Architect Luna/Prisma/Circum Service & maintenance. lindab we simplify construction

Similar documents
lindab we simplify construction Plafond Service & maintenance

Use. Installation. Key figures. Worth noting. linx industries chilled beams

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

Halton Rex 600 RE6 - Adaptable active chilled beam

LindabPodium. Supply air beam. lindab we simplify construction

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

Shut-off valves SVA-DH, SVA-DL

Instructions for Installing the Vi p e r Si g n a l Ma s t e r

SEMI RIGID THE PROFESSIONALS CHOICE

PROMAX INSTRUCTION MANUAL

KWF Water Wash Canopy with Supply Air

KLIMA Active Chilled Beams

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

Chilled beam for ceiling installation

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Machine Deals. The Complete 3M System: The Right Machine + The Right Abrasive + The Right Accessory = Outstanding Result

Swegon PACIFIC. Integrated climate beam

Measuring probe For ventilation and air-conditioning Model A2G-FM

Instructions for Installing the Vi p e r Si g n a l Ma s t e r with Brake Module

Highline 260i EC Waterside Fan Coil Unit

Variable Air Volume Dampers

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Complete HVAC Capability

CornerAir. CornerAir. Active chilled beam

Tube Axial Inline Fans

Company Standard Mounting Instructions for Type Valves with Type AT Actuator

ATZAF DOUBLE INLET AIRFOIL BLADEDBACKWARD CURVED CENTRIFUGAL FANS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

NAPAF - NAPBC HIGH PERFORMANCE AIRFOIL NAPAF AND BACKWARD CURVED NAPBC PLENUM FANS. 1 a Edition - subject to future integrations

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

KVI Kitchen Canopy With Capture Air

Paraffin Block Trimmer Quick Trim UPBT 1011

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Total comfort control

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

ROL NOZZLE DUCT ROL-S ADJUSTMENT AND SILENCER UNIT

After installing the HEPA filters the discharge air should be monitored to ensure proper filtering efficiency. HEPA Filters

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

INSTALLATION & OWNER S MANUAL

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

series CEVH Smoke Evacuation Damper

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

PLAFOND B. Connection cover. lindab we simplify construction

LØV-R. Orion-Opus. Square supply diffuser

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Warning. Document ref: A October 2015

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

BRC

INSTALLATION & OWNER S MANUAL

GUIDE TO CLEANING grease extraction systems

Safety and Installation Instructions For Fluitecnik PV Modules

series FSD-FLD Fire and smoke dampers UL Approval

GL Ludemann Y-Strainers

INSTALLATION & OWNER S MANUAL

HAWLE-AIR RELEASE VALVES

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

FIVC. Static Balancing Valve. Technical data. Dimensions

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

Alfa Laval Toftejorg Rotary Spray Heads MultiMidget & MultiMagnum

High Performance Axial Fans

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

AXIAL FANS Catalogue CN0050C01 May 2008

SERVICE MANUAL ULTIMATE 200

Sniper EFI Fuel Kits P/N 526-5/526-8 (20 ft. hose) & (40 ft. hose)

Apartment ventilation

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

SK-4. Anleitung. Manual. Mode d emploi. Handleiding. Art.-Nr

ADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

Square supply diffuser

MODULAR AIR HANDLING UNITS GAH SERIES

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Zest Iris Duct Dampers

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

VAV TERMINAL UNITS. VVD VAV Diffusers

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

2-Port and 3-Port Zone Valves PN 16

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

PROHOOD AIR CAPTURE HOOD MODEL PH731

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

VAV controller. TROX Auranor Norge AS. Telephone Fax

Midea Air Handling Unit

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

Swegon PACIFIC. Integrated climate beam

MAKING MODERN LIVING POSSIBLE. Danfoss Air Flex Catalogue DANFOSS HEATING

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Automatic balancing valves ASV-PV DN (3rd gen.)

Typical Applications. Horizontal Installation

t EVAPORATOR PRESSURE REGULATING VALVES

ICAN INTELLIGENT AIR FLOW DEVICE

MAKING MODERN LIVING POSSIBLE. Danfoss Air Flex Catalogue DANFOSS HEATING

Transcription:

Service & maintenance lindab we simplify construction

1.0 Installation 1.1 Product description Lindab s supply air beam Architect provides great freedom of choice in design. A large number of predefined design solutions can be easily applied, in terms of technology, to create customized design solutions with great flexibility, but without affecting the function and performance. One of the advantages is that planning can be done without having to decide on a design. It is also simple to renew the design, if necessary in the future. 1.2 Handling The beam must be handled with care, ensuring that the beam does not sustain dents, scratches or bends during installation. Always seek to lift the beam at multiple points. Do not lift in pipes Do not lift in edges Each beam is equipped with protective film to avoid any damage during transport and handling at building site. The film needs to be removed before commissioning the products. 1.3 Mounting instruction Please visit www.lindqst.com Select Documentation Finder Select Architect Select Mounting - Luna, Prisma, Circum 1.4 Air connection installation The primary air supply should be connected with instructions from a ventilation specialist. Lindab s chilled beams can beneficially be used together with Lindab s Safe duct systems. 1.5 Connection description water Flow indication arrows are shown on the inlet and return pipes in order to assist the installer. If the beam has been ordered with integrated valves, a special direction of the flow must be upheld to ensure correct flow through the thermostatic valve. If the beam has been delivered without integrated valves, the flow can be reversed, depending on the location of the retrofitted valve. Please note the flow direction indicator on the valve to insure correct installation in relation to the desired flow. 2 We reserve the right to make changes

1.5.1 Push-on fittings Please ensure that all pipes and fittings are undamaged, as even small dents and scratches potentially pose a risk of leakage in the system. Always remember to do a pressure test after assembly of the pipe work. Both flow and return pipe is covered by a plastic or rubber protection cover, which should be removed before installation. After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end. Crocked or in other ways imperfect pipe ends will result in leaks. Deburr the pipe on the inside and the outside, using a deburring tool before installation Mount a push-on fitting to the pipe. Make sure to press the fitting all the way onto the pipe. Consult the installation guide for the specific fitting for further details on proper installation. Push-on fitting We reserve the right to make changes 3

Push-on valve Notice! The connection pipes are internally soft-welded why it s not allowed to solder the beam to the pipes. 1.5.2 Compression fitting Please ensure that all pipes and fittings are undamaged, as even small dents and scratches potentially pose a risk of leakage in the system. Always remember to do a pressure test after assembly of the pipe work. While mounting a compression fitting, the pipe will be exposed to a big amount of force, creating a risk of crushing the pipe. To ensure that the pipe won t be crushed when mounting the compression fitting, a copper insert should be inserted into the pipe. Both flow and return pipe is covered by a plastic or rubber protection cover during transport, which must be removed before installation. After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end. Crocked or in other ways imperfect pipe ends will result in leaks. Deburr the pipe on the inside and the outside, using a deburring tool before installation 4 We reserve the right to make changes

The copper insert should be placed inside the pipe on the beam. Always support the copper pipe coil when inserting the copper insert into position. Mount a compression coupling and/or a valve to the pipe. Don t stress the nut too much, since this may crush the pipe. Notice! The connection pipes are internally soft-welded why it s not allowed to solder the beam to the pipes. 1.5.3 Flex hoses Our flexible hoses can be used with both compression and Tectite fitting. We recommend using Tectite fittings, for easier and faster mounting. Please ensure that all pipes and fittings are undamaged, as even small dents and scratches potentially pose a risk of leakage in the system. Always remember to do a pressure test after assembly of the pipe work. Both flow and return pipe is covered by a plastic or rubber protection cover, which should be removed before installation. We reserve the right to make changes 5

After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end. Crocked or in other ways imperfect pipe ends will result in leaks. Deburr the pipe on the inside and the outside, using a deburring tool before installation Mount a push-on fitting to the pipe. Make sure to press the fitting all the way onto the pipe. After mounting the push-on fitting, mount the flexible hose. Make sure that the flexible hose is pushed fully into the fitting. Consult the installation guide for the specific fitting for further details on proper installation. Push-on fitting Push-on valve Notice! The connection pipes are internally soft-welded why it s not allowed to solder the beam to the pipes. 6 We reserve the right to make changes

2.0 Commissioning 2.1 Product labeling Fig.1: Label location exterior (On plastic wrapping) Fig.2: Label location interior (Air connection end) On the label you ll find: Order: Order identification number. Pos: Order position. Product: Product configuration. Project: Project name. Mark: Marking noted on order. Nozzles: Number of nozzles. Plugs: Number of plugged nozzles. Product ID: Product number. Sign: To be signed when checked and commissioned on site. 2.2 Measure air pressure and calculating the airflow. Before calculating the airflow, the static nozzle pressure must first be measured. The static nozzle pressure is the air pressure available at the nozzles. 2.2.1 Measure the static nozzle pressure. To measure the air pressure, a manometer, analog or digital (such as the Lindab PC410) will be needed. Insert the measuring tube onto the specialized measuring nozzle Read off the static nozzle pressure from the manometer We reserve the right to make changes 7

2.2.2 Calculating the airflow After measuring the static nozzle pressure, read the setting of the four pins in the corners to find the mean value of the pins. Locate the diagram on the faceplate or see diagram 1-2, and use the static nozzle pressure and the mean value of the pins to find the current airflow. [Pa] 150 Architect 1.2m L 2.0m Position Position of JetCone adjustment pins 0 1 2 3 4 5 6 7 8 9 100 90 80 70 60 50 40 5 6 7 8 9 10 15 20 25 30 40 50 [l/s] Diagram 1 [Pa] 150 Architect 2.0m < L 3.0m Position of JetCone adjustment pins 0 1 2 3 4 5 6 7 8 9 100 90 80 70 60 50 40 7 8 9 10 15 20 25 30 40 50 60 70 80 [l/s] Diagram 2 8 We reserve the right to make changes

16 Architect 2.3 Changing the airflow 30 Measure the static nozzle pressure Locate the air pressure/airflow diagram on the faceplate, or see diagram 1-2. Find the mean value of the four pins to reach the desired airflow, in the diagram on the faceplate. Use the static nozzle pressure and the desired airflow to find the mean value of the four pins. Adjust the four pins in the corners, so the mean value of the pins will correspond with the mean value found in the diagram. Example: Pin setting: 6+6+8+8 = 28 / 4 = mean value 7. 2.4 Changing the air pattern Align the Air deflector in the desired position. Air deflector 36 18 0 18 36 The faceplate include seperate adjustable deflectors. Bundpladen har seperate justerbare deflektore. Bottenplattan har separata justerbara luftriktare. Etulevyssa on erillista saadettavaa ohjainta. Die Frontplatte enthält separate, einstellbare Luftlenkelemente. La piastra include file di deflettori regolabili. La façade comprend déflecteurs ajustables séparément. 36 18 0 18 36 We reserve the right to make changes 9

3.0 Maintenance The interval of cleaning depends on the indoor environment where the beam is placed. Under optimal conditions the Architect beams only need cleaning every 5 years. 3.1 Cleaning instructions Remove the faceplate. Clean underneath the battery with a vacuum cleaner and a piece of wet cloth. Demount the inspection hatch in the opposite end of the air connection, in a turn and pull motion. Clean the inside of the beam with a vacuum cleaner and a piece of wet cloth. Only use lukewarm water and a mild detergent. 10 We reserve the right to make changes

4.0 Product and system specification 4.1 Material data Architect Luna, Prisma, Circum Weight, kg/m 11 Water content, cooling, l/m 0.50 Water content, heating, l/m 0.25 Copper pipes, quality SS/EN 12449 Pressure class PN10 4.2 Environmental declaration Please visit www.lindqst.com Select Documentation Finder Select Architect Select Environmental declaration 4.3 Working and test pressure Lindab s waterborne products have been manufactured and tested according to the Pressure Equipment Directive 97/237EC. The products are classified as SEP Sound Engineering Practice. Pressure table Pressure class Max. working pressure Max. recommended dynamic pressure Max. test pressure PN10 10 bar 0.2 bar 16 bar Even though the battery of the chilled beam can withstand a very high static working pressure, we recommend a much lower dynamic working pressure, to avoid noise issues from the valves. We reserve the right to make changes 11

4.4 Water quality The water preparation and maintenance for the chilled beam water circuit should be handled by a specialist To prevent corrosion, the water circuit must be airtight The water system must also be equipped with aerators to remove any build-up air in the system. The water should be oxygen free, to prevent corrosion. The water system must be filled with potable water that complies with the EC directive 98/83/EC. ph value of water must be between approximately 6-9 ph The water velocities should not exceed 1m/s, and should be kept as close to the nominal flow as possible to minimize noise and optimize the energy yield There should be used in-line strainers to remove dirt particles from the water. If the water contains any additive inhibitor this must be appropriate to use with copper and solder. 4.5 Air quality Primary supply air should be clean and filtered before reaching the beam. 4.6 Capacity test Lindabs active chilled beams are Eurovent-certified and tested according to EN-15116. 12 We reserve the right to make changes

Support Hjælp Hjälp Tuotetuki Unterstützung Supporto UK - Here you can find product updates/mounting instructions and support telephone number/mail. www.lindab.com Right to alterations reserved. DK - Her kan du finde seneste produkt opdateringer/montagevejledninger samt support tlf. nr/mail. www.lindab.dk Ret til ændringer forbeholdes. SE - Här kan du alltid hitta senaste produktuppdateringarna/montageanvisningarna samt support tel. /e-mail. www.lindab.se Rätt till ändringar förbehålles. FI - Täältä löydät uusimmat tuotetiedot ja asennusohjeet sekä tuotetuen yhteystiedot. www.lindab.fi Oikeus muutoksiin pidätetään. DE - Hier finden Sie aktuelle Produktinformationen/ Montageanleitungen und Telefonnummer/ E-Mail-Adressen der Ansprechpartner. www.lindab.de Änderungen vorbehalten. IT - Qui potete trovare istruzioni di montaggio, informazioni sul prodotto ed un supporto tecnico qualificato Tel. 011 9952099 - e-mail: lindab@lindab.it www.lindab.it Soggetto a modifica senza obbligo di preavviso. FR - Vous trouverez les fiches produits ou de montage actualisées ainsi que les coordonnées du support téléphonique à l adresse suivante : www.lindab.fr Toutes modifications réservées. Do you have trouble finding your local contacts please go to: www.lindab.com Architect-16042015 www.lindab.com