Series information KEP_0_EN Drainage pumps - Overview of products - Executions - Materials - Sectional and dimensional drawings
General description Drainage pumps series KEP are single stage, normal priming centrifugal pumps with a long shaft and column pipe for mounting into pits and sumps. Versions with a mounting length as from,6 have grease lubricated guide bearings. Fields of application Main field of application of the drainage pumps series KEP is the drainage of pits and sumps in which no submersible pump can or should be used. The advantage of the motor on the top is the easier maintenance, the dry set up of the motor and the thus following saving of costs. Most of our KEP pumps are used in the following purposes: - Drainage of garage and basements - Discharging of tanks - Recirculation of liquids in holding tanks Operating data Flow: Total head: Motor power: Q up to 6 m³/h H up to m P from 0, kw to, kw Degrees of protection: IP or IP 6 Connections The pump is suctioning directly at the bottom of the casing. The pressure connection is equipped with a threaded counter flange according to DIN - PN 6. Connections with different dimensions of threads or flanges are available on request. Motors As motors are single or triple phase induction motors with fixed bearing at the drive end used. Voltages: for ~ execution: 0V, 0Hz for ~ execution: Degree of protection: IP or IP 6 up to.kw 0/0V, 0Hz from kw 0/690V, 0Hz up to.6kw 6/60V, 60Hz from.6kw 60V, 60Hz other voltages/frequencies are available on request. Direction of rotation: Clock-wise viewed onto fan cover.
Type Code KEP-F ½ -, - D - SW Series Execution of impeller Nominal size of discharge connection Mounting length Type of motor Float switch Series: KEP KEPL - Standard version - Pump with bearing bracket and flexible coupling Execution of impeller: B F - Standard version with closed channel type impeller - Channel type impeller with special geometry - Pump with vortex impeller The free passage through the impeller is mm for the KEP ½, 0 mm for the KEP and mm for the KEP ½. Nominal size of discharge connection: See dimensional drawing, characteristic curve resp. Mounting length: Type of motor: Length in meters D - Triple phase motor ~ W - Single phase motor ~ Float switch: SW - Without float switch - Float switch with hand-automatic-selection-switch and overload protection Materials Material code Part Casing Impeller Y0 Cast iron - GG Cast iron - GG 0 Standard - Y0 Cast iron - GG Cast iron - GG 0 Y0 Bronze Bronze Shaft Chromium steel -. Duplex -.6 Y0 Stainless steel - 6 Stainless steel - 6 Column pipe Carbon steel Stainless steel - 6 -.7 Material Cast iron German description German material code number EU - Description EU - material code number ASTM - UNS - description GG 0 0.600 EN-GJL-00 JL 00 A - Grade 0 GG 0.60 EN-GJL-0 JL 0 A - Grade Bronze G-CuSn0.00.0 CuSn0-C CC0K-GS B0 - C90700 Steel St 7.007 SJR.007 A9-0 Sliding bearing Lantern Cast iron - GG 0 Bronze Cast iron - GG 0 Additionally for KEPL Bearing bracket Cast iron - GG 0 Bearing housing Cast iron - GG 0 Bronze Carbon Stainless steel - 6 -.7 Chromium steel X0 Cr. X0Cr. A76 - S000 Stainless steel - 6 Duplex G-XCrNiMo 9-- X6 CrNiMoTi 7-- X CrNiMoN --..7.6 GXCrNiMo 9-- X6CrNiMoTi 7-- X CrNiMoN --. A - CFM - J9900.7 A76 - S6.6 A76 -S0 Other materials are available on request.
Characteristic curve KEP ½, KEP und KEP ½ H [m] 0 0Hz - 00min - H [m] 0 60Hz - 00min - 0 0 KEP ½ 0 KEP ½ 0 KEP KEP KEP ½ KEP ½ 0 0 0 00 Q [m³/h] 0 0 0 00 Q [m³/h] Characteristic curve KEP-F ½, KEP-F und KEP-F ½ H [m] 0 0Hz - 00min - H [m] 0 60Hz - 00min - 0 0 KEP ½ 0 KEP KEP ½ 0 KEP ½ KEP KEP ½ 0 0 0 00 Q [m³/h] 0 0 0 00 Q [m³/h] Characteristic curve KEP-F ½ H [m] 0 0Hz - 000min - H [m] 0 60Hz - 600min - 0 0 KEP ½ KEP ½ 0 0 0 0 0 00 Q [m³/h] 0 0 0 00 Q [m³/h]
Dimensional drawing KEP(L) ½, KEP(L) und KEP(L) ½ H ET h b b b b DND H KEP ET a h H b b b b ET DND h KEPL with intermediate bearings b b b b a DND KEPL a
Dimensional drawing KEP(L) ½, KEP(L) und KEP(L) ½ Type DN a b b b b h KEP(L) ½ G ½ 9 0 0 0 KEP(L) G 7 9 KEP(L) ½ G ½ 70 9 7 Type KEP ½ KEP-F ½ KEPL ½ KEPL-F ½ KEP KEP-F KEPL KEPL-F KEP ½ KEP-B ½ KEP-F ½ KEPL ½ KEPL-B ½ KEPL-F ½ Mounting length (ET) Motor 0,6 m,0 m, m,6 m m, m,6 m kw n [min-] H kg H kg H kg H kg H kg H kg H kg 0, - ~ 0,, 0,/0,66 0/70 0 9 6 0,7 - ~ 0 7 0, 0,7/0,9 0/70 0, - ~ 0 7,, 9,, 0,/0,66 0/70 0,7 - ~ 0 6 76 0 70 9 7 9,,, 0,7/0,9 0/70,/, 900/00 9,,, 6,/, 900/00 9 9,,, 6 6 76 0 70 9 7,/,6 900/00 9,, 9, 9 6,0/,6 900/00 6 9, 76, 0 60, 70 6 9 70 7 7,0/, 900/00 6 9, 76, 0 6, 70 6 9 7 7 7 0,7 - ~ 0, 7 69 6 0,7/0,9 0/70, - ~ 0, 6,/, 0/70 7 69, - ~ 0, 6,/, 0/70, - ~ 0, 9 7 6,/,6 0/70 0,7 - ~ 0 7 9 0, 0, 60 96 9 6 0,7/0,9 0/70, - ~ 0 7 9, 6, 60 66 69,/, 0/70 7 99 9 60 009 9, - ~ 0 9,, 6 6 7,/, 0/70, - ~ 0 7 6 6 7, 0 6, 60 69 0 7 6 7,/,6 0/70, - ~ 0 9, 6 6,/,6 0/70 60 0 760,0/,6 0/70 9, 6 6,0/, 0/70 60 6 0 7, 760 7,, - ~ 0 67 70 7, 79, 9 9,/,6 0/70 9 6 9 0 700 0,0/,6 0/70 67 7 7,, 9 9,0/, 0/70 9 7, 667 7, 97 7 7 9, 077 97, 7 00, Greater mounting length on request.
Sectional drawing KEP(-F) ½, KEP(-F), KEP(-F) ½ KEP Part-No. Description 0 Casing 6 Casing cover 0 Shaft 0 Impeller 0 Sliding bearing Lantern 7 Column pipe 0 Motor 9 Sleeve coupling The pumps version KEP without bearing are only available up to an mounting length of. m. For taller mounting length the pumps version KEPL with bearing are used. This version is equipped with one intermediate bearing for the mounting lengths.6 m and.00 m and with two intermediate bearings for the mounting lengths.0 m and.6 m. 6
Sectional drawing KEPL(-F) ½, KEPL(-F), KEPL(-F) ½ Part-No. Description 0 Casing 6 Casing cover 0 Shaft 0 Impeller 0 Sliding bearing 0.0 Sliding bearing 0 Bearing housing Bearing bracket 7 Column pipe 0 Motor 6, 6 Coupling complete KEPL KEPL with intermediate bearing 7
Customer specific special executions KEPL with control switch and level electrodes KEPL with sole plate KEP with float switch with guide rod
Edition 0/07 Specifications subject to change without notice