Vertical Chemical Pumps

Similar documents
WET/DRY RUNNING INTANK VERTICAL CANTILEVER SEALLESS PUMPS TFV / TFO / TFP SERIES TI TOWN CHEMICAL PUMPS

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

PL Submersible, Semi-Vortex, Water Feature Pump

1/2 HP SUMP PUMP OWNER'S MANUAL

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Plunger Heads Use and Maintenance Manual

440/880LB ELECTRIC HOIST STF-4488EH

Submersible Pump Instructions. Safety Instructions

GL Ludemann Y-Strainers

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

OWNER S MANUAL STOP. Models: Blade Master 1.5 HP 1500 Series Stationary Transfer Pump 1.5 Pump, Single Phase AC 110/220V, Non-Explosion proof

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

USER S GUIDE FOR AUTO TRANSMISSION FLUID

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Installation, operation and maintenance manual

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

SANITARY SELF PRIMING PUMP Manual

SUBMERSIBLE MAGNETIC DRIVE PUMP SUBMERSIBLE YD-5002GWN. INSTRUCTION MANUAL Version: (for U.S.A)

AU DU PONT DE LUTTRE BRUSSELS BELGIUM PHONE: FAX: OPERATING MANUAL. Electric Fully Automatic Floor Saw FS 1218 EX

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

OPERATION & MAINTENANCE MANUAL HANGZHOU FLYING TECHNOLOGY CO., LTD.

Ph: (07) Fax: (07) Pump Manual

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

- click here for pricing and ordering

End Suction Centrifugal

KNAPSACK ELECTRIC SPRAYER

Installation and Maintenance Manual

SERIES OPERATION AND MAINTENANCE MANUAL

GMZ series Slurry Pump

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

Three Lobes Roots Blower. Instruction Manual

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Heavy Duty Engine Cranes

LS0512 Solar Charge Controller

MANUAL APPQO-HP2. For 100L and 200L Open Drum Can Air Type Vacuum Cleaner. Contents:

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Safety Precautions. Please be sure to closely follow all safety precautions and warnings. Danger. Warning. Caution

Sediment strainer (Type Y)

WARNING Carefully Read These Instructions Before Use

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

1 MECHANICAL FUEL METER

SUBMERSIBLE MINI-PUMP

150 Gallon 3- Point Hitch Sprayer

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Heavy Duty Engine Cranes

MP3450I Battery Bank Instruction (V1.0)

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

50:1 Grease Pump Kits

3.5 CUbIC feet portable CEMENT MIxER 02/2015 INSTRUCTION MANUAL MODEL: KC-15CM-2 COPYRIGHT 2014 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL


18- G A L L O N O I L D R A I N D O L LY OWNER S MANUAL

Ver Trunnion Ball Valve INSTALLATION, OPERATION AND MAINTENANCE MANUAL FBV/IOM/BA02

High Vacuum Diaphragm-Type Dry Vacuum Pump

IS7.6 INSTALLATION MANUAL

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

Pug Mill NRA-04 NRA-04S

Operating Instructions

Starting up hydraulic systems

Maintenance Information

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Agxcel GX12i Chemical Injection System

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

#9040 FUEL TANK SWEEPER

Dust cover. Plug. Outlet. Wire pole holder

582 Series. Instruction Manual. Two-Door Wafer Check Valve N-582 (R-08/2016)

110 Volt/12 Volt Portable Inflator

1600 PSI ELECTRIC PRESSURE WASHER

END SUCTION CENTRIFUGAL PUMPS

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

Foreword

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

1/2" AIR DRIVEN DIAPHRAGM PUMP

12V Oil Extractor Pump

STRUT SPRING COMPRESSOR

0.7 m 3 /h - 3 GPM D 07 RE 125 D 07 RE 5. owner s manual

NILFISK BA 500 Service Manual

Polypropylene Piston Drum Pumps

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

LS0512R Solar Light Controller

INSTRUCTION MANUAL (original instructions) K2, K3

Transcription:

Vertical Chemical Pumps JKD/JKT/JKH/JKP/JKV Series Instruction Manual JIEKAI INDUSTRIAL EQUIPMENT CO., LTD. 0

1. Introduction Table of Contents Model Definition... 2 Specification And Suitable Applications... 2 Specification Table.... 3-4 2. Installation Installation Dimension.....5-6 Announcements....7 Application Drawing.8-9 3. Operating Procedure Preparation Before Operation. 10 Announcements..10 4. Maintenance & Repair Preparation Announcements... 10 Maintenance & Repair 10 5. Troubleshooting.11 6. Using Announcements...12 7. JKD/JKT/JKH/JKP Parts Drawing JKD Series Assembly Drawing...... 13 JKT Series Assembly Drawing.13 JKP-1/8-1/6 Series Assembly Drawing 13 JKP-1/4-1/2 Series Assembly Drawing 13 JKH Series Assembly Drawing...14 8. Warranty Data Card.. 15 1

1. Introduction JKD 40 SK 3 5 V F (1) (2) (3) (4) (5) (6) (7) (1) Model NO.:JKD/JKT/JKH-W/JKH/JKH-Y/JKP/JKP-W (2) Outlet Diameter:15-1/2", 20-3/4", 25-1", 40-1-1/2", 50-2", 65-2-1/2", 80-3", 100-4" (3) Specific Gravity: SK-1.1 SP-1.4 (4) Horse Power: 1/15HP, 1/8HP, 1/6HP, 1/4HP, 1/3HP, 1/2HP, 1HP, 2HP, 3HP, 5HP, 7.5HP, 10HP, 15HP (5) Frequency:5-50HZ 6-60HZ (6) O-ring: V-VITON E-EPDM (7) Pump Body Material:F-FRPP P-PVDF Character: 1. They are made of corrosion resistant material: FRPP/PVDF, appropriate for high temperature & corrosion resistant for chemical solution. As used in the special environment, please confirm from our company or our local distributors. 2. The impellers are specially designed to ensure efficient operation and high performance. 3. Sealless shaft structure would avoid from the friction fault in the operation of the pump, therefore, could not let the pump breakdown when idle or processing with particles in the liquid. 4. The main parts of the pump are of injection molding to assure the precision of the whole pumps. 5. The motor is with steam protection features to avoid from the corrosion by the chemical steam. 6. JKT/JKH/JKP series are equipped with special flexible angle part, it will be easy to use for long time maintenance. 7. JKP series adopt "C" shape retaining ring combination, the main part of entrance is designed for in-tank applications. 8. JKD series are flange design, mainly used for installation out of tank applications. Application: 1. If equipped with chemical liquid filter, could be used for any kinds of plating solution filter and circulation. 2. Used in the PCB production of the etching or circulation. 3. Circulation and recycling operations for scrubber processor system. 4. Used for heat exchanger conveying pump. 5. Processing, circulation and stirring for all kinds of chemical reaction tank and chemical fluid in the mixing drum. 6. Loop filtering operation for electrolyte less plating. 2

Specification Table (Testing Fluid:S.G. / Water Proportion:1.0) JKD Series Vertical Pump Out Of Tank JKT Series Vertical Pump Out Of Tank 3

JKH Series Vertical Pump Out Of Tank JKP Series Vertical Pump Out Of Tank 4

2. Installation Installation Dimension Drawing JKD Series JKT Series JKP-1/8-1/6 Series JKP-1/4-1/2 Series JKH Series Vertical Pumps In Tank 5

JKD Series Vertical Pumps Out Of Tank JKT Series Vertical Pumps Out Of Tank JKP Series Vertical Pump In Tank 6

Announcements: 1. Install the pumps on firm & horizontal ground to keep the pump body vertical and well-fixed. 2. Avoid installation outdoor. If needed, please cover with visor for protection. If equipped with electronic controller, need to particularly protect. 3. Choose different pipe material according to for the chemical liquid surrounding, temperature condition, processing head and capacity. 4. Pay attention to without any residual impurities or debris inside the pipe to prevent air suction pump when piping. 5. When piping please pay attention to the pipe without any distortion, after installation, check the pump body again. If there is any movement and distortion affected when overdrive installation or improper installation. 6. Flange joint shall be lined with gasket to assure it lock well to prevent air suction pump. 7. If the entrance must be equipped with bottom valve or check valve, it is needed to equip with the check valve on the outlet position lower than the motor. 8. For safety's sake, you'd better equip with inlet strainer to avoid any damage due to suction sundries. 9. Entrance connecting flange must be the same as the inlet flange diameter, outlet flange must be the same as outlet flange diameter. 10. After installation you should confirm whether the pipeline is fixed well and tightly to avoid damage caused by vibrations. 11. Before plug in the power cord, you should confirm whether the power supply is consistent with the motor voltage, and equip with over-current protection switch. 12. Please well noted the motor nameplate specification according to demanded pump motor voltage, you can found circuit. 13. In order to protect the pump lifetime from damage caused by reverse pressure and vapor pressure pump, please connect the flexible hose with end drain fitting of pump, the other end should be connected to spare slot. Warning: The flow performance and security will be affected if fixed too tight or too loose will affect, please make sure all nuts locked well, otherwise it will cause liquid leakage; but it will be easily damage affected due to falling off if fixed too tight. Please finish the installation some familiar technical personals. 7

Application Drawing 8

Heat Exchange Circulating Pump Reaction Tank And Filter Compressor Pumps Notes: 1. Outlet pipe height, if it higher than the height of electric motor or check valves, please install check valve in the front of outlet pipe of pumps, the level of installing check valve keeps not too higher than the top or highest water level. 2. For inlet safety s sake, we had better install strainer, which avoid sucking impurities that will make pumps damaged. (Size of strainer mesh above 5 times as diameter) 3. While running pumps in special environment, and need to install anti-explosion or pressure resisting anti-explosion electric motor, please negotiate with our company technician. 4. While running pumps in an environment with chemical gas, it s necessary to choose special handling motor with electric-shock safeguard paint. 5. While running two vertical pumps in the same time, it s not allow to use the same outlet or inlet pipe, which will reduce pumps working life and function, more worse is damaging pumps. 9

3. Operating Procedure 3.1 Preparation Before Operation 1. Before running the pump, please pay attention to the following factors: the fluid type, proportion of viscosity, temperature, gravity. 2. Examine and Confirm whether the motor steering is consistent with labeled note on the motor fan cover. 3. Check the inlet, outlet flange and screw gasket should be locked firmly. 4. Check the liquid flow direction, the turning of the blade is decided by with the polarity of the power supply, you could note the correct direction through the cooling fan at the top of the motor. 5. Please note that the pump and pipeline can t be any leakage in order to avoid being hurt or environment pollution while running. 6. Make sure to fill with liquid before the pump running. 3.2 Announcements 1. Pay attention to the inward and outward valve is open, fluid level should be appropriate. 2. Workers need to wear protective clothing, gloves masks glasses and other protective equipment, in order to avoid skin contact with liquid. 3. Check the safety protection measures, such as liquid level controller, current breaker and ON/OFF switch. 4. Different kinds of chemical mixed together will cause chemical reactions, even high heat affected and make the pump damaged, therefore, so do not use the same pump to transport different chemical solutions. 5. Check the exit of pipeline at first before operation, be sure to check whether the valve has been opened, the flow go with right way, the liquid of barrels is normal and any breakage in the pipeline. 6. Please check and make sure the protection switch, such as liquid level switch and overload protection switch, etc. function well. 7. Check exit flow, when the capacity is too small, please immediately shut down pumps, and check the pipeline. 8. Outlet pressure must be lower than 3.2kg/cm. 9. Based on explosion protection and high pressure, please contact with our company before ordering. 4. Maintenance & Repair 4.1 Preparation Announcements 1. Please be sure to shut off the power. 2. Switch off inlet and outlet, discharge the liquid in the pump. 3. Maintenance personnel should wear protective clothing, gloves masks glasses and other protective equipment, and to avoid. 4. Pump should be lay down after removed please, do not place the motor on the upright. 4.2 Maintenance & Repair 1. Check the bottom valve or inlet strainer to avoid any impurity blocking. 2. When the motor running, pay attention to whether there is a different normal noise. 3. Check if there is electricity leakage. 4. If equipped with check valve, confirm whether it functions well. 5. If los of crystalline stay in the pump, it should be disassembled, please dip and clean the impeller, pump body and front cover in acidic solution and reassamble, or keep the pump in the acidic liquid circulation, and then rinse off with clear water circulation. 10

5. Troubleshooting Failure Circumstan Solution ce The motor cannot be started Power Overload Flow Capacity Normal motor speed but can not transfer liquid Too much noise shaking while pump running Pump with leakage liquid Fasten Spares(screw or nut) is worn 1. Check breaker. Power variation cause circuit overload. 2. Check if loose for power connector, if power lack of phase. 3. Impeller and pump body seizure, need to replace spares. 4. Impeller locked, clean impurities. 1. Too big liquid specific gravity, wrong models selection. 2. Unstable pressure cause overload. 3. Make friction between impeller and pump body, reassembly. 1. Check if block in the inlet of strainer. 2. Check if impurities locked in impeller. 3. Diameter of inlet pipe is too small. 4. Check outlet if block. 5. Motor diversion is opposite. 6. Motor speed is low. Check voltage if correct. 7. Check outlet or inlet ball valve if completely open. 1. Close outlet or inlet valve, open ball valve. 2. Air input into inlet. Check inlet pipe. 3. Too low inlet liquid level, which cause lack of liquid inside pump, supply liquid. 1. Worn motor bearing, replace bearing. 2. Motor spindle shaft is bend, replace motor spindle shaft. 3. Bearing housing is bend, replace bearing housing. 4. Impurities fill inside impeller or pump, dismount pump and clear it. 1. Replace O-ring. 2. While meeting liquid leakage during working, we should need to check outlet if block, which cause too big outlet pressure. If meeting liquid leakage while stop running pumps, we should need to check inlet if block, or need to consider if install check valve in front of outlet. 1. Replace fasten spares. 2. Replace chemical resisting fasten spares. (Such as PP, PVC, PPS, Titanium). 11

6. Using Announcements 1. While running pumps, prohibit arbitrarily changing chemical properties, because mixing different chemical properties will produce different chemical change, even chemical reaction will produce high heat, which damage pump itself. 2. Many chemical properties are seriously hurt human body, operator should try to avoid this dangerous area. 3. Before starting power, we should check the pipe and valve location if correct, power on if correct, at the same time, check liquid if discharge normally. 4. Transferring dangerous liquid under abnormal operation condition, such as outlet or inlet is close, pump selecting models is wrong, operation in idle, wrong pipe materials, which will produce serious danger, especially in idle process, which will make liquid inside pumps produce high temperature and gasify, some chemical properties includes hydrogen, which will seriously cause gas explosion and hydrogen explosion, we should specially notice it while operating. 5. Confirm outlet flow capacity while running pumps, if you find the outlet flow capacity is too small, we should shut down the pumps, and check the pipe if block. 6. Running under especial environment, and need safe explosion proof or pressure resisting explosion proof motor, please contact with our company technician. 7. Running under filled with chemical gas, we must select special handling motor with corrosion resistant paint. 8. Any misuse such as overpressure, self replace spares, mismatch chemical properties or using worn spares will produce serious dangerous condition, please follow safety warning. 9. Resisting temperature of all kind of materials as below: CFRPP:0-75 FRPP:0-75 CPVC: 0-75 PVDF:-20-90 10. We should well know pumps operation before researching problems, please carefully read this user manual, even all unit parts installation, this manual with sufficient instruction. 11. While transferring dangerous liquid or locate in dangerous environment, please wear safeguard glove and glass. 12

7. JKD/JKT/JKH/JKP Parts Drawing JKD JKT JKP-1/4-1/2 JKP-1/8-1/6 13

14 JKH

8. Warranty Date Card 15