SOGAV 250 Solenoid Operated Gas Admission Valve

Similar documents
VariStroke II Electro hydraulic Actuator

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

ELV Electric Liquid Fuel Valve

VariStroke I Electro hydraulic Actuator

VariStroke I Electro hydraulic Actuator

APECS 0225 Linear Actuators

APECS Linear Actuators APPLICATIONS DESCRIPTION

Application Guidelines for TecJet with E3 Fuel Blending System. Application Note (Revision NEW, 4/2010) Original Instructions

SOGAV Solenoid Operated Gas Admission Valve. Product Manual (Revision J) Original Instructions. Unbalanced, Bottom-Load SOGAV 250

SOGAV Solenoid Operated Gas Admission Valve Pre-Combustion Chamber (PCC) Valve. Product Manual (Revision P, 11/2016) Original Instructions

Operation and Maintenance Manual. PG Governor Dial Type Speed Setting. Manual (Revision D)

Application Note Original Instructions Development of Gas Fuel Control Systems for Dry Low NOx (DLN) Aero-Derivative Gas Turbines

pplication Note (Revision A) Original Instructions Replacing the ST-125 Engine Control with an L-Series Speed Controller

SOGAV Solenoid Operated Gas Admission Valve. Product Manual (Revision P, 11/2015) Original Instructions

Installation Instructions. Bosch RSV Governor Shutdown Kit with 1751 & 1751ES Solenoids. Manual (Replaces SE-3042 Rev C)

Application Note Original Instructions. Gas Fuel Control Valve (GFCV) O-ring Field Replacement Procedure

Installation Instructions. APECS 0250 Kit Isuzu 4BG1-TRV Engine. Installation Instructions. Right-Hand Version. Manual 36561

Installation Kit. Product Manual (Revision NEW) Original Instructions

Installation Manual Installation Kit. for EPG 1712/1724 Electric Actuator on the Caterpillar D3406 Engine. Manual 54086

Product Manual (Revision A) Original Instructions. EG-3P Actuator Installation on Detroit Diesel V-149 Engine. Kit Installation Manual

Illustrated Parts Catalogue Woodward Diesel Systems. Illustrated Parts Catalogue. Perkins Engines (formerly Rolls-Royce) Pumps & Injectors

Manual Solenoid Shutdown Kits

Product Manual (Revision P, 7/2013) Original Instructions. Liquid Shutoff Valve 25 (LSOV25) Installation and Operation Manual

Safety Standards. Model Number:

Installation Manual Installation Kit. for EPG 1712/1724 Electric Actuator on the Caterpillar 3208 Engine. Manual (Revision A)

Product Manual (Revision NEW) Original Instructions. PGA-EG, PGG-EG, PGM-EG 12/29/58 Governor/Actuator. Installation Manual

Product Manual (Revision A) Original Instructions. Manifold Gauge Pressure Fuel Limiter for PG Governors. Operation Manual

Application Note. Controllers for Stanadyne Pumps Using DC Integrated Actuators. Calibration Instructions. Manual 36579

Installation, Programming, & Troubleshooting Manual for OEM/Dealer. L-Series ITB LC-50. Manual (Revision D)

Product Manual (Revision NEW) Original Instructions. PGA-EG, PGG-EG, PGM-EG 200/300/500 Governor/Actuator. Installation Manual

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

Illustrated Parts Catalogue Woodward Diesel Systems. Illustrated Parts Catalogue. Perkins Engines (formerly Perkins Dorman) Pumps & Injectors

Installation Instructions. APECS Actuator Kit for Daihatsu Engines (DM 950D) Installation Instructions. Manual 36588

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

1. TECHNICAL SPECIFICATIONS & OPERATION MANUAL

Product Manual (Revision H) Original Instructions. Solenoid Operated Shutdown Assembly for PGA and PGPL. Operation Manual

GO Range. Gas-over-Oil Valve Actuators. Redefining Flow Control

HPG Range. Direct High-Pressure Gas Valve Actuators. Redefining Flow Control

Product Manual (Revision A) Original Instructions. Speed Droop Mechanism for PG Dial Governor. Operation Manual

Product Manual (Revision NEW) Original Instructions. Synchronous Motor Operated Potentiometer Operation Manual

BGD258 Series BASOTROL CE Approved Class A Gas Valve

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Operator Instructions for Tension Links

Product Manual (Revision D) Original Instructions. PM Speed Adjusting Motor for UG-8 Governors. Operation Manual

UG-8 Speed Adjusting Devices. Product Manual (Revision NEW) Original Instructions. Pneumatic and Manifold Speed Setting for UG Type Governors

SPV Series Slides OPERATING MANUAL. Table of contents 1 Introduction Compliance with the EC Directives Names of parts...

Block mounting filter, for vertical flange-mounting

PRODUCT SPECIFICATION

Pneumatic actuator Assembly & maintenance procedures

Poppet Valves Series. Keeping the World Flowing

EPG 1712/1724 or 512/524 Electric Actuator Installation. Product Manual (Revision NEW) Original Instructions

Illustrated Parts Catalogue. Illustrated Parts Catalogue Woodward Diesel Systems. GE Transportation Systems Pumps & Injectors.

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

MPS AND MPS PR¼ 16 OUTPUT DEMAND CONTROLLER PENTAIR CLEAN AIR SYSTEMS. AVS Danmark ApS Skelvej Hedehusene

BGD278 Series BASOTROL CE Approved Gas Valve

Block mounting filter, for lateral flange-mounting

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

Product Manual (Revision G) Original Instructions. Auxiliary Devices for UG-40 Governors used in Marine Service.


Block mounting filter, for lateral flange-mounting

CETOP POSITION PAPER PP 07

IQL Helios Area-/Streetlight. User Manual

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

FUELING PROGRESS. Diesel & Gas Engine Solutions

Inline filter with filter element according to DIN 24550

Product Manual (Revision C) Original Instructions. Air/Fuel Ratio Control. Installation and Operation Manual

Inline filter with filter element according to DIN 24550

PNEUMATIC ACTUATORS ASSEMBLY & MAINTENANCE PROCEDURES. Ref. Doc. MMMACTREGDRE English Rev.2 January 2012 ADA & ASR SERIES DOUBLE ACTING ACTUATOR ADA

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

STANDARD FOR TESTING AND RATING PERFORMANCE OF PRESSURE WASHERS: DETERMINATION OF PRESSURE AND WATER FLOW

Solenoid Operator 0513 / 1213

Line filter with filter element according to DIN 24550

Installation and Operation Manual. ProAct III / IV Electric Powered Actuator and Driver. Manual 04127B

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets

Inline filter with filter element according to DIN 24550

10 S e r i e s PRESSURE SWITCH. features

Replacement cartridge filter

J 6 Se r i e s. Pressure and Vacuum switches. features

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

3M CP2 Press-Fit Headers and Sockets, 2 mm

Intelivalve Solenoid Pinch Valve

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

Engine Performance 1500 RPM

BARTON 7400 Precision Gas Turbine Flow Meters

4 Redundant Control System

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

DETAIL SPECIFICATION SHEET

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2

HOKE Monoflange Valves. Primary Isolation Valves

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

Pete Jacobs. Business Development Manager Wartsila North America, Inc. (281)

Type I/P & E/P Transducers

Solenoid Operator 0516 / 1216

Block mounting filter, for sandwich plate mounting

File In/With: Equipment Affected:

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Application Note (Revision NEW) Original Instructions. Governor Linkages for Butterfly Throttle Valves

NUMBER: S.M. REF.: Refer to 2.5 ENGINE: 60 DATE: January 2007

Transcription:

SOGAV 250 Solenoid Operated Gas Admission Valve Product Specification 03316 (Revision M, 11/2015) Applications The SOGAV (Solenoid Operated Gas Admission Valve) 250 is an electrically actuated, high-response gas admission valve for in-manifold (port) fuel admission. The SOGAV 250 valve is designed for use on four-cycle, natural gas or dual-fuel engines. One SOGAV valve is required for each cylinder. The SOGAV 250 valve is the electromechanical valve portion of an overall Woodward fuel admission system consisting of: In-Pulse electronic fuel injection control Main speed/air-fuel ratio/engine sequencing control (must regulate air manifold pressures as well as fuel admission). Other necessary valves, actuators, regulators, sensors, cables and safety devices Governing is performed via valve opening duration, and individual cylinders can be duration or timing bias within the In-Pulse control. The SOGAV 250 valve s E-core solenoid has a short travel and high output force which result in fast and consistent closing response. The valve is a face-type poppet with multiple concentric grooves. The moving metering plate is spring- and pressureloaded in the closed direction. Port fuel admission for improved cylinderto-cylinder control All-electric actuation Fast response Simple installation Electronic fuel injection technology for four-stroke engines For new engines and retrofits Works with Woodward In-Pulse electronics Certified for North American Hazardous Locations Compliant with applicable CE Directives -- EMC, Low Voltage, ATEX, Machinery, Pressure Equipment

Specifications Woodward 03316 p.2 CONSTRUCTION Materials Mounting Gas Inlet Hole Diameter All parts exposed to the gas are resistant to corrosion and stress corrosion cracking. May be mounted in any configuration with the solenoid axis greater than horizontal, placing the solenoid higher than the metering plates. However, a vertical orientation (valve inlet facing upward) is preferred and will substantially increase valve life versus a horizontal orientation. Intake manifold runner (mating surface) must have 95 110 mm opening. 95 mm ENVIRONMENT Operating Temperature 20 to +105 C ( 4 to +221 F) 8402-249, -251 20 to +95 C ( 4 to +203 F) 8402-250, -255 Vibration Humidity, Salt Spray, Pressure Wash Contact Woodward for vibration qualification data and analysis The unit withstands exposure to pressure washing, salt spray, etc., without adverse corrosion or infiltration. PERFORMANCE Response (assumes the use of a Woodward In-Pulse control): Unbalanced SOGAV 250 Balanced SOGAV 250 Time to full open after signal on 0.0050 s max same Time to full closed after signal off 0.0050 s max same Maximum Leakage When Closed < 100 SCFH same Filtration Required for Long Life 5 µm absolute max particle size same Expected Maximum Gas Supply Pressure (P1) 450 kpa (4.5 bar abs; 65 psi abs) 650 kpa (6.5 bar abs; 94 psi abs) Expected Maximum Air Manifold Pressure (P2) 300 kpa (3.0 bar abs; 43 psi abs) 400 kpa (4.0 bar abs; 58 psi abs) Maximum Gas Manifold to Air Manifold Maximum Pressure Difference 150 kpa (1.5 bar; 22 psi) 250 kpa (2.5 bar; 36 psi) Minimum Pressure Difference 100 kpa (1.0 bar, 14.5 psi) n/a Maximum Backfire Pressure Spike (without backflowing through valve) 50 kpa (0.5 bar; 7 psi) above same the current gas manifold pressure Expected Maximum Gas Supply Temperature 80 C (176 F) same REGULATORY COMPLIANCE (Hazardous Locations listings are limited to solenoid only.) European Compliance for CE Marking: Low Voltage Directive 2006/95/EC ATEX Directive 94/9/EC Zone 2, Category 3, Group II G, EEx m II T4 X Other European Compliance: (Compliance with the following European Directives or standards does not qualify this product for application of the CE Marking.) EMC Directive 2004/108/EC Not applicable to this product. Electromagnetically passive devices are excluded from the scope of the 2004/108/EC Directive. Machinery Directive 2006/42/EC Compliant as partly completed machinery Pressure Equipment Directive 97/23/EC Exempt per Article 1-3.10 North American Compliance: (Certified as a component for use in other equipment only.) CSA CSA Certified for Class I, Division 2, Groups A, B, C, D T4 at 105 C Ambient for use in Canada and the United States REFERENCE MANUALS 26114 SOGAV 250 (unbalanced, bottom-load version) Installation and Operation Manual 26500 SOGAV 250 (pressure-balanced, top-load version) Installation and Operation Manual

SOGAV 250 Outline Drawing (Unbalanced/Bottom-Load) (Flying Lead Version) Woodward 03316 p.3

SOGAV 250 Outline Drawing (Unbalanced/Top-Load) (Flying Led version) Woodward 03316 p.4

Woodward 03316 p.5 In-manifold Electric Gas Admission Timing: In-manifold Gas Admission PO Box 1519, Fort Collins CO, USA 80522-1519 1000 East Drake Road, Fort Collins CO 80525 Tel.: +1 (970) 482-5811 www.woodward.com For more information contact: Distributors & Service Woodward has an international network of distributors and service facilities. For your nearest representative, call the Fort Collins plant or see the Worldwide Directory on our website. This document is distributed for informational purposes only. It is not to be construed as creating or becoming part of any Woodward contractual or warranty obligation unless expressly stated in a written sales contract. Copyright Woodward, Inc. 2003 2015, All Rights Reserved