Charging the NESS H200 Wireless System

Similar documents
Setting Up the NESS L300 Plus System

Maintenance and Cleaning

Maintenance and Cleaning

When the RF Stim Unit is fully charged, the status light on the RF Stim Unit will be solid GREEN.

1. Connect the Tester to the L300 FS Cuff plug holes. See Figure Figure 11-1: Tester connected to the L300 FS Cuff.

Rx Only Rev. C

Manufactured by Bioness Neuromodulation Ltd. A Bioness Inc Company 19 Ha Haroshet Street PO Box 2500 Industrial Zone Ra Anana 43654, Israel

Rx Only Bioness Inc Rev. C 07/2017

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Model Ci. Intelligent Personal EV P 1 P 3 P 4 P 5 P 6 P 7. Assembly. Basic Insructions. iphone App. Freewheel Mode. Charging.

Powered Air Purifying Respirator (PAPR) System

The Bio Tuner. Model BT6pro Manual. Contents Welcome to SOTA... 2 Before Using... 2 Learn More... 2 Complete unit includes... 2 do not use...

Installation, Usage & Maintenance Guide

BlueFin User's Manual. Version 1.1

1. Safety. Contents. Warning: The Maxi-Cosi Pearl can ONLY be used on a Maxi-Cosi FamilyFix base with IsoFix.

Agilent G1554A On-Column Capillary Inlet with EPC

INSTRUCTION MANUAL HI 921 AUTOSAMPLER

HP10207 KIT. Ram WD*

Instruction Manual UK

with Instruction Manual

WARNING. This shows the detail that could lead to death or severe injury if ignored or through misuse the product.

PAPRV. Powered Air Purifying Respirator (PAPR) System. Please read these instructions carefully before using this unit. affect your health and safety.

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION

Setting Instructions for Movement Caliber B230 Contents

Vercise TM DBS Charging Handbook

Instructions for SOTA Magnetic Pulser - Model MP5

Table of ConTenTs. Analog Chronographs 1/1 of a Second - Type C with small chronograph seconds and 24-hour hands 15

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

c-go 24V/6A 24V/8A 24V/12A

King Dream Assembly Instructions

PDF created with FinePrint pdffactory trial version

Fabric Replacement Top and Doors with Tinted Side and Rear Curtains Installation Instructions

Using the Universal Pendant with Patient Cable

The Magnetic Pulser. Model MP5 Manual CONTENTS

Model: SW02 Advanced OPERATING MANUAL

(H) TOUR VANTAGE STROLLER ASSEMBLY INSTRUCTIONS ADULT ASSEMBLY REQUIRED. Styles and colors may vary

S-Drive Performance Trainer

Practical Training Session

Child Safety ! WARNING: GENERAL SAFETY INFORMATION

Polar WearLink 31 CODED TRANSMITTER. User Manual. Gebrauchsanleitung. Manuel d'utilisation. Gebruiksaanwijzing. Manuale dell utente

U-Step 2 Platform Model

User Guide MDS86850E MDS86850EB Rollator

TELESCOPIC LADDER MODEL NO: TL-2B / TL-3B

SEAT BELTS SECTION CONTENTS H RESTRAINTS SB-1

the game company ENGLISH Manual JAHRE YEARS ANS V

B-RAD Select USER MANUAL TABLE OF CONTENTS

XeVision XeRay XV-LX50 HID Searchlight

All-in-One Hoist User Manual , , ,

ROHO AGILITY Back System Quick Release Hardware Operation Manual

The Magnetic Pulser. Model MP6 Manual CONTENTS

INSTALLATION MANUAL SWS

expandable booster Instruction Manual US Version

Instruction Manual. Canada English Version

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

Advancement Chair. R901, R902, & R903 Product Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

Full Top Deck Kit. Installation Instructions

Keeler Spectra Plus. Instructions. Next

SR500 PAPR How to Copyright 2015 by The S.E.A. Group 1

Booster Car Seat User Guide

746 Wrist Strap Tester Installation, Operation and Maintenance

Fastback Top Installation Instructions and Owner s Manual

Zeiss ZAT Cube Assembly Procedure

2 in 1 Rollator and Transit Chair M58203

CONVERTIBLE CAR SEAT ISOFIX COMPATIBLE Birth to 4 years (approx)

Installation Instructions: Epson 1400 CFS

User Manuel. Titan Hummer XL

Chapter 52 DOORS -Title

dogtrd Owner's Manual Remote Controlled Dog Training Collars dogtrд 2ЗООNСР Advance Series

HD 7700 Setup & Operator Manual

INSTALLATION INSTRUCTIONS

SO-801 HAND-HELD SLIT LAMP SO-801

expandable booster Instruction Manual US Version

ROHO AGILITY Back SystemDirect Mount Hardware Operation Manual

EN Operator's manual PRLM21i

Installation Guide Current Ford F-250 & Ford F-350 Super Duty. Product Code: 109 & 119

Portable Metal Detectors By: MODEL P-4000 MANUAL PORTABLE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions Headliner

i-mop XL OPERATOR MANUAL

Service manual Be-Ge 3000

24V HEAVY DUTY JUMP STARTER/ POWER BANK MB3752. Storage. Specifications

LED HANDHELD SLIT LAMP

MODEL SST1 JOGGER/BIKE TRAILER. Owner s Manual should be kept for future reference

CHARGE TANK. Overview. Using The Charge Tank. User Guide

Occupant Protection ! WARNING: FASTENING THE SEAT BELTS

SAFETY GUIDE...4 PRECAUTION...4 PRODUCT CHARACTERISTICS...5 SPECIFICATION...5 MODEL...6 SIZE AND NET WEIGHT...7 OPERATION...8

NILFISK BA 500 Service Manual

REMOTE CONTROLLED DOG TRAINING COLLARS

Operating Instructions. TEK 678 Display Unit with remote and 10 bar display

WirelessAIR Advanced Integrated Remote

2005 Freestyle/Five Hundred/Montego Workshop Manual

TOYOTA HIGHLANDER 2016 ON BOARD VACUUM CLEANER

Pallas/150. Stand-aid lifter. User instruction. Important - information. This user instruction must be read before the Pallas 150 is used.

SawStop Quick Start Guide

LinidoSolutions wall mounted bathroom safety aids and accessories May

7 Handle Tubes. 10 Charging Jack 11 LED Indicator 12 ON/OFF button

Warning! General Maintenance 4-11

Operating Instructions for Porsche Junior Seat ISOFIX

Cybex Arc Trainer Owner s & Service Manual. 7 - Service

Transcription:

Setup Instructions Chapter 8 Charging the NESS H200 Wireless System It is important to charge your H200 Wireless System daily and for at least four hours before a fitting/programming session. Bioness recommends charging the Control Unit and the Orthosis at the same time. To charge the NESS H200 Wireless System: 1. Select the interchangeable blade that matches your power outlet. Four blades are provided for use in the US, the European Union, Australia, and the United Kingdom. See Figure 8-1. Figure 8-1: System charger interchangeable blades. Chapter 8 - Setup Instructions 51

2. Slide the selected blade into the system charger. See Figure 8-2. Blade System Charger Figure 8-2: Sliding the blade into the system charger. CAUTION: Use only the charger included in your H200 Wireless System Kit. Use of any other charger could damage the system. 52 User's Guide

3. Connect the Y cable to the charging ports of the Orthosis and Control Unit. The Control Unit charging port is under the flexible cover. See Figure 8-3. Charging Port Flexible Cover Y Cable Charging Port System Charger Interchangeable Blade Figure 8-3: Charging setup. CAUTION: Make sure your hands are dry before connecting the system charger to a power outlet. Chapter 8 - Setup Instructions 53

4. Plug the system charger into a power outlet. 5. If the Control Unit is charging, a rotating GREEN circle will appear in the Control Unit digital display. See Table 8-1. Control Unit Display Description Rotating GREEN Circle in Digital Display Horizontal GREEN Line in Digital Display Status Light is SOLID RED Definition Battery Charging Battery Fully Charged Charging Error Table 8-1: H200 Wireless Control Unit charging displays. 54 User's Guide

6. If the Orthosis is charging, the status light on the Orthosis will ALTERNATELY FLASH YELLOW and GREEN. See Table 8-2. Orthosis Display Description Status Light ALTERNATELY FLASHES YELLOW and GREEN Status Light is SOLID GREEN Definition Battery Charging Battery Fully Charged Table 8-2: H200 Wireless Orthosis charging displays: left Orthosis. The charging process is complete when: A horizontal GREEN line appears in the Control Unit digital display. The status light on the Orthosis is solid GREEN. The charging process should last approximately four hours. The Control Unit can take up to six hours to charge. Note: Keep the Control Unit and Orthosis connected to the system charger until ready for use. Chapter 8 - Setup Instructions 55

Checking the System Components Before using your H200 Wireless System: Visually inspect the Orthosis and Control Unit for signs of damage. The cloth electrodes must be replaced every two weeks. If the cloth electrodes are old or damaged discard them. Open a new set of cloth electrodes. Open the Orthosis and check the electrode bases to see if they are clean. If necessary, clean the electrode bases. See the Maintenance and Cleaning chapter of this guide. Make sure your Orthosis and Control Unit are charged. Do not use your H200 Wireless System if a component appears to be damaged. If you have any questions about your H200 Wireless System, contact the Bioness Client Relations Department at (800) 211-9136, Option 3. CAUTION: Extreme temperatures may damage your system. Store your H200 Wireless System where it will not be exposed to extreme temperatures or humidity. See the environmental ranges in the Technical Specifications chapter of this guide for safe storage conditions. 56 User's Guide

Preparing Your Skin Before putting on your Orthosis, always check your skin for signs of irritation. If any irritation is present, do not put on the Orthosis and contact your clinician. Wait for complete healing before using the NESS H200 Wireless System. For optimal stimulation, the skin under the Orthosis should be clean and healthy. To prepare the skin: 1. Remove any jewelry from your hand, wrist, and forearm. 2. Clean the skin where the cloth electrodes will touch with a wet washcloth. If any lotions are on the skin, clean the skin with soap and water. Rinse well. 3. If necessary, trim excess body hair from the area using an electric shaver or scissors. Do not use a razor. A razor can irritate the skin. CAUTION: Do not wear the Orthosis over broken skin. Chapter 8 - Setup Instructions 57

Wetting/Attaching the Cloth Electrodes 1. Make sure the H200 Wireless System is turned off. 2. Place the Control Unit where it cannot be splashed. 3. Wet the cloth electrodes until they are saturated. See Figure 8-4. Figure 8-4: Wetting the cloth electrodes. CAUTION: Before wetting the cloth electrodes, always remove them from the Orthosis. 58 User's Guide

4. Blot excess water from the cloth electrodes. See Figure 8-5. Figure 8-5: Blotting the cloth electrodes. Note: Remove and rewet the cloth electrodes every time you remove the Orthosis from your arm for more than one hour, and after every three to four hours of use. If the cloth electrodes dry out, your response to the stimulation may change. If you need to adjust stimulation intensity more often than usual, try rewetting the cloth electrodes. CAUTION: Use only cloth electrodes supplied by Bioness Inc. Chapter 8 - Setup Instructions 59

5. Match each cloth electrode to its corresponding electrode base. See Figure 8-6. Electrodes Base #1 Electrode Base #2 Electrode Base #3 (Thenar) Electrode Base #5 Electrode Base #4 Figure 8-6: Electrode bases #1 #5. 60 User's Guide

6. Snap cloth electrode #3 to the thenar. Note: The #3 large cloth electrode is for large thenars. 7. For cloth electrodes #1, 2, 4, and 5, face the white dot on the cloth electrode toward the electrode base. Insert the corners of the cloth electrode into the electrode base. See Figure 8-7. Figure 8-7: Inserting the #5 cloth electrode into the #5 electrode base. Chapter 8 - Setup Instructions 61

8. Check that each cloth electrode is securely attached to its corresponding electrode base. See Figure 8-8. Figure 8-8: Cloth electrodes in place on the Orthosis. CAUTION: Do not wear the Orthosis without the cloth electrodes. 62 User's Guide

Putting on the Orthosis Make sure you are sitting upright and centered (not leaning to one side). Your arm should be comfortable and your shoulder relaxed. To put on the Orthosis: 1. Position the Orthosis on a stable surface, and place your hand in the spiral end of the Orthosis. The #3 thenar cloth electrode should rest at the base of your thumb. See Figure 8-9. Figure 8-9: Positioning the thenar. Chapter 8 - Setup Instructions 63

2. Position the Orthosis wrist bridge comfortably on the back of your wrist. See Figure 8-10. Wrist Bridge Figure 8-10: Positioning the wrist bridge. WARNING: Do not turn on stimulation until your Orthosis is completely set up and correctly attached to your arm. 64 User's Guide

3. Place your forearm in the Orthosis flexor support. See Figure 8-11. Flexor Support Figure 8-11: Positioning the flexor support. Chapter 8 - Setup Instructions 65

4. Place your hand on top of the wing arm and grasp under the extensor wing with your fingers. 5. Pull the extensor wing out while pushing down on the wing arm. See Figure 8-12. Push down until no more clicking can be heard. Extensor Wing Wing Arm Wing Release Handle Figure 8-12: Closing the wing. 66 User's Guide

6. Attach the hook on the Orthosis wrist strap to the wrist strap attachment ring. See Figure 8-13. Wrist Strap Attachment Ring Wrist Strap Hook Figure 8-13: Attaching the Orthosis wrist strap. Chapter 8 - Setup Instructions 67

7. Bring the wrist strap under the wrist. Make sure the cushion on the wrist strap is touching the wrist. 8. Pull the wrist strap up and through the wrist strap attachment bar. See Figure 8-14. Wrist Strap Attachment Bar Wrist Strap Cushion Figure 8-14: Attaching the wrist strap. 9. Bring the wrist strap down and press to fasten. CAUTION: Do not pull down on the wrist strap. Pulling down on the wrist strap can break the wrist strap attachment bar. CAUTION: Do not tighten the wrist strap so much that it interferes with blood flow to the hand. 68 User's Guide