DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

Similar documents
DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DTG Commercial. 3-5 Tons Gas/ Electric Units Up to 15.5 SEER and 13.0 EER Up to 81% AFUE

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DTC Commercial. 3-5 Tons Packaged Air Conditioner Up to 15.5 SEER / Up to 13.0 EER. Cooling Capacity: 35,600 60,000 BTU/h

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

DCH Commercial Contents Standard Features Cabinet Features

DCC Commercial. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER. Cooling Capacity: 88, ,000 BTU/h

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

CPG Commercial. 7½- to 12½-Ton Self-Contained Packaged 80% AFUE. Cooling Capacity: 90, ,000 BTU/h. Gas/Electric Units. up to 11.

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase Split System Air Conditioner. Cooling Capacity: 36,000-60,000 BTU/h

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E.

DP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h

DX13S Commercial. 3-, 4-, & 5-Ton, Three-Phase. Cooling Capacity: 36,000-60,000 BTU/h

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

High-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger

GPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DX11S Commercial & 10-ton, Three-Phase Split System Air Conditioner 11.2 EER / R-410A. Plus

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

Packaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

GSX SEER / 1½ to 5 Tons. Split System Air Conditioner. 18,000-60,000 BTU/h

GPH13M. 13 SEER / R-410A 2 to 5 Tons

2- to 5-Ton. Cooling Capacities: 23,600 to 57,000 BTU/h. Packaged Gas/Electric Units. Heating Capacities: 46,000 to 138,000 BTU/h

DZ11S Commercial. Plus & 10-Ton, Three-Phase Split System Heat Pump with One Two-Speed Indoor Air Handler and Two 4-Ton or Two 5-Ton Condensers

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

GPG13 SINGLE-PHASE, SELF-CONTAINED

DP14HM Commercial 3-5 TON THREE-PHASE PACKAGED HEAT PUMPS 14 SEER. Cooling Capacity: 34,400-58,000 BTU/h Heating Capacity: 33,200-57,000 BTU/h

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

GPC13M R-410A, 13 SEER. Packaged Air Conditioner. 3, 4, & 5 Tons. Cooling Capacity: 36,000-56,000 BTU/h

DX18TC. High-Efficiency, ComfortNet -Compatible, Split System Air Conditioner Up to 19 SEER. Cooling Capacity: 34,600-58,000 BTU/h

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

DP13CM. Packaged Air Conditioner 3, 4, & 5 Tons / 13 SEER. Cooling Capacity: 36,000-56,000 BTU/h

SSX16 PRODUCT SPECIFICATIONS 16 SEER / R-410A 2 TO 5 TONS HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER COOLING CAPACITY 24,000 BTU/H TO 57,000 BTU/H

DSXC18. Split System Air Conditioner. 34,000-56,000 BTU/h

DZ11S Commercial & 10-Ton, Three-Phase

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

ASXC18. High-Efficiency, ComfortNet -Compatible, Split-System Air Conditioner Up to 19 SEER. Cooling Capacity: 24,000-60,000 BTU/h

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPG COMMERCIAL PRODUCT SPECIFICATIONS 13 & 10 SEER 80% AFUE 3, 4, & 5 TON, 3-PHASE SELF-CONTAINED PACKAGED GAS/ELECTRIC

GPG15 Series 80% AFUE. Single-Phase, Self-Contained. up to 15 SEER. Cooling Capacity: 23,200 56,500 BTU/h. Heating Capacity: 69, ,000 BTU/h

DCC Commercial. 15- & 20-Ton, Three-Phase. 15 Tons Cooling Capacity: 180,000 BTU/h 20 Tons Cooling Capacity: 240,000 BTU/h. Packaged Air Conditioners

APD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF

CPG COMMERCIAL 4-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

CPG COMMERCIAL 5-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNIT

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

GPC13M COMMERCIAL PRODUCT SPECIFICATIONS 13 SEER PACKAGED AIR CONDITIONER 3- TO 5-TON COOLING CAPACITY 35,000-56,000 BTU/H

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

CPG COMMERCIAL 10-TON SELF-CONTAINED PACKAGED GAS/ELECTRIC UNITS

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSC13 Split System Air Conditioner

TECHNICAL INFORMATION MANUAL

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

SSZ 16 SEER Split System Heat Pumps

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

TECHNICAL MANUAL. *SZC 18 SEER Split System Heat Pumps

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

SSZ 14 SEER Split System Heat Pumps

TECHNICAL MANUAL. *SZC 16 SEER Split System Heat Pumps

DCC Commercial Tons Packaged Air Conditioners

DCG Commercial. 15- & 20-Ton, Three-Phase

DCG Commercial. 7½- to 10-Ton Three-Phase Packaged Gas/ Electric. Cooling Capacity: 88, ,000 BTU/h Heating Capacity (Output): 144,000 BTU/h

GSZ/VSZ 13 SEER Split System Heat Pumps

AVXC20. High-Efficiency, Comfortnet-Compatible, Variable-Speed, Inverter Drive Split System Air Conditioner. Cooling Capacity : 23,600 53,000 BTU/h

ASPF. Product Specifications. Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

PGC COMMERCIAL PACKAGED GAS/ELECTRIC

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

PACKAGE GAS ELECTRIC UNITS

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

TECHNICAL GUIDE R-410A AFFINITY SERIES DNZ MODELS 2-5 TON 60 Hertz

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 05.16

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

n Heavy-duty, high efficiency compressor n Copper tubing with enhanced fin coils n External service gauge ports CABINET

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

TECHNICAL MANUAL. *PC 14 SEER R-410A Package Air Conditioners with R-410A

PHB SERIES 7-1/2 and 10 TON

Transcription:

DS ommercial - 5 Ton Packaged as/ Electric Units 4 SEE / up to 2.0 EE Up to 8% Efficient ooling apacity: 5,000 58,000 BTU/h Heating apacity: 46,000 8,000 BTU/H ontents Nomenclature... 2 Product Specifications... 4 Expanded ooling Data... Airflow Data... 9 rankercase Heater... 27 Electrical Data... 28 Dimensions... 29 iring Diagrams... for Models with DD ontrols... 5 Accessories... 54 Standard Features Patented tubular heat exchanger High-efficiency scroll compressor High and low-pressure switches opper tube / aluminum fin coils ontactor with lugs High-capacity, steel-cased filter drier 24-volt terminal strip onvertible airflow orientation Easy to service Built-in filter rack with standard 2" filters Bottom utility entry omplies with alifornia Low NOx emissions standards -5 Tons with single speed blower motor units meet the performance specified in Table 6.8.- of ASHAE Standard 90.-20 AHI ertified; ETL Listed abinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter ail Sloped drain pan * omplete warranty details available from your local distributor or manufacturer s representative or at www.daikincomfort.com. SS-DS www.daikinac.com 2/7 Supersedes 8/7

Nomenclature D S 060 090 B * * * A * 2 4,5,6 7,8,9 0 2 4 5 6 evision Levels Major & Minor Brand Factory-Installed Options D Daikin X No Options A Non-powered convenience outlet onfiguration B Powered convenience outlet Standard Efficiency (6-25 Tons) Low-ambient kit S Standard Efficiency ( - 5 Tons) D eturn air smoke detector T High Efficiency ( - 5 Tons) E Supply air smoke detector F Non-powered convenience outlet; Application Low-ambient kit ooling Non-powered convenience outlet; as Heat eturn air smoke detector H Heat Pump H Non-powered convenience outlet; Supply air smoke detector Nominal ooling apacity J Non-powered convenience outlet; 06 Tons 02 8½ Tons 00 25 Tons eturn & Supply air smoke detectors 048 4 Tons 20 0 Tons K Non-powered convenience outlet; 060 5 Tons 50 2½ tons Low-ambient kit; Supply air smoke detector 072 6 Tons 80 5 Tons L Non-powered convenience outlet; 090 7½ Tons 240 20 Tons Low-ambient kit eturn & Supply air smoke detectors Nominal Heating apacity M Powered convenience outlet; as/electric A/ H/P Factory-Installed Electric Heat Low-ambient kit 045 45,000 BTU/h XXX No Heat N Powered convenience outlet; 070 70,000 BTU/h 00 0 k 00 0 k eturn air smoke detector 090 90,000 BTU/h 05 5 k 0 0 k O Powered convenience outlet; 5 5,000 BTU/h 06 5 k 045 45 k eturn & Supply air smoke detectors 40 40,000 BTU/h 08 8 k 046 45 k P Powered convenience outlet; 20 20,000 BTU/h 020 20 k 060 60 k Supply air smoke detector 50 50,000 BTU/h 025 25 k Q Powered convenience outlet; Low-ambient 400 400,000 BTU/h kit; eturn air smoke detector See product specifications for heat size(s) available for each capacity. Powered convenience outlet; Low-ambient Voltage kit; Supply air smoke detector 208-20//60 4 460//60 T Powered convenience outlet; Low-ambient 208-20//60 7 575//60 kit; eturn & Supply air smoke detectors U Non-powered convenience outlet; Supply Fan/Drive Type/Motor Low-ambient kit; eturn air smoke detector B Belt Drive (single speed) V Two-Speed Belt Drive (also designates 6-Ton V Low-ambient kit; eturn air smoke detector D Direct Drive (-5 Tons) with two-stage compressor) Low-ambient kit; Supply air smoke detector H High Static (single-speed Belt Drive models only) Y Low-ambient kit; eturn & Supply Factory-Installed Options air smoke detectors A Ultra Low-Leak Downflow Economizer Ultra Low-Leak Downflow Economizer; Z eturn & Supply air smoke detectors B DD-BAnet protocol DD-BAnet protocol; F Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) DD-BAnet protocol V Low-Leak Downflow Economizer Factory-Installed Options H Disconnect Switch (non-fused) Low-Leak Downflow Economizer X Standard Aluminized Heat Exchanger J Ultra Low-Leak Downflow Economizer; Disconnect Switch (non-fused) S Stainless-Steel Heat Exchanger Disconnect Switch (non-fused) X No Options D Hinged Panels M Disconnect Switch (non-fused); DD-BAnet protocol K Stainless-Steel Heat Exchanger; Hinged Panels Note: Not all options available for all products. B Phase Monitor X= No Options in character th J Stainless Steel Heat Exchanger; Phase Monitor M Hinged Panel; Phase Monitor L Stainless-Steel Heat Exchanger; Hinged Panels; Phase Monitor 2 www.daikinac.com SS-DS

Factory-Installed Options Stainless-Steel Heat Exchanger (as only units): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the - to 6-ton units, cooling operation is extended from 60 F ambient temperature to 5 F outside air temperature. On 7½ -20 ton units, cooling operation is extended from 5 F ambient temperature to 0 F outside air temperature. For 25 ton units, cooling operation is extended from 24 F ambient temperature to 0 F outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. Electric Heat Kits (heat pump and cooling units only): Available in all voltage options. Non-powered onvenience Outlet: A 20V, 5A, FI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered onvenience Outlet: A 20V, 5A, FI outlet powered with a transformer built into the unit. hen a factory-installed powered convenience outlet is installed in the equipment, the unit MA (Min. ircuit Ampacity) will increase by 7.2A/6.5A for 208/20V units, increase by.a for 460V units, and by 2.6A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly. Disconnect Switch (non-fused; -phase units only): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning and heat pump models, the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. eturn Air and/or Supply Air Smoke Detectors: eturn air and/or supply air smoke detectors are installed in the unit. Hinged Access Panels: Allows access to unit s major components. ombined with latches for easy access to control box, compressor, filters and blower motor. Available on all units. Two-speed indoor fan blower models are available on 6, 7½, 8½, 0, 2½, 5, 20 & 25 ton units. Section 6.4..0.b of ASHAE Standard 90.-200 and Section 6.5..2..a of ASHAE Standard 90.-20 require a minimum of two fan speeds. Section 40.4(m) of alifornia Energy ommission Title 24 20 contains a similar provision. hen the units with the two-speed indoor fan blowers operate on a call for the first stage of cooling, the fan operates at low speed, which is 66% of full speed. hen the units operate on a call for the second stage of cooling, the fan operates at full speed. In heating operation, the fan operates at full speed. During ventilation operation, the fan operates at low speed. eturn Air and/or Supply Air Smoke Detectors: eturn air and/or supply air smoke detectors are installed in the unit. Hinged Access Panels: Allows access to unit s major components. ombined with latches for easy access to control box, compressor, filters and blower motor. Available on all models. Phase Monitor: Phase monitor ( phase only), available for - 25 ton DS, D and DT series models. Phase monitor shall provide protection for motors and compressors against problems caused by phase loss, phase reversal and phase unbalance. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. DD ontroller: DD communicating controller, available for - 25 ton DS, D and DT series models with on-board BAnet communication interface. SS-DS www.daikinac.com

Product Specifications Tons DS06 045D***A* DS06 045D***A* DS06 045B***A* DS06 0454B***A* ooling apacity Total BTU/h 6,000 6,000 5,000 5,000 Sensible BTU/h 26,640 26,640 25,600 25,600 SEE / EE 4 / 2 4 / 2 4 / 2 4 / 2 Decibels 78 78 78 78 AHI eference #s 9967 99674 99524 995220 Heating apacity High Input / Output BTU/h 46 / 6.8 46 / 6.8 46 / 6.8 46 / 6.8 Low Input / Output BTU/h ---- ---- ---- ---- Thermal Efficiency (T.E.) ---- 80 80 80 Annual Fuel Utilization Efficiency (AFUE) 8 ---- ---- ---- Temperature ise ange ( F) Hi / Low 25-55 25-55 25-55 25-55 No. of Burners 2 2 2 2 Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal FM,250,250,200,200 Motor Speed Tap (ooling) Low Speed Low Speed --- --- Indoor Motor FLA (ooling) 2.46 2.46.4.7 Horsepower - PM / - 90 / - 90.0-725.0-725 Piston Size (ooling) 0.070 0.070 0.070 0.070 Filter Size (") (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" -40A efrigerant harge ir # (oz.) 05 05 05 05 Evaporator oil Face Area (ft²) 7.0 7.0 7.0 7.0 ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) ---- ---- (" x 0") (" x 0") Motor Sheave ---- ---- VL4 X ⅝ VL4 X ⅝ Blower Sheave / Belt ---- ---- AK6 x / AX5 AK6 x / AX5 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 ¼ -,075 ¼ -,050 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22/4 22/4 Outdoor Nominal FM,800,800,800,800 Face Area (ft²) 7. 7. 7. 7. ows Deep/ Fins per Inch / 24 / 24 / 24 / 24 ompressor Quantity / Type/ Stage / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single ompressor LA / LA 6.7 / 79.0 0.4 / 7.0 0.4 / 7.0 5.8 / 8.0 Electrical Data Voltage-Phase-Frequency 208/20--60 208/20--60 208/20--60 460--60 Indoor Blower HP / FLA / / 2.46 / / 2.46 /.4 /.7 Max. External Static 0.5" 0.5".0".0" Outdoor Fan HP / FLA ¼ /.4 ¼ /.4 ¼ /.4 ¼ / 0.7 Min. ircuit Ampacity¹ 24.7 / 24.7 6.9 / 6.9 7.9 / 7.9 9.6 Max. Overcurrent Protection (amps)² 40 / 40 25 / 25 25 / 25 5 Power Supply onduit Hole.25".25".25.25 Low-Voltage onduit Hole ½" ½" ½" ½" Operating eight (lbs) 565 565 565 565 Ship eight (lbs) 590 590 590 590 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. 4 www.daikinac.com SS-DS

Product Specifications Tons (cont.) DS06 070B***A* DS06 0704B***A* ooling apacity Total BTU/h 5,000 5,000 Sensible BTU/h 25,600 25,600 SEE / EE 4 / 2 4 / 2 Decibels 78 78 AHI eference #s 99524 995220 Heating apacity High Input / Output BTU/h 69 / 55 69 / 55 Low Input / Output BTU/h 5 / 4 5 / 4 Thermal Efficiency (T.E.) 80 80 Annual Fuel Utilization Efficiency (AFUE) ---- ---- Temperature ise ange ( F) Hi / Low 25-55 / 5-45 25-55 / 5-45 No. of Burners Evaporator Motor / oil Motor Type Belt Drive Belt Drive Indoor Nominal FM,200,200 Motor Speed Tap (ooling) --- --- Indoor Motor FLA (ooling).4.7 Horsepower - PM.0-725.0 -,725 Piston Size (ooling) 0.070 0.070 Filter Size (") (4) 4" x 20" x 2" (4) 4" x 20" x 2" Drain Size (NPT) ¾" ¾" -40A efrigerant harge ir # (oz.) 05 05 Evaporator oil Face Area (ft²) 7.0 7.0 ows Deep / Fins per Inch 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) (" x 0") (" x 0") Motor Sheave VL4 x ⅝ VL4 x ⅝ Blower Sheave / Belt AK6 x / AX5 AK6 x / AX5 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,050 Fan Diameter/ # Fan Blades 22/4 22 / 4 Outdoor Nominal FM,800,800 Face Area (ft²) 7. 7. ows Deep/ Fins per Inch / 24 / 24 ompressor Quantity / Type/ Stage / Scroll/Single / Scroll/Single ompressor LA / LA 0.4 / 7.0 5.8 / 8.0 Electrical Data Voltage-Phase-Frequency 208/20--60 460--60 Indoor Blower HP / FLA /.4 /.7 Max. External Static.0".0" Outdoor Fan HP / FLA ¼ /.4 ¼ / 0.7 Min. ircuit Ampacity¹ 7.9 0 Max. Overcurrent Protection (amps)² 25 5 Power Supply onduit Hole.25.25 Low-Voltage onduit Hole ½" ½" Operating eight (lbs) 570 570 Ship eight (lbs) 595 595 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. SS-DS www.daikinac.com 5

Product Specifications Tons (cont.) DS06 090D***A* DS06 090D***A* DS06 090B***A* DS06 0904B***A* DS06 0907B***A* ooling apacity Total BTU/h 6,000 6,000 5,000 5,000 5,000 Sensible BTU/h 26,640 26,640 25,600 25,600 25,600 SEE / EE 4 / 2 4 / 2 4 / 2 4 / 2 4 / 2 Decibels 78 78 78 78 78 AHI eference #s 9967 99674 99524 995220 995226 Heating apacity High Input / Output BTU/h 92 / 75 92 / 74 92 / 74 92 / 74 92 / 74 Low Input / Output BTU/h 69 / 56 69 / 55 69 / 55 69 / 55 69 / 55 Thermal Efficiency (T.E.) ---- 80 80 80 80 Annual Fuel Utilization Efficiency (AFUE) 8 ---- ---- ---- ---- Temperature ise ange ( F) Hi / Low 0-60 / 20-50 40-70 / 0-60 40-70 / 0-60 25-55 25-55 No. of Burners 4 4 4 4 4 Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal FM,250,250,200,200,200 Motor Speed Tap (ooling) LO LO --- --- --- Indoor Motor FLA (ooling) 2.46 2.46.4.7 2. Horsepower - PM ⅓ - 90 ⅓ - 90.0-725.0 -,725.5 -,725 Piston Size (ooling) 0.070 0.070 0.070 0.070 0.070 Filter Size (") (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" -40A efrigerant harge ir # (oz.) 05 05 05 05 05 Evaporator oil Face Area (ft²) 7.0 7.0 7.0 7.0 7.0 ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) ---- ---- (" x 0") (" x 0") (" x 0") Motor Sheave ---- ---- VL4 x ⅝ VL4 x ⅝ VL4 x ⅝ Blower Sheave / Belt ---- ---- AK6 x / AX5 AK6 x / AX5 AK6 x / AX5 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 ¼ -,075 ¼ -,050 ¼ -,050 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22/4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800,800 Face Area (ft²) 7. 7. 7. 7. 7. ows Deep/ Fins per Inch / 24 / 24 / 24 / 24 / 24 ompressor Quantity / Type/ Stage / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single ompressor LA / LA 6.7 / 79.0 0.4 / 7.0 0.4 / 7.0 5.8 / 8.0.8 / 6.5 Electrical Data Voltage-Phase-Frequency 208/20--60 208/20--60 208/20--60 460--60 575--60 Indoor Blower HP / FLA / / 2.46 / / 2.46 /.4 /.7.5 / 2. Max. External Static 0.5" 0.5".0".0".0" Outdoor Fan HP / FLA ¼ /.4 ¼ /.4 ¼ /.4 ¼ / 0.7 ¼ / 0.55 Min. ircuit Ampacity¹ 24.7 / 24.7 6.9 / 6.9 6.9 / 6.9 9.6 7.6 Max. Overcurrent Protection (amps)² 40 / 40 25 / 25 25 / 25 5 5 Power Supply onduit Hole.25".25".25.25.25 Low-Voltage onduit Hole ½" ½" ½" ½" ½" Operating eight (lbs) 575 575 575 575 575 Ship eight (lbs) 600 600 600 600 600 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. 6 www.daikinac.com SS-DS

Product Specifications 4 Tons DS048 070B***A* DS048 0704B***A* ooling apacity Total BTU/h 47,000 47,000 Sensible BTU/h 5,000 5,000 SEE / EE 4 /.8 4 /.8 Decibels 78 78 AHI eference #s 99525 99522 Heating apacity High Input / Output BTU/h 69 / 55 69 / 55 Low Input / Output BTU/h 5 / 4 5 / 4 Thermal Efficiency (T.E.) 80 80 Annual Fuel Utilization Efficiency (AFUE) ---- ---- Temperature ise ange ( F) Hi / Low 20-50 / 0-40 20-50 / 0-40 No. of Burners Evaporator Motor / oil Motor Type Belt Drive Belt Drive Indoor Nominal FM,600,600 Motor Speed Tap (ooling) --- -- Indoor Motor FLA (ooling).4.7 Horsepower - PM.0 /,725.0 /,725 Piston Size (ooling) 0.074 0.074 Filter Size (") (4)4 x 20 x 2 (4)4" x 20" x 2" Drain Size (NPT) ¾" ¾" -40A efrigerant harge ir # (oz.) Evaporator oil Face Area (ft²) 7.8 7.8 ows Deep / Fins per Inch 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) () x 0 () x 0 Motor Sheave VL40 X ⅝ VL40 X ⅝ Blower Sheave / Belt AK66 X / AX52 AK66 X / AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ - 050 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 Outdoor Nominal FM,800,800 Face Area (ft²) 2.5 2.5 ows Deep/ Fins per Inch 2 / 27 2 / 27 ompressor Quantity / Type/ Stage / Scroll/Single / Scroll/Single ompressor LA / LA. / 8. 6. / 4 Electrical Data Voltage-Phase-Frequency 208/20--60 460--60 Indoor Blower HP / FLA.0 /.4.0 /.7 Max. External Static.0".0" Outdoor Fan HP / FLA ¼ /.4 ¼ / 0.7 Min. ircuit Ampacity¹ 2.2 0.0 Max. Overcurrent Protection (amps)² 0 5 Power Supply onduit Hole.25.25 Low-Voltage onduit Hole ½" ½" Operating eight (lbs) 605 605 Ship eight (lbs) 60 60 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. SS-DS www.daikinac.com 7

Product Specifications 4 Tons (cont.) DS048 090D***A* DS048 090D***A* DS048 090B***A* DS048 0904B***A* ooling apacity Total BTU/h 48,000 48,000 47,000 47,000 Sensible BTU/h 5,520 5,520 5,000 5,000 SEE / EE 4 / 2 4 / 2 4 /.8 4 /.8 Decibels 78 78 78 78 AHI eference #s 99672 99675 99525 99522 Heating apacity High Input / Output BTU/h 92 / 75 92 / 74 92 / 74 92 / 74 Low Input / Output BTU/h 69 / 56 69 / 55 69 / 55 69 / 55 Thermal Efficiency (T.E.) ---- 80 80 80 Annual Fuel Utilization Efficiency (AFUE) 8 ---- ---- ---- Temperature ise ange ( F) Hi / Low 25-50/ 5-45 0-60 / 5-45 0-60 / 5-45 0-60 / 5-45 No. of Burners 4 4 4 4 Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal FM,600,600,600,600 Motor Speed Tap (ooling) LO LO --- -- Indoor Motor FLA (ooling) 2.80 2.80.4.7 Horsepower - PM ¾ -,025 ¾ -,025.0 /,725.0 /,725 Piston Size (ooling) 0.076 0.076 0.074 0.074 Filter Size (Qty) (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4)4 x 20 x 2 (4)4" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" -40A efrigerant harge ir # (oz.) 0 0 Evaporator oil Face Area (ft²) 7.8 7.8 7.8 7.8 ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) ---- ---- () x 0 () x 0 Motor Sheave ---- ---- VL40 X ⅝ VL40 X ⅝ Blower Sheave / Belt ---- ---- AK66 X / AX52 AK66 X / AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 ¼ -,075 ¼ - 050 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800 Face Area (ft²) 2.5 2.5 2.5 2.5 ows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 ompressor Quantity / Type/ Stage / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single ompressor LA / LA 9.9 / 09./ 8.. / 8. 6. / 4 Electrical Data Voltage-Phase-Frequency 208/20--60 208/20--60 208/20--60 460--60 Indoor Blower HP / FLA ¾ / 2.8 ¾ / 2.8.0 /.4.0 /.7 Max. External Static 0.5" 0.5".0".0" Outdoor Fan HP / FLA.40.40.40 0.70 Min. ircuit Ampacity¹ 29 / 29 20.6 / 20.6 2.2 / 2.2 0 Max. Overcurrent Protection (amps)² 45 / 45 0 / 0 0 / 0 5 Power Supply onduit Hole.25".25".25.25 Low-Voltage onduit Hole ½" ½" ½" ½" Operating eight (lbs) 60 60 60 60 Ship eight (lbs) 65 65 65 65 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. 8 www.daikinac.com SS-DS

Product Specifications 4 Tons (cont.) DS048 5D***A* DS048 5D***A* DS048 5B***A* DS048 54B***A* DS048 57B***A* ooling apacity Total BTU/h 48,000 48,000 47,000 47,000 47,000 Sensible BTU/h 5,520 5,520 5,000 5,000 5,000 SEE / EE 4 / 2 4 / 2 4 /.8 4 /.8 4 /.8 Decibels 78 78 78 78 78 AHI eference #s 99672 99675 99525 99522 995227 Heating apacity High Input / Output BTU/h 5 / 9 5 / 92 5 / 92 5 / 92 5 / 92 Low Input / Output BTU/h 86 / 70 89 / 69 89 / 69 89 / 69 89 / 69 Thermal Efficiency (T.E.) ---- 80 80 80 80 Annual Fuel Utilization Efficiency (AFUE) 8 ---- ---- ---- ---- Temperature ise ange ( F) Hi / Low 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 40-70 / 25-55 No. of Burners 5 5 5 5 5 Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal FM,600,600,600,600,600 Motor Speed Tap (ooling) LO LO -- -- -- Indoor Motor FLA (ooling) 2.80 2.80.4.7 2. Horsepower - PM ¾ -,025 ¾ -,025.0 /,725.0 /,725.5 /,725 Piston Size (ooling) 0.076 0.076 0.074 0.074 0.074 Filter Size (Qty) (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4)4" x 20" x 2" (4)4" x 20" x 2" (4)4" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" -40A efrigerant harge ir # (oz.) 0 0 Evaporator oil Face Area (ft²) 7.8 7.8 7.8 7.8 7.8 ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) ---- ---- () x 0 () x 0 () x 0 Motor Sheave ---- ---- VL40 X ⅝ VL40 X ⅝ VL40 X ⅝ Blower Sheave / Belt ---- ---- AK66 X / AX52 AK66 X / AX52 AK66 X / AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 ¼ -,075 ¼ - 050 ¼ - 050 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800,800 Face Area (ft²) 2.5 2.5 2.5 2.5 2.5 ows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 2 / 27 ompressor Quantity / Type/ Stage / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single ompressor LA / LA 9.9 / 09./ 8.. / 8. 6. / 4.0 4.4 /.0 Electrical Data Voltage-Phase-Frequency 208/20--60 208/20--60 208/20--60 460--60 575--60 Indoor Blower HP / FLA ¾ / 2.8 ¾ / 2.8.0 /.4.0 /.7.5 / 2. Max. External Static 0.5" 0.5".0".0".0" Outdoor Fan HP / FLA.40.40.40 0.70 0.55 Min. ircuit Ampacity¹ 29 / 29 20.6 / 20.6 2.2 / 2.2 0 8. Max. Overcurrent Protection (amps)² 45 / 45 0 / 0 0 / 0 5 5 Power Supply onduit Hole.25".25".25.25.25 Low-Voltage onduit Hole ½" ½" ½" ½" ½" Operating eight (lbs) 65 65 65 65 65 Ship eight (lbs) 640 640 640 640 640 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. SS-DS www.daikinac.com 9

Product Specifications 5 Tons DS060 090D***A* DS060 090D***A* DS060 090B***A* DS060 0904B***A* ooling apacity Total BTU/h 58,000 58,000 58,000 58,000 Sensible BTU/h 42,40 42,40 42,800 42,800 SEE / EE 4 /.6 4 /.6 4 /.6 4 /.6 Decibels 78 78 78 78 AHI eference #s 9967 99676 99526 995222 Heating apacity High Input / Output BTU/h 92 / 75 92 / 74 92 / 74 92 / 74 Low Input / Output BTU/h 69 / 56 69 / 55 69 / 55 69 / 55 Thermal Efficiency (T.E.) ---- 80 80 80 Annual Fuel Utilization Efficiency (AFUE) 8 ---- ---- ---- Temperature ise ange ( F) Hi / Low 25-55/20-50 20-50/5-45 20-50 / 5-45 20-50 / 5-45 No. of Burners 4 4 4 4 Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Indoor Nominal FM,800,800,800,800 Motor Speed Tap (ooling) T T ---- ---- Indoor Motor FLA (ooling) 6.90 6.90.2.5 Horsepower - PM -,050 -,050-760 - 760 Piston Size (ooling) 0.086 0.086 0.086 0.086 Filter Size (Qty) (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" -40A efrigerant harge ir # (oz.) 00 00 00 00 Evaporator oil Face Area (ft²) 7.8 7.8 7.8 7.8 ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) ---- ---- (" x 0") (" x 0") Motor Sheave ---- ---- VL40 x ⅞ VL40 x ⅞ Blower Sheave / Belt ---- ---- AK6 x / AX52 AK6 x / AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 ¼ -,075 ¼ -,075 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 ompressor Quantity / Type/ Stage / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single ompressor LA / LA 26.4 / 4.0 6.0 / 0.0 6.0 / 0.0 7.8 / 52 Electrical Data Voltage-Phase-Frequency 208/20--60 208/20--60 208/20--60 460--60 Indoor Blower HP / FLA.0 / 6.9.0 / 6.9.0 /.2.0 /.5 Max. External Static 0.9" 0.9".0".0" Outdoor Fan HP / FLA ¼ /.40 ¼ /.40 ¼ /.40 ¼ / 0.7 Min. ircuit Ampacity¹ 4. / 4. 28. / 28. 24.6 / 24.6.9 Max. Overcurrent Protection (amps)² 60 / 60 40 / 40 40 / 40 5 Power Supply onduit Hole.25".25".25.25 Low-Voltage onduit Hole ½" ½" ½" ½" Operating eight (lbs) 60 60 60 60 Ship eight (lbs) 65 65 65 65 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. 0 www.daikinac.com SS-DS

Product Specifications 5 Tons (cont.) DS060 5B***A* DS060 54B***A* ooling apacity Total BTU/h 58,000 58,000 Sensible BTU/h 4,200 4,200 SEE / EE 4 /.6 4 /.6 Decibels 78 78 AHI eference #s 99526 995222 Heating apacity High Input / Output BTU/h 5 / 92 5 / 92 Low Input / Output BTU/h 86 / 69 86 / 69 Thermal Efficiency (T.E.) 80 80 Annual Fuel Utilization Efficiency (AFUE) ---- ---- Temperature ise ange ( F) Hi / Low 5-65 / 25-55 5-65 / 25-55 No. of Burners 5 5 Evaporator Motor / oil Motor Type Belt Drive Belt Drive Indoor Nominal FM,800,800 Motor Speed Tap (ooling) ---- ---- Indoor Motor FLA (ooling).2 -.0.5 Horsepower - PM.0-760.0-760 Piston Size (ooling) 0.086 0.086 Filter Size (") (4) 4" x 20" x 2" (4) 4" x 20" x 2" Drain Size (NPT) ¾" ¾" -40A efrigerant harge ir # (oz.) 00 00 Evaporator oil Face Area (ft²) 7.8 7.8 ows Deep / Fins per Inch 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) (" x 0") (" x 0") Motor Sheave VL40 x ⅞ VL40 x ⅞ Blower Sheave / Belt AK6 X / AX52 AK6 X / AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 Outdoor Nominal FM,800,800 Face Area (ft²) ows Deep/ Fins per Inch 2 / 27 2 / 27 ompressor Quantity / Type/ Stage / Scroll/Single / Scroll/Single ompressor LA / LA 6.0/ 0.0 7.8 / 52.0 Electrical Data Voltage-Phase-Frequency 208/20--60 460--60 Indoor Blower HP / FLA.0 /.2.0 /.5 Max. External Static.0".0" Outdoor Fan HP / FLA ¼ /.40 ¼ / 0.7 Min. ircuit Ampacity¹ 24.6 2 Max. Overcurrent Protection (amps)² 40 5 Power Supply onduit Hole.25".25" Low-Voltage onduit Hole ½" ½" Operating eight (lbs) 69 69 Ship eight (lbs) 644 644 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. SS-DS www.daikinac.com

Product Specifications 5 Tons (cont.) DS060 40D***A* DS060 40D***A* DS060 40B***A* DS060 404B***A* DS060 407B***A* ooling apacity Total BTU/h 58,000 58,000 58,000 58,000 58,000 Sensible BTU/h 42,40 42,40 4,200 4,200 42,500 SEE / EE 4 /.6 4 /.6 4 /.6 4 /.6 4 /.6 Decibels 78 78 78 78 78 AHI eference #s 9967 99676 99526 995222 995228 Heating apacity High Input / Output BTU/h 8 / 2 8 /0 8 /0 8 /0 8 /0 Low Input / Output BTU/h 04 / 84 0 / 8 0 / 8 0 / 8 0 / 8 Thermal Efficiency (T.E.) ---- 80 80 80 80 Annual Fuel Utilization Efficiency (AFUE) 8 ---- ---- ---- ---- Temperature ise ange ( F) Hi / Low 5-65 / 25-55 5-65 / 25-55 5-65 / 25-55 5-65 / 25-55 5-65 / 25-55 No. of Burners 6 6 6 6 6 Evaporator Motor / oil Motor Type Direct Drive Direct Drive Belt Drive Belt Drive Belt Drive Indoor Nominal FM,800,800,800,800,800 Motor Speed Tap (ooling) T T ---- ---- ---- Indoor Motor FLA (ooling) 6.90 6.90.2.5.2 Horsepower - PM.0 -,050.0 -,050.0-760.0-760.0-760 Piston Size (ooling) 0.086 0.086 0.086 0.086 0.086 Filter Size (") (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" (4) 4" x 20" x 2" Drain Size (NPT) ¾" ¾" ¾" ¾" ¾" -40A efrigerant harge ir # (oz.) 00 00 00 00 00 Evaporator oil Face Area (ft²) 7.8 7.8 7.8 7.8 7.8 ows Deep / Fins per Inch 4 / 6 4 / 6 4 / 6 4 / 6 4 / 6 Belt Drive Evap Fan Data # of heels (D x ) ---- ---- (" x 0") (" x 0") (" x 0") Motor Sheave ---- ---- VL40 x ⅞ VL40 x ⅞ VL40 x ⅞ Blower Sheave / Belt ---- ---- AK6 X / AX52 AK6 X / AX52 AK6 X / AX52 ondenser Fan / oil Quantity of ondenser Fan Motors Horsepower - PM ¼ -,075 ¼ -,075 ¼ -,075 ¼ -,075 ¼ -,075 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 22 / 4 22 / 4 22 / 4 Outdoor Nominal FM,800,800,800,800,800 Face Area (ft²) ows Deep/ Fins per Inch 2 / 27 2 / 27 2 / 27 2 / 27 2 / 27 ompressor Quantity / Type/ Stage / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single / Scroll / Single ompressor LA / LA 26.4 / 4.0 6.0 / 0.0 6.0/ 0.0 7.8 / 52.0 5.7 / 8.9 Electrical Data Voltage-Phase-Frequency 208/20--60 208/20--60 208/20--60 460--60 575--60 Indoor Blower HP / FLA.0 / 6.9.0 / 6.9.0 /.2 -.0.0 /.5.0 /.2 Max. External Static 0.9" 0.9".0".0".0" Outdoor Fan HP / FLA ¼ /.40 ¼ /.40 ¼ /.40 ¼ / 0.7 ¼ / 0.55 Min. ircuit Ampacity¹ 4. / 4. 28. / 28. 24.6 / 24.6.9 8.9 Max. Overcurrent Protection (amps)² 60 / 60 40 / 40 40 / 40 5 5 Power Supply onduit Hole.25".25".25".25".25" Low-Voltage onduit Hole ½" ½" ½" ½" ½" Operating eight (lbs) 620 620 620 620 620 Ship eight (lbs) 645 645 645 645 645 ¹ ire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ² May use fuses or HA-type circuit breakers of the same size as noted. Notes Always check the S& plate for electrical data on the unit being installed. 2 www.daikinac.com SS-DS

Expanded ooling Data Tons Outdoor Ambient Temperature 65 75 85 95 05 5 Entering Indoor et Bulb Temperature IDB Airflow 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 70 50 200 050 MBh 6.7 8. 4.7-5.9 7.2 40.8-5.0 6. 9.8-4.2 5.4 8.8-2.5.7 6.9-0..2 4.2 - S/T 0.75 0.6 0.44-0.78 0.65 0.45-0.80 0.67 0.46-0.8 0.69 0.48-0.86 0.72 0.50-0.86 0.72 0.50 - Delta T 9 6 2-9 7-9 7-9 7-9 6 2-8 5 2 - K 2.46 2.5 2.58-2.6 2.69 2.77-2.79 2.85 2.9-2.9 2.99.08 -.04.0.20 -.4.2. - AMPS 7. 7.5 7.7-7.9 8.0 8. - 8.5 8.7 8.9-9.0 9.2 9.5-9.6 9.8 0. - 0. 0. 0.6 - HI P 27 255 270-266 287 0-0 26 44-45 7 92-88 48 44-429 46 487 - LO P 2 9 0-8 25 7-2 0 42-29 7 49-5 4 57-9 48 62 - MBh 5.7 7.0 40.5-4.8 6. 9.6-4.0 5. 8.6 -.2 4.4 7.7 -.5 2.7 5.8-29.2 0..2 - S/T 0.72 0.60 0.42-0.74 0.62 0.4-0.76 0.64 0.44-0.79 0.66 0.46-0.82 0.68 0.47-0.82 0.69 0.48 - Delta T 20 7-20 7-20 7-20 7-20 7-8 6 2 - K 2.44 2.49 2.56-2.6 2.67 2.75-2.77 2.82 2.9-2.90 2.96.05 -.02.08.8 -.2.8.28 - AMPS 7. 7.4 7.7-7.8 8.0 8.2-8.4 8.6 8.9-9.0 9.2 9.4-9.5 9.7 0.0-0.0 0.2 0.6 - HI P 25 25 267-264 284 00-00 2 4-42 68 88-84 4 47-424 457 482 - LO P 0 8 28-7 24 6-2 29 4-27 6 48-4 42 55-8 47 60 - MBh 2.9 4. 7.4-2.2. 6.5 -.4 2.5 5.7-0.6.7 4.8-29. 0.2.0-27.0 27.9 0.6 - S/T 0.69 0.58 0.40-0.72 0.60 0.42-0.74 0.6 0.4-0.76 0.6 0.44-0.79 0.66 0.46-0.80 0.66 0.46 - Delta T 20 7-20 7-20 8-20 8-20 7-9 6 2 - K 2.9 2.4 2.50-2.56 2.6 2.68-2.70 2.76 2.84-2.84 2.89 2.98-2.95.0.0 -.04..20 - AMPS 7. 7. 7.5-7.6 7.8 8.0-8.2 8.4 8.6-8.7 8.9 9.2-9.2 9.4 9.7-9.7 0.0 0. - HI P 228 245 259-256 275 29-29 - 56 76-7 40 42-42 44 468 - LO P 07 4 24-20 - 8 25 7-24 44-0 8 50-4 4 56-75 50 200 050 MBh 7.4 8.5 4.6 44.7 6.5 7.6 40.7 4.7 5.6 6.7 9.7 42.6 4.8 5.8 8.7 4.6.0 4.0 6.8 9.5 0.6.5 4. 6.6 S/T 0.86 0.77 0.58 0.7 0.89 0.79 0.60 0.9 0.9 0.8 0.62 0.40 0.94 0.84 0.64 0.4 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.4 Delta T 22 20 6 22 20 7 22 20 7 2 22 20 7 2 22 20 7 20 9 5 K 2.48 2.5 2.60 2.68 2.65 2.7 2.79 2.87 2.8 2.87 2.96.05 2.95.0.0.20.07..2..7.2.4.44 AMPS 7.4 7.6 7.8 8.0 7.9 8. 8.4 8.6 8.6 8.8 9.0 9. 9. 9. 9.6 9.9 9.6 9.9 0.2 0.5 0.2 0.4 0.7. HI P 240 258 272 284 269 289 06 9 06 29 48 6 48 75 96 4 92 422 445 465 4 466 492 5 LO P 20 9 9 27 8 47 24 2 44 5 0 8 5 6 6 45 58 69 4 50 64 74 MBh 6. 7.4 40.4 4.4 5.4 6.5 9.5 42.4 4.6 5.6 8.5 4.4.7 4.7 7.6 40.4 2..0 5.7 8. 29.7 0.6. 5.5 S/T 0.82 0.7 0.55 0.6 0.85 0.76 0.57 0.7 0.87 0.78 0.59 0.8 0.90 0.80 0.6 0.9 0.9 0.8 0.6 0.40 0.94 0.84 0.6 0.4 Delta T 2 2 7 2 2 2 7 2 2 2 7 2 2 2 7 2 2 2 7 2 2 20 6 K 2.46 2.5 2.58 2.66 2.6 2.69 2.77 2.85 2.79 2.85 2.9.02 2.9 2.99.08.8.04..20.0.4.2..42 AMPS 7. 7.5 7.7 8.0 7.9 8. 8. 8.6 8.5 8.7 8.9 9. 9.0 9.2 9.5 9.9 9.6 9.8 0. 0.4 0. 0. 0.6.0 HI P 27 255 270 28 266 287 0 6 0 26 44 59 45 7 92 409 88 48 44 460 429 46 487 508 LO P 2 9 0 8 8 25 7 46 2 0 42 52 29 7 49 59 5 44 57 67 40 48 62 7 MBh.5 4.5 7. 40.0 2.7.7 6.4 9..9 2.9 5.6 8.2. 2. 4.7 7. 29.6 0.5.0 5.4 27.4 28.2 0.5 2.8 S/T 0.79 0.70 0.5 0.4 0.82 0.7 0.55 0.6 0.84 0.75 0.57 0.6 0.86 0.77 0.58 0.8 0.90 0.80 0.6 0.9 0.90 0.8 0.6 0.9 Delta T 2 2 7 2 2 22 8 2 2 22 8 2 24 22 8 2 2 2 8 2 22 20 6 K 2.4 2.45 2.52 2.60 2.58 2.6 2.70 2.79 2.7 2.78 2.86 2.95 2.86 2.92.0.0 2.97.0..22.07..2. AMPS 7.2 7. 7.5 7.8 7.7 7.9 8. 8.4 8. 8.5 8.7 9.0 8.8 9.0 9. 9.6 9. 9.5 9.8 0.2 9.8 0. 0.4 0.7 HI P 20 248 262 27 258 278 294 06 294 6 4 48 5 60 80 97 76 405 428 446 46 448 47 49 LO P 08 5 26 4 4 22 4 9 26 8 47 25 45 54 9 52 62 5 44 57 67 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-DS www.daikinac.com

Expanded ooling Data Tons (cont.) Outdoor Ambient Temperature 65 75 85 95 05 5 Entering Indoor et Bulb Temperature IDB Airflow 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 80 50 200 050 MBh 8.0 8.9 4.5 44.4 7. 8.0 40.6 4. 6. 7. 9.6 42. 5.4 6. 8.6 4..6 4. 6.7 9.2..8 4.0 6. S/T 0.94 0.88 0.72 0.54.00 0.9 0.74 0.56.00 0.94 0.76 0.57.00 0.97 0.79 0.59.00.00 0.82 0.6.00.00 0.82 0.62 Delta T 24 2 20 6 25 24 2 6 25 24 2 6 24 24 2 7 2 2 20 6 2 22 9 5 K 2.50 2.55 2.62 2.70 2.67 2.7 2.8 2.90 2.8 2.89 2.98.07 2.97.0..2.09.5.25.6.9.26.6.47 AMPS 7.5 7.6 7.9 8. 8.0 8.2 8.4 8.7 8.6 8.8 9. 9.4 9.2 9.4 9.7 0.0 9.7 0.0 0. 0.6 0. 0.5 0.8.2 HI P 242 26 275 287 272 292 09 22 09 5 66 52 79 400 47 96 426 450 469 47 47 497 59 LO P 4 2 2 4 20 28 40 49 25 45 55 40 5 62 8 46 60 70 42 5 65 76 MBh 6.9 7.7 40. 4. 6. 6.9 9.4 42. 5.2 6.0 8.4 4. 4. 5. 7.5 40. 2.6. 5.6 8. 0.2 0.9.0 5. S/T 0.90 0.84 0.68 0.5 0.9 0.87 0.7 0.5 0.95 0.89 0.7 0.54 0.98 0.92 0.75 0.56.00 0.96 0.78 0.58.00 0.96 0.78 0.59 Delta T 25 24 2 7 26 25 2 7 26 25 2 7 26 25 22 7 25 24 2 7 2 2 20 6 K 2.48 2.5 2.60 2.68 2.65 2.7 2.79 2.87 2.8 2.87 2.96.05 2.95.0.0.20.07..2..7.2.4.44 AMPS 7.4 7.6 7.8 8.0 7.9 8. 8.4 8.6 8.6 8.8 9.0 9. 9. 9. 9.6 9.9 9.6 9.9 0.2 0.5 0.2 0.4 0.7. HI P 240 258 272 284 269 290 06 9 06 29 48 6 48 75 96 4 92 422 446 465 4 466 492 5 LO P 20 9 9 27 8 47 24 2 44 5 0 8 5 6 6 45 58 69 4 50 64 74 MBh 4. 4.8 7.2 9.8. 4.0 6. 8.8 2.5.2 5.5 7.9.7 2.4 4.6 7.0 0. 0.8 2.9 5. 27.9 28.5 0.5 2.6 S/T 0.86 0.8 0.66 0.49 0.90 0.84 0.68 0.5 0.92 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.56 0.99 0.9 0.76 0.57 Delta T 26 25 2 7 26 25 22 7 26 25 22 7 26 25 22 8 26 25 22 7 24 2 20 6 K 2.42 2.47 2.54 2.62 2.59 2.65 2.7 2.8 2.75 2.80 2.89 2.98 2.88 2.94.0.2 2.99.06.5.25.09.6.26.6 AMPS 7.2 7.4 7.6 7.9 7.7 7.9 8.2 8.4 8.4 8.5 8.8 9. 8.9 9. 9.4 9.7 9.4 9.6 9.9 0. 9.9 0. 0.5 0.8 HI P 2 250 264 276 26 28 297 09 297 9 7 52 8 64 84 40 80 409 42 45 420 452 477 498 LO P 09 6 27 5 6 2 4 4 20 28 9 49 26 4 46 56 2 4 54 6 7 45 59 69 85 50 200 050 MBh 8.7 9.4 4. 44. 7.8 8.5 40. 4.0 6.9 7.6 9.4 42.0 6.0 6.7 8.4 4.0 4.2 4.9 6.5 8.9.7 2..8 6. S/T 0.98 0.95 0.86 0.70.00 0.98 0.89 0.72.00.00 0.9 0.74.00.00 0.94 0.76.00.00 0.98 0.79.00.00 0.98 0.80 Delta T 26 26 24 2 26 26 24 2 25 26 24 2 25 25 25 2 2 24 24 2 22 22 2 20 K 2.5 2.56 2.64 2.72 2.69 2.75 2.8 2.92 2.85 2.9.00.0 2.99.06.5.25..8.28.8.22.29.9.50 AMPS 7.5 7.7 7.9 8.2 8. 8. 8.5 8.8 8.7 8.9 9.2 9.5 9. 9.5 9.8 0. 9.8 0.0 0.4 0.7 0.4 0.6 0.9. HI P 245 26 278 290 274 295 2 25 2 6 55 70 55 8 404 42 400 40 454 474 442 476 502 524 LO P 5 22 4 42 2 29 4 50 26 4 47 56 4 54 64 9 48 6 72 44 5 67 78 MBh 7.6 8. 40. 42.8 6.7 7.4 9.2 4.8 5.8 6.5 8.2 40.8 4.9 5.6 7. 9.8.2.8 5.4 7.8 0.8. 2.8 5.0 S/T 0.94 0.9 0.82 0.66 0.97 0.94 0.85 0.69.00 0.96 0.87 0.7.00 0.99 0.90 0.7.00.00 0.9 0.76.00.00 0.94 0.76 Delta T 27 27 25 22 27 27 25 22 27 27 25 22 27 27 26 22 25 26 25 22 24 24 24 20 K 2.50 2.55 2.62 2.70 2.67 2.7 2.8 2.90 2.8 2.89 2.98.07 2.97.0..2.09.5.25.6.9.26.6.47 AMPS 7.5 7.6 7.9 8. 8.0 8.2 8.4 8.7 8.6 8.8 9. 9.4 9.2 9.4 9.7 0.0 9.7 0.0 0. 0.6 0. 0.5 0.8.2 HI P 242 26 275 287 272 292 09 22 09 5 66 52 79 400 47 96 426 450 469 47 47 497 59 LO P 4 2 2 4 20 28 40 49 25 45 55 40 5 62 8 46 60 70 42 5 65 76 MBh 4.7 5. 7.0 9.5.9 4.5 6.2 8.6..7 5. 7.7 2. 2.9 4.4 6.7 0.6.2 2.7 4.9 28.4 28.9 0. 2. S/T 0.9 0.87 0.79 0.64 0.94 0.9 0.82 0.66 0.96 0.9 0.84 0.68 0.99 0.96 0.86 0.70.00 0.99 0.90 0.7.00.00 0.9 0.7 Delta T 27 27 26 22 28 27 26 22 28 27 26 22 28 28 26 2 27 27 26 22 25 25 24 2 K 2.44 2.49 2.56 2.64 2.6 2.67 2.75 2.8 2.77 2.82 2.9.00 2.90 2.96.05.5.02.08.8.28.2.8.28.9 AMPS 7. 7.4 7.7 7.9 7.8 8.0 8.2 8.5 8.4 8.6 8.9 9.2 9.0 9.2 9.4 9.8 9.5 9.7 0.0 0. 0.0 0.2 0.6 0.9 HI P 25 25 267 278 264 284 00 2 00 2 4 55 4 67 88 405 84 4 46 455 424 457 482 50 LO P 0 7 28 7 7 24 6 44 2 29 4 50 27 6 48 58 42 55 65 8 47 60 7 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 4 www.daikinac.com SS-DS

Expanded ooling Data 4 Tons Outdoor Ambient Temperature 65 75 85 95 05 5 Entering Indoor et Bulb Temperature IDB Airflow 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 70 800 600 400 MBh 46.0 47.7 52. - 45.0 46.6 5. - 4.9 45.5 49.9-42.8 44.4 48.6-40.7 42.2 46.2-7.7 9. 42.8 - S/T 0.77 0.64 0.45-0.80 0.67 0.46-0.82 0.68 0.47-0.84 0.70 0.49-0.88 0.7 0.5-0.88 0.74 0.5 - Delta T 8 6 2-8 6 2-8 6 2-8 6 2-8 6 2-7 5 - K.0.7.26 -..40.50 -.5.60.72 -.7.78.90 -.86.94 4.06 -.99 4.07 4.20 - AMPS 8. 8. 8.6-8.7 8.9 9.2-9.4 9.7 0.0-0. 0. 0.6-0.7 0.9.2 -..5.9 - HI P 240 259 27-270 290 06-07 0 48-49 76 97-9 42 447-44 467 49 - LO P 2 9 0-8 26 8-2 4-29 8 50-5 44 57-40 49 6 - MBh 44.7 46. 50.8-4.7 45. 49.6-42.6 44.2 48.4-4.6 4. 47.2-9.5 40.9 44.9-6.6 7.9 4.6 - S/T 0.7 0.6 0.42-0.76 0.64 0.44-0.78 0.65 0.45-0.80 0.67 0.47-0.84 0.70 0.48-0.84 0.70 0.49 - Delta T 9 6 2-9 7-9 7-9 7-9 6 2-8 5 2 - K.08.4.24 -..7.48 -.50.58.69 -.68.75.87 -.8.9 4.0 -.95 4.04 4.7 - AMPS 8. 8. 8.5-8.7 8.9 9. - 9.4 9.6 9.9-0.0 0.2 0.5-0.6 0.8.2 -.2.4.8 - HI P 28 256 270-267 287 0-04 27 45-46 72 9-89 49 442-40 46 488 - LO P 8 29-7 25 6-22 0 42-28 6 49-4 4 56-9 48 6 - MBh 4. 42.8 46.9-40. 4.8 45.8-9. 40.8 44.7-8.4 9.8 4.6-6.5 7.8 4.4 -.8 5.0 8.4 - S/T 0.7 0.59 0.4-0.7 0.6 0.42-0.75 0.6 0.44-0.78 0.65 0.45-0.8 0.67 0.47-0.8 0.68 0.47 - Delta T 9 7-9 7-9 7-20 7-9 7-8 6 2 - K.0.07.6 -.2.0.9 -.42.49.60 -.59.67.78 -.7.8.9 -.86.94 4.07 - AMPS 7.9 8.0 8. - 8.5 8.6 8.9-9. 9. 9.6-9.7 9.9 0.2-0. 0.5 0.9-0.9..5 - HI P 2 248 262-259 279 294-295 7 5-5 6 8-77 406 429-47 449 474 - LO P 08 5 25-4 2 2-8 26 7-24 2 44-0 8 5-5 4 56-75 800 600 400 MBh 46.8 48.2 52.2 56.0 45.7 47. 5.0 54.7 44.6 46.0 49.8 5.4 4.6 44.8 48.5 52. 4.4 42.6 46. 49.5 8. 9.5 42.7 45.8 S/T 0.87 0.78 0.59 0.8 0.9 0.8 0.6 0.9 0.9 0.8 0.6 0.40 0.96 0.86 0.65 0.42.00 0.89 0.67 0.4.00 0.90 0.68 0.44 Delta T 2 9 6 2 9 6 2 20 6 2 20 6 2 9 6 20 8 5 0 K..9.29.9.6.4.5.64.56.6.75.86.74.82.94 4.06.89.97 4.0 4.2 4.02 4.0 4.24 4.7 AMPS 8.2 8.4 8.6 8.9 8.8 9.0 9. 9.6 9.5 9.7 0.0 0.4 0. 0.4 0.7. 0.8.0.4.8.4.6 2.0 2.4 HI P 24 26 276 288 272 29 0 2 0 52 67 5 80 40 48 97 427 45 470 49 472 498 520 LO P 20 2 40 20 27 9 48 24 2 44 54 9 52 62 7 46 59 69 42 5 64 75 MBh 45.5 46.8 50.7 54.4 44.4 45.7 49.5 5. 4. 44.6 48. 5.8 42. 4.5 47. 50.6 40.2 4.4 44.8 48. 7.2 8. 4.5 44.5 S/T 0.8 0.75 0.56 0.6 0.86 0.77 0.59 0.8 0.89 0.79 0.60 0.9 0.9 0.82 0.62 0.40 0.95 0.85 0.64 0.4 0.96 0.86 0.65 0.42 Delta T 22 20 6 22 20 7 22 20 7 2 22 20 7 2 22 20 7 20 9 5 K..7.26.6..40.50.6.5.60.72.8.7.79.90 4.0.86.94 4.06 4.20.99 4.07 4.20 4.4 AMPS 8. 8. 8.6 8.9 8.7 8.9 9.2 9.5 9.4 9.7 0.0 0. 0. 0. 0.6.0 0.7 0.9..7..5.9 2. HI P 240 259 27 285 270 290 06 20 07 0 49 64 49 76 97 44 9 42 447 466 44 467 49 55 LO P 2 9 0 9 8 26 8 47 2 4 52 29 8 50 60 6 44 57 68 40 49 6 7 MBh 42.0 4.2 46.8 50.2 4.0 42.2 45.7 49.0 40.0 4.2 44.6 47.9 9.0 40.2 4.5 46.7 7. 8.2 4. 44.4 4. 5.4 8. 4. S/T 0.80 0.72 0.54 0.5 0.8 0.75 0.56 0.6 0.85 0.76 0.58 0.7 0.88 0.79 0.60 0.8 0.92 0.82 0.62 0.40 0.92 0.8 0.6 0.40 Delta T 22 20 7 2 22 2 7 2 22 2 7 2 2 2 7 2 22 2 7 2 2 9 6 K.04.0.9.28.25.2.42.5.45.52.6.74.62.69.8.9.76.84.97 4.09.89.97 4.0 4.2 AMPS 7.9 8. 8.4 8.6 8.5 8.7 9.0 9. 9.2 9.4 9.7 0.0 9.8 0.0 0. 0.7 0.4 0.6.0..0.2.6 2.0 HI P 2 25 265 276 262 282 297 0 298 20 8 5 9 65 85 402 8 40 4 452 42 45 479 499 LO P 09 6 26 5 5 22 42 9 27 9 48 25 46 55 40 5 6 6 45 58 68 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-DS www.daikinac.com 5

Expanded ooling Data 4 Tons (cont.) Outdoor Ambient Temperature 65 75 85 95 05 5 Entering Indoor et Bulb Temperature IDB Airflow 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 80 800 600 400 MBh 47.7 48.7 52.0 55.6 46.5 47.6 50.8 54. 45.4 46.4 49.6 5.0 44. 45. 48.4 5.7 42. 4.0 46.0 49. 9.0 9.9 42.6 45.5 S/T 0.96 0.90 0.7 0.55.00 0.9 0.76 0.57.00 0.96 0.78 0.58.00.00 0.80 0.60.00.00 0.8 0.62.00.00 0.84 0.6 Delta T 2 22 9 6 24 2 20 6 2 2 20 6 2 2 20 6 22 22 20 6 20 20 8 5 K.5.22..4.8.45.56.67.59.66.78.90.77.85.97 4.0.92 4.00 4. 4.26 4.05 4.4 4.27 4.4 AMPS 8. 8.5 8.7 9.0 8.9 9. 9.4 9.7 9.6 9.8 0. 0.5 0.2 0.5 0.8.2 0.8..5.9.5.7 2. 2.5 HI P 245 264 279 29 275 296 26 7 56 7 56 84 405 422 40 4 456 475 44 477 50 525 LO P 4 22 4 2 29 40 49 26 4 46 55 2 40 5 6 8 47 6 7 4 52 66 77 MBh 46. 47. 50.5 54.0 45.2 46.2 49. 52.7 44. 45. 48.2 5.5 4.0 44.0 47.0 50.2 40.9 4.8 44.6 47.7 7.9 8.7 4. 44.2 S/T 0.9 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.9 0.74 0.55.00 0.94 0.77 0.57.00 0.98 0.80 0.59.00 0.98 0.80 0.60 Delta T 24 2 20 6 25 24 2 6 25 24 2 6 25 24 2 7 2 2 20 6 22 22 9 5 K..9.29.9.6.4.5.64.56.6.75.87.74.82.94 4.06.89.97 4.0 4.2 4.02 4.0 4.24 4.8 AMPS 8.2 8.4 8.6 8.9 8.8 9.0 9. 9.6 9.5 9.7 0.0 0.4 0. 0.4 0.7. 0.8.0.4.8.4.6 2.0 2.4 HI P 24 26 276 288 272 29 0 2 0 52 67 5 80 40 48 97 427 45 47 49 472 498 520 LO P 20 2 40 20 27 9 48 24 2 44 54 9 52 62 7 46 59 69 42 5 64 75 MBh 42.7 4.6 46.6 49.8 4.7 42.6 45.5 48.7 40.7 4.6 44.5 47.5 9.7 40.6 4.4 46.4 7.7 8.6 4.2 44.0 5.0 5.7 8.2 40.8 S/T 0.88 0.8 0.67 0.50 0.9 0.86 0.70 0.52 0.94 0.88 0.72 0.5 0.97 0.9 0.74 0.55.00 0.94 0.77 0.57.0 0.95 0.77 0.58 Delta T 25 24 2 6 25 24 2 7 25 24 2 7 25 24 2 7 25 24 2 7 2 22 9 5 K.06.2.2..28.5.45.56.48.55.66.77.65.72.84.96.79.88 4.00 4..92 4.00 4. 4.27 AMPS 8.0 8.2 8.4 8.7 8.6 8.8 9. 9.4 9. 9.5 9.8 0. 9.9 0. 0.4 0.8 0.5 0.7..4...7 2. HI P 25 25 268 279 264 284 00 0 2 42 56 42 68 89 406 85 44 48 456 425 458 48 504 LO P 0 7 28 6 6 2 5 44 2 28 40 49 27 5 47 57 4 54 64 7 46 60 70 85 800 600 400 MBh 48.5 49.4 5.8 55.2 47.4 48. 50.6 5.9 46.2 47. 49.4 52.7 45. 46.0 48.2 5.4 42.8 4.7 45.7 48.8 9.7 40.5 42.4 45.2 S/T.00 0.97 0.88 0.7.00.00 0.9 0.74.00.00 0.9 0.76.00.00 0.96 0.78.00.00.00 0.8.00.00.00 0.82 Delta T 25 24 2 20 24 25 2 20 24 24 2 20 2 2 24 20 22 22 2 20 20 2 22 9 K.8.24.4.44.4.48.59.70.6.69.8.9.80.88 4.00 4..95 4.04 4.6 4.0 4.08 4.7 4. 4.45 AMPS 8. 8.5 8.8 9. 9.0 9.2 9.5 9.8 9.7 9.9 0.2 0.6 0. 0.6 0.9. 0.9.2.6 2.0.6.8 2.2 2.6 HI P 248 267 28 294 278 299 6 29 6 40 59 75 60 87 409 427 405 46 460 480 447 482 508 50 LO P 6 2 4 4 22 0 42 5 27 5 47 57 42 55 65 40 49 62 7 44 54 68 79 MBh 47. 48.0 50. 5.6 46.0 46.9 49. 52.4 44.9 45.8 47.9 5. 4.8 44.6 46.8 49.9 4.6 42.4 44.4 47.4 8.5 9. 4. 4.9 S/T 0.96 0.9 0.84 0.68 0.99 0.96 0.87 0.70.00 0.98 0.89 0.72.00.00 0.92 0.74.00.00 0.95 0.77.00.00 0.96 0.78 Delta T 26 26 24 2 26 26 24 2 26 26 24 2 25 26 25 2 24 24 24 2 22 2 2 20 K.5.22..4.8.45.56.67.59.66.78.90.77.85.97 4.0.92 4.00 4. 4.26 4.05 4.4 4.27 4.4 AMPS 8. 8.5 8.7 9.0 8.9 9. 9.4 9.7 9.6 9.8 0. 0.5 0.2 0.5 0.8.2 0.8..5.9.5.7 2. 2.5 HI P 245 264 279 29 275 296 26 7 56 7 56 84 405 422 40 4 456 475 44 477 50 525 LO P 4 22 4 2 29 40 49 26 4 46 55 2 40 5 6 8 47 6 7 4 52 66 77 MBh 4.5 44. 46.4 49.5 42.4 4. 45. 48. 4.4 42.2 44.2 47.2 40.4 4.2 4.2 46.0 8.4 9. 4.0 4.7 5.6 6. 8.0 40.5 S/T 0.92 0.89 0.8 0.65 0.96 0.92 0.8 0.68 0.98 0.95 0.86 0.69.00 0.98 0.88 0.72.00.00 0.92 0.74.00.00 0.92 0.75 Delta T 26 26 25 2 27 26 25 2 27 26 25 22 27 26 25 22 25 26 25 2 2 24 2 20 K.08.4.24..0.7.48.58.50.58.69.80.68.75.87 4.00.82.9 4.0 4.6.95 4.04 4.7 4.0 AMPS 8. 8.2 8.5 8.8 8.7 8.9 9. 9.5 9.4 9.6 9.9 0.2 0.0 0.2 0.5 0.9 0.6 0.8..5.2.4.8 2.2 HI P 28 256 270 282 267 287 0 6 04 27 45 60 46 72 9 40 89 49 442 46 40 462 488 509 LO P 8 29 7 7 25 6 45 22 0 4 5 28 6 49 58 4 4 56 66 9 48 6 72 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 6 www.daikinac.com SS-DS

Expanded ooling Data 5 Tons Outdoor Ambient Temperature 65 75 85 95 05 5 Entering Indoor et Bulb Temperature IDB Airflow 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 70 2050 800 550 MBh 57.6 59.7 65.4-56. 58. 6.9-54.9 56.9 62.4-5.6 55.6 60.9-50.9 52.8 57.8-47.2 48.9 5.6 - S/T 0.74 0.62 0.4-0.77 0.64 0.44-0.78 0.66 0.45-0.8 0.68 0.47-0.84 0.70 0.49-0.85 0.7 0.49 - Delta T 9 7-9 7-9 7-9 7-9 7-8 6 2 - K.95 4.04 4.7-4.26 4.5 4.49-4.5 4.6 4.78-4.77 4.87 5.04-4.97 5.08 5.25-5.5 5.26 5.44 - AMPS 0.2 0.4 0.7 -.0.2.6 -.9 2.2 2.6-2.7.0.5 -.5.9 4. - 4. 4.7 5.2 - HI P 257 277 292-289 28-28 5 7-74 40 425-42 45 478-465 500 528 - LO P 07 4 24-20 - 7 25 6-2 4-29 7 50-4 42 55 - MBh 55.9 58.0 6.5-54.6 56.6 62.0-5. 55. 60.6-52.0 5.9 59. - 49.4 5.2 56. - 45.8 47.5 52.0 - S/T 0.70 0.59 0.4-0.7 0.6 0.42-0.75 0.62 0.4-0.77 0.65 0.45-0.80 0.67 0.46-0.8 0.68 0.47 - Delta T 20 7-20 8-20 8-2 8-20 8-9 6 2 - K.92 4.00 4. - 4.22 4.2 4.46-4.49 4.59 4.74-4.7 4.8 4.99-4.9 5.04 5.2-5.0 5.22 5.9 - AMPS 0. 0. 0.6-0.9..5 -.8 2. 2.5-2.6 2.9.4 -.4.7 4.2-4.2 4.6 5. - HI P 255 274 290-286 08 25-25 50 70-70 99 42-47 448 474-460 495 52 - LO P 06 2-2 9 0-6 24 5-22 0 42-28 6 49-2 4 54 - MBh 5.6 5.5 58.6-50.4 52. 57. - 49.2 5.0 55.9-48.0 49.8 54.5-45.6 47. 5.8-42. 4.8 48.0 - S/T 0.68 0.57 0.9-0.70 0.59 0.4-0.72 0.60 0.42-0.74 0.62 0.4-0.77 0.65 0.45-0.78 0.65 0.45 - Delta T 2 8 4-2 8 4-2 8 4-2 8 4-2 8 4-20 7 - K.8.9 4.0-4.2 4.2 4.5-4.8 4.48 4.62-4.6 4.7 4.87-4.8 4.9 5.08-4.97 5.09 5.26 - AMPS 9.8 0.0 0.4-0.6 0.8.2 -.5.8 2.2-2. 2.6.0 -..4.8 -.8 4.2 4.6 - HI P 247 266 28-277 298 5-5 9 58-59 87 408-404 45 459-447 48 507 - LO P 0 09 9-08 5 26-20 - 8 26 7-24 2 44-28 6 49-75 2050 800 550 MBh 58.6 60. 65. 70. 57.2 58.9 6.8 68.5 55.9 57.5 62. 66.8 54.5 56. 60.7 65.2 5.8 5. 57.7 6.9 48.0 49.4 5.5 57.4 S/T 0.84 0.75 0.57 0.7 0.87 0.78 0.59 0.8 0.89 0.80 0.60 0.9 0.92 0.82 0.62 0.40 0.96 0.85 0.65 0.42 0.96 0.86 0.65 0.42 Delta T 22 20 7 22 2 7 2 22 2 7 2 2 2 7 2 22 20 7 2 2 9 6 K.98 4.07 4.20 4.4 4.29 4.9 4.5 4.68 4.57 4.67 4.82 4.98 4.8 4.92 5.08 5.25 5.0 5. 5.0 5.48 5.9 5. 5.49 5.68 AMPS 0. 0.5 0.8.2...7 2. 2.0 2. 2.7.2 2.8.2.6 4..7 4.0 4.5 5.0 4.5 4.8 5. 5.9 HI P 260 280 295 08 292 4 2 46 2 57 77 9 78 407 429 448 425 458 48 504 470 506 54 557 LO P 08 5 25 4 4 2 2 4 9 26 8 47 24 2 45 54 0 9 52 6 5 44 57 67 MBh 56.9 58.6 6.4 68.0 55.6 57.2 6.9 66.5 54.2 55.8 60.5 64.9 52.9 54.5 59.0 6. 50. 5.8 56.0 60. 46.6 47.9 5.9 55.7 S/T 0.80 0.72 0.54 0.5 0.8 0.74 0.56 0.6 0.85 0.76 0.58 0.7 0.88 0.79 0.59 0.8 0.9 0.82 0.62 0.40 0.92 0.82 0.62 0.40 Delta T 2 2 8 2 24 22 8 2 24 22 8 2 24 22 8 2 2 22 8 2 22 20 6 K.95 4.04 4.7 4.0 4.26 4.5 4.49 4.64 4.5 4.6 4.78 4.94 4.77 4.88 5.04 5.2 4.97 5.08 5.25 5.4 5.5 5.26 5.44 5.6 AMPS 0.2 0.4 0.7..0.2.6 2.0.9 2.2 2.6. 2.7.0.5 4.0.5.9 4. 4.9 4. 4.7 5.2 5.8 HI P 257 277 29 05 289 28 42 29 54 7 89 74 40 425 44 42 45 478 499 465 50 529 55 LO P 07 4 24 2 20 40 7 25 6 45 2 4 52 29 7 50 60 4 42 55 65 MBh 52.5 54. 58.5 62.8 5. 52.8 57.2 6. 50. 5.5 55.8 59.9 48.8 50. 54.4 58.4 46.4 47.8 5.7 55.5 4.0 44. 47.9 5.4 S/T 0.77 0.69 0.52 0.4 0.80 0.72 0.54 0.5 0.82 0.7 0.56 0.6 0.85 0.76 0.57 0.7 0.88 0.79 0.59 0.8 0.89 0.79 0.60 0.9 Delta T 24 22 8 24 22 8 24 22 8 25 2 9 24 22 8 2 2 7 2 K.86.94 4.06 4.20 4.6 4.25 4.8 4.5 4.42 4.5 4.66 4.82 4.65 4.75 4.9 5.07 4.85 4.96 5.2 5.29 5.02 5. 5.0 5.48 AMPS 9.9 0. 0.5 0.8 0.7 0.9..7.6.9 2. 2.7 2.4 2.7..6.2.5.9 4.5 4.0 4. 4.8 5. HI P 250 269 284 296 280 02 8 2 9 4 62 78 6 9 42 40 408 49 464 484 45 486 5 55 LO P 04 0 20 28 0 7 27 5 4 2 2 4 20 27 9 48 25 46 55 0 8 5 60 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AA (TVA) ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) SS-DS www.daikinac.com 7

Expanded ooling Data 5 Tons (cont.) Outdoor Ambient Temperature 65 75 85 95 05 5 Entering Indoor et Bulb Temperature IDB Airflow 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 59 6 67 7 80 2050 800 550 MBh 59.6 60.9 65. 69.6 58. 59.5 6.6 68.0 56.9 58. 62. 66.4 55.5 56.7 60.6 64.7 52.7 5.9 57.5 6.5 48.8 49.9 5. 57.0 S/T 0.92 0.86 0.70 0.5 0.95 0.89 0.7 0.54.00 0.92 0.75 0.56.00 0.95 0.77 0.58.00.00 0.80 0.60.00.00 0.8 0.60 Delta T 25 24 2 6 25 24 2 7 26 24 2 7 25 24 2 7 24 24 2 6 22 22 9 5 K 4.02 4.0 4.2 4.7 4. 4.42 4.57 4.72 4.6 4.7 4.86 5.0 4.85 4.96 5.2 5.0 5.06 5.7 5.4 5.5 5.24 5.5 5.5 5.72 AMPS 0. 0.6 0.9..2.4.8 2. 2. 2.4 2.8..0..7 4.2.8 4. 4.6 5.2 4.6 5.0 5.5 6. HI P 26 28 298 295 7 5 49 5 6 8 97 82 4 44 452 429 462 488 509 475 5 59 562 LO P 09 6 27 5 5 2 4 42 20 27 9 48 26 4 46 56 2 40 5 6 6 45 58 69 MBh 57.9 59.2 6.2 67.6 56.6 57.8 6.7 66.0 55.2 56.4 60. 64.4 5.9 55.0 58.8 62.9 5.2 52. 55.9 59.7 47.4 48.4 5.7 55. S/T 0.88 0.82 0.67 0.50 0.9 0.85 0.69 0.52 0.9 0.87 0.7 0.5 0.96 0.90 0.74 0.55.00 0.94 0.76 0.57.00 0.95 0.77 0.57 Delta T 26 25 22 7 26 25 22 7 26 25 22 8 26 25 22 8 26 25 22 7 24 2 20 6 K.98 4.07 4.20 4.4 4.29 4.9 4.5 4.68 4.57 4.67 4.82 4.98 4.8 4.92 5.08 5.25 5.0 5. 5.0 5.48 5.9 5. 5.49 5.68 AMPS 0. 0.5 0.8.2...7 2. 2.0 2. 2.7.2 2.9.2.6 4..7 4.0 4.5 5.0 4.5 4.8 5. 5.9 HI P 260 280 295 08 292 4 2 46 2 57 77 9 78 407 40 448 425 458 48 504 470 506 54 557 LO P 08 5 25 4 4 2 2 4 9 26 8 47 25 2 45 54 0 9 52 6 5 44 57 67 MBh 5.4 54.6 58. 62.4 52.2 5. 57.0 60.9 5.0 52. 55.6 59.5 49.7 50.8 54. 58.0 47.2 48. 5.6 55. 4.7 44.7 47.8 5. S/T 0.85 0.79 0.65 0.48 0.88 0.82 0.67 0.50 0.90 0.84 0.69 0.5 0.9 0.87 0.7 0.5 0.96 0.90 0.74 0.55 0.97 0.9 0.74 0.55 Delta T 27 26 22 8 27 26 2 8 27 26 2 8 27 26 2 8 27 26 22 8 25 24 2 7 K.89.97 4.0 4.2 4.9 4.28 4.42 4.56 4.45 4.55 4.70 4.86 4.69 4.79 4.95 5.2 4.89 5.00 5.6 5.4 5.06 5.7 5.5 5.5 AMPS 0.0 0.2 0.5 0.9 0.8.0.4.8.7 2.0 2.4 2.8 2.5 2.8.2.7..6 4. 4.6 4. 4.4 4.9 5.5 HI P 252 27 287 299 28 05 22 5 22 46 66 82 67 95 47 45 42 444 469 489 456 490 58 540 LO P 05 22 0 8 28 7 5 22 4 42 2 28 40 49 27 5 47 57 9 52 62 85 2050 800 550 MBh 60.7 6.9 64.8 69. 59. 60.4 6. 67.5 57.9 59.0 6.8 65.9 56.4 57.5 60. 64. 5.6 54.7 57.2 6. 49.7 50.6 5.0 56.6 S/T 0.96 0.9 0.84 0.68.00 0.96 0.87 0.7.00 0.99 0.89 0.72.00.00 0.92 0.75.00.00 0.96 0.78.00.00 0.96 0.78 Delta T 26 26 24 2 27 26 25 2 26 26 25 2 25 26 25 22 24 25 25 2 22 2 2 20 K 4.05 4.4 4.27 4.4 4.7 4.46 4.6 4.76 4.64 4.75 4.90 5.07 4.89 5.00 5.7 5.4 5.0 5.2 5.9 5.57 5.28 5.40 5.58 5.77 AMPS 0.4 0.7.0.4..5.9 2.4 2.2 2.5.0.4..4.9 4.4.9 4. 4.7 5. 4.8 5. 5.6 6.2 HI P 265 285 0 4 298 20 8 5 9 64 85 40 86 45 48 457 44 467 49 54 479 56 545 568 LO P 0 7 28 6 6 24 5 44 2 29 40 50 27 5 48 57 42 55 65 8 46 60 70 MBh 58.9 60. 62.9 67. 57.5 58.7 6.4 65.5 56.2 57. 60.0 64.0 54.8 55.9 58.5 62.4 52. 5. 55.6 59. 48.2 49.2 5.5 54.9 S/T 0.92 0.89 0.80 0.65 0.95 0.92 0.8 0.67 0.98 0.94 0.85 0.69.00 0.97 0.88 0.7.00.00 0.9 0.74.00.00 0.92 0.75 Delta T 28 27 26 22 28 28 26 2 28 28 26 2 28 28 26 2 27 27 26 22 25 25 24 2 K 4.02 4.0 4.2 4.7 4. 4.42 4.57 4.72 4.6 4.7 4.86 5.0 4.85 4.96 5.2 5.0 5.06 5.7 5.4 5.5 5.24 5.5 5.5 5.72 AMPS 0. 0.6 0.9..2.4.8 2. 2. 2.4 2.8..0..7 4.2.8 4. 4.6 5.2 4.6 5.0 5.5 6. HI P 26 28 298 295 7 5 49 5 6 8 97 82 4 44 452 429 462 488 509 475 5 59 562 LO P 09 6 27 5 5 2 4 42 20 27 9 48 26 4 46 56 2 40 5 6 6 45 58 69 MBh 54.4 55.4 58. 6.9 5. 54. 56.7 60.5 5.8 52.8 55.4 59. 50.6 5.6 54.0 57.6 48. 49.0 5. 54.7 44.5 45.4 47.5 50.7 S/T 0.89 0.86 0.77 0.6 0.92 0.89 0.80 0.65 0.94 0.9 0.82 0.67 0.97 0.94 0.85 0.69.00 0.97 0.88 0.7.00 0.98 0.89 0.72 Delta T 29 28 27 2 29 28 27 2 29 29 27 2 29 29 27 2 29 28 27 2 26 26 25 22 K.92 4.00 4. 4.26 4.22 4.2 4.45 4.60 4.49 4.59 4.74 4.90 4.7 4.8 4.99 5.6 4.9 5.04 5.2 5.8 5.0 5.22 5.9 5.58 AMPS 0. 0. 0.6.0 0.9..5.9.8 2. 2.5.0 2.6 2.9..8.4.7 4.2 4.7 4.2 4.6 5.0 5.6 HI P 255 274 289 02 286 08 25 9 25 50 69 85 70 98 42 49 47 448 47 494 460 495 52 546 LO P 06 2 2 9 0 8 6 24 5 44 22 0 42 5 28 6 48 58 2 4 54 64 IDB = Entering Indoor Dry Bulb Temperature Shaded area reflects AHI ating conditions k = Total system power High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) 8 www.daikinac.com SS-DS

Airflow Data Tons ESP ( H2O) Standard Belt Drive Down Shot Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0. --- --- --- --- --- --- --- --- 279 0. 07 0.26 0.2 --- --- --- --- --- --- 29 0.2 24 0.28 96 0.2 0. --- --- --- --- --- --- 4 0.0 969 0.25 77 0.2 0.4 --- --- --- --- 2 0.2 977 0.29 770 0.2 --- --- 0.5 --- --- 227 0.8 029 0.0 77 0.26 --- --- --- --- 0.6 28 0.4 076 0.5 867 0.29 --- --- --- --- --- --- 0.7 25 0.40 89 0. 699 0.27 --- --- --- --- --- --- 0.8 949 0.7 696 0.29 --- --- --- --- --- --- --- --- 0.9 687 0. --- --- --- --- --- --- --- --- --- ---.0 64 0.0 --- --- --- --- --- --- --- --- --- --- ESP ( H2O) High-Static Belt Drive Down Shot Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0.6 --- --- --- --- --- --- --- --- --- --- --- --- 0.7 --- --- --- --- --- --- --- --- --- --- 222 0.40 0.8 --- --- --- --- --- --- --- --- --- --- 7 0.9 0.9 --- --- --- --- --- --- --- --- 22 0.46 02 0.8.0 --- --- --- --- --- --- 246 0.52 078 0.42 869 0.5. --- --- --- --- --- --- 26 0.49 95 0.9 725 0..2 --- --- --- --- 268 0.56 006 0.46 76 0.6 --- ---. --- --- 5 0.65 4 0.5 847 0.42 --- --- --- ---.4 --- --- 22 0.62 04 0.50 690 0.8 --- --- --- ---.5 4 0.72 090 0.58 887 0.47 --- --- --- --- --- ---.6 87 0.67 922 0.5 750 0.4 --- --- --- --- --- ---.7 060 0.6 75 0.49 --- --- --- --- --- --- --- ---.8 978 0.6 --- --- --- --- --- --- --- --- --- --- Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. SS-DS www.daikinac.com 9

Airflow Data Tons (cont.) Standard Belt Drive Horizontal ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0. --- --- --- --- --- --- --- --- --- --- 90 0.29 0.2 --- --- --- --- --- --- --- --- 249 0. 08 0.26 0. --- --- --- --- --- --- 260 0.4 077 0.28 797 0.24 0.4 --- --- --- --- 8 0.5 085 0. 856 0.26 --- --- 0.5 --- --- 4 0.4 9 0. 859 0.0 --- --- --- --- 0.6 95 0.46 70 0.8 942 0. --- --- --- --- --- --- 0.7 22 0.4 968 0.4 760 0.0 --- --- --- --- --- --- 0.8 02 0.40 756 0. --- --- --- --- --- --- --- --- 0.9 747 0.6 --- --- --- --- --- --- --- --- --- ---.0 688 0. --- --- --- --- --- --- --- --- --- --- High-Static Belt Drive Horizontal ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0.6 --- --- --- --- --- --- --- --- --- --- --- --- 0.7 --- --- --- --- --- --- --- --- --- --- --- --- 0.8 --- --- --- --- --- --- --- --- --- --- 269 0.45 0.9 --- --- --- --- --- --- --- --- --- --- 50 0.44.0 --- --- --- --- --- --- --- --- 225 0.48 988 0.40. --- --- --- --- --- --- 280 0.55 06 0.44 824 0.7.2 --- --- --- --- --- --- 4 0.52 867 0.40 --- ---. --- --- --- --- 268 0.59 96 0.48 65 0.6 --- ---.4 --- --- 2 0.68 27 0.55 766 0.4 --- --- --- ---.5 --- --- 98 0.64 986 0.52 --- --- --- --- --- ---.6 04 0.74 0 0.59 8 0.48 --- --- --- --- --- ---.7 65 0.69 828 0.54 --- --- --- --- --- --- --- ---.8 075 0.67 --- --- --- --- --- --- --- --- --- --- Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. 20 www.daikinac.com SS-DS

Airflow Data Tons (cont.) Standard Direct Drive Horizontal Standard Direct Drive Down Shot FM Static Amps atts PM Speed Tap FM Static Amps atts PM 280 0..54 60 755 270 0..5 55 760 25 0.2.5 45 800 205 0.2.5 50 80 45 0..46 5 80 Low 45 0..49 40 840 080 0.4.42 25 870 085 0.4.45 0 875 005 0.5.7 0 895 05 0.5.42 20 900 485 0..98 460 840 460 0..96 450 850 40 0.2.92 440 870 80 0.2.89 40 885 5 0..86 425 900 275 0..8 405 95 255 0.4.8 40 90 Med 75 0.4.7 400 950 70 0.5.75 400 950 075 0.5.68 80 965 075 0.6.68 80 980 005 0.6.6 70 000 945 0.7.6 60 005 95 0.7.59 60 05 445 0. 2.2 505 940 445 0. 2.2 500 950 65 0.4 2.4 490 960 40 0.4 2. 480 975 270 0.5 2.08 470 985 275 0.5 2.07 465 000 Med 80 0.6 2.02 460 000 75 0.6 2.02 455 020 050 0.7.92 45 00 040 0.7.92 40 045 825 0.8.78 400 055 80 0.8.78 95 070 Note: Assumes dry coil with filter in place; SFM correction for wet coil = 4% Speed Tap Low Med High Airflow Data 4 Tons Standard Direct Drive Horizontal Standard Direct Drive Down Shot FM Static Amps atts PM Speed Tap FM Static Amps atts PM 570 0. 2.09 490 905 548 0. 2.0 480 90 520 0.2 2.06 480 920 500 0.2 2 470 945 445 0..95 460 945 Low 425 0..89 450 970 75 0.4.89 440 970 5 0.4.8 40 995 295 0.5.8 425 995 27 0.5 75 45 020 75 0. 2.9 560 975 660 0. 2. 540 020 655 0.2 2.2 545 985 625 0.2 2.25 50 05 580 0. 2.24 525 005 565 0. 2.9 55 040 500 0.4 2.6 505 020 Med 485 0.4 2.2 505 050 405 0.5 2.09 490 05 405 0.5 2.2 500 055 05 0.6 2.00 465 050 285 0.6.98 465 060 200 0.7.92 440 065 200 0.7.9 440 070 89 0. 2.77 650 00 825 0. 2.65 620 045 770 0.2 2.70 60 040 745 0.2 2.55 600 060 696 0. 2.62 60 050 670 0. 2.5 590 065 High 6 0.4 2.5 590 060 585 0.4 2.46 575 070 50 0.5 2.44 560 070 480 0.5 2.7 550 080 48 0.6 2.6 540 085 405 0.6 2. 55 090 Speed Tap Low Med High Note: Assumes dry coil with filter in place; SFM correction for wet coil = 4% SS-DS www.daikinac.com 2

Airflow Data 4 Tons (cont.) Standard Belt Drive Down Shot ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0. --- --- --- --- --- --- 690 0.42 55 0. 0.2 --- --- --- --- --- --- 79 0.47 548 0.9 47 0.2 0. --- --- --- --- 699 0.50 570 0.44 406 0.7 258 0.0 0.4 --- --- 742 0.5 566 0.47 42 0.4 258 0.4 095 0.27 0.5 770 0.60 67 0.50 427 0.44 278 0.8 094 0.2 --- --- 0.6 664 0.57 492 0.47 286 0.4 27 0.6 --- --- --- --- 0.7 558 0.54 76 0.45 9 0.8 95 0.2 --- --- --- --- 0.8 45 0.50 220 0.4 96 0.5 --- --- --- --- --- --- 0.9 288 0.47 054 0.8 --- --- --- --- --- --- --- ---.0 2 0.4 --- --- --- --- --- --- --- --- --- ---. 95 0.9 --- --- --- --- --- --- --- --- --- --- High-Static Belt Drive Down Shot ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0.6 --- --- --- --- --- --- --- --- 688 0.58 50 0.48 0.7 --- --- --- --- --- --- 76 0.62 569 0.55 98 0.46 0.8 --- --- --- --- --- --- 6 0.59 450 0.5 268 0.4 0.9 --- --- --- --- 702 0.67 50 0.56 0.48 8 0.40.0 --- --- --- --- 589 0.64 42 0.5 90 0.45 984 0.7. --- --- 75 0.75 477 0.60 28 0.50 052 0.42 --- ---.2 755 0.85 605 0.70 64 0.57 0.46 --- --- --- ---. 640 0.80 459 0.66 224 0.5 98 0.4 --- --- --- ---.4 525 0.76 0.6 08 0.49 --- --- --- --- --- ---.5 40 0.72 92 0.57 --- --- --- --- --- --- --- ---.6 276 0.67 0 0.5 --- --- --- --- --- --- --- ---.7 7 0.6 --- --- --- --- --- --- --- --- --- ---.8 008 0.59 --- --- --- --- --- --- --- --- --- --- Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. 22 www.daikinac.com SS-DS

Airflow Data 4 Tons (cont.) Standard Belt Drive Horizontal ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0. --- --- --- --- --- --- --- --- --- --- 726 0.7 0.2 --- --- --- --- --- --- --- --- 720 0.4 575 0.6 0. --- --- --- --- 888 0.57 744 0.48 562 0.4 98 0.4 0.4 --- --- --- --- 740 0.54 579 0.45 98 0.8 27 0. 0.5 --- --- 797 0.56 586 0.5 420 0.42 26 0.6 004 0.28 0.6 849 0.62 658 0.5 429 0.48 252 0.40 997 0.2 --- --- 0.7 7 0.59 528 0.5 266 0.45 09 0.6 --- --- --- --- 0.8 572 0.55 55 0.47 068 0.4 --- --- --- --- --- --- 0.9 4 0.52 7 0.4 --- --- --- --- --- --- --- ---.0 245 0.48 987 0.9 --- --- --- --- --- --- --- ---. 059 0.44 --- --- --- --- --- --- --- --- High-Static Belt Drive Horizontal ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0.6 --- --- --- --- --- --- --- --- --- --- 669 0.5 0.7 --- --- --- --- --- --- --- --- 74 0.6 55 0.5 0.8 --- --- --- --- --- --- 792 0.66 60 0.57 408 0.48 0.9 --- --- --- --- --- --- 680 0.6 479 0.5 264 0.44.0 --- --- --- --- 765 0.7 568 0.59 2 0.50 09 0.4. --- --- --- --- 640 0.67 422 0.55 68 0.46 --- ---.2 --- --- 784 0.78 55 0.64 259 0.5 995 0.4 --- ---. 82 0.89 62 0.7 60 0.59 09 0.47 --- --- --- ---.4 694 0.84 458 0.68 202 0.55 --- --- --- --- --- ---.5 567 0.80 24 0.6 042 0.5 --- --- --- --- --- ---.6 47 0.75 48 0.59 --- --- --- --- --- --- --- ---.7 262 0.70 --- --- --- --- --- --- --- --- --- ---.8 20 0.66 --- --- --- --- --- --- --- --- --- --- Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. SS-DS www.daikinac.com 2

Airflow Data 5 Tons Standard Direct-Drive Horizontal Standard Direct-Drive Down Shot FM Static Amps atts PM 25 0..4 65 60 Speed Tap FM Static Amps atts PM 205 0..47 80 65 50 0.2.46 75 645 50 0.2.54 85 675 085 0..54 80 690 065 0..59 85 70 00 0.4.64 95 725 980 0.4.68 95 760 900 0.5.74 205 780 860 0.5.79 200 80 840 0.6.77 25 80 800 0.6.82 220 840 95 0..86 20 670 75 0..94 25 690 25 0.2.95 240 705 00 0.2 2.0 245 720 260 0. 2.0 250 75 20 0. 2.05 255 750 20 0.4 2.0 260 770 80 0.4 2.5 265 790 5 0.5 2.6 265 80 00 0.5 2.22 275 80 040 0.6 2.28 280 860 005 0.6 2. 285 890 970 0.7 2.8 290 885 970 0.7 2.4 295 900 90 0.8 2.46 00 925 95 0.8 2.5 0 940 840 0.9 2.52 0 955 845 0.9 2.57 5 980 790 0..24 425 80 755 0..4 85 850 75 0.2.7 45 80 700 0.2.47 95 865 670 0..45 450 865 665 0..56 40 895 60 0.4.55 465 890 580 0.4.68 425 90 560 0.5.60 475 920 T 545 0.5.72 45 955 520 0.6.70 490 945 505 0.6.80 520 990 470 0.7.80 500 970 40 0.7.9 50 020 40 0.8.94 50 995 70 0.8 4.08 55 040 45 0.9.98 50 05 00 0.9 4.2 570 070 2005 0. 4.0 575 880 945 0. 4.46 600 920 965 0.2 4.4 590 900 90 0.2 4.57 620 940 895 0. 4.52 60 90 850 0. 4.66 65 965 85 0.4 4.6 620 955 795 0.4 4.78 655 990 790 0.5 4.75 65 980 T4 760 0.5 4.84 670 020 745 0.6 4.84 650 005 70 0.6 4.96 685 045 695 0.7 4.9 660 00 640 0.7 5.06 675 065 650 0.8 5.0 675 055 60 0.8 5.9 690 090 600 0.9 5.0 675 080 560 0.9 5.22 700 25 220 0. 5.0 690 90 2090 0. 5.5 720 970 2075 0.2 5.5 70 950 2040 0.2 5.8 740 990 2025 0. 5.2 720 975 985 0. 5.70 755 025 975 0.4 5.5 75 995 95 0.4 5.44 760 05 90 0.5 5.46 750 020 T5 900 0.5 5.82 780 050 875 0.6 5.59 770 040 855 0.6 5.7 800 075 85 0.7 5.64 780 065 80 0.7 5.69 80 090 795 0.8 5.7 790 090 750 0.8 5.82 825 20 75 0.9 5.82 805 0 680 0.9 5.94 840 45 Speed Tap T T4 T5 Notes Assumes dry coil with filter in place; SFM correction for wet coil = 4% Five-ton models are shipped from the factory with speed tap set on T4. 24 www.daikinac.com SS-DS

Airflow Data 5 Tons (cont.) ESP ( H2O) Standard Belt Drive Down Shot Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0. --- --- --- --- 207 0.62 972 0.54 86 0.4 668 0.4 0.2 --- --- 280 0.70 977 0.59 846 0.5 699 0.9 5 0. 0. 20 0.79 2066 0.66 87 0.56 72 0.47 572 0.5 87 0.0 0.4 2024 0.76 950 0.6 769 0.5 596 0.44 44 0. 247 0.27 0.5 97 0.7 8 0.60 64 0.50 554 0.4 02 0.0 --- --- 0.6 85 0.69 76 0.56 52 0.46 0 0.8 --- --- --- --- 0.7 764 0.65 60 0.5 9 0.42 86 0.4 --- --- --- --- 0.8 65 0.6 477 0.49 256 0.9 --- --- --- --- --- --- 0.9 54 0.57 50 0.45 --- --- --- --- --- --- --- ---.0 4 0.5 80 0.40 --- --- --- --- --- --- --- ---. 270 0.49 --- --- --- --- --- --- --- --- --- --- ESP ( H2O) High-Static Belt Drive Down Shot Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0.6 --- --- --- --- --- --- 2227 0.86 2050 0.7 0.7 --- --- --- --- --- --- 202 0.82 92 0.69 0.8 --- --- --- --- --- --- 2274 0.9 999 0.79 820 0.67 0.9 --- --- --- --- 204.0 20 0.88 859 0.76 60 0.6.0 --- --- --- --- 262 0.98 200 0.86 694 0.72 487 0.59. --- --- 225.5 2027 0.94 820 0.79 54 0.68 267 0.55.2 255.26 2247. 902 0.90 72 0.77 0.6 --- ---. 2247.22 2062.05 768 0.87 557 0.7 --- --- --- ---.4 25.9 92.0 579 0.82 74 0.66 --- --- --- ---.5 2004.4 768 0.95 9 0.74 --- --- --- --- --- ---.6 895.0 67 0.9 --- --- --- --- --- --- --- ---.7 727.04 0.80 --- --- --- --- --- --- --- ---.8 9 0.92 --- --- --- --- --- --- --- --- --- --- Note: Tables represent dry coil without filter; to compensate for filter, add 0.08 to measured E.S.P. SFM correction for wet coil = 4%. SS-DS www.daikinac.com 25

Airflow Data 5 Tons (cont.) Standard Belt Drive Horizontal ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0. --- --- --- --- --- --- 205 0.49 940 0.40 0.2 --- --- --- --- --- --- 247 0.57 975 0.47 782 0.9 0. --- --- --- --- 278 0.6 200 0.5 828 0.4 6 0.6 0.4 --- --- --- --- 2057 0.60 855 0.50 678 0.4 450 0. 0.5 --- --- 2 0.68 90 0.57 69 0.47 55 0.8 252 0.29 0.6 252 0.78 995 0.64 77 0.5 546 0.44 20 0.4 --- --- 0.7 205 0.74 862 0.6 620 0.49 79 0.40 --- --- --- --- 0.8 922 0.70 78 0.57 46 0.46 202 0.7 --- --- --- --- 0.9 784 0.66 570 0.5 296 0.4 --- --- --- --- --- ---.0 64 0.62 7 0.48 --- --- --- --- --- --- --- ---. 477 0.58 200 0.44 --- --- --- --- --- --- --- ---.2 292 0.5 --- --- --- --- --- --- --- --- --- --- High-Static Belt Drive Horizontal ESP ( H2O) Turns Open 0 2 4 5 FM BHP FM BHP FM BHP FM BHP FM BHP FM BHP 0.6 --- --- --- --- --- --- 264 0.89 985 0.76 0.7 --- --- --- --- --- --- 222 0.99 2047 0.85 858 0.72 0.8 --- --- --- --- --- --- 204 0.95 94 0.82 75 0.70 0.9 --- --- --- --- 2200.09 995 0.92 89 0.79 60 0.67.0 --- --- 2297.22 2086.06 900 0.89 687 0.75 40 0.62. --- --- 2204.9 995.02 774 0.86 54 0.7 --- ---.2 2249.2 20.5 875 0.99 624 0.8 52 0.66 --- ---. 275.28 958. 740 0.94 482 0.77 --- --- --- ---.4 2072.25 86.06 587 0.89 08 0.72 --- --- --- ---.5 945.20 685.00 402 0.8 --- --- --- --- --- ---.6 84.5 59 0.94 --- --- --- --- --- --- --- ---.7 684.09 --- --- --- --- --- --- --- --- --- ---.8 54.0 --- --- --- --- --- --- --- --- --- --- Air Flow Pressure Drop of Down Flow Economizer Airflow Pressure Drop of Downflow Economizer for to 6 Ton offtop Units (00% eturn Air) SF, 800 000 200 400 600 800 2000 2200 2400 2600 2800 in 0.02 0.04 0.05 0.07 0.09 0.2 0.4 0.7 0.2 0.24 0.28 26 www.daikinac.com SS-DS

rankcase Heater, High Efficiency MEV Air Filter Option High Efficiency MEV Air Filter Option 0.50 Flanders Pre Pleat M Air Velocity vs esistance (Test Size: 24" x 24" x 2" High apacity) 0.45 0.40 2" Deep esistance (in. w.g.) 0.5 0.0 0.25 0.20 0.5 0.0 0.05 0.00 0 00 200 00 400 500 600 700 Air Velocity (FPM) Tonnage: Filter Nominal Size: Part Number: Order QTY: 24 x 24 x 2 060L0020 4 4 x 20 x 2 060L00204 4 5 6 x 20 x 2 060L00205 4 rankcase Heater Selection Table ompressor Voltage rankcase ZP/ZPS ompressor Diameter 20V 460V 575V Heater atts 6-5.5" 0600002S 06000S 060002S 40 9-8 6.58/7." 00L0007S 00L0008S 00L0009S 70 0-7 9.4 00L00020S 00L0002S 00L00022S 90 D*,DT* & DS* Tonnage ompressor Voltage 20V 460V 575V rankcase Heater atts Ton 0600002S 06000S 060002S 40 4 Ton-5 Ton 00L0007S 00L0008S 00L0009S 70 *Includes,&H models. SS-DS www.daikinac.com 27

Electrical Data Tons Model Number Electrical ating ompressor ircuit ompressor ircuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered onvienience Outlet Power Supply LA LA LA LA QTY HP FLA Type HP FLA FLA MA MOP DS06XXXD 208/20--60 6.7 79.0 0.25.40 DS06XXXB 208/20--60 0.4 7.0 0.25.40 DS06XXXD 208/20--60 0.4 7.0 0.25.40 DS06XXXH 208/20--60 0.4 7.0 0.25.40 DS06XXX4B 460--60 5.8 8.0 0.25 0.70 DS06XXX4H 460--60 5.8 8.0 0.25 0.70 DS06XXX7B 575--60.8 6.5 0.25 0.55 Standard - Direct Drive Standard - Direct Drive Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive 0. 2.46.50.40 0. 2.46.50 4.60.00.70.50 2.0.50 2.0-24.7 / 24.7 40 / 40 7.2 / 6.5.9 /.2 45 / 45-6.9 / 6.9 25 / 25 7.2 / 6.5 24. / 2.4 0 / 0-7.9 / 7.9 25 / 25 7.2 / 6.5 25. / 24.4 5 / 0-9. / 9. 25 / 25 7.2 / 6.5 26. / 25.6 5 / 5-9.6 5. 2.9 5-0.0 5.. 5-7.6 5 2.6 0.2 5 4 Tons Model Number Electrical ating ompressor ircuit ompressor ircuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered onvienience Outlet Power Supply LA LA LA LA QTY HP FLA Type HP FLA FLA MA MOP DS048XXXD 208/20--60 9.9 09.0 0.25.40 DS048XXXD 208/20--60. 8.0 0.25.40 DS048XXXB 208/20--60. 8. 0.25.40 DS048XXXH 208/20--60. 8. 0.25.40 DS048XXX4B 460--60 6. 4.0 0.25 0.70 DS048XXX4H 460--60 6. 4.0 0.25 0.70 DS048XXX7B 575--60 4.4.0 0.25 0.55 Standard - Direct Drive Standard - Direct Drive Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive 0.75 2.80 0.75 2.80.00.40.50 4.60.00.70.50 2.0.50 2.0-29.0 / 29.0 45 / 45 7.2 / 6.5 6.2 / 5.5 50 / 50-20.6 / 20.6 0 / 0 7.2 / 6.5 27.8 / 27. 40 / 40-2.2 / 2.2 0 / 0 7.2 / 6.5 28.4 / 27.7 40 / 40-22.4 / 22.4 5 / 5 7.2 / 6.5 29.6 / 28.9 40 / 40-0.0 5.. 5-0.4 5..7 5-8. 5 2.6 0.9 5 5 Tons Model Number Electrical ating ompressor ircuit ompressor ircuit 2 Outdoor Fan Motor Indoor Fan Motor Optional Powered onvienience Outlet Power Supply LA LA LA LA QTY HP FLA Type HP FLA FLA MA MOP DS060XXXD 208/20--60 26.4 4.0 0.25.40 DS060XXXD 208/20--60 6.0 0.0 0.25.40 DS060XXXB 208/20--60 6.0 0.0 0.25.40 DS060XXXH 208/20--60 6.0 0.0 0.25.40 DS060XXX4B 460--60 7.8 52.0 0.25 0.70 DS060XXX4H 460--60 7.8 52.0 0.25 0.70 DS060XXX7B 575--60 5.7 8.9 0.25 0.55 Standard - Direct Drive Standard - Direct Drive Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive High Static - Belt Drive Standard - Belt Drive.00 6.90.00 6.90.00.20.50 4.80.00.50.50 2.40.00.20-4. / 4. 60 / 60 7.2 / 6.5 48.5 / 47.8 70 / 70-28. / 28. 40 / 40 7.2 / 6.5 5.5 / 4.8 50 / 50-24.6 / 24.6 40 / 40 7.2 / 6.5.8 /. 45 / 45-26.2 / 26.2 40 / 40 7.2 / 6.5.4 / 2.7 45 / 45 -.9 5. 5.2 20-2.8 20. 6. 20-8.9 5 2.6.5 5 28 www.daikinac.com SS-DS

Dimensions TOP VIE.265.805 FLUE/VENT OUTLET OMBUSTION AI INLET (AS UNITS) AS LINE ENTANE 7.945 FONT VIE ALL DIMENSIONS IVEN AE IN INHES ALL DIMENSIONS AND SPEIFIATIONS AE SUBJET TO HANE ITHOUT NOTIE SUPPLY AI DUT 2.000 4.475 0.060 6.96 DS06-060 THU 5 TON OMMEIAL.540.000 7.65 7.000 ONDENSATE DAIN OUTLET LIFTIN SHAKLE HOLES BOTH SIDES AND ENDS 48.96 FK HOLES BOTH SIDES AND BOTH ENDS 20.85 IHT END VIE ETUN AI DUT SS-DS www.daikinac.com 29

Dimensions (cont.) 9.470 5.04 2.000 ONDENSATE DAIN BOTTOM EXIT MOD TON AS, HT M 4 TON AS, HT M 5 TON AS, HT M 6 TON AS, HT M SUPPLY AI DUT 7.000 48.2 2.442.000 20.905 6.92 5.558 25.000 ETUN AI DUT 74.06 BASE PAN VIE (VIEED FOM TOP) ONDENSATE DAIN BOTTOM EXIT MODEL TONNAES "A" "B" "" TON OMMEIAL AS, HT MP, AI ONDITIONE 8.840 6.555 26.055 4 TON OMMEIAL AS, HT MP, AI ONDITIONE 8.840 6.555 26.055 5 TON OMMEIAL AS, AI ONDITIONE 8.840 6.555 26.055 5 TON OMMEIAL HT MP 42.840 20.555 0.055 7.984 LINE IE ENTANE "A" "" "B" 8.555 T IE ENTANE 5.872 0.72 LEFT END VIE UN AI DUT 74.06 0 www.daikinac.com SS-DS ASE PAN VIE ED FOM TOP)

Unit learances Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a clearance of 48" on all sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit Beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit s fresh-air intake. 48" 48" Electrical Entrance Locations 48" 48" High-Voltage Entrance (emove Plug) Low-Voltage Entrance 2⅜ ½ Dia. 0¼ Power Thru the urb Low-Voltage Entrance 47½ 7½ orner & enter-of-ravity Locations Unit eights -Ton eights 4-Ton eights 5-Ton eights 0 ondenser oil eturn Evaporator oil Supply orner eight (A) 09 orner eight (B) 78 92 94 orner eight () 09 8 9 orner eight (D) 79 92 94 Unit Shipping eight 600 65 620 Unit Operating eight 575 640 645 ompressor 7 Note: eights are calculated without accessories installed. SS-DS www.daikinac.com

oof urb Installation igging Provisions for forks have been included in the unit base frame. No other fork locations are approved. Unit must be lifted by the four lifting holes located at the base frame corners. Lifting cables should be attached to the unit with shackles. The distance between the crane hook and the top of the unit must not be less than 60. Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. emove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. efer to rigging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in oof urb Installation Instructions Manual. efer to the oof urb Installation Instructions for proper curb installation. urbing must be installed in compliance with the National oofing ontractors Association Manual. Lower unit carefully onto roof mounting curb. hile rigging the unit, the center of gravity will cause the condenser end to be lower than the supply air end. Bring condenser end of unit into alignment with the curb. ith condenser end of the unit resting on curb member and using curb as a fulcrum, lower opposite end of the unit until entire unit is seated on the curb. hen a rectangular cantilever curb is used, take care to center the unit. heck for proper alignment and orientation of supply and return openings with duct. To assist in determining rigging requirements, unit weights are shown below. urb installations must comply with local codes and should follow the established guidelines of the National oofing ontractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. heck for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package. Determine sufficient structural support before locating and mounting the curb and package unit. Duct-work must be constructed using industry guidelines. The duct-work must be placed into the roof curb before mounting the package unit. Our full perimeter curbs include duct connection frames to be assembled with the curb. antilevered-type curbs are not available from the factory. ontractor furnishes curb insulation, cant strips, flashing, and general roofing material. Support curbs on parallel sides with roof members. To prevent damage to the unit, the roof members cannot penetrate supply and return duct openings. Note: The unit and curb accessories are designed to allow vertical duct installation before unit placement. Duct installation after unit placement is not recommended. See the manual shipped with the roof curb for assembly and installation instructions. -D View Insulated Panels Top View 70¾ 40¼ 4 x 20 Supply Opening ⅝ x 4 eturn Opening 4 5 6 ¾ 4 ⅜ 2 www.daikinac.com SS-DS