BARRIER INSTALLATION GUIDE Produced by B. S Developments Manufacturers of Easi Set JJ HOOK Barriers

Similar documents
TRACC. Trinity Attenuating Crash Cushion

Questions and Answers from March 1 st, 2016 Roadbuilders Introduction Webinar

Exhibit H: Typical Traffic Control Plans. North Metro Natural Gas Pipeline Project Routing Study

Code of Practice for Temporary Traffic Management (CoPTTM)

Safety Barrier System Conditions

Illinois Safety Program IDOT District ATSSA Workshop

CTOC Best practice for speed management at roadwork sites

VULCAN BARRIER TL-3 GENERAL SPECIFICATIONS

Ara Tūhono Pūhoi to Wellsford Road of National Significance: Pūhoi to Warkworth Section

Procedure Effective date Rescinds Vehicle Placement In or Near Moving Traffic 17 November January 2005

Crash Testing Growth Common Roadside Hardware Systems Draft FHWA and AASHTO Requirements for Implementing MASH 2015

Section 6H.01 Typical Applications

Code of practice for temporary traffic management (CoPTTM)

All specifications in this manual are subject to change without prior notice

DESIGNATED CONSTRUCTION ZONE SPEED FINES DOUBLE. Manitoba Infrastructure and Transportation. Infrastructure and Transportation. Traffic Engineering

AASHTO Manual for Assessing Safety Hardware, AASHTO/FHWA Joint Implementation Plan Standing Committee on Highways September 24, 2015

Code of practice for temporary traffic management (CoPTTM)

[Insert name] newsletter CALCULATING SAFETY OUTCOMES FOR ROAD PROJECTS. User Manual MONTH YEAR

SMART CUSHION INNOVATIONS

SMART CUSHION INNOVATIONS

TRAFFIC CONTROL PLAN FOR SURVEYING OPERATIONS END ROAD WORK END ROAD WORK * ** END ROAD WORK END ROAD WORK. TCP (S-1a) TCP (S-1b)

Plastic Safety Systems

Diagram 1 - Shoulder Assistance

STATE ND PROJECT NO. CP 0883 (14) & CP 1152 (14) SHEET NO. TOTAL SHEETS 9 31 SIGN NUMBER SIGN SIZE DESCRIPTION AMOUNT REQUIRED UNITS PER AMOUNT UNITS

Implementation of AASHTO s Manual for Assessing Safety Hardware (MASH) 2016

Maine Turnpike Authority

DISTRIBUTION: Electronic Recipients List TRANSMITTAL LETTER NO. (15-01) MINNESOTA DEPARTMENT OF TRANSPORTATION. MANUAL: Road Design English Manual

RUMBLE STRIPS QUESTIONS AND ANSWERS

AGC/MoDOT Annual COOP Meeting. Safety/Traffic Division & Specialty Contractors/Suppliers Breakout Session. December 5, 2018

CAN AM. Version 1. Version Outlander 400, 500, 650, 800 and Outlander Max Renegade 500/ Outlander 800R/1000R

Page 1 of KA

O5 GENERAL VEHICLE ISSUES

Schedule 18 (Technical Requirements) DBFO Agreement EXECUTION VERSION APPENDIX B - SELECT DEPARTMENT STANDARD DRAWINGS AND REFERENCE TABLES

FREQUENTLY ASKED QUESTIONS

Safe use of portable ladders

PERFORMANCE ACTIVITY 603 SIGNS

Date of Issue: For: County Engineer. County Road No.: Maintenance Area: Section Forman Payment Required: (Options: Cash Cheque Credit Card)

STANDARD DRAWING INDEX

TIME TASK FORCE. Guidelines for the Mitigation of Motor Vehicle Fluid Spills at Crash Scenes (Non-Cargo)

2013 Changes to the 2011 MMUTCD, Part 6 September 2013

MODULAR GUIDE AND PROTECTION SYSTEMS

Mobile Barrier Trailer

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 961 PORTABLE TRAFFIC SIGNALS OCTOBER 17, 2008

TTI TRAFFIC SAFETY CONFERENCE. John A. Barton, P.E.

FEASIBILITY LAND TRANSPORTATION VENTUS ENERGY. from. covering WIND TURBINE EQUIPMENT PORT OF MOUNT MAUNGANUI TO KAIMAI RANGE SITE. for.

Product Information. Tested System Transitions DB SafeLink. Safe transition to other safety barrier systems

Maine Turnpike Authority

SUPERSEDED. Code of practice for temporary traffic management (CoPTTM) Section D. Traffic Control Devices Manual Part 8. manual number: SP/M/010

FREQUENTLY ASKED QUESTIONS

Assembly Manual Stemmons Freeway Dallas, Texas 75207

Guidelines For the MITIGATION OF ACCIDENTAL DISCHARGES OF MOTOR VEHICLE FLUIDS (NON-CARGO) APPROVED 6/25/04

MEMORANDUM TERESA MCCLISH, DIRECTOR OF COMMUNITY DEVELOPMENT

ArmorGuard Barrier Portable Longitudinal Barrier

CrashGard. Sand Barrel System Product Guide

High Tension Cable Barrier

Designing and Manufacturing Modular Spreader Beam Systems for a Cost-Effective, Safe Lift

Temporary Traffic Control Plans

Rev. E September All rights in copyright preserved

Worksite Safety Update Promoting safety in road construction

Best Practice for TTM Impacting Bus Services

Maine Turnpike Authority

PRODUCT DESCRIPTION. X-Tension DS. is suitable for all road types: Motorways, country roads, city streets for speed categories up to 110 km/h.

Strategies for Negotiating Hills and Curves

2 Min. Min. Edge of. Edgeline See Note 3 PLAN VIEW. See Note 3. This distance may vary

Product Specification. ABSORB 350 TM TL-2 Non-Redirective, Gating, Crash Cushion Applied to Quickchange Moveable Barrier

Table of Contents. Scorpion Truck Mounted Attenuator 1. Scorpion Trailer Attenuator 9. Big Sandy Sand Barrels 13. TrafFix Water-Wall 16

Who s doing the work? Who do I call with questions I may have after I read this FAQ? Why is my street being slurry sealed?

Interchange Ramp Characteristics (Selection and Design)

ALABAMA DEPARTMENT OF TRANSPORTATION DATE : 06/14/13 PAGE : VENDOR RANKING

ArmorGuard Barrier Portable Longitudinal Barrier

DELINEATOR REFERENCE POINT 200' TYPICAL SPACING (YELLOW DELINEATORS) END OF MERGE LANE TAPER DELINEATOR REFERENCE POINT

CrashGard. Sand Barrel System Product Guide

Utility Mount. Tailgate Spreaders. Installation Instructions CAUTION. Read this document before installing or operating the spreader.

ROAD SAFETY PRODUCTS. Randgate Consultants Pty Ltd College House, 26 Peter Place Road, Bryanston 2021 T:

Model 1000 Low Profile Tailgate Spreader Receiver Mount

SCDOT TRAFFIC SIGNAL SPECIAL PROVISIONS TRAFFIC CONTROL FOR TRAFFIC SIGNAL PROJECTS MAINTENANCE OF TRAFFIC


Technical test - Theory. Appointed Person A61. No. Question Answers Max. Mark

SECTION 12 - CONSTRUCTION AREA TRAFFIC CONTROL TABLE OF CONTENTS

South Carolina. It s serious. Deadly serious.

Vanguard Road Plate. Modular trench cover system to allow passage by traffic and pedestrians during road works. Product operating parameters:

Guide Rail Safety Symposium

INVITATION TO TENDER FOR THE SUPPLY OF CHASSIS IN THE 2020, 2021, 2022 AND 2023 FIA WORLD RALLYCROSS CHAMPIONSHIP

Table of Contents. Chapter 2 Safety Fundamentals for Bridge Inspectors. Methods of Access Introduction

Objectives. Understand defensive driving techniques. Increase awareness of safe driving behaviors

Twin Discovery Systems Inc.

BY-ELECTION SIGN GUIDELINES

MASH 2016 Implementation: What, When and Why

S T A T E O F M I N N E S O T A D E P A R T M E N T O F T R A N S P O R T A T I O N DATE : 02/27/06 PAGE : 1 TABULATION OF BIDS

safedirection.com.au Ref: PM 017/02

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

DRIVING P2 IN NEW P36 ZEALAND

S T A T E O F M I N N E S O T A D E P A R T M E N T O F T R A N S P O R T A T I O N DATE : 05/01/00 PAGE : 1 TABULATION OF BIDS

WARNING. 4. The wearing of safety glasses, footwear and personal safety clothing is compulsory.

Roadside Safety MASH

Sight Distance. A fundamental principle of good design is that

75918 Heavy Duty 3-Point Mount

s Contact the Area Construction Engineer at for RAP sample location. Page 2 of 10

Motorways Route in Thailand. Sustainable Highway Design

Land Transport Rule Setting of Speed Limits 2017

Transcription:

BARRIER INSTALLATION GUIDE Produced by B. S Developments Manufacturers of Easi Set JJ HOOK Barriers THIS IS A GUIDE TO ASSIST ENGINEERS AND CONTRACTORS TO SELECT THE MOST APPROPRIATE OPTION TO PROTECT THEIR WORKSITE. THIS IS TO BE USED AS A GUIDE ONLY. ENSURE YOU REFER TO THE REQUIREMENTS IN COPTTM AND ENSURE YOU MEET THE REQUIREMENTS OF THE ROAD CONTROLLING AUTHORITY IF IN DOUBT CONTACT...JOHN GLEN 0273666099. e mail traffnz@orcon.co.nz 1

CODE OF PRACTICE FOR TEMPORARY TRAFFIC MANAGEMENT ( COPTTM) REFERENCE. www.nzta.govt.nz go to Manuals SECTION B EQUIPMENT SUB SECTION 7 BARRICADES SUB SECTION 11 BARRIERS 2

Barrier compliance requires Barriers to be tested to NCHRP 350 TL 1,2 or 3. TL1...Up to 50 kph TL2...Up to 70 Kph TL 3...Up to 100kph. NCHRP350 TESTS LEVELS Product Item Compliance TL 1 TL 2 TL 3 B.S Developments JJ Hook Concrete Barrier YES YES YES Idaho barriers (pin Loop) multi manufacturers YES YES YES Barrier Guard (steel barrier) Armourflex YES YES YES Absorb 350 from CSP Crash end terminal YES YES YES (COMPLIANCE FULLY CONNECTED AND FILLED WITH WATER. Triton water filled from (Saferoads) as a CRASH TERMINAL YES YES YES ( for compliance fully connected and filled with water) Triton water filled barriers as a barrier system YES YES YES (for compliance linked and fully filled with water) Armourflex (PLASTIC) water filled barriers YES NO NO (Compliance f requires them to be fully linked and ballasted with water) HIREPOOL, RSEA,HIREQUIP ETC.plastic waterfilled NO NO Units are only BARRICADES and are NOT crash rated NO 3

Crash rated waterfilled barriers. To be compliant they must be installed as per the crash test..linked and filled with water. Limited stocks available SAFETY WARNING ALL UNITS MUST HOLD WATER TO COMPLY ARMOURFLEX 50KPH BARRIER 4

BARRICADES. PLASTIC WATER FILLED UNITS. HIREPOOL HIREQUIP RSEA AND GENERAL HIRE CO S WHAT IS A CRASH BARRIER AND WHAT IS NOT NCHRP 350 CRASH BARRIER CONTACT B.S DEVELOPMENTS FOR SUPPLIER DETAILS FOR SALE FOR HIRE NOT A CRASH RATED BARRIER THIS IS A CRASH RATED BARRIER SYSTEM THIS IS A BARRICADE AND CAN NOT BE USED AS A CRASH BARRIER 5

CAUTION WHEN USING PLASTIC WATER FILLED BARRIER SHAPED UNITS The water filled ( w/f) BARRICADES that are presently in wide use in association with the construction industry DO NOT meet any CRASH test criteria. BE AWARE. Note Check the individual barrier and there is an imprint that warns that the barrier should not be used as a crash barrier. The w/f BARRICADES that do not have a crash test rating are BARRICADES known as RSEA s..rhino and Arrow Hire Pool s..w/f barriers Projex..w/f barriers And all other hire Co barriers. SPECIAL NOTE. The above BARRICADES can be used as delineators providing they are offset by 1 m and marked by a line of 900mm cones. For the BARRICADES to be used in any other format an EED (Engineering Exception Decision) is required at time of TMP submission. 6

INCORRECT SELECTION OF SITE PROTECTION!!! SITE WAS SHUT DOWN IMMEDIATELY!!!! CONCRETE BARRIERS REPLACED THE PLASTIC BARRICADES THE NEXT DAY. EXTREMELY DANGEROUS SITUATION... SITE INTRUSION...RESULT WOULD HAVE BEEN DEATHS WELLINGTON SITE WELLINGTON SITE W/FILLED PLASTIC BARRIERS HAD NO WATER BALAST 8M DROP OFF NOTE DIGGER LOWER PHOTO 6 T DIGGER NOT CRASH RATED SYSTEM NOTE SAND BAG THIS WAS THE ONLY THING STOPPING THE BARRIER FROM MOVING NOT EVEN BALASTED WITH WATER 7

NON COMPLIANT BARRIERS. RE CYCLED MEDIUM BARRIERS NON TESTED CONNECTION. LEGAL ACTION IN THE EVENT OF AN ACCIDENT IS THE RISK WORTH IT? MOTORWAY LOWER HUTT 2009 KNOW WHAT YOU CAN USE MOTORWAY LOWER HUTT 2009 DROP OFF NON COMPLIANT CONNECTION DANGEROUS UPPER LEVEL CRASH IMPACT...BARRIER FAILURE SERIOUS INJURY / DEATH AS A RESULT OF BARRIER FAILURE 8

DIFFERENT WATER FILLED END TREATMENTS TO BE COMPLIANT THEY ALL NEED TO BE INSTALLED TO THE MANUFACTURES SPECIFICATIONS. THEY ALL NEED TO BE FILLED WITH WATER AS WELL TO BE COMPLIANT. TRITON TL3 COMPLIANT ABSORB 350 TL3 COMPLIANT 100 KPH COMPLIANT 6 UNITS REQD LEADING TURNED UPSIDE DOWN 100 KPH COMPLIANT 9 UNITS REQUIRED. A AND B IN THE CORRECT ORDER 9

COMPLIANT AND DANGEROUS CONNECTIONS OF JJ BARRIERS TO THE TRITON CRASH END TERMINALS DANGEROUS COMPLIANT CONNECTED USING RE BAR... NOTE DOES NOT EVEN GO THRU THE LOWER EYE DANGEROUS ADAPTOR BOLTED TO BARRIER COMPLIANT CONNECTION 10

NON COMPLIANT END TERMINAL ATTACHMENTS COMPLIANT END TERMINAL CUSTOM TRANSITION TERMINAL NO TRANSITION TERMINAL POSITIVE CONNECTION NO POSITIVE CONNECTION BUTT JOINTED TWO DIFFERENT BARRIERS B.S DEVELOPMENTS JJ BARRIER WITH ABSORB 350 TERMINAL 11

B.S DEVELOPMENTS JJ BARRIERS SH 29 KAIMAI TAURANGA LEADING EDGE FLARE NO END TERMINAL B.S DEVELOPMENTS JJ BARRIERS SH 1 SILVERDALE NO END TERMINALS...SIDE ROAD EED FOR EXEMPTION FOR END TERMINAL...SPEED RESTRICTION. TAPER AS PER COPTTM NO END TERMINAL SIDE ROAD ACCESS REQUIRED..EED EXEMPTION 12

SH 1 NORTHERN GATEWAY PUHOI TUNNEL CONSTRUCTION ROAD WIDENING 50kph 50kph TSR MINIMUM LANE WIDTH 3M EED SOUGHT FOR BARRIER OFFSET MIN LANE WIDTH 3 M HIT POSTS AS CENTRE LINE DELINEATION...EED APPROVED 13

B. S DEVELOPMENTS JJ BARRIERS SITE PROTECTION OF DEEP EXCAVATIONS SH 20 B PUHINUI RD NEW OVER BRIDGE DEEP EXCAVATION PROTECTION 30KPH SPEED RESTRICTION 1M PLUS EXCAVATION 3.6M AND 6 M BARRIERS USED AROUND THE CORNER 1M PLUS EXCAVATION TAUPO SH 1 NEW BYPASS DEEP EXCAVATION WIDENING OF INTERSECTION 30KPH SPEED RESTRICTION. 14

B.S DEVELOPMENTS JJ BARRIERS NCHRP350 TL3 B.S DEVELOPMENTS JJ BARRIERS NCHRP350 TL3 BARRIERS SH 1 DOME VALLEY WARKWORTH SH 29 KAMAI S TAURANGA COMPLIANT INSTALLATIONS SHOULDER CLOSURE ABSORB 350 TERMINAL LEADING END 300MM OFFSET FROM PAINTED EDGELINE 80KPH SPEED RESTRICTION 3.5M LANE WIDTHS 3.5M LANE WIDTHS END TERMINAL TRAILING END ADDED PROTECTION 15

B.S DEVELOPMENTS JJ BARRIER NCHRP 350 B.S DEVELOPMENTS JJ BARRIER NCHRP350 NO END TERMINAL BARRIER TAPERED END MORE THAN 5 M FROM EDGE LEADING END BARRIER SYSTEM GOING AROUND THE CORNER 3.6M BARRIERS AND 6M BARRIERS USED ABSORB 350 WITH TRANSITION TO JJ BARRIER SYSTEM. 16

SITE PROTECTION. SH 1 NORTHERN GATEWAY PUHOI TUNNELL 3.6M JJ HOOKS UNITS 80KPH TSR 80 KPH SPEED RESTRICTION 17

BARRIER INSTALLATION METHODS 12 T DIGGER MIN FOR 3.6M BARRIERS 20T DIGGER FOR 6 M BARRIERS WALKER BARRIER HIRE AUCKLAND HIAB TO PLACE 3.6M AND 6M UNITS UTILISING A DIGGER TO INSTALL 18

Lifting and placement methods...(min 2 person operation) for safety Chains...( using a hiab digger or crane) The barriers can be lifted vertically by utilising the two swiftlift conncections found on the top of the barrier systems. SPECIAL NOTE...CORRECT LIFTING REQUIREMENT. The chains to lift the barriers when using chains and the swif lift connectors the chains should be @ 60 degrees...an angle less that 60 degrees will damage the swift lifts. Spreader Bar.(using a hiab digger or crane) Utilising the swift lift and chains with a spreader bar allows the lifting chains to be located directly above the lifting eyes..( Optimum lift.) Using chains allows alignment and shortening of one end to install on sloping ground. Friction clamp. KENCO or other frictions clamps can be utilised however caution when lifting painted barriers in the wet. A safety chain around the barrier may be required and attached to the lifter seperately This system inhibits adjustment for installing on sloping ground. 19

20

21

22