RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

Similar documents
RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

Residual current circuit breakers with conditional shortcircuit

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

max pole for t=15 ms

Fuse switch-disconnectors

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Devices for switching and control

Fuse switch-disconnectors

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

MOULDED CASE CIRCUIT BREAKERS BC160N

Low Voltage A GE Power Controls Company. General catalogue

Residual current devices

Overcurrent releases - description, specifications, characteristics specifications specifications description...

RESIDUAL CURRENT CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Selective main circuit breakers S 750 series Technical Data

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

and other modular devices for low voltage installation

Residual Current Circuit-breaker (RCCB) FH 200 Series

DX³ 4-pole RCBO 6000 A/10 ka

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

COMBINATION CIRCUIT BREAKERS RCBO

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

TX³ RCCBs 2P up to 100 A

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

NH-Fuse system Low voltage

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

MOULDED CASE CIRCUIT BREAKERS BC160N

Miniature Circuit Breaker

Miniature Circuit-Breakers (MCBs)

Electronic Circuit Breaker ESS20-0..

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

3 - Protection components Motor circuit-breakers

Btdin RCBO 6000A up to 63A (2P)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

3VU13, 3VU16 Circuit-Breakers

Phase + Neutral, neutral on right side

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Electronic circuit breaker EBU10-T

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

DX³ RCCBs - ID 4P up to 100 A

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Main catalogue. Distribution Innovation

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side

Miniature Circuit-Breakers (MCBs)

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

DSE201 Compact design with enhanced protection

D509E. Manual Motor - Starters

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

MS25, MST25, MS20, MST20

MOULDED CASE CIRCUIT BREAKERS BL1600S

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

NB1 Miniature Circuit Breaker

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

TECHNICAL DESCRIPTION

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

1489-M Circuit Breakers

COMPLETE SOLUTIONS FOR POWER PROTECTION

Protection Equipment

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Jtec 10kA Miniature Circuit Breaker

QUALITY ASSURANCE & DOCUMENTATION

All round protection guaranteed

Control Circuit Protection

Series L9 UL489 Miniature Circuit Breakers

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

BETA Low-Voltage Circuit Protection

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

LV HRC fuse switch-disconnectors

TECHNICAL DESCRIPTION

Power systems Protection course

Domae. The right solution for distribution boards

DX³ RCBO 6000A Phase + Neutral, neutral on left

Essential equipment for all your requirements

3VT1 Molded Case Circuit Breakers up to 160 A

Transcription:

Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Standard type for common use in building and housing installations up to 3 A, 230/400 V a.c. They react to alternating sine-wave residual current (type AC) For protection: against accidental contact of live parts (I n 30 ma) against accidental contact of exposed conductive parts against fire or short-circuit at decrease of insulating capacity of electric equipment (I n 300 ma) Possibility of additional mounting of auxiliary switches PS-OFI11 on the right side of the device Surge resistance up to 20 A (8/20 µs) Possibility of interconnection with miniature circuit breakers LSE (LSN) by means of busbars 000 Residual current circuit breakers 2-pole I n I n Type Product Weight Packing [A] [A] code [kg] [pcs] 2 0.03 OFE 2/2/030/AC OFE20 1800 0.24 1 Residual current circuit breakers 4-pole I n I n Type Product Weight Packing [A] [A] code [kg] [pcs] 2 0.03 OFE 2/4/030/AC OFE40 1804 0.4 1 40 0.03 OFE 40/4/030/AC OFE40 180 0.4 1 0.3 OFE 40/4/300/AC OFE40 1807 0.4 1 3 0.03 OFE 3/4/030/AC OFE40 1808 0.4 1 0.3 OFE 3/4/300/AC OFE40 1809 0.4 1 OFE accessories Auxiliary switch PS-OFI11 page 34 Interconnecting busbar G-2L-1000/1, G-4L-1000/1 page 93 Connecting adapters AS/2-GN, AS/2-SN page 9 Specification Type OFE20 OFE40 Standards EN 1 008 EN 1 008 IEC 7 IEC 7 Approval marks Number of poles 2 4 Type AC AC Surge resistance (8/20 μs) 0.2 ka 0.2 ka Release delay - - Rated operating voltage U e 230 V a.c. 230/400 V a.c. Min. operating voltage U min 100 V a.c. 100 V a.c. Rated current I n 2 A 2, 40, 3 A Rated residual current I n 0.03 A 0.03; 0.3 A Rated frequency f n 0/0 Hz 0/0 Hz Mechanical and electrical endurance operating > 10 000 cycles operating > 10 000 cycles Mounting on the rail DIN EN 0 022 - width 3 mm 3 mm Rated conditional short-circuit current with backup fuse I n 3 A gg I nc ka - with backup fuse I n 100 A gg I nc - ka with backup circuit breaker LSN, LST, LSE with I n max. 1:1 I nc ka ka Connection conductor 1 1 mm 2 1 2 mm 2 busbar 1 mm 2 1 mm 2 opposite yes yes Operating conditions ambient temperature - 4 C - 4 C seismic immunity (8 0 Hz) 3 g 3 g operating position arbitrary arbitrary 32

Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) OFE20 OFE40 4 90 3 72 7 44 4 Diagram OFE20 1 N OFE40 1 3 N 2 N T 2 4 N T 33

Residual current circuit breakers AUXILIARY SWITCHES H001 Accessories to LFI and LFE Installation: on the right side The auxiliary switch is designed for signalling the position of the main contacts of residual current circuit breakers with overcurrent protection PS-OFI11 Accessories to residual current circuit breakers OFI and OFE Installation: on the right side The auxiliary switch is designed for signalling the position of the main contacts of residual current circuit breakers 21 13 22 Auxiliary switches Type Contact sequence 1) Product code Packing [pcs] Weight [kg] H001 001 13138 1 0.0 PS-OFI11 11 1239 1 0.0 1) Each digit indicates successively the number of make, break and break-make contacts Specification Type H001 PS-OFI11 Approval marks Contact sequence 1) 001 11 Rated operating voltage / current U e /I n 230 V a.c. / A 230 V a.c. / A 220 V d.c. / 0, A 220 V d.c. / 1 A 24 V d.c. / 4 A Degree of protection IP20 IP20 Mounting on right side on right side 1) Each digit indicates successively the number of make, break and break-make contacts H001 8 PS-OFI11 13 21 4 90 4 90 9 9 9 98. 43. 9 22 7 44 4. 4 Diagram H001 PS-OFI11 9 98 21 13 9 22 34

Interconnecting systems INTERCONNECTING BUSBARS AND END CAPS Interconnecting busbars For interconnection of 1 to 4-pole circuit breakers, tumbler power switches, residual current circuit breakers, lightning current arresters and surge voltage arresters For interconnection of a series of single-phase or three-phase circuit breakers and tumbler power switches, on which an auxiliary switch is mounted Busbars G- with forks into the head part of the device Busbars S- with pins into the clip part of the device End cap EK-C-3: To cover end of busbar G-3L-1000/10C End cap EK-C-2+3: To cover end of busbar G-2L-1000/1, G-3L-1000/1C, S-3L-27-1000/1 End cap EK-C-3/3: To cover end of busbar S-3L-27-1000/2 End cap EK-C-4/1: To cover end of busbar G-4L-1000/1 Interconnecting busbars Phase Cross - Max. current at power Length Type Product Accessories to Weight Packing section supply of [A/phase] [mm] code [kg] [pcs] [mm 2 ] end middle 1 12 110 1000 G-1L-1000/12 001 LSN, LSE, ASN 0. 22 0 G-1L-1000/12g 1) 000 LSN, LSE, ASN 0.1 0 1 80 130 210 S-1L-210/1iso 13012 LSN, LSE, SVL, SJL, ASN 0.04 0 20 90 0 1000 G-1L-1000/20 002 LSN, LSE, SJB, SVM, ASN 0.3 0 24 100 180 1000 G-1L-27-1000/24 2) 11001 LSN, LSE, ASN 0.3 0 2 1 80 130 1000 G-2L-1000/1 119 LSN, LSE, LFI, LFE, OFI, OFE, ASN 0.4 20 3 10 3 100 1000 G-3L-1000/10C 003 LSN, LSE, ASN 0.44 20 1 80 130 1000 G-3L-1000/1C 004 LSN, LSE, OFI, OFE, SJB, SVM, ASN 0.72 20 G-3L+9-1000/1 2) 11002 LSN, LSE, ASN 0. 10 S-3L-27-1000/1 3) 1184 LSN, LST, LSE, ASN, AST 0.2 20 2 100 180 1000 S-3L-27-1000/2 3) 118 LSN, LST, LSE, ASN, AST 0.9 10 4 1 80 130 1000 G-4L-1000/1 11180 LSN, LSE, OFI, OFE, ASN 0.9 1) The busbar is uninsulated 2) For 1-pole or 3-pole devices with an auxiliary switch 3) For 3-pole LST; for 1-pole LSN, LSE, ASN with an auxiliary switch End caps Type Product Accessories to Weight Packing code [kg] [pcs] EK-C-3 008 G-3L-100/10C 0.001 10 EK-C-2+3 00181 G-2L-1000/1, G-3L-1000/1C, S-3L-27-1000/1 0.001 10 EK-C-3/3 11 S-3L-1000/2 0.002 10 EK-C-4/1 11181 G-4L-1000/1 0.002 10 Specification Type G-1L, G-2L, G-3L, G-4L, S-1L, S-3L Rated operating voltage U e 230/400 V a.c., 220/440 V d.c. Load current 3 180 A Length 210, 1000 mm Cross-section 10 2 mm 2 Diagram G-1L, S-1L G-2L G-3L, S-3L G-4L L1 L1 L2 L1 L2 L3 L1 L2 L3 N (N) 93

Interconnecting systems INTERCONNECTING BUSBARS AND END CAPS G-1L-1000/12 G-1L-1000/12g 7x1 99.8 (x) 12 7x1 99.8 (x) 1 3 12 S-1L-210/1iso 12x1 4 19.8 (11x) 7x1 12 99.8 (x) 2 G-1L-1000/20 G-1L-27-1000/24 37x1 972 (3x27) 27 12 2 G-2L-1000/1 28x2 11 979 (x) 29 G-3L-1000/10C G-3L-1000/1C 19x3 11 99.8 (x) 1 19x3 11 99.8 (x) 2 30 13. G-3L+9-1000/1C S-3L-27-1000/1 1x3 971. (47x+x9) 2.8 (+9) 12 1x3 2.8 938 (3x2.8) 4 29 29 24. S-3L-27-1000/2 G-4L-1000/1 1x3 27 94 (3x27). 2 x4 979 (x.) 11 30 43 27 20. 18.3 94

-2-2 Interconnecting systems CONNECTING ADAPTERS AND BLOCKS Connecting adapter AS/2-GN Accessories to: LSN, LSE, LFI, LFE, OFI, OFE, SJB, SVM, ASN For connection of another conductor to the head part of the terminal of a circuit breaker or tumbler power switch For example, it the best solution is to connect a conductor for power supply of an electric meter in the clip part of the circuit breaker terminal, and another conductor through the connecting adapter AS/2-GN in the head part of the circuit breaker terminal Conductor cross-section: 2 mm 2 Connecting adapter AS/2-SN Accessories to: OFI20, OFE20, SVL, SJL, RP1 For connection of conductor to the clip part of the terminal of a circuit breaker or tumbler power switch Conductor cross-section: 2 mm 2 Connecting adapter AS-AL/Cu-1-0 Accessories to: LSN, LST, LSE, LFI, LFE, SJBplus, ASN, AST For connection of Al or Cu conductors Cross-section of Cu conductors: 2. 0 mm 2 Cross-section of Al conductors: 1 0 mm 2 Connecting adapter CS-FH000-...NP9 Accessories to: LST, SJBplus, SJB100/NPE/1,, AST For connection of Cu/Al conductors of cross-section 3 9 mm 2 Connecting adapter with straight terminal Connecting adapter CS-FH000-3NV9 Accessories to: LST, SJBplus, SJB100/NPE/1,, AST For connection of Cu/Al conductors of cross-section 3 9 mm 2 Connecting adapter with outbowed terminal Connecting adapter N3x10-FH000 Accessories to: LST, SJB, SVM, AST For connection of 3 conductors/pole of the device of cross-section 10 mm 2 Connection block ES/3S/G Accessories to: G-1L, G-2L, G-3L, G4-L, S-1L, S-3L It enables power supply of interconnecting busbars of conductors of section up to 3 mm 2 The blocks can be installed in series to create a multiplepole connection block Degree of protection IP20 Connecting adapters Type Product Weight Accessories Set Packing code [kg] to [pcs] [pcs] AS/2-GN 007 0.012 LSN, LSE, LFI, LFE, OFI, OFE, SJB, SVM, ASN 1 10 AS/2-SN 00 0.013 OFI20, OFE20, SVL, SJL, RP1 1 10 AS-AL/Cu-1-0 1831 0.01 LSN, LST, LSE, LFI, LFE, SJBplus, ASN, AST 1 CS-FH000-3NP9 13740 0.1 LST, SJBplus, SJB100/NPE/1,, AST 3 1 CS-FH000-1NP9 378 0.1 LST, SJBplus, SJB100/NPE/1,, AST 1 1 CS-FH000-3NV9 13742 0.1 LST, SJBplus, SJB100/NPE/1,, AST 3 1 N3x10-FH000 127 0.02 LST, SJB, SVM, AST 3 1 Connection block Type Product Weight Packing code [kg] [pcs] ES/3 S/G 00 0.03 10 AS/2-GN AS/2-SN AS-Al/Cu-1-0 N3x10-FH000 22 24.. 20. -2-2 20. 2. 27 CS-FH000-...NP9 CS-FH000-3NV9 ES/3 S/G 24 32. 24 32.. 2. 38 38 32 9

Residual current circuit breakers BASIC TERMS AND SYMBOLS Rated residual current I n is the value of residual current I specified by the manufacturer at which the residual current circuit breaker must switch out under specified conditions. Alternating residual current must release the residual current circuit breaker within (0. 1) I n Rated current In is the value of current specified by the manufacturer, which can be transferred by the residual current circuit breaker continuously. So the current In can pass through the contacts for an unlimited time. Therefore it is, for instance, possible to use a residual current circuit breaker with In = 2 A in 1 A circuit. For protection against overload of the residual current circuit breakers OFI, OFE, it is recommended to use the miniature circuit breakers LSN, LST, LSE with rated current In MCB In RCCB Rated operating voltage Ue is the voltage the residual current circuit breaker is to be connected to and which properties are related to. The connected voltage has no effect on the device function but on the function of the test circuit and isolation properties. Rated frequency fn is the frequency the residual current circuit breaker is designed for and at which it works correctly under stated conditions. Majority of residual current circuit breakers are designed for fn = 0 to 0 Hz. As the residual current circuit breaker function is based on the induction principle, the residual current behaviour and frequency show an effect upon tripping. When using a device designed for 0/0 Hz in a network with a different frequency, the user must count on a change of the tripping threshold i.e. a change of I n Rated conditional short-circuit current Inc short-circuit strength. The function and design principle does not allow for the residual current circuit breaker use for protection against short-circuit. For circuit protection it is necessary to use a circuit breaker or a fuse. These elements cut the short-circuited circuit safely off. The residual current circuit breaker must only withstand the through-going short-circuit current. The amplitude of the maximum through current is defined as rated conditional short-circuit current Inc. The short-circuit strength is then expressed by the current Inc. For example, on the rating plate, Inc = 10 ka is expressed by the following symbol: 10 000 Ambient temperature T for the residual current circuit breakers is (- +40) C according to almost all international standards. Some residual current circuit breakers work in an extended range (-2 +40) C. This possibility is identified by the following symbol on the rating plate. -2 Residual current circuit breaker type AC reacts to sine-wave residual current it is used in conventional AC networks. The main reason of selective switching is higher time delay of the selective residual current circuit breakers in releasing (compared to standard or G type ones). Residual current circuit breaker type A reacts to sine-wave alternating and pulsating direct residual currents - it is used in conventional AC networks and the networks with phase power regulation etc. I ns = 0.3 A Residual current circuit breaker type G special residual current circuit breaker reducing the number of undesirable releases. It is mainly installed before the devices causing short-time (up to 10 ms) stray currents. Identification: G Surge resistance: 3 ka (8/20 µs) Release delay: 10 ms G Residual current circuit breaker type S special residual current circuit breaker, which is mainly intended for selective switching of residual current circuit breakers and reduction of undesirable releases. It is installed before the devices causing short-time (up to 40 ms) stray currents. Identification: S Surge resistance: ka (8/20 µs) release delay: 40 ms S Selective (discriminating) switching means that if the residual current circuit breakers are connected in series, only the device in which circuit a failure occurs will release. More specifically, only the device in which the release residual current appears due to a failure in the protected circuit will release. The advantage consists in maintaining the power supply in the other circuits not affected by the failure. I ng = 0.03 A I n- = 0.1 A LOAD LOAD Fig. 1: Simplified example of selective connection of residual current circuit breakers. Residual current circuit breaker with overcurrent protection the device is a combination of residual current circuit breaker and miniature circuit breaker with 2-module width - it saves the space in the switchboard compared to conventional connection of two separate devices (3 modules). This eliminates the problem of primary protection and interconnection. The disadvantage of such a design compared to conventional ones is that it is not possible to identify whether the release was actuated by the residual current circuit breaker or by overcurrent release of the circuit breaker. Such function of the protected circuit is achieved by connection of the selective residual current circuit breaker (see Fig. 1) before the standard or G type residual current circuit breaker, with the following ratio of rated residual currents: I n S 3 x I n -,G I ns rated residual of the selective residual current circuit breaker I n -,G maximum rated residual current of G type residual current circuit breaker I o V D E Fig. 2: Example of interconnection of the residual current circuit breaker OFI with miniature circuit breaker LSN by busbar G-4L 3