IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

Similar documents
IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO81227W/V2

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

TEST REPORT For Company:

MEASUREMENT AND TEST REPORT

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

LIGHT EFFICIENT DESIGN, LLC

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

LIGHT EFFICIENT DESIGN

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Report of Test LLIA A-R02*

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

Report of Test LLIA A

Report of Test LLIA A-R01*

Report of Test LLIA A

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79-08

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LLIA A-R02*

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Calibration Due Date Chroma Programmable AC Source 61604

Report of Test LLIA A

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report of Test LLIA A

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

NVLAP LAB CODE:

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

T8 4ft 5000K EazyLux EZ8450D7R07

NVLAP LAB CODE:

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Report of Test LLIA A

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Lighting Sciences

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description:

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

IESNA LM79: 2008 Photometric Test Report

Report of Test LLIA A

Transcription:

IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/840K-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution Test Engineer: Daniel Duan Report Number: RSZ150416507-10A1 Test Date: 2015-04-25 to 2015-04-28 Report Date: 2015-05-25 Reviewed By: Prepared By: Test Facility: Jeanne Han/Safety Manager Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0. STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

1. Product Description General Information: Two samples were received on 2015-04-16. One was tested in integrating sphere and the other was tested in goniophotometer. Model Tested: Manufacturer: Product Designation: Burning Time Before Test: LED11WA19/300/840K-DIM-G5 EiKO Global, LLC Omnidirctional LED Lamp 0 hour(for New Products) Rated Values: Rated Voltage/Frequency: Rated Power: Nominal CCT: AC 120V 60Hz 11W 4000K 2. Standards Used IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits Related Power Quality Requirements for Lighting 3. Description of Test Equipment Device Manufacture Model No Serial No Test Range Calibration Calibration date due date Integrating Sphere SENSING N/A N/A 1.5meter 2015-03-05 2016-03-05 Power Meter SENSING UI2008 908735 10.0-600.0V 2015-03-05 2016-03-05 Spectral photometer SENSING SPR3000 s0902024 350nm 800nm 2015-03-16 2016-03-16 AC Power Supply ALL Power APW- 105N 970663 0V-300V 50-400Hz 2015-03-05 2016-03-05 Standard Light Source EVERFINE D204 LSD090808 N/A 2014-08-05 2015-08-05 Thermal Meter SENSING N/A N/A 20~30 2015-03-05 2016-03-05 DC Power Supply ITECH IT6154 AC Power Supply EVERFINE VPS1060 PWM 0061 0417 6471 0010 19 0~32V 2015-03-05 2016-03-05 1101006 0-150V 0-300V 2015-03-12 2016-03-12 DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-05 Power Meter YOKOGAWA WT-210 91KB35700 Goniophotometer EVERFINE GO- R5000 15/30/60/150/300/600 2015-03-05 2016-03-05 V YG108492N10120001 1600mm,3000W/10A 2015-03-04 2016-03-04 Thermal Meter Victor VC230 EE091 0~40 0~90% 2013-04-01 2016-03-31 Standard Light Source EVERFINE D908 1012004 N/A 2014-07-31 2015-07-31 Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). Report No. RSZ150416507-10A1 Page 2 of 12 The NVLAP Lab Code is 200707-0.

4. Test Method Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25 C±1 C during measurement. And relative humidity is less than 65%. Integrating Sphere System The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. 4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the light output (luminous flux) measurements is U=1.60% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.3(K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Goniophotometer System The goniophotometer system is calibrated by standard light source before measurement. Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the luminous intensity is U=2.82% (K=2), at the 95% confidence level. Report No. RSZ150416507-10A1 Page 3 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result [Integrating Sphere System] Total operating time for integrating sphere test: 1.0 hours Test orientation: Base up Electrical Measurement Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor 120.0 60.0 0.097 10.5 0.895 Photometric Measurement Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/w) CCT (K) Duv 1181.745 3.616 112.547 4121 1.88E-03 Chromaticity Coordinate x y u v u' v' 0.3765 0.3782 0.2219 0.3344 0.2219 0.5016 Color Rendering Index Ra 84.7 R1 R2 R3 R4 83 92 96 82 R5 R6 R7 R8 83 88 87 67 R9 R10 R11 R12 17 80 80 63 R13 R14 R15 86 98 78 Report No. RSZ150416507-10A1 Page 4 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution 1.2 1.0 0.8 0.6 0.4 0.2 0.0 380 440 500 560 620 680 740 800 nm mw nm mw nm mw nm mw nm mw 380 1.421E-03 465 6.640E-02 550 8.132E-02 635 7.007E-02 720 8.302E-03 385 7.711E-04 470 5.426E-02 555 8.392E-02 640 6.442E-02 725 7.286E-03 390 5.750E-04 475 4.458E-02 560 8.631E-02 645 5.863E-02 730 6.396E-03 395 4.230E-04 480 3.855E-02 565 8.866E-02 650 5.299E-02 735 5.605E-03 400 3.414E-04 485 3.877E-02 570 9.089E-02 655 4.745E-02 740 5.023E-03 405 3.719E-04 490 4.197E-02 575 9.284E-02 660 4.227E-02 745 4.361E-03 410 6.404E-04 495 4.649E-02 580 9.461E-02 665 3.755E-02 750 3.825E-03 415 1.489E-03 500 5.153E-02 585 9.605E-02 670 3.320E-02 755 3.585E-03 420 3.314E-03 505 5.633E-02 590 9.691E-02 675 2.914E-02 760 3.232E-03 425 6.777E-03 510 6.028E-02 595 9.732E-02 680 2.546E-02 765 2.910E-03 430 1.267E-02 515 6.330E-02 600 9.666E-02 685 2.223E-02 770 2.698E-03 435 2.207E-02 520 6.607E-02 605 9.504E-02 690 1.941E-02 775 2.470E-03 440 3.621E-02 525 6.842E-02 610 9.279E-02 695 1.676E-02 780 2.391E-03 445 5.886E-02 530 7.094E-02 615 8.986E-02 700 1.465E-02 785 2.218E-03 450 9.025E-02 535 7.325E-02 620 8.566E-02 705 1.259E-02 790 2.114E-03 455 1.069E-01 540 7.594E-02 625 8.076E-02 710 1.096E-02 795 2.101E-03 460 8.942E-02 545 7.876E-02 630 7.536E-02 715 9.455E-03 800 1.982E-03 Report No. RSZ150416507-10A1 Page 5 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 7-Step & 4-Step Chromaticity Quadrangles 0.45 0.40 0.35 0.30 0.30 0.35 0.40 0.45 0.50 sample 7-STEP 2700K 7-STEP 3000K 7-STEP 3500K 7-STEP 4000K 7-STEP 4500K 7-STEP 5000K 7-STEP 5700K 7-STEP 6500K 4-STEP 2700K 4-STEP 3000K 4-STEP 3500K 4-STEP 4000K 4-STEP 5000K 4-STEP 6500K Report No. RSZ150416507-10A1 Page 6 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System] Total operating time for luminous intensity distribution: 1.0 hours Test orientation: Base up Electrical Measurement Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor 120.0 60.0 0.0967 10.42 0.8982 Photometric Measurement Luminous Flux (lm) Efficacy (lm/w) CBCP (cd) S/MH (C0/180) S/MH (C90/270) 1210.27 116.10 122 1.77 1.78 Luminous Intensity Distribution C0/180 C45/225 C90/270 C135/315 AVG. Beam Angle (50% Imax): 275.7 275.5 275.7 275.8 275.68 Field Angle (10% Imax): 347.8 347.4 347.7 347.2 347.53 Report No. RSZ150416507-10A1 Page 7 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 0 22.5 45 67.5 90 112.5 135 157.5 0.0 95 95 95 95 95 95 95 95 5.0 95 96 96 96 96 96 96 96 10.0 96 97 97 97 97 97 97 97 15.0 98 98 98 98 99 99 99 99 20.0 100 100 101 101 101 101 101 101 25.0 103 103 103 104 104 104 104 104 30.0 106 106 106 107 107 107 108 107 35.0 109 109 109 110 110 111 111 110 40.0 112 112 112 113 113 114 114 113 45.0 115 115 115 115 116 117 116 116 50.0 117 117 117 118 118 119 119 118 55.0 119 119 119 119 120 121 120 119 60.0 120 120 120 120 121 122 121 120 65.0 121 121 120 121 122 122 121 120 70.0 121 121 120 120 121 122 121 120 75.0 120 120 119 119 120 121 120 118 80.0 118 119 118 118 119 119 118 117 85.0 116 116 116 116 117 117 115 114 90.0 113 113 113 113 114 114 112 111 95.0 110 110 109 109 110 110 109 107 100.0 106 106 105 105 106 106 104 103 105.0 101 101 101 100 101 101 99 98 110.0 96 96 96 95 96 96 94 93 115.0 91 91 90 90 90 90 89 87 120.0 85 85 84 84 84 84 83 82 125.0 79 79 78 78 78 78 77 75 130.0 72 73 72 72 72 72 70 69 135.0 66 66 66 66 66 65 64 63 140.0 60 60 59 59 59 59 58 57 145.0 53 53 53 53 53 52 51 51 150.0 47 47 47 47 47 46 45 45 155.0 41 42 42 41 41 41 40 39 160.0 36 36 36 36 36 35 34 34 165.0 31 31 31 31 30 29 29 28 170.0 24 24 24 23 23 22 21 20 175.0 12 12 11 11 11 9 7 5 180.0 0 0 0 0 0 0 0 0 Report No. RSZ150416507-10A1 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) γ C Bay Area Compliance Laboratories Corp. (Shenzhen) 180 202.5 225 247.5 270 292.5 315 337.5 0.0 95 95 95 95 95 95 95 95 5.0 96 96 96 96 96 96 96 96 10.0 97 97 97 97 97 97 97 97 15.0 99 99 99 98 98 98 98 98 20.0 101 101 101 101 101 101 101 100 25.0 104 104 104 104 103 103 103 103 30.0 107 107 107 106 106 107 106 106 35.0 110 110 109 109 110 110 110 109 40.0 113 112 112 112 112 113 113 112 45.0 115 115 114 114 115 115 115 115 50.0 117 117 116 116 117 117 117 117 55.0 119 118 117 117 118 119 119 119 60.0 120 119 118 118 119 120 120 120 65.0 120 119 118 118 119 120 120 120 70.0 119 119 118 118 119 120 120 120 75.0 118 117 116 116 118 119 119 119 80.0 116 116 114 115 116 117 117 117 85.0 114 113 112 112 114 115 115 115 90.0 111 110 109 109 111 112 112 112 95.0 107 106 105 105 107 108 108 109 100.0 102 102 101 101 103 104 104 105 105.0 98 97 96 97 98 100 100 100 110.0 92 92 91 91 93 94 95 95 115.0 87 86 86 86 88 89 89 89 120.0 81 80 80 80 82 83 83 83 125.0 75 74 74 74 76 77 77 77 130.0 69 68 68 68 70 71 71 71 135.0 62 62 61 62 63 64 65 65 140.0 56 56 55 56 57 58 58 59 145.0 50 50 49 50 51 52 52 52 150.0 44 44 44 44 45 46 46 46 155.0 38 38 38 38 39 40 40 41 160.0 33 33 33 33 34 34 35 35 165.0 27 27 27 28 28 29 29 30 170.0 19 19 19 19 20 20 22 23 175.0 1 1 2 5 6 6 6 9 180.0 0 0 0 0 0 0 0 0 Report No. RSZ150416507-10A1 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure Angle: 90.00. Flux out: 196.5 lm. Height (m) Diameter (cm) E avg (lx) E max (lx) 0.5 100.0 250.2 382.7 1.0 200.0 62.6 95.7 1.5 300.0 27.8 42.5 2.0 400.0 15.6 23.9 2.5 500.0 10.0 15.3 3.0 600.0 7.0 10.6 3.5 700.0 5.1 7.8 4.0 800.0 3.9 6.0 4.5 900.0 3.1 4.7 5.0 1000.0 2.5 3.8 Report No. RSZ150416507-10A1 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement Deg Flux (lm) % Deg Flux (lm) % 0-5 2.3 0.19 0-5 2.3 0.19 5-10 6.9 0.57 0-10 9.2 0.76 10-15 11.6 0.95 0-15 20.7 1.71 15-20 16.4 1.36 0-20 37.2 3.07 20-25 21.4 1.77 0-25 58.6 4.84 25-30 26.6 2.20 0-30 85.2 7.04 30-35 31.9 2.64 0-35 117.1 9.68 35-40 37.1 3.07 0-40 154.3 12.75 40-45 42.2 3.49 0-45 196.5 16.24 45-50 47.0 3.88 0-50 243.5 20.12 50-55 51.4 4.25 0-55 294.9 24.37 55-60 55.2 4.56 0-60 350.1 28.93 60-65 58.4 4.82 0-65 408.5 33.75 65-70 60.8 5.03 0-70 469.3 38.78 70-75 62.4 5.15 0-75 531.7 43.93 75-80 63.1 5.22 0-80 594.8 49.15 80-85 63.0 5.21 0-85 657.9 54.36 85-90 62.1 5.12 0-90 719.9 59.48 90-95 60.2 4.98 0-95 780.1 64.46 95-100 57.7 4.77 0-100 837.8 69.23 100-105 54.4 4.49 0-105 892.2 73.72 105-110 50.6 4.18 0-110 942.8 77.90 110-115 46.3 3.83 0-115 989.1 81.73 115-120 41.7 3.44 0-120 1030.8 85.17 120-125 36.9 3.04 0-125 1067.6 88.21 125-130 32.0 2.65 0-130 1099.6 90.86 130-135 27.2 2.25 0-135 1126.8 93.11 135-140 22.6 1.86 0-140 1149.4 94.97 140-145 18.3 1.51 0-145 1167.7 96.48 145-150 14.3 1.19 0-150 1182.0 97.67 150-155 10.9 0.89 0-155 1192.9 98.56 155-160 7.8 0.65 0-160 1200.7 99.21 160-165 5.3 0.44 0-165 1206.0 99.65 165-170 3.1 0.25 0-170 1209.0 99.90 170-175 1.2 0.09 0-175 1210.2 99.99 175-180 0.1 0.01 0-180 1210.3 100.00 Report No. RSZ150416507-10A1 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6. Product Photo LED11WA19/300/840K-DIM-G5 LED11WA19/300/840K-DIM-G5 ***********END OF REPORT*********** Report No. RSZ150416507-10A1 Page 12 of 12 The NVLAP Lab Code is 200707-0.