TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

KG7T (E and N Series)

FG7T (E and N Series)

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FG7T (A and K Series)

KG7S (A and K Series)

FG7S (C and L Series)

FG7T (A and K Series)

AF90. AF90 Gas Furnace High Efficiency. Features

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

G8MVL. Product Specifications

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

Product Data. that this product meets the S 95% AFUE S Two -stage operation

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

93% Gas Furnaces Single Stage

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

F8MTL. Product Specifications

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Multi-Position, Multi-Speed Gas Furnaces

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

DF6SF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 4-Stage Heat/2-Stage Cool with Variable Speed Blower ihybrid Package Units with R-410A

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Table of Contents GF801U Series

80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Rheem Value Series Downflow Gas Furnace

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

96% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GMS9/GCS9 SERIES 93% AFUE

Cooling Capacity CFM in. w.c. (125 Pa)

UPFLOW/ HORIZONTAL GAS FURNACE

Rheem Classic Series Upflow/Horizontal Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

97% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

G9MXE. Product Specifications

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN

G23 Bulletin # September 1998 Supersedes June 1995

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

P5RF Series Single Packaged Air Conditioner Single Phase

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

G9MXE. Product Specifications

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

N9MPD Product Specifications

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

TSTAT0101SC Recommended (sold separately)

Unit Dimensions FITS-ALL 80 Upflow, Horizontal and Downflow 50,000 thru 125,000 Btu Inputs DUCANE FITS-ALL 80 FURNACE SPECIFICATIONS Length Width Heig

Cooling Capacity CFM in. w.c. (125 Pa)

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

Rheem Classic Series Downflow Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

Rheem Value Series Upflow/Horizontal Gas Furnace

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Transcription:

TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. Upflow/Horizontal units come ready for upflow or horizontal application. The extended flush jacket provides a pleasing appliance appearance. Design certified by CSA for application in Canada and the United States. WARRANTY 10 Year all-parts warranty. 1 Year Quality Pledge to replace the unit if the heat exchanger fails within the first 1 year of operation, to the original owner. Consumer product registration required for 10 year All Parts Warranty and Quality Pledge within a limited period of time after the installation. See current warranty document or visit our consumer web site listed on the back of this document for warranty details. When registered, this product is upgraded to a limited lifetime heat exchanger warranty. FEATURES and BENEFITS 100% fired and tested: All units and each component are tested on the manufacturing line. Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free. 30 second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). 30 second post purge: Increases life of heat exchanger. Hot surface igniter: Innovative application of an appliance type igniter with a 20 year history of reliability. Utilizes proven Smartlite technology. Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation. High Static Blowers: All models equipped with high static blowers. Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life. 90 second fixed cooling cycle blower-off delay (TDR): Increases cooling performance when matched with a NORDYNE coil. Variable speed blower kit: Upgradable to full variable speed with kit. LP convertible: Simple burner orifice and regulator spring change for ease of convertibility. Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes. Incorporates integrated control board: With connections for electronic air cleaner and humidifier. Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws. Sealed vestibule: Reduces burner and inducer sound levels. Energy efficient brushless DC (ECM) motor: Gives up to 1 SEER point efficiency gain in cooling.

1 2 3 4 5 6 7 8 LOCATION OF FURNACE COMPONENTS Flame Sensor Finish Flange Roll-Out Switch Burner Assembly Pressure Switches (Inducer) Igniter Main Air Limit Switch Inducer Limit Switch AIR FLOW Gas Valve Furnace Control Board Inducer Assembly Blower Door Switch Pressure Switches (Condensate) Transformer Motor Control Box Motor Choke (C & D cabinets only) Motor Control Board Blower Assembly Upflow/Horizontal Gas Furnace Components Blower Assembly (behind blower panel) Motor Choke (C & D cabinets only) Finish Flange Furnace Control Board Motor Control Board Blower Door Switch (behind blower panel) Vent Limit Switch AIR FLOW 1 2 3 4 5 6 7 8 Transformer Pressure Switches Inducer Assembly Gas Valve Igniter Main Air Limit Switch Flame Sensor Burner Assembly Roll-Out Switch Gas Manifold Downflow Gas Furnace Components 2

DIMENSIONS *TC 95.1% Upflow/Horizontal Furnace Cabinet Size A B C B Cabinet 17 1/2 15 7/8 16 1/8 C Cabinet 21 19 3/8 19 5/8 D Cabinet 24 1/2 22 7/8 23 1/8 NOTES: Dimensions shown in inches. TOP VIEW B FLANGES 19 23 1/2 BOTTOM VIEW C Front Brace Bottom Panel 3 1/4 Combustion Air 34 1/2 2 3/4 25 3/8 Vent pipe (Ø 3 ) 17 1/4 T-stat Electric Gas (Ø 1 5/8) 17 7/8 A T-stat Vent pipe (Ø 3 ) 24 7/8 1 Electric Gas (Ø 1 5/8) 4 Knockouts (both sides) Cond. (Ø 1 1/16) 15 28 LEFT SIDE Condensate (Ø 1 1/16) FRONT VIEW 23 RIGHT SIDE 1 1/4 *TL 95.1% Downflow Furnace TOP VIEW BOTTOM VIEW Cabinet Size A B C B Cabinet 17 1/2 15 7/8 16 1/8 C Cabinet 21 19 3/8 19 5/8 D Cabinet 24 1/2 22 7/8 23 1/8 NOTES: Dimensions shown in inches. Flue B FLANGES 3 19 Combustion Air 7 1/2 18 1/2 C Front Brace 34 1/2 28 25 1/4 22 1/4 25 1/2 Vent pipe (Ø 3 ) Cond. (Ø 1 1/16) 10 1/4 Electric Gas (Ø 1 5/8) 17 1/4 A T-stat Electric Gas (Ø 1 5/8) 17 1/4 22 1/4 25 Vent pipe (Ø 3 ) 25 3/8 Cond. (Ø 1 1/16) 17 7/16 29 1/2 LEFT SIDE FRONT VIEW RIGHT SIDE 3

MODEL IDENTIFICATION CODE KG 7 T C 090 C 23 B Gas Furnace Design Series Cabinet Width B = 17.50 C = 21.00 D = 24.50 S = Single Stage T = Two Stage A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal K = 80% Downflow L = 92.1% / 95.1% Downflow Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons V = VSB Input Heating Capacity 060 = 60,000 080 = 80,000 100 = 100,000 120 = 120,000 C = Standard D = 90+% AFUE Low NOx SPECIFICATIONS KG7TC/TL MODEL NUMBERS: -060D-23B -080D-35C -100D-35C -120D-45D Input - Btuh (a) 60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 120,000 / 78,000 Heating Capacity - Btuh 57,000 / 37,050 76,000 / 49,400 95,000 / 61,750 114,000 / 74,100 AFUE 95.1 95.1 95.1 95.1* Blower D x W 11 x 8 11 x 10 11 x 10 11 x 10 Motor H.P. - Speed - Type 1/2 - BLDC 3/4 - BLDC 3/4 - BLDC 1 - BLDC Motor FLA 6.2 8.7 8.7 11.7 Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5 Temperature Rise Range - ºF 30-60 35-65 35-65 40-70 Shipping Weights 125lbs 135lbs 145lbs 160lbs *TL 120 is 94.8% AFUE Note: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level. 4

BLOWER PERFORMANCE - KG7TC/TL Model Number Heating Input (Btuh) *TC/TL-060D-*B 60000 *TC/TL-080D-*C 80000 Motor Switch Setting KG7TC/TL - 95.1% AFUE, Two Stage Gas Furnace External Static Pressure (in.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise 0 0 0 0 1 0 0 0 0 1 0 0 1 1 0 0 725 73 0 0 1 0 810 65 1 0 1 0 940 56 890 59 845 62 795 66 750 70 700 75 0 1 1 0 990 53 945 56 905 58 860 61 820 64 775 68 735 72 690 76 1 1 1 0 1055 50 1015 52 970 54 930 57 890 59 845 62 805 66 760 69 0 0 0 1 1135 47 1095 48 1055 50 1010 52 960 55 930 57 890 59 850 62 1 0 0 1 1185 45 1145 46 1105 48 1065 50 1030 51 990 53 950 56 910 58 0 1 0 1 1250 42 1210 44 1170 45 1135 47 1095 48 1055 50 1020 52 980 54 1 1 0 1 1290 41 1255 42 1220 43 1180 45 1145 46 1110 48 1075 49 1040 51 0 0 1 1 1315 40 1275 41 1240 43 1200 44 1160 45 1120 47 1085 49 1045 51 1 0 1 1 1350 39 1315 40 1280 41 1245 42 1205 44 1170 45 1135 47 1100 48 0 1 1 1 1390 38 1350 39 1315 40 1275 41 1240 43 1200 44 1160 45 1125 47 1 1 1 1 1420 37 1380 38 1345 39 1310 40 1270 42 1235 43 1200 44 1160 45 0 0 0 0 1125 55 1040 68 960 73 880 80 795 89 1 0 0 0 1205 58 1120 63 1040 68 960 73 875 80 795 89 0 1 0 0 1305 54 1225 57 1150 61 1070 66 995 71 915 77 840 84 1 1 0 0 1430 49 1350 52 1270 55 1190 59 1110 63 1030 68 950 74 865 81 0 0 1 0 1525 46 1450 49 1375 51 1300 54 1225 57 1150 61 1075 65 1000 70 1 0 1 0 1620 43 1540 46 1465 48 1390 51 1315 54 1240 57 1165 60 1090 65 0 1 1 0 1695 42 1620 43 1545 46 1465 48 1390 51 1315 54 1235 57 1160 61 1 1 1 0 1770 40 1700 41 1630 43 1555 45 1485 47 1410 50 1340 53 1265 56 0 0 0 1 1875 38 1805 39 1730 41 1655 43 1580 45 1510 47 1435 49 1340 53 1 0 0 1 1905 37 1840 38 1775 40 1710 41 1640 43 1575 45 1510 47 1445 49 0 1 0 1 1980 36 1910 37 1845 38 1780 40 1715 41 1650 43 1580 45 1515 46 1 1 0 1 2025 35 1960 36 1895 37 1830 38 1765 40 1700 41 1635 43 1570 45 0 0 1 1 2085 34 2025 35 1960 36 1900 37 1840 38 1775 40 1715 41 1655 43 1 0 1 1 2135 33 2070 34 2010 35 1945 36 1880 37 1815 39 1750 40 1685 42 0 1 1 1 2200 32 2145 33 2090 34 2035 35 1980 36 1925 37 1870 38 1820 39 1 1 1 1 2280 31 2225 32 2170 32 2115 33 2065 34 2010 35 1955 36 1900 37 Notes: 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended. 5

BLOWER PERFORMANCE - KG7TC/TL Continued Model Number Heating Input (Btuh) *TC/TL-100D-*C 100000 *TC/TL-120D-*D 120000 Motor Switch Setting KG7TC/TL - 95.1% AFUE, Two Stage Gas Furnace External Static Pressure (in.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise 0 0 0 0 1125 78 1040 85 1 0 0 0 1205 73 1120 79 1040 85 0 1 0 0 1305 67 1225 72 1150 76 1070 82 995 88 1 1 0 0 1430 62 1350 65 1270 69 1190 74 1110 79 1030 85 0 0 1 0 1525 58 1450 61 1375 64 1300 68 1225 72 1150 76 1075 82 1000 88 1 0 1 0 1620 54 1540 57 1465 60 1390 63 1315 67 1240 71 1165 76 1090 81 0 1 1 0 1695 52 1620 54 1545 57 1465 60 1390 63 1315 67 1235 71 1160 76 1 1 1 0 1770 50 1700 52 1630 54 1555 57 1485 59 1410 62 1340 66 1265 70 0 0 0 1 1875 47 1805 49 1730 51 1655 53 1580 56 1510 58 1435 61 1340 66 1 0 0 1 1905 46 1840 48 1775 50 1710 51 1640 54 1575 56 1510 58 1445 61 0 1 0 1 1980 44 1910 46 1845 48 1780 49 1715 51 1650 53 1580 56 1515 58 1 1 0 1 2025 43 1960 45 1895 46 1830 48 1765 50 1700 52 1635 54 1570 56 0 0 1 1 2085 42 2025 43 1960 45 1900 46 1840 48 1775 50 1715 51 1655 53 1 0 1 1 2135 41 2070 42 2010 44 1945 45 1880 47 1815 48 1750 50 1685 52 0 1 1 1 2200 40 2145 41 2090 42 2035 43 1980 44 1925 46 1870 47 1820 48 1 1 1 1 2280 39 2225 40 2170 41 2115 42 2065 43 2010 44 1955 45 1900 46 0 0 0 0 1395 76 1350 78 1305 81 1260 84 1210 87 1165 91 1120 94 1 0 0 0 1465 72 1420 74 1375 77 1330 79 1290 82 1245 85 1200 88 1155 91 0 1 0 0 1555 68 1510 70 1470 72 1425 74 1380 76 1340 79 1295 82 1250 84 1 1 0 0 1625 65 1585 67 1540 69 1500 70 1460 72 1415 75 1375 77 1335 79 0 0 1 0 1690 62 1650 64 1610 66 1570 67 1530 69 1485 71 1445 73 1405 75 1 0 1 0 1760 60 1715 62 1670 63 1625 65 1575 67 1530 69 1485 71 1440 73 0 1 1 0 1835 58 1790 59 1745 60 1695 62 1650 64 1605 66 1555 68 1510 70 1 1 1 0 1885 56 1840 57 1790 59 1745 60 1700 62 1655 64 1610 66 1565 67 0 0 0 1 1945 54 1900 56 1850 57 1805 58 1760 60 1710 62 1665 63 1620 65 1 0 0 1 1950 54 1905 55 1860 57 1820 58 1775 59 1735 61 1690 62 1650 64 0 1 0 1 2075 51 2030 52 1990 53 1945 54 1900 56 1855 57 1810 58 1770 60 1 1 0 1 2125 50 2085 51 2040 52 2000 53 1955 54 1910 55 1870 56 1825 58 0 0 1 1 2170 49 2130 50 2090 51 2045 52 2005 53 1965 54 1925 55 1880 56 1 0 1 1 2215 48 2180 48 2140 49 2105 50 2070 51 2035 52 2000 53 1965 54 0 1 1 1 2225 47 2165 49 2100 50 2040 52 1 1 1 1 2170 49 2120 50 2065 51 Notes: 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are recommended for airflows above 1600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Temperature rises that are shaded in grey are for reference only. These conditions are not recommended. 6

VENTING All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths. VENT TABLE FURNACE MODELS (BTU) FURNACE INSTALLATION SINGLE PIPE LENGTH (FT.) with 1 long radius elbow** DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH 1 long radius elbow on each pipe** OUTLET OUTLET INLET/OUTLET INLET/OUTLET 2 Diameter 3 Diameter 2 Diameter 3 Diameter Upflow 90 90 90 90 60,000 Horizontal 50 90 50 90 Downflow 30 90 30 90 Upflow 40 90 40 90 80,000 Horizontal 30 90 30 90 Downflow 30 90 30 90 Upflow 30 90 30 90 100,000 Horizontal 30 90 30 90 Downflow 30 90 25 90 Upflow N/A 90 N/A 90 120,000 Horizontal N/A 90 N/A 90 Downflow N/A 90 N/A 90 *NOTES: 1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2 tee and 8ft for each 3 tee. 2. Two 45 degree elbows are equivalent to one 90 degree elbow. 3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude. 7

ACCESSORIES KG7TC/TL KITS Description SKU Fixed speed -to- variable speed 904880 2" Concentric vent kit 904952 3" Concentric vent kit 904953 "A" Cabinet downflow sub base kit 902974 "B", "C", "D" Cabinet downflow sub base kit 904911 2" Side wall vent kit 904617 3" Side wall vent kit 904347 U.S. LP Conversion kit (0 to 10,000 ft.) 905028 Canada LP Conversion kit (0 to 4,500 ft.) 905029 Bottom return filter 20 per box, "A" cabinet 903088 Bottom return filter 20 per box, "B" cabinet 904916 Bottom return filter 20 per box, "C" cabinet 904917 Bottom return filter 20 per box, "D" cabinet 904918 Side return filter kit 541036 Neutralizer kit 902377 GENERAL TERMS OF LIMITED WARRANTY NORDYNE will furnish a replacement for any part of this product which fails in normal use and service within the first ten years of installation, in accordance with the terms of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy. 8000 Phoenix Parkway O'Fallon, MO 63368-3827 Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (11/2012) 835C-1112 (Replaces 835C-0112)