Model VSI-I & VSI-II Positive Pressure Venting Systems

Similar documents
SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

venting systems for high efficiency appliances series

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Models PS/IPS. Stainless Steel Double Wall Positive Pressure Piping Systems FEATURES CATALOG

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.

Model N. Stainless Steel Double Wall Positive Pressure Venting Systems. Special Gas Vent Applications COMMERCIAL AND INDUSTRIAL VENTING

SIGRAM FLUE SYSTEMS LTD

Model ND-2 Specification

Tubular Centrifugal Fans

INSTALLATION AND MAINTENANCE INSTRUCTIONS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

Versatility in Applications

Model RIS ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24"

Modular Double-Wall Positive Pressure Chimney Boiler Breeching & Stack and Engine Exhaust Grease Duct

MODEL PA. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

RECEIVING AND INSPECTION

Table of Contents WARRANTY...3 APPLICATION...4 MECHANICAL...5 Joint Sealant...5 Grease Duct Standard Connection...6 Collar and Adjustable Duct

Gas Venting Systems residential industrial commercial

MODEL P1. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

MODEL P4. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

MODEL P2A. Chimney and Exhaust Systems. Underwriters c. Laboratories Inc. LISTED

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

INSTRUCTIONS FOR MAINTENANCE AND USE KITCHEN EXTRACTOR HOOD ZRW 50/60

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Roof Upblast and Sidewall Exhaust

Stovepipe DVL. DuraBlack. Double-wall interior stovepipe for connecting woodstoves to chimney. ULC S641.

Direct or Non-Direct Venting

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

Roof Upblast and Sidewall Exhaust

XIII. Repair Parts 106

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Specifications. UL 1777 and ULC S641 System. Combustion Air System-DuraTech and DuraPlus HTC

KVL-P with Plate Shelf

Low Silhouette Power Roof Ventilator Propeller

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

DuraChimney II. Air-cooled chimney system for masonry fireplaces. UL 103.

easy duct - an investement in your future

Series. Chimney System for High Efficiency Appliances. Underwriters c. Laboratories Inc. LISTED

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Stainless Steel Chimneys Ducts and Fittings for Air Conditioning & Ventilation

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT

Scotseal TF Hubcaps. Heavy duty durability and dependability from the wheel-end experts at SKF.

NECO Pumping Systems

ExtractAire. Grease Filters for Commercial Kitchen Ventilation Hoods. Baffle. High Velocity Cartridge (HVC)

mechanical coupling system

DVL & DuraBlack. Simpson Dura-Vent Engineered Excellence

Scotseal TF Hubcaps. Heavy duty durability and dependability from the wheel-end experts at SKF.

Scotseal TF Hubcaps. Heavy duty durability and dependability from the wheel-end experts at SKF.

Scotseal TF numerical list

Inline Fans [ 14 ] * UL is optional and must be specified.

KH E, KH E

SECTION HVAC POWER VENTILATORS

3) Storage at construction sites for refueling construction equipment; or. 4) Storage at airports as addressed in Section of this Part.

National Enduralube Bearings

SUBMITTAL COVER SHEET

Channel Cable Tray - Accessories & Fittings

venting systems for high efficiency appliances series

University of Delaware

Installation, Operation and Maintenance Manual

Busway Construction. Bus Bars

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Installation Instructions

IMMERSION FIRED HOT WATER BOILER

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

Manufacturing Facilities. Sheet Metal Connectors, Inc. is proud to be a member or affiliated with the following associations;

Commercial Hopper Tanks (CHT)

Centrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators

PRODUCT INDEX PRODUCT INDEX. Item Page Item Page Item Page

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

We make dampers easy for you!

SECTION DUCTWORK ACCESSORIES

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

MBN Multistage Ring Section Pumps

BREEZE Hi-Torque Liner Clamps

IDEAL STEEL HYBRID GEAR HEAD STOVES OWNER S MANUAL MODEL 210 BY WOODSTOCK SOAPSTONE COMPANY

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

CASING SPACERS DESIGNED FOR WATER, SEWER, OIL & GAS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

T&B Cable Tray. In this section...

Wall Mount Chimney Style. Island Mount Chimney Style. Wall Mount Professional Style. Insert Mount Professional Style

Completing Your Fume Removal System

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

Universal APU2 Pump Automotive Paint Series

Chempump. G Series. Canned Motor Pumps

Overall dimensions (WxHxD in inches): 48 x 18 x x 18 x x 18 x 25

Hose & Hose Clamps. EPDM Rubber Pressure Hose. Hose & Clamps. EPDM Rubber Hose

Direct Vent Top Exit Vertical Flue Kit

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Saino Fire SlidingDoors. Pharmaceutical Doors. Industrial Sliding Doors

EASY DUCT - AN INVESTMENT IN YOUR FUTURE

Transcription:

C O M M E R C I A L A N D I N D U S T R I A L V E N T I N G Model VSI-I & VSI-II Positive Pressure Venting Systems Ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines and kitchen appliances Your choice of single-wall or double-wall (air-insulated) construction

VSI-I & VSI-II Venting Increases usable floor space. Offers the lowest clearance to combustibles in the industry, as listed by UL/ULC. Many Applications AMPCO s sealed exhaust systems are ideal for discharging exhaust gases and fumes from boilers, heaters, ovens, engines, turbines, and kitchen appliances. AMPCO chimneys are UL/ULClisted and will accommodate flue gases at temperatures not exceeding 1800 F intermittent operation and up to 1400 F continuous operation. Grease duct applications are 500 F continuous. Lightweight, interchangeable and easy to install AMPCO insulated components are so light and easy to install that 1 or 2 people can easily assemble them without special equipment. No welding or on-site fabrication is required. Components are interchangeable, allowing complex systems to be assembled from standard elements. This means modifications, additions or repairs can be made quickly and economically. Furthermore, AMPCO furnishes detailed drawings and easy-to-follow instructions. This reduces installation time and assures a safe installation. Full Product Line VSI-I Single Wall AMPCO chimneys are available in diameters from 6" through 48". Fittings include: Variable lengths 90 manifold tees 45 lateral tees Wyes 15, 30, 45, and 90 elbows Support pieces Termination components Adapters Expansion joints Sealants VSI-II Double Wall AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL 60106 TEL: (630) 595-7320 FAX: (630) 766-5259 Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances. 6

VSI-I & VSI-II Venting Professional Engineering and Technical Support AMPCO engineers have many years of experience. This is why they can help you design a complete venting system, whether your system is very simple or complex. All you need to furnish is the basic information. (See Design Checklist on page 3.) We ll perform all sizing calculations, provide submittal CAD drawings, and furnish a bill of materials for the total system designed to your specifications. Chances are the AMPCO system can be installed at far less cost than conventional on-site construction methods. Labor savings can be as much as 50% or more! When you work with AMPCO, you deal with a company that is known for quick product delivery, quality components, and excellent customer service. That s not just a promise. It s our guarantee! Quality Construction and 10-Year Factory Warranty AMPCO insulated venting is built to last for years. Inner walls are constructed of 304 or optional 316 stainless steel. Type 316 stainless is recommended for high sulphur fuels and/or corrosive environments. Type 304 stainless steel is suitable for gas, number two diesel grades of fuel, oil or wood. All pipes and fittings are continuous seamwelded and pressure tight. Wide-end flanges provide a strong, virtually leak-proof joint. Containment and closure bands resist slippage from vibration or thermal expansion because they are deeply flanged and channeled. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL 60106 TEL: (630) TEL: 595-7320 (630) 766-5240 FAX: (630) FAX: 766-5259 (630) 595-7868 7 Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.

Model VSI - Assembly Many Exclusive Features Fast, on site assembly. No need for welding or special tools! AMPCO insulated elements simplify on-site installation. Components are joined together with a Containment Band that is fitted over the butted flanges of the adjoining inner wall and bolted in place. No welding is necessary. A Closure Band is then fitted over the outer wall and bolted in place. Hangers, Wall Supports, and other accessories are just as easy to install. 1. 2. 3. 4. 5. Apply a continuous bead of the proper sealant to one of the flanges to be joined. Join the two flanged ends of the pipe sections together. Fill the channel of the flanged band with proper sealant. Install flange band around flanges. Secure the outer casing with the Closure Band. Check to make sure pieces are secure and air tight. AMPCO s patented spacers, a tighter fit and quieter operation AMPCO s patented spacer separates the walls of the AMPCO positive pressure insulated components. Spacers strengthen stability and provide a stronger base for the closure band. This results in extra strength, tighter fit, and quieter operation. AMPCO s sealants, a virtually leak-free joint AMPCO s VS 600 sealant is used for outer wall weather-proofing and for particle containment only. AMPCO s VS 2000 sealant is for alltemperature inner wall joint requirements. AMPCO s VS 600 RED is used for grease duct inner wall joints. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL 60106 TEL: (630) 595-7320 FAX: (630) 766-5259 Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances. 8

Model VSI Product Information Chart Commercial/Industrial Air Distribution Systems MODEL Description Applications VSI-I Single-wall stainless steel Air/product containment Grease duct Double-wall air insulated VSI-II Boiler and chimney systems, engine/turbine exhausts, grease/oven exhausts, air/particle containment Fuel Types Exhaust Exhaust Temperature Listings Diameters Materials Insulation Clearances to Combustibles (unenclosed chimney) LP; natural gas; #2, #4*, #5*, or #6* fuel oil; wood; coal*; grease vapors; caustic fumes*; particles (*recommend 316 stainless steel) Grease Duct 500 F Inner: Standard 304SS.035" 6" to 36" (optional.035" 20 ga 316SS available).048" 18 ga 304SS 38" to 48" Outer: N/A N/A Air and particle containment = ½" Grease duct = 18" Positive, neutral or negative 1000 F continuous, 1400 F intermittent 1400 F continuous, 1800 F intermittent Grease Duct 500 F continuous, 2000 F intermittent 6" through 48" Inner:.035" 20 ga 304SS standard 6" to 36" (optional.035" 20 ga 316SS available).048" 18 ga 304SS 38" to 48" Outer:.025" 24 ga aluminum-coated steel 6" to 24".034" 20 ga aluminum-coated steel 26" to 48" (optional 304 or 316SS available) 1" air Clearances to Noncombustible ½" or distances required to allow for proper installation and maintenance AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL 60106 TEL: (630) TEL: 595-7320 (630) 766-5240 FAX: (630) FAX: 766-5259 (630) 595-7868 9 Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.

Model VSI Installations Typical boiler stack installation using VSI Ability to reduce clearances to one-half inch. Greatly reduces clearance requirements of welded steel and those of competitive products, while providing a safer environment. Saves on cooling bills by reducing appliance-radiated exhaust heat. Agency-listed for temperatures up to 1000 F continuous, 1400 F intermittent and 1400 F continuous, 1800 F intermittent. Interchangeable with all other AMPCO positive pressure components. Material or air-insulated components can be integrated to achieve desired results within a single exhaust system. Typical diesel engine exhaust installation using VSI Reduced skin temperatures mean less risk of personal injury. Reduced skin temperatures result in reduced clearances to combustibles, the best in the industry. Provides minimum exhaust back pressure for maximum performance. AMPCO will design, at no charge, an exhaust system that will allow for thermal expansion, increasing engine and exhaust system life. Agency-listed for temperatures up to 1000 F continuous, 1400 F intermittent and 1400 F continuous, 1800 F intermittent. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL 60106 TEL: (630) 595-7320 FAX: (630) 766-5259 Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances. 10

Model VSI Installations Typical grease duct installation using a VSI venting system Reduces risk of fires by providing a tough insulated barrier. Reduced clearances mean more available space. Allows for thermal expansion under severe conditions. Capabilities for automatic wash-down and fire detection/prevention systems. Grease traps control grease-laden vapors, which reduces risk of grease fires. Complete agency certification for exhaust temperatures 500 F continuous and 2000 F intermittent. Interchangeable with other insulated and noninsulated AMPCO components. Hood Hood The Advantages of VSI-I & VSI-II Venting 1. Reduces skin temperature for a safer environment. 2. Saves on cooling bills by reducing ambient temperature in kitchens and in engine and boiler rooms. 3. Interchangeable with all AMPCO stack components. Use insulated sections only as required. 4. Increases usable floor space and reduces clearance to combustible and noncombustible material. 5. Reliable; UL- and/or ULC-listed. AMPCO 484 N. THOMAS DRIVE BENSENVILLE, IL 60106 TEL: (630) TEL: 595-7320 (630) 766-5240 FAX: (630) FAX: 766-5259 (630) 595-7868 11 Copyright, October, 2007, Commercial Products Group of Hart & Cooley, Inc. All Rights Reserved. All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.