ibusway for Data Center

Similar documents
Galaxy Receiving and Unpacking 09/

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

H- or J-Frame Main Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

Galaxy VM. Battery Breaker Box Installation 09/

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

SecoVac * Ground & Test Device

Installation Instructions For Motor Control Center (MCC) Units

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

Installation and Operation

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

AE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview

dans un panneau de distribution NQ Instruction Bulletin Boletín de instrucciones Directives d'utilisation

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

S&C Type FVR Substation Circuit Breaker

Freedom egen System End-of- Line Functional Checklist

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

POWERBUS 225 Busway and Plug-In Units

Quik-Spec Coordination Panelboard

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

Vacuum Circuit Breaker (Vehicle)

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

Installation Instructions

Installation, Operation, and Maintenance

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Altivar 58 TRX Adjustable Speed Drive Controllers in Motor Control Centers hp, 480 V or 1 50 hp, 208/240 V Class 8998

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Vacuum Circuit Breaker Type VAD-3

Galaxy Installation 08/

Model C230 Pump Controller

Owner's/Installation Manual

Symmetra PX with Maintenance Bypass

February 28 th, 2018 UPDATE: Important Product Safety Bulletin Immediate Action Required INSTRUCTIONS FOR FIELD RISK MITIGATION

Vacuum Circuit Breakers (Vehicle) Type HKR 7.5kV to 15kV. Instructions Installation Operation Maintenance SGIM-9928C

Symmetra PX kw 208 V. Installation 01/

Electrical Installation

DeZURIK TEN-POSITION LEVER MANUAL ACTUATOR

Technical Manual. DLM Module. This manual should remain with the unit.

Safety and General Information

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Effective June 2016 New Issue

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Vacuum Circuit Breakers (Vehicle)

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Single-Phase, Liquid-Filled, Compartmental-Type, Pad-Mounted Transformers Class 7230

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

IB PowlVac ITE-HK Remote Racking Device

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Installation Instructions

Effective November 2016 Supersedes February 2012 (S )

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

Symmetra PX. 250/500 kw 400/480 V Single and Parallel Installation 07/

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Installation Power Management Unit Battery Cables and Battery Harness

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/

Vacuum Circuit Breakers (Vehicle)

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Instruction and Installation Guide

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

Installation. S&C Omni-Rupter Switches Outdoor Distribution 14.4 kv and 25 kv

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

O & M Manual for the EATON Generator Ready Loadcenter

IMPORTANT SAFETY INSTRUCTIONS

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

BP-Husky Refinery Toledo, OH

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

920 Remote Control Switches

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Electrical network protection VIP30, VIP35. User s manual 12/2008

Magnum breaker remote racking device (MRR1000)

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Installation Guide Smart-UPS On-Line Replacement Battery Module APCRBC140/APCRBC140J

Electrical Safety CSA Z462 & NB Regulations

Transformer Installation, Operation, and Maintenance Manual

Energized Electrical Work

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Figure 1. Kearney Type HX cutout.

SAVE THESE INSTRUCTIONS

Transcription:

ibusway for Data Center PBPQOD Plug-In Units with 15 60 A Circuit Breakers for Use On Busway Straight Sections Class 5600 Installation S1B99523 06/2012

Hazard Categories and Special Symbols Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it. The following special messages may appear throughout this bulletin or on the equipment to warn of hazards or to call attention to information that clarifies or simplifies a procedure. The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, can result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, can result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. The safety alert symbol is not used with this signal word. NOTE: Provides additional information to clarify or simplify a procedure. Please Note Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Table of Contents Table of Contents Introduction... 5 Safety Precautions... 5 Standard Application Precautions... 5 Receiving, Handling, and Storage... 6 Receiving... 6 Handling... 6 Protection During Storage... 6 Plug-In Unit Interrupting Rating... 7 Installing the Plug-In Unit Onto the Busway... 7 Standard Application Precautions... 7 Pre-Installation Testing... 8 Installing the Plug-In Unit... 9 Removing the Plug-In Unit From the Busway... 12 Standard Application Precautions... 12 Removing/Replacing the QOU Circuit Breaker from a Plug-In Unit... 13 Removing the QOU Circuit Breaker... 13 Replacing the QOU Circuit Breaker... 14 Operation... 15 Turning the Plug-In Unit to the ON (I) and OFF (O) Positions... 15 Accessories and Replacement Parts... 15 Accessories Padlocking... 15 Standard Application Precautions... 15 General Maintenance... 16 2012 Schneider Electric All Rights Reserved 3

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 List of Figures and List of Tables 06/2012 List of Figures Figure 1: Securing the Plug-In Unit Cover... 8 Figure 2: Testing for Plug-In Unit Continuity Prior to Installation... 8 Figure 3: Inspect Plug-In Jaws... 9 Figure 4: Removing Plug-In Unit Door... 9 Figure 5: Plug-In Unit Top Flange Engagement... 9 Figure 6: Plug-In Location... 10 Figure 7: Securing the Plug-In Unit Onto the Busway... 11 Figure 8: Removing/Replacing the QOU Circuit Breaker... 14 Figure 9: Turning the Plug-In Unit to the ON (I) and OFF (O) Positions... 15 List of Tables Table 1: Plug-In Unit Rating Information... 7 Table 2: Accessories and Replacement Parts... 15 4 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Introduction Introduction This bulletin contains instructions for the handling, storage, installation, operation, and maintenance of Powerbus PBPQOD circuit breaker plug-in units rated 15 60 A and manufactured by Schneider Electric. The purchaser s engineering, installation, and operating staff supervisors should familiarize themselves with this bulletin and become acquainted with the appearance and characteristics of the equipment. Read and understand this bulletin completely before performing the installation, operation, and maintenance steps provided. For additional circuit breaker information, refer to the appropriate Square D brand circuit breaker bulletin supplied with the equipment. Safety Precautions Standard Application Precautions DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. This plug-in unit must be installed and serviced only by qualified electrical personnel. Do not install the circuit breaker type plug-in unit onto the busway without a circuit breaker installed. Use only Square D brand circuit breakers in this plug-in unit. The circuit breaker catalog prefix must match the plug-in unit prefix on the nameplate. Do not install, operate, or remove the plug-in unit with the cover open or removed. Turn off power to the busway before installing or removing the plug-in unit. Turn off power to the busway or remove the plug-in unit before opening or working inside the enclosure. Turn off the plug-in unit before opening or working inside the enclosure. Always use a properly rated voltage sensing device to confirm the plug-in unit is de-energized. Failure to follow these instructions will result in death or serious injury. 2012 Schneider Electric All Rights Reserved 5

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 Receiving, Handling, and Storage 06/2012 Receiving, Handling, and Storage Receiving Upon receipt of plug-in units, check the packing list against the equipment received to ensure the order and shipment are complete. Claims for shortages or errors must be made in writing to Schneider Electric within 60 days after delivery. Failure to give such notice will constitute unqualified acceptance and a waiver of all such claims by the purchaser. Immediately inspect the equipment for any damage which may have occurred in transit. If damage is found or suspected, file a claim with the carrier immediately and notify Schneider Electric. Delivery of equipment to a carrier at any of the Schneider Electric plants or other shipping points constitutes delivery to the purchaser regardless of freight payment and title. All risk of loss or damage passes to the purchaser at that time. For details concerning claims for equipment shortages and other errors, refer to Schneider Electric s Terms and Conditions of Sale. Handling Protection During Storage Plug-in units for use on Powerbus busway are shipped in corrugated cartons. Do not drop or perforate the cartons. Rough handling may cause damage to the electrical components contained within. Handle the plug-in units with care to avoid damage to internal components or to its finish. WARNING HAZARD OF ELECTRIC SHOCK, BURN, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. Protect this equipment from contaminants such as water, salts, concrete, and other corrosive environments before and during installation. Do not sit, walk, or stand on this equipment. Failure to follow these instructions can result in death or serious injury. NOTE: If the plug-in unit is not installed and energized immediately, store it in a clean, dry space having a uniform temperature. Plug-in units should not be stored outdoors. For additional handling and storage information, refer to NEMA bulletin BU 1.1. 6 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Plug-In Unit Interrupting Rating Plug-In Unit Interrupting Rating DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Use only Square D brand circuit breakers in this plug-in unit. The circuit breaker catalog prefix must match the plug-in unit prefix. Failure to follow these instructions will result in death or serious injury. Refer to Table 1 for plug-in unit rating information. Table 1: Plug-In Unit Catalog Prefix PBPQOD Plug-In Unit Rating Information Circuit Breaker Catalog Prefix Ampere Rating Listed Short-Circuit Rating ka QOU 10 15 60 QOUVH 22 Volts (ac) Amperage Maximum Rating (Continuous Duty) Volts (ac/dc) 240 100 240 Vac Installing the Plug-In Unit Onto the Busway Standard Application Precautions DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. This plug-in unit must be installed and serviced only by qualified electrical personnel. Do not install the circuit breaker type plug-in unit onto the busway without a circuit breaker installed. Use only Square D brand circuit breakers in this plug-in unit. Do not install the plug-in unit with the cover open or removed. Turn off power to the busway before installing the plug-in unit. Always use a properly rated voltage sensing device to confirm the plug-in unit is de-energized. Failure to follow these instructions will result in death or serious injury. 2012 Schneider Electric All Rights Reserved 7

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 Installing the Plug-In Unit Onto the Busway 06/2012 Schneider Electric has carefully reviewed wording in product hazard messages to alert users to potential hazards, provide instructions to avoid those hazards, and state the consequences of not following hazard messages. Workplace safety standards such as NFPA 70E and CSA Z462 clearly state that the proper method to work on or near electrical equipment is with the equipment in a de-energized state. However, it is recognized that the standards identify exceptions where powering down the equipment is infeasible or actually introduces additional hazards. While elimination of all risk is not possible, in those situations where it can be demonstrated that energized work is necessary, certain tasks, including the installation or removal of Powerbus Circuit Breaker Plug-In Units, may be performed on an energized Powerbus busway only after the user has demonstrated that the application meets the required exceptions. These exceptions are stated in the NFPA 70E, CSA Z462, or other standards as appropriate and employs the work practices and personal protective equipment described in the standard. Pre-Installation Testing Before installing the plug-in unit onto the busway, perform the following steps to conduct a continuity test: 1. Verify the plug-in unit cover is secure (Figure 1). Do not overtighten. 2. Turn the plug-in unit circuit breaker(s) to the ON (I) position. 3. Use a continuity tester or 500 Vdc maximum megohmmeter to verify phase-to-phase, phase-to-neutral, and ground isolation (Figure 2). 4. Turn the circuit breaker(s) to the OFF (O) position. Figure 1: Securing the Plug-In Unit Cover Figure 2: Testing for Plug-In Unit Continuity Prior to Installation 8 2012 Schneider Electric All Rights Reserved

PBPQOD Plug-In Units with 15 60 A Circuit Breakers Installing the Plug-In Unit Onto the Busway Installing the Plug-In Unit 1. Read the safety statements at the beginning of Installing the Plug-In Unit Onto the Busway on page 7 for the appropriate application before installing the plug-in unit onto the busway. 2. Inspect the plug-in unit jaws for contamination. If necessary, clean the jaws and apply more joint compound (part number PJC7201). See Figure 3. 3. Remove the plug-in opening door (see Figure 4). Retain the plug-in opening door inside the plug-in unit for future use. Figure 3: Inspect Plug-In Jaws Figure 4: Removing Plug-In Unit Door 4. Prior to installing the plug-in unit, orient the swing-mount bracket as shown in Figure 6, A on page 10. 5. Orient the plug-in unit so the TOP indication on the plug-in unit nameplate matches the TOP orientation of the busway (Figure 5). 6. Angle the plug-in unit so the load side mounting bracket can be hooked over the top flange of the busway (Figure 5). Figure 5: Plug-In Unit Top Flange Engagement 225 A Busway 100 A Busway 2012 Schneider Electric All Rights Reserved 9 S1B99523 06/2012

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 Installing the Plug-In Unit Onto the Busway 06/2012 Figure 6: Plug-In Location 7. Align the plug-in unit jaws with the busway plug-in opening (see Figure 6, A). Align using the indicator lines on the busway, located left of the plug-in opening with the left plug-in end wall (Figure 6, B and C). Press the line side of the plug-in unit toward the busway to fully engage the plug-in jaws (Figure 6, C). Plug-in unit jaws Swing-mount bracket A B Indicator lines Swing-mount bracket Clamping block C 10 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Installing the Plug-In Unit Onto the Busway 8. Rotate the swing-mount bracket into the clamping block on the plug-in unit and ensure that the hook engages the busway (see Figure 6, B on page 10 and Figure 7, A and B). 9. Hand tighten the handle of the swing-mount bracket by turning the handle clockwise until the plug-in unit is securely fastened to the busway (Figure 7, B and C). DO NOT overtighten. 10. Tighten the jam nut securely against the bracket after the handle is turned (Figure 7, B). 11. If the swing-mount bracket handle is oriented over the plug-in unit cover, pull the spring loaded handle and rotate it away from the cover (Figure 7, C). Figure 7: Securing the Plug-In Unit Onto the Busway A B C 12. The plug-in unit is wired at the factory, so no additional wiring is necessary. 13. The PBPQOD plug-in unit is ready for operation. 2012 Schneider Electric All Rights Reserved 11

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 Removing the Plug-In Unit From the Busway 06/2012 Removing the Plug-In Unit From the Busway Standard Application Precautions DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. This plug-in unit must be installed and serviced only by qualified electrical personnel. Before removing a circuit breaker from inside the plug-in unit: Turn off power to the busway. The circuit breaker must be installed in the plug-in before turning on power to the busway. Do not install, operate, or remove the plug-in unit with the cover open or removed. Always use a properly rated voltage sensing device at all load side connections to confirm the plug-in unit is de-energized. 12 Failure to follow these instructions will result in death or serious injury. Schneider Electric has carefully reviewed wording in product hazard messages to alert users to potential hazards, provide instructions to avoid those hazards, and state the consequences of not following hazard messages. Workplace safety standards such as NFPA 70E and CSA Z462 clearly state that the proper method to work on or near electrical equipment is with the equipment in a de-energized state. However, it is recognized that the standards identify exceptions where powering down the equipment is infeasible or actually introduces additional hazards. While elimination of all risk is not possible, in those situations where it can be demonstrated that energized work is necessary, certain tasks, including the installation or removal of Powerbus Circuit Breaker Plug-In Units, may be performed on an energized Powerbus busway only after the user has demonstrated that the application meets the required exceptions. These exceptions are stated in the NFPA 70E, CSA Z462, or other standards as appropriate and employs the work practices and personal protective equipment described in the standard. NOTE: Drop cord plug-in units are not available for reverse feed applications. 1. Turn the circuit breaker handle to the OFF (O) position (see Figure 8, A on page 14). 2. Turn off the power to the busway. 3. Turn the swing-mount bracket handle counterclockwise until it loosens from the busway (see Figure 7, C on page 11). 4. Lift the swing-mount bracket out of the clamping block. 5. Rotate the plug-in unit outward, away from the busway until the plug-in unit jaws are disengaged from the busway plug-in opening. 6. Lift the plug-in unit upward and slide the mounting hook away from the top rail of the busway (see Figure 5 on page 9). 7. Remove the plug-in unit from the busway. 8. Replace the plug-in opening door of the busway (see Figure 4 on page 9). 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Removing/Replacing the QOU Circuit Breaker from a Plug-In Unit Removing/Replacing the QOU Circuit Breaker from a Plug-In Unit DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. This equipment must be installed and serviced only by qualified electrical personnel. Do not install the circuit breaker with the OFF (O) position of circuit breaker(s) toward the line side of base connectors. Never install a circuit breaker type of plug-in unit onto the busway without a circuit breaker installed. Use only Square D brand circuit breaker in this plug-in unit. The circuit breaker catalog prefix must match the plug-in unit prefix on the nameplate. Do not cross-thread the line side terminal screws when tightening. Visually inspect all QOU circuit breaker line side installations to ensure proper and secure connections. Visually inspect the inside of the plug-in unit to verify all components are installed and all tools have been removed. Never install, operate, or remove the plug-in unit with the cover open or removed. Failure to follow these instructions will result in death or serious injury. The QOU circuit breaker is factory-installed. However, if for some reason the circuit breaker must be removed and replaced, please follow the instructions below. Removing the QOU Circuit Breaker Before removing the QOU circuit breaker, it is necessary to follow all safety precautions and steps in Removing the Plug-In Unit From the Busway on page 12. 1. Follow steps 1 8 on page 12. 2. Remove the cover screws and open the enclosure cover. Retain the screws for future use (Figure 1 on page 8). 3. Disconnect the load and line cables from the QOU circuit breaker(s), if applicable (Figure 8, B on page 14). 4. Pull on the ring located on the line side of the circuit breaker to disengage the mounting clip that secures the circuit breaker to the DIN rail (Figure 8, C on page 14). 5. Rotate the line side of the circuit breaker to disengage the circuit breaker from the DIN rail (Figure 8, D on page 14). 6. For the installation of a replacement circuit breaker, refer to the section Replacing the QOU Circuit Breaker on page 14. 2012 Schneider Electric All Rights Reserved 13

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 Removing/Replacing the QOU Circuit Breaker from a Plug-In Unit 06/2012 Replacing the QOU Circuit Breaker NOTE: The circuit breaker must be replaced with a QOU breaker of the same amperage. 1. Position the circuit breaker into the plug-in unit (refer to Figure 8). a. Turn the circuit breaker handle to the OFF (O) position (Figure 8, A). b. Orient the circuit breaker so the line side terminals are facing the line side cables. Hook the load side over the DIN rail and press the line side until the mounting clip snaps into place (Figure 8, D). c. Refer to the appropriate circuit breaker instruction bulletin provided with the circuit breaker. 2. Close the enclosure cover and reinstall the hardware retained from step 2 in the section Removing the QOU Circuit Breaker on page 13. Figure 8: Removing/Replacing the QOU Circuit Breaker Line side A B Line side Pull ring to disengage mounting clip C D 14 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Operation Operation Turning the Plug-In Unit to the ON (I) and OFF (O) Positions Operate the plug-in unit circuit breaker(s) in a quick, steady motion (Figure 9). Figure 9: Turning the Plug-In Unit to the ON (I) and OFF (O) Positions Accessories and Replacement Parts Refer to Table 2 for accessories and replacement parts: Table 2: Accessories and Replacement Parts Description Busway plug-in opening door Circuit breaker padlock attachment kit Hookstick accessory 1 Joint compound PBQO plug-in unit hookstick operator Catalog Number PBCVR Single pole: QOHPL 2 and 3 pole: QO1HPL Contact your local Schneider Electric representative PJC7201 PBFO100QO 1 The hookstick accessory must be factory ordered with the plug-in unit. Accessories Padlocking Standard Application Precautions DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70E or CSA Z462. This plug-in unit must be installed and serviced only by qualified electrical personnel. Padlock the plug-in handle in the OFF (O) position. Follow all required lock-out and tag-out operations. Do not install, operate, or remove the plug-in unit with the cover open or removed. Always use a properly rated voltage sensing device at all load side connections to confirm the plug-in unit is off. Failure to follow these instructions will result in death or serious injury. 2012 Schneider Electric All Rights Reserved 15

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 General Maintenance 06/2012 General Maintenance Refer to NEMA bulletin BU 1.1 for maintenance instructions. When relocating the plug-in unit, inspect the joint compound on the plug-in jaws for contamination. If necessary, replace the joint compound (part number PJC7201). To order accessories and replacement parts, refer to Table 2 on page 15, or contact your local Schneider Electric representative. 16 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Instruction Bulletin Notes 2012 Schneider Electric All Rights Reserved 17

PBPQOD Plug-In Units with 15 60 A Circuit Breakers S1B99523 Instruction Bulletin 06/2012 Notes 18 2012 Schneider Electric All Rights Reserved

S1B99523 PBPQOD Plug-In Units with 15 60 A Circuit Breakers 06/2012 Instruction Bulletin 2012 Schneider Electric All Rights Reserved 19

PBPQOD Plug-In Units with 15 60 A Circuit Breakers Instruction Bulletin Schneider Electric USA, Inc. 5735 College Corner Road Oxford, OH 45056 USA 1-888-778-2733 www.schneider-electric.us Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. Powerbus, Square D, and Schneider Electric are trademarks or registered trademarks of Schneider Electric. Other trademarks used herein are the property of their respective owners. S1B99523 06/2012 2012 Schneider Electric All Rights Reserved