Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

BZ-150. Installation Instructions. Power Pack SPECIFICATIONS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Aura Interior Wiring Manual (5-Wire and BACnet)

USER MANUAL 12 OUTLET 120/240V X-PLUG LIGHT CONTROLLER (FUEL SX12) APTX0120

Installation and Operation Instructions 10/04/13

Motion Sensing Coach Light

RK Standby Battery Operator s Manual

RK Standby Battery Operator s Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

SAFE & SECURE ACTUATOR PRODUCT MANUAL

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ZoneZ Lite Quick Start Guide

Transfer Switch GPTS 30

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

TC26-B Vehicle Sensor

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

Compact 150 Watt Motion Sensing Halogen

DUALBRITE Motion Sensing Coach Light

MaxLite LED Medium Area Light

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

AUTO CHARGE 1200 PUMP PLUS

BRAVO Inverter/Battery Charger. Table of Contents

AUTO CHARGE LPC SERIES

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

LN3 Series Motor and Drives

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Operations Manual. Zero Speed Switch Sensor Model ZS09P

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

Carbon Monoxide Transmitter

AFM500X Automatic Flashing Module

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

OutdoorXUPS-600AHV-8364

LED Auxiliary Devices

WF-5110R True Sine Wave Inverter

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

LED Downlight Ceiling Fixtures

Plug-in Dimmer Socket Kit

LED Emergency Drivers

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS

2904 Power Supply Installation Instructions I-EA00041

3200 SERIES BACK LIT CONVEYOR Special Capabilities Specification Sheet

PROFESSIONAL 270 o PIR MOTION DETECTOR

Application Engineering

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Product Installation Document

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Transfer Switch TS-50. Owner s Manual

Vigilante Series. Wallpack. We light your world

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

8-Unit Case Package Contents

HDE36 BATTERY POWERED CRIMP TOOL

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

ValveMate 7000 Controller Operating Manual

WF-5110R True Sine Wave Inverter

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Installation Instructions for Eaton Surge Protective

NEW PRODUCTS MAY 1, NEW PRODUCTS. MEP-81000WL POWER CENTER PAGE 3 To watch the video go to

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Aura CM-54i Surface Mount Illuminated Enclosure

DIN Rail UPS Model: DIN-UPS 48-5 Installation/Operation Manual

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

SAVE THESE INSTRUCTIONS

HXE4B BATTERY POWERED CRIMP TOOL

HYGRODYNAMICS DIGITAL DEW POINT MONITOR PC BOARD MODEL 6392N & 6392N2 TABLE OF CONTENTS

2016 Lighting Catalog

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Ultrasonic Level Switch

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

Owner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:

SCC-MPPT Solar Charge Controller

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Operating Instructions

Transcription:

HN-300 Fixture Mount Nightlight Controller with LED Assembly SPECIFICATIONS Power... 120VAC, 60Hz Relay Type... Form A, N.O. Load Requirements @120VAC... 500W isolated relay rated 5A 250VAC Low Voltage Connections RJ45 connection to FS sensor... Control in, common, +24VDC 8-Pin connector to LED strip and battery 2-wire output to LEDs.... 400mA @10VDC max. 2-wire output to 9V Ni-MH battery 5-8mA @10VDC max. Line and Load Connections.... 12-18AWG terminals Operating Temperature... 32 to 131 F (0 to 55 C) HN-200 Dimensions.. 7.5 x 0.75 x 1.5 (190 x 19 x 38mm) LED Light bar Dimensions 12.13 long x 0.5 dia. (30.8cm x 12.7mm) Installation Instructions

04799r1 C US LISTED Appliance Control 88T9 Model: Santa Clara, CA 800.879.8585 04800r1 DESCRIPTION The HN-300 kit contains an HN-200 controller plus a complete LED nightlight assembly. This assembly includes a 9V Ni-MH rechargeable battery, plug-in low voltage connector, LED light bar and a set of translucent mounting brackets that can be positioned anywhere along the light bar to facilitate mounting on the fixture. In addition, the mounting brackets are hinged for easy angle adjustment. The HN-200 controller supplies power to FS series occupancy sensors, a light fixture ballast and the LED light bar. It also supplies a trickle charge for a 9Volt battery that provides backup power to the LED light bar. The HN-200 is designed for installation inside the lighting fixture housing. The HN-200 has a male RJ45 plug attached to a 10 cable. Each FS series 24VDC occupancy sensor is equipped with a cable that carries power to the sensor and lighting control signals to the HN 200. The two devices connect using the shielded male-to-male RJ45 coupler provided with the HN-200. Typically, the HN-200 connects to one FS sensor inside the lighting fixture, however, each HN-200 can power up to three FS series sensors. FS-Cx accessories are required to connect multiple sensor wiring configurations. OPERATION The HN-200 must be used with a Legrand 740 31 momentary switch, provided with the HN-200. The switch toggles the fixture between full lighting operation, nightlighting using the LEDs, and no lighting at all. When the light fixture is ON, the FS sensor controls the light. When no motion is detected and the occupancy sensor s delay expires, the light goes OFF and the LED nightlight goes ON. Push the switch button twice to force OFF all lights. During a power failure lasting more than 2 seconds, the HN-200 uses the 9V battery to power the LEDs. To conserve battery, the LEDs appear dimmer than during normal nightlight operation. The length of time the LEDs are lit during a power failure depends on battery status. To protect the battery, the HN-200 turns off the LEDs when the battery discharges below a safe level. Low voltage connector to LED night light and Battery wire assembly Shielded male-to-male RJ45 extension connector Low voltage RJ45 connection to FS sensor Line voltage input and Switch wiring 120VAC Input HOT NEUTRAL GROUND Strip Gauge 12-18AWG CU wire only HN-200 Fixture Nightlight Controller 120VAC, 60Hz @120VAC 5A (N/O) ISOLATED RELAY OUTPUTS TO COM Green LED Fig 1: HN-200 connections and operation monitor LED Call 800.879.8585 or 972.578.1699 for Technical Support

04800r1 INSTALLATION 1. Determine an appropriate mounting location for the HN-200 inside the light fixture. Use the holes or mounting slots at both ends of the HN-200 to secure it to the fixture. 2. Determine a suitable mounting location on the outside of the fixture for the LED light bar. Make sure the 8-pin connectors from the LED light bar and the HN-200 meet. Make a 3/4 opening in the enclosure. Run the wire assembly from the LED light bar into the fixture by inserting it s 8-pin connector through a 3/4 opening. Install a grommet to protect the wires. 3. Install the LED light bar on the fixture using the mounting brackets (Fig 3). 4. Connect the 8-pin low voltage connector from the HN-200 to the 8-pin connector for the battery and LED light bar wire assembly. 5. Connect the 9V rechargeable Ni-MH battery to the snap-on terminals on the battery wire assembly inside the fixture. 6. Install the FS sensor and make appropriate adjustments as described in the FS installation instructions. 7. Connect the RJ45 from the sensor to the RJ45 on the HN-200. 8. Connect wires to load, switch and electrical supply as shown in the wiring section. High voltage wiring should use at least 16 AWG wire. Check local building codes. WIRING CAUTION MAKE SURE POWER IS OFF BEFORE WIRING THE SWITCH OR CONTROLLER. 12-16 AWG Line (Black) 1 L 2 Legrand 740 31 Momentary N/C Switch Cu Only HOT to COM Neutral (White) Ground (Green) 120VAC Input HOT NEUTRAL GROUND 04799r1 Strip Gauge 12-18AWG CU wire only C US LISTED Appliance Control 88T9 Model: HN-200 Fixture Nightlight Controller 120VAC, 60Hz @120VAC 5A (N/O) Santa Clara, CA 800.879.8585 ISOLATED RELAY OUTPUTS TO COM Neutral (White) Fig 2: HN-200 electrical supply, switch and load wiring Visit our website for FAQs: www.wattstopper.com

120VAC Input HOT NEUTRAL GROUND 04799r1 C US LISTED Appliance Control 88T9 Fixture Nightlight Controller 120VAC, 60Hz @120VAC 5A (N/O) Santa Clara, CA 800.879.8585 COM 04800r1 Knockout with Rubber Grommet Wire Assembly Adjustable Mounting Brackets LED Light Bar 9VDC Rechargeable Battery Strip Gauge 12-18AWG CU wire only Model: HN-200 ISOLATED RELAY OUTPUTS TO Red Black 8-Pin Connector BALLAST Male-to-Male RJ45 Connector FS-205-HN Sensor Exterior of Fixture Enclosure Interior of Fixture Enclosure Fig 3: HN-300 LED nightlight assembly and mounting Adjustable Mounting Brackets LED Night Light Bar Bulbs HN-200 Interior of Fixture Enclosure WALL Diffuser or Shade Sensor Call 800.879.8585 or 972.578.1699 for Technical Support

TROUBLESHOOTING Lights will not turn on: Sensor LED does not flash: - Is green HN-200 LED on? If yes, check RJ45 connections between sensor and HN-200. If no, check circuit breaker and wiring to wall switch and HN-200. - Check all wire connections. LED does flash: - Press the wall switch to toggle between OFF, nightlight, and full operation. - Check all wire connections and verify the load wire is tightly secured. Is the switch wired correctly? If the sensor has a light level feature, set it to maximum (even the brightest ambient light will not hold off the light fixture) and then retest to see if the lights turn on. If lights still do not turn on, call 800.879.8585 for technical support. Lights will not turn off: The time delay on the FS sensor can be set from 30 seconds to 30 minutes (60 minutes for the FS-205-HN). Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period. To quickly test the unit for proper operation, turn the time delay to minimum and move out of the sensor s view. Lights should turn off after 30 seconds. If lights still do not turn off, call 800.879.8585 for technical support. LED nightlight will not turn on: Cycle the wall switch by pushing the button to change between the main fixture light source and the LED nightlight. Check connections between LED light bar and HN-200 controller. Call 800.879.8585 or 972.578.1699 for Technical Support

ORDERING INFORMATION Catalog # HN-300 FS-105 FS-205 Description Fixture nightlight package includes: one HN-200 controller (120VAC, 60Hz), one male-to-male RJ45 connector, one Legrand 740 31 wall switch and cover plate, one LED light bar, one low voltage LED and battery wire assembly, one 9VDC rechargeable battery (sensor sold separately) Ceiling tile mount, low voltage PIR occupancy sensor with adjustable time delay and light level, 6 cable Fixture mount, low voltage PIR occupancy sensor with adjustable time delay and light level, 6 cable FS-205-HN Fixture mount, low voltage PIR occupancy sensor with adjustable time delay (up to 60 minutes) and light level, 1 cable. FS-305 FS-405 FS-505 FS-505C Fixture or ceiling tile mount, low voltage PIR occupancy sensor, adjustable time delay, 6 cable Fixture mount, low voltage PIR occupancy sensor w/20 diameter coverage, adjustable time delay and light level, 6 cable Fixture mount, low voltage ultrasonic occupancy sensor, 2 cable Same as FS-505, with directional cones All sensors and HN-200 are White. WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Watt Stopper/Legrand for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. 2800 De La Cruz Boulevard, Santa Clara, CA 95050 Technical Support: 800.879.8585 972.578.1699 www.wattstopper.com 06666r1 03/2006