Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Similar documents
Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure reducing valve, pilot operated

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

2-way flow control valve

Pressure relief valve, pilot operated

Check valve, pilot operated

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Proportional flow control valve, with integrated pressure compensator

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Pressure relief valve, pilot operated

Proportional pressure relief valve, directly operated, rising characteristic curve

3/2 and 4/2 directional seat valves with solenoid actuation

Pressure reducing valve, direct operated, with pressure monitoring

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Bourdon tube pressure switch with infinitely variable switching pressure differential

Pressure relief valve, pilot operated

3/2 and 4/2 directional poppet valve with solenoid actuation

Pressure sequence valve, direct operated

Directional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:

Throttle and throttle check valve

Meter-in pressure compensator, direct operated

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces:

Throttle and throttle check valve

Pressure relief valve, pilot operated

2/2-way poppet valves with solenoid operation Type KSDER1

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure sequence valve, direct operated

Check valve. Type S. Contents. Features. RE Edition: Replaces:

3/2 directional spool valve, direct operated with solenoid actuation

Bourdon tube pressure switch with infinitely variable switching pressure differential

Double throttle check valve Type Z2FS 10

2/2 directional seat valve, direct operated with solenoid actuation

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents

Pressure reducing valve, direct operated

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Proportional pressure reducing valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Pressure reducing valve, direct operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Check valve, pilot operated

Twin throttle check valve

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Pressure relief valve, directly operated

Check valve, pilot operated

Check valve, pilot operated

Supply pressure compensator, direct operated

Check valve cartridge Type M-SR

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Reservoir oil filler/breather

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Hydro-electric pressure switch

Pressure reducing valve, pilot operated Type DR

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Directional spool valves, direct operated, with solenoid actuation. Type WE

Proportional flow control valve, with inductive position transducer

Pressure reducing valve, direct operated

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

2-way flow control valve

Proportional flow control valve, 2-way version

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Block mounting filter, for sandwich plate mounting

Check valve, pilot operated

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Proportional pressure relief valve

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Throttle and throttle check valve

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure reducing valve, pilot operated

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

RC /

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Inline filter with filter element according to DIN 24550

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting

Servo solenoid valves with on-board electronics (OBE)

Block mounting filter, for vertical flange-mounting

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Mating connectors for controlling electrically operated valves and sensors

Pipe burst safety valve

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

2-way proportional throttle valve for block installation

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

RK /02.03 HED 2 OA 2X/.. HED 2 OA 2X/..L.. HED 2 OA 2X/..KL.. HED 2 OA 2X/..K.. HED 2 OA 2X/..K6.. HED 2 1/6 RK /02.

Transcription:

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection RE 08010/10.09 Replaces: 07.07 1/18 Type WE, SED and SEW Size 6 and 10 H7082 Table of contents Features 1 Ordering code, available versions 2, 3 Electrical connections 3 Directional spool valves type WE Technical data 4 and 7 Unit dimensions 5 to 10 Directional seat valves type SED: Technical data 11 and 13 Unit dimensions 12 and 14 Directional seat valves type SEW: Technical data 15 and 17 Unit dimensions 16 and 18 Features with individual connection directly on the solenoid coil with central connection at the housing Integrated operating display with light-emitting diodes (LED) Integrated interference protection circuit (suppressor diode) Electrical power consumption 8 and 30 Watt Function version according to ANSI Information on available spare parts: www.boschrexroth.com/spc

2/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Ordering code, available versions The type designation information in the following tables that is printed in bold is the ordering code for the electrical connection. Points (...) in the listed type designations mark information that is to be amended. This information is to be taken from the ordering code of the respective basic data sheet. Valves with M12x1 plug-in connection are only available with 24 V DC solenoids. Apart from that, there are no other limitations. 3/2, 4/2 and 4/3 directional spool valves Type Features Basic High-performance version Reduced power consumption data sheet.we 6.6X/.EG24.K72L Individual connection 5-pole, integrated 23178, 23183 1) interference protection cir- cuit, operating display with lightemitting diode.we 6.6X/.EG24.K73L Individual connection 5-pole (no 23178, 23183 1) connection pin 1 to pin 2), integrated interference protection circuit, operating display with light-emitting diode.we 6.6X/.EG24.DK24L Central connection 4-pole 23178, 23183 1).WE 6.6X/.EG24.DK35L Central connection 4-pole, integrated interference protection circuit, operating display with light-emitting diode 23178, 23183 1).WE 6.6X/.EG24N9K72L/...SO407 Individual connection 5-pole, integrated 23178-00 interference protection cir- cuit, operating display with lightemitting diode.we 6.6X/.EG24N9K73L/...SO407 Individual connection 5-pole (no 23178-00 connection pin 1 to pin 2), integrated interference protection circuit, operating display with light-emitting diode.we 6.6X/.EG24N9DK35L/...SO407 Central connection 4-pole, integrated interference protection circuit, operating display with light-emitting diode 23178-00.WE 10.3X/.CG24.K72L Individual connection 5-pole, integrated interference protection circuit, operating display with lightemitting diode 23327, 23183 1).WE 10.4X/.CG24.DK24L Central connection 4-pole 23327, 3183 1).WE 10.4X/.CG24.DK35L 5-.WE 10.3X/.CG24.K72L 1) Smoothly switching Central connection 4-pole, integrated interference protection circuit, operating display with light-emitting diode Individual connection 5-pole, integrated interference protection circuit, operating display with lightemitting diode 23327, 23183 1) 23351

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 3/18 Ordering code, available versions 2/2, 3/2 and 4/2 directional seat valves Type Features Basic High-performance version Reduced power consumption data sheet M-.SED 6.1X/350CG24.K72L Individual connection 5-pole, integrated 22049 interference protection cir- cuit, operating display with lightemitting diode M-.SED 10.1X/350CG24.K72L Individual connection 5-pole, integrated 22045 interference protection cir- cuit, operating display with lightemitting diode M-.SEW 6.3X/420MG24.K72L Individual connection 5-pole, integrated interference protection circuit, operating display with lightemitting diode 22058 M-.SEW 6.3X/420MG24N9K72L SO407 Individual connection 5-pole, integrated interference protection circuit, operating display with lightemitting diode 22058 2) M-.SEW 10.1X/420MG24.K72L Individual connection 5-pole, integrated interference protection circuit, operating display with lightemitting diode 22075 2) No separate basic data sheet for version SO407 available. Please use data sheet 22058. Electrical connections Individual connection Central connection K72L DK35L + + 1 4 5 2 3 a 1 4 2 3 + b K73L DK24L + + 1 4 5 2 3 a + 1 4 2 3 b Pin 5 without function With version DK24L, voltage peaks result when the solenoid coil (inductivity) is switched off, which may cause failures or damage in the connected control electronics. For limiting these voltage peaks, a protection circuit must be provided.

4/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Technical data: Type.WE 6.6X/.EG24.(D)K (For applications of the component outside the specified values, please contact us!) hydraulic High performance version (also smoothly switching) Reduced power consumption SO407 Maximum operating pressure Port A, B, P bar [psi] 350 [5076] 315 [4569] Port T bar [psi] 210 [3046] 210 [3046] Maximum flow l/min [US gpm] 80 [21.1] 60 [15.9] Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524 1) ; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221); HETG (rape seed oil) 1) ; HEPG (polyglycols) 2) ; HEES (synthetic esters) 2) ; other hydraulic fluids upon request electrical M12x1 plug-in connections 3) K72L, K73L, DK24L, DK35L K72L, K73L, DK35L Available voltages 4) V 24 Switch-off voltage peak K72L, K73L, DK35L V 44 to 55 44 to 55 limited DK24L V without limitation Voltage tolerance (nominal voltage) % ±10 Power consumption W 30 8 Duty cycle S1 (continuous operation) Switching time according Standard ON ms 25 to 45 up to 60 to ISO 6403 Smoothly switching ON ms 3 to 4 times longer than standard Standard OFF ms 10 to 25 up to 30 Smoothly switching OFF ms 3 to 4 times longer than standard Maximum switching Standard 1/h 15000 7200 frequency Smoothly switching 1/h 7200 Protection class according to DIN EN 60529 IP 65 5) Protection class according to DIN EN 61140 Ⅲ Maximum coil temperature 6) C [ F] 150 [302] 110 [230] 1) Suitable for NBR and FKM seals 2) Only suitable for FKM seals 3) Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006 4) Connection only to functional low voltage with safe insulation = PELV/SELV 5) Only when using the mating connectors specified by us and with correct assembly 6) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and 982 need to be adhered to! For more information, please refer to the corresponding basic data sheet. Valve versions with electrical individual connection K or central connection DK and related basic data sheets see page 2.

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 5/18 Unit dimensions: Type.WE 6.6X/.EG24.K Individual connection (dimensions in mm [inch]) A 17 B [4] 10 [0.39] 12 102 F1 A T B F2 F4 P G F3 12 Space required for removing the mating connector 17 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connections K72L and K73L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the respective basic data sheet: 23178 (standard valve) 23183 (smoothly switching) 23178-00 (reduced power consumption)

6/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type.WE 6.6X/.EG24.DK Central connection (dimensions in mm [inch]) 12 [0.39] 10 48 [1.89] 17 71 98 [3.86] [2.80] F1 A F4 T P G F2 B F3 12 Space required for removing the mating connector 17 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connections DK35L and DK24L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the respective basic data sheet: 23178 (standard valve) 23183 (smoothly switching) 23178-00 (reduced power consumption)

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 7/18 Technical data: Type (5-).WE 10.3X/.CG24.(D)K (For applications of the component outside the specified values, please contact us!) hydraulic Maximum operating pressure Port A, B, P bar [psi] 315 [4569] Port T bar [psi] 210 [3046] Maximum flow l/min [US gpm] 120 [31.7] Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524 1) ; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221); HETG (rape seed oil) 1) ; HEPG (polyglycols) 2) ; HEES (synthetic esters) 2) ; other hydraulic fluids upon request electrical Type.WE 10 (D)K (also smoothly switching) Type 5-.WE 10 K (5-chamber version) M12x1 plug-in connections 3) K72L, DK24L, DK35L K72L Available voltages 4) V 24 Switch-off voltage peak K72L, DK35L V 44 to 55 44 to 55 limited DK24L V without limitation Voltage tolerance (nominal voltage) % ±10 Power consumption W 35 Duty cycle S1 (continuous operation) Switching time according Standard ON ms 45 to 60 45 to 75 to ISO 6403 Smoothly switching ON ms 3 to 4 times longer than standard Standard OFF ms 20 to 30 35 to 45 Smoothly switching OFF ms 3 to 4 times longer than standard Maximum switching Standard 1/h 15000 15000 frequency Smoothly switching 1/h 7200 Protection class according to DIN EN 60529 IP 65 5) Protection class according to DIN EN 61140 Ⅲ Maximum coil temperature 6) C [ F] 150 [302] 110 [230] 1) Suitable for NBR and FKM seals 2) Only suitable for FKM seals 3) Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006 4) Connection only to functional low voltage with safe insulation = PELV/SELV 5) Only when using the mating connectors specified by us and with correct assembly 6) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and 982 need to be adhered to! For more information, please refer to the corresponding basic data sheet. Valve versions with electrical individual connection K or central connection DK and related basic data sheets see page 2.

8/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type.WE 10.3X/.CG24.K72L Individual connection (dimensions in mm [inch]) 20 A B 12 126 [4.96] 10 [0.39] F1 P F2 TA F4 A B TB F3 12 Space required for removing the mating connector 20 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connection K72L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the respective basic data sheet: 23327 (standard valve) 23183 (smoothly switching)

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 9/18 Unit dimensions: Type.WE 10.4X/.CG24.DK Central connection (dimensions in mm [inch]) 12 20 10 [0.39] 48 [1.89] 97,5 125 [3.84] [4.92] 12 Space required for removing the mating connector 20 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connections DK35L and DK24L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the respective basic data sheet: 23327 (standard valve) 23183 (smoothly switching)

10/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type 5-.WE 10.3X/.CG24.K72L Individual connection (dimensions in mm [inch]) 18 A B 10 [0.39] 126 [4.96] 10 F1 P F2 TA F4 A B TB F3 10 Space required for removing the mating connector 18 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connection K72L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the basic data sheet 23351.

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 11/18 Technical data: Type M-.SED 6.-1X/350CG24.K72L (For applications of the component outside the specified values, please contact us!) hydraulic Maximum operating pressure bar [psi] See basic data sheet 22049 (performance limits) Maximum flow l/min [US gpm] 25 [6.6] Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524 1) ; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221); HETG (rape seed oil) 1) ; HEPG (polyglycols) 2) ; HEES (synthetic esters) 2) ; other hydraulic fluids upon request electrical M12x1 plug-in connection 3) Available voltages 4) V 24 K72L Switch-off voltage peak limited V 44 to 55 Voltage tolerance (nominal voltage) % ±10 Power consumption W 30 Duty cycle S1 (continuous operation) Switching time according to ON ms 40 to 70 ISO 6403 OFF ms 10 to 20 (without rectifier) 30 to 45 (with rectifier) Maximum switching frequency 1/h 15000 Protection class according to DIN EN 60529 IP 65 5) Protection class according to DIN EN 61140 Ⅲ Maximum coil temperature 6) C [ F] 150 [302] 1) Suitable for NBR and FKM seals 2) Only suitable for FKM seals 3) Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006 4) Connection only to functional low voltage with safe insulation = PELV/SELV 5) Only when using the mating connectors specified by us and with correct assembly 6) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and 982 need to be adhered to! For more information, please refer to the basic data sheet 22049.

12/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type M-.SED 6.-1X/350CG24.K72L (dimensions in mm [inch]) 102 [4] 10 [0.39] 6 11 F1 T F2 F4 A P B F3 6 Space required for removing the mating connector 11 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connection K72L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the basic data sheet 22049.

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 13/18 Technical data: Type M-.SED 10.-1X/350CG24.K72L (For applications of the component outside the specified values, please contact us!) hydraulic Maximum operating pressure bar [psi] See basic data sheet 22045 (performance limits) Maximum flow l/min [US gpm] 40 [10.6] Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524 1) ; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221); HETG (rape seed oil) 1) ; HEPG (polyglycols) 2) ; HEES (synthetic esters) 2) ; other hydraulic fluids upon request electrical M12x1 plug-in connection 3) Available voltages 4) V 24 K72L Switch-off voltage peak limited V 44 to 55 Voltage tolerance (nominal voltage) % ±10 Power consumption W 30 Duty cycle S1 (continuous operation) Switching time according to ON ms 30 to 50 ISO 6403 OFF ms 10 to 20 (without rectifier) 35 to 45 (with rectifier) Maximum switching frequency 1/h 15000 Protection class according to DIN EN 60529 IP 65 5) Protection class according to DIN EN 61140 Ⅲ Maximum coil temperature 6) C [ F] 150 [302] 1) Suitable for NBR and FKM seals 2) Only suitable for FKM seals 3) Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006 4) Connection only to functional low voltage with safe insulation = PELV/SELV 5) Only when using the mating connectors specified by us and with correct assembly 6) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and 982 need to be adhered to! For more information, please refer to the basic data sheet 22045.

14/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type M-.SED 10.-1X/350CG24.K72L (dimensions in mm [inch]) 102 [4] 10 [0.39] 5 13 F1 P F2 A B F4 TA TB F3 5 Space required for removing the mating connector 13 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connection K72L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the basic data sheet 22045.

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 15/18 Technical data: Type M-.SEW 6.-3X/420MG24.K72L (For applications of the component outside the specified values, please contact us!) hydraulic Maximum operating pressure bar [psi] See basic data sheet 22058 (performance limits) Maximum flow l/min [US gpm] 25 [6.6] Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524 1) ; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221); HETG (rape seed oil) 1) ; HEPG (polyglycols) 2) ; HEES (synthetic esters) 2) ; other hydraulic fluids upon request electrical M12x1 plug-in connection 3) Available voltages 4) V 24 High-performance version K72L Switch-off voltage peak limited V 44 to 55 Voltage tolerance (nominal voltage) % ±10 Reduced power consumption SO407 Power consumption W 30 8 Duty cycle S1 (continuous operation) Switching time according to ISO 6403 ON ms 25 to 40 (without rectifier) 30 to 55 (with rectifier) OFF ms 10 to 15 (without rectifier) 35 to 55 (with rectifier) Maximum switching frequency 1/h 15000 7200 Protection class according to DIN EN 60529 IP 40 5) Protection class according to DIN EN 61140 Ⅲ Maximum coil temperature 6) C [ F] 150 [302] 110 [230] 50 (spool symbol C ) 55 (spool symbol U ) 30 (spool symbol C ) 15 (spool symbol U ) 1) Suitable for NBR and FKM seals 2) Only suitable for FKM seals 3) Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006 4) Connection only to functional low voltage with safe insulation = PELV/SELV 5) Only when using the mating connectors specified by us and with correct assembly 6) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and 982 need to be adhered to! For more information, please refer to the basic data sheet 22058 (without version SO407 ).

16/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type M-.SEW 6.-3X/420MG24.K72L (dimensions in mm [inch]) 15 6 132 [5.20] 10 [0.39] F1 T F2 B F4 A P F3 6 Space required for removing the mating connector 15 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connection K72L see page 3 0,01/100 [0.0004/4.0] Rzmax 4 Required surface quality of the valve mounting face For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the basic data sheet 22058.

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 17/18 Technical data: Type M-.SEW 10.-1X/420MG24.K72L (For applications of the component outside the specified values, please contact us!) hydraulic Maximum operating pressure bar [psi] See basic data sheet 22075 (performance limits) Maximum flow l/min [US gpm] 40 [10.6] Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524 1) ; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221); HETG (rape seed oil) 1) ; HEPG (polyglycols) 2) ; HEES (synthetic esters) 2) ; other hydraulic fluids upon request electrical M12x1 plug-in connection 3) Available voltages 4) V 24 K72L Switch-off voltage peak limited V 44 to 55 Voltage tolerance (nominal voltage) % ±10 Power consumption W 30 Duty cycle S1 (continuous operation) Switching time according to ISO 6403 ON ms 25 to 60 (without rectifier) 30 to 70 (with rectifier) OFF ms 10 to 20 (without rectifier) 30 to 70 (with rectifier) Maximum switching frequency 1/h 15000 Protection class according to DIN EN 60529 IP 40 5) Protection class according to DIN EN 61140 Ⅲ Maximum coil temperature 6) C [ F] 150 [302] 1) Suitable for NBR and FKM seals 2) Only suitable for FKM seals 3) Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006 4) Connection only to functional low voltage with safe insulation = PELV/SELV 5) Only when using the mating connectors specified by us and with correct assembly 6) Due to the surface temperatures of the solenoid coils, the standards ISO 13732-1 and 982 need to be adhered to! For more information, please refer to the basic data sheet 22075.

18/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Unit dimensions: Type M-.SEW 10.-1X/420MG24.K72L (dimensions in mm [inch]) 15 6 132 [5.20] 10 [0.39] F1 A P F2 B 0,01/100 [0.0004/4.0] Rzmax 4 F4 TA TB F3 Required surface quality of the valve mounting face 6 Space required for removing the mating connector 15 M12x1 plug-in connection with operating display LED (Mating connectors according to IEC 60947-5-2, separate order, see data sheet 08006); Electrical connection K72L see page 3 For missing dimensions, position explanations, valve mounting screws and subplates, please refer to the basic data sheet 22075. Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 08010/10.09 M12x1 plug-in connection Hydraulics Bosch Rexroth AG 19/18 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

20/18 Bosch Rexroth AG Hydraulics M12x1 plug-in connection RE 08010/10.09 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.