Explanatory Notes continued Technical Data continued Materials Body UNA 13 Cover UNA 13 Body UNA 15 Cover UNA 15 Body UNA 15 stainless steel design Cover UNA 15 stainless steel design new EN-GJL-250 (EN-JL-1040) EN-GJL-250 (EN-JL-1040) GP 240 GH DIN reference old Grey cast iron GG 25 (0.6025) Grey cast iron GG 25 (0.6025) Forged steel C 22.8 (0.0460) Cast steel GS-C 25 (0.0619) Austenitic S.S. X6CrNiMoTi17122 (1.4571) Stainless steel G-X6CrNi189 (1.4308) Stainless steel Ball float X 6 CrNiMoTi 17122 (1.4571) Stainless steel Seat X 8 CrNiS 189 (1.4305) Stainless steel Valve ball X 5 CrNi 1810 (1.4301) Body gasket Graphite/CrNi Other internals Stainless steel * Physical and chemical properties comply with DIN grade. ASTM nearest equivalent grade is stated for guidance only. ASTM equivalent* A 126 CL.B A 126 CL.B A 105 (ASTM) A 216 WCB AISI 316 Ti A 351 CF 8 AISI 316 Ti AISI 303 A 182 F 304 10 Corrosion Resistance When used for its intended purpose the safe functioning of the steam trap will not be impaired by corrosion. Sizing The trap body must not be subjected to sharp increases in pressure. Welds and flanges of the trap are designed to withstand dynamic loading (bending and alternating stress). The dimensional allowances for corrosion reflect the latest state of technology.

Installation UNA 13, UNA 15 The steam trap can depending on its body design be installed in horizontal or vertical pipes with downward flow. Flanged Design 1. Take care of correct position of installation. The name plate E must always be on top. 2. Take care of flow direction. The flow arrow A is on the trap body. If necessary, change direction of flow. 3. Consider space required for opening trap. When the trap is installed a minimum space of 130 mm is required for removing cover I. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean seating surfaces of both flanges. 6. Install steam trap. Screwed-Socket Design 1. Take care of correct position of installation. The name plate E must always be on top. 2. Take care of flow direction. The flow arrow A is on the trap body. If necessary, change direction of flow. 3. Consider space required for opening trap. When the trap is installed a minimum space of 130 mm is required for removing cover I. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean threads of screwed sockets. 6. Install steam trap. Socket-Weld Design 1. Take care of correct position of installation. The name plate E must always be on top. 2. Take care of flow direction. The flow arrow A is on the trap body. If necessary, change direction of flow. 3. Consider space required for opening trap. When the trap is installed a minimum space of 130 mm is required for removing cover I. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean socket-weld ends. 6. Arc-weld trap only manually (welding process 111 and 141 in accordance with DIN EN 24063). 11

Installation continued Butt-Weld Design 1. Take care of correct position of installation. The name plate E must always be on top. 2. Take care of flow direction. The flow arrow A is on the trap body. If necessary, change direction of flow. 3. Consider space required for opening trap. When the trap is installed a minimum space of 130 mm is required for removing cover I. 4. Remove plastic plugs. They are only used as transit protection. 5. Clean butt-weld ends. 6. Arc-weld trap only manually (welding process 111 and 141 in accordance with DIN EN 24063) or use gas-welding process (welding process 3 in accordance with DIN EN 24063). Attention Only qualified welders certified e. g. according to DIN EN 287 may weld the steam trap into pressurized lines. Heat Treatment of Welds A subsequent heat treatment of the welds is not required. Change Flow Direction 1. Remove cover C from body B, Fig. 2. 2. Lever control unit L M N off its support using a screwdriver, Fig. 3. 3. Turn body so that arrow A points in the desired flow direction. 4. Position control unit on support and fix it by two sharp blows, Fig. 4. 5. Clean seating surfaces of body and cover. 6. Insert new gasket and reassemble body and cover. Tighten body screws in diagonally opposite pairs with a torque of 35 Nm. After commissioning retighten body screws. Tools Allen key size 8 to DIN 911L Screwdriver 5.5/125 mm to DIN 5265 Punch 120/10 mm to DIN 7250 Hammer 500 g to DIN 1041 12

Installation continued Hand Vent Valve 1. Remove plug G. 2. Insert gasket H, fit hand vent valve F in place and tighten with a torque of 75 Nm. 3. Close hand vent valve. Tools Spanner A. F. 17 mm to DIN 3113 form B Torque spanner 20 120 Nm to DIN ISO 6789 Float-Lifting Lever (Accessory) 1. Remove plug G. 2. Insert gasket H and fit float-lifting lever J in place. Install handle for float-lifting lever and keep it in the horizontal position. Tighten with a torque of 75 Nm. Tools Spanner A. F. 17 mm to DIN 3113 form B Torque spanner 20 120 Nm to DIN ISO 6789 Commissioning Make sure that all flanged connections, the hand vent valve and the float-lifting lever are firmly fixed to the trap, maintaining a tight, leakproof joint. 13

Maintenance GESTRA steam traps UNA 13, UNA 15 do not require any special maintenance. However, if used in new installations which have not been rinsed it may be necessary to check and clean the trap. Clean Steam Trap 1. Remove cover I from body B, Fig. 2. 2. Lever control unit L M N off its support using a screwdriver, Fig. 3. 3. Remove old body gasket O. 4. Clean body and internals. 5. Clean seating surfaces of body and cover. Insert new gasket O. 6. Position control unit on support and fix it by two sharp blows, Fig. 4. 7. Insert new gasket and reassemble body and cover. Tighten body screws in diagonally opposite pairs with a torque of 35 Nm. After commissioning retighten body screws. Tools Allen key size 8 to DIN 911L Screwdriver 5.5/125 mm to DIN 5265 Punch 120/10 mm to DIN 7250 Hammer 500 g to DIN 1041 Torques Item Trap type Torque [Nm] F G J UNA 13, UNA 15, UNA 15 stainless steel 75 P UNA 13, UNA 15 15 P UNA 15 stainless steel 15 All torques indicated in the table are based on 20 C room temperature. 14

Spare Parts List Spare Parts Item Designation Ref. no. UNA 13 H Gasket* A17x 23 560486 Ref. no. UNA 15 UNA 15 Stainless Steel 560486 012579 O Body gasket* (graphite/crni) 560493 560493 D Thermostatic capsule 5N2 560494 560494 N O Control unit Duplex, complete Orifice 4 Orifice 13 560410 560409 560410 560409 Orifice 21 560408 560408 M O Control unit Simplex R, complete Orifice 4 Orifice 13 560413 560412 560413 560412 Orifice 21 560411 560411 L O Control unit Simplex, complete Orifice 4 Orifice 13 560416 560415 560416 560415 Orifice 21 560414 560414 * Minimum purchasing quantity 20 pcs. ** Minimum purchasing quantity 10 pcs. Contact your local dealer for smaller quantities. 15

You can find our authorised agents around the world at: www.gestra.com GESTRA AG Münchener Straße 77 28215 Bremen Germany Telefon +49 421 3503-0 Telefax +49 421 3503-393 E-mail info@de.gestra.com Web www.gestra.de 810604-01/103c 2000 GESTRA GmbH Bremen Printed in Germany 16