OPERATING INSTRUCTIONS. Models SI-1400 through SI-1406

Similar documents
SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup (2700 for 50Hz models)

SPECIFICATIONS. Vortex-Genie Model Vortex-Genie 1 Vortex-Genie 2 Supplied Pop-off Cup 3-inch Platform, Pop-off Cup 3200

Incubators. Incubators

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

Model 700 Microarray Oven

Rockers, Rotators and Mini Shakers

FlexChem Model 404 Rotating Oven

Instruction Manual. Vortex Mixers

Thermo Scientific Variomag Magnetic Stirrers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Hybex Microsample Incubator

Hybridization Ovens. Versatile instruments for common hybridization applications

MyGel Mini. Operating Manual Version 1.2. a division of. Electrophoresis System. 6 Troubleshooting (continued) Problem Causes Resolutions

Shaking Incubators & Shakers

POWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE

Model 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES

3-D GYRATORY ROCKERS.

Boekel Complete Culture Control Incubators

Product Overview of GYROZEN Centrifuges

3 Liter Programmable Centrifuges

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Rockers &Shakers Shakers

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

Fisher Scientific. Rockers, Rotators and Shakers

PNA FISH Workstation Operating Instructions

Orbital Shaker-Incubator ES-80

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

Centrifuge Operator / Service Manual

Exceptional Choice for Versatile and Reliable Shaking Application

Barnant Company (Type J) (Type K) (Type T)

2016 Catalogue. Shaker. v1.0

Digital incubating/ refrigerating benchtop shakers.

BENCHTOP SHAKING INCUBATOR

6332A / 7342A Temperature Calibration Baths. Fast, 0.01 C stability baths backed by Fluke metrology

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

Mixer/Temperature Control

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P.

Mai Tai Hybridization System

Exceptional Choice for Versatile and Reliable Shaking Application

BARNSTEAD THERMOLYNE CORPORATION MEL-TEMP 3.0 OPERATING INSTRUCTIONS. Model No LT1186X4 5/1/00

GENERAL PURPOSE INCUBATOR

EVOS M5000 Imaging System

Heavy Duty Orbital Shakers

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

Thermistor Thermometer MODEL NO

ORBITAL SHAKER. Note: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

3000 SERIES DRY-BLOCK HEAT SOURCE

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Corning Equipment Guide

Operators Manual. Microprocessor Controlled Water Baths /98

STARTER 2000 Bench ph Meter Instruction Manual

Thermo Scientific Precision Water Baths Precision redefined for your lab

Grain Moisture Meter. Operators manual

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

FireLite Operation Manual

Model : LMHS-40 Please read this manual carefully before using the instrument Labnics Equipment

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

Thermocouple Thermometer Models

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

Lumitester PD-30. Instruction Manual. Table of Contents

ISO-9001:2008 CENTRIFUGES CATALOG. Phone: Fax: Web: expotechusa.com

DOUBLE WAYS THERMOCOUPLE METER. Users Manual

6109A / 7109A. Portable Calibration Baths. Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators

Product Data Sheet : LIGHTHAWK 6 CELL

ASSEMBLED BY HAND IN THE USA

We do not want to forget these words!

E v a p o r a t o r s

OPERATION MANUAL MiniStirrus MAGNETIC STIRRER/HEATER VP 706B-4H

(Type J) (Type K) (Type T)

Operation Manual for the Drummond Pipet-Aid XL

Operating Manual Cellspin

Instruction Manual. Single-Input Thermistor Thermometer (Model )

HCT-10 Temperature Controller User Manual

Hybridization Oven System Guide

LARGE CAPACITY INCUBATOR Installation, Operation and Maintenance Instructions

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL

LM series. LE series. DK series. TS series. BH BU BL BT series. GC series. DS series. LR series

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Radnoti Modular Wire Myograph System Assembly and Basic Principles

DRY BATH INCUBATOR (HEATING BLOCKS) Model: DB-005, DB-006, DB-006E

XCM12 Mini-Centrifuge

OPERATING & SERVICE PARTS MANUAL SM20ES ENERGY SMART WRAPPER

OPERATING MANUAL TS - 4 Thermal Microscope Stage

shak er ES-X (Lab-Shaker) Shaker with separate control unit suitable for use in incubators with humidity

OPERATION MANUAL. Manual for GW2 2-port and GW3 3-port Dispensers. Java Creations Iced Coffee & Java Works Creamery Classics machines

Temp-14 Single Input Thermistor Thermometer

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES B

The Safest Heating Method!

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

WalkLAB Digital Dissolved Oxygen meter HD9030

RADIO FREQUENCY SYSTEMS

Exceptional Choice for Versatile and Reliable Shaking Application

PHscan30S Pocket ph Meter Instruction Manual

Bipolar Temperature Controller

TABLE OF CONTENTS TABLE OF CONTENTS.

Environmental/Analytical LabCivil Engineering Lab Equipment

Tri-Temp Bipolar Temperature Controller

Protein Electrophoresis Unit

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

Transcription:

INCUBATOR-GENIE TM OPERATING INSTRUCTIONS Models SI-1400 through SI-1406 U.S. PAT 5,918,979 80 Orville Drive, Suite 102, Bohemia, NY 11716 U.S.A. Phone: (631) 567-4700 Fax: (631) 567-5896 Toll Free: 888-850-6208 Customer Service: custsvc@scientificindustries.com www.scientificindustries.com

INCUBATOR-GENIE Environmentally Controlled Benchtop 3-in-1 Incubator / Rotator / Rocker The Incubator-Genie is an Incubator / Rotator / Rocker for the study of micro-organisms and tissue cell growth under strictly controlled conditions of temperature and agitation. Designed to provide the security of precise temperature control and uniformity for demanding incubation applications without taking up a great deal of space. It performs membrane-based assays/washings and hybridizations more efficiently. Chamber air is gently and continuously circulating at a rate that ensures the temperature consistency and uniformity of all test samples. Shatter resistant viewing window allows for inspection of samples without affecting the chamber environment. Microprocessor control easily achieves desired rotating/rocking speed and temperature which are shown on large, easy to read displays for accurate reproducible conditions. Visible and audible alarms exist for temperature. FEATURES: 28 C to 75 C precise temperature range Microprocessor controls allow for accurate, reproducible conditions Economical, space saving, and secure SPECIFICATIONS: Temperature and Settings Heating to 75 C Accuracy ±1.0 C Uniformity ±1.0 C Resolution 1.0 C Stability ±1.0 C Alarms: Visible & audible for temperature Rocking 6-70 cycles per minute Rotating 3-35 RPM Size Overall: 400mm x 560mm x 370mm (15.9 x 21.13 x 14.5 ) Chamber: 254mm x 362mm x 260mm (10 x 14.25 x 10.25 ) Chamber Volume: 24 Liters Electrical 120 Volt AC, 5 Amp (SI-1400) 230 Volt AC, 2.5 Amp (SI-1401, SI-1402, SI-1403, SI-1404) 100 Volt AC 5 Amp (SI-1405) (Nominal voltages not to vary by more than 10%) 2-Year Warranty CE 2

This symbol on the Incubator-Genie means: Attention: Refer to accompanying documents. OPERATING INSTRUCTIONS CAUTION! Failure to follow operating instructions can compromise the user s safety. DISPLAY CONTENTS Power on the Incubator-Genie (front rocker switch below the control panel). The display will briefly show the software revision: Up/Down buttons Up/Down buttons Start/Stop button After 5 seconds the display will show temperature and speed settings and begin to control temperature. BUTTON FUNCTIONS UP and DOWN buttons in the temperature area are used for: Changing the temperature value UP and DOWN buttons in the speed area are used for: Changing the rocking/rotating speed value MIXER MODES The Incubator-Genie has 2 Mixer Modes. ROTATE/ROCK OFF (Environmental Chamber - no mixing) To activate OFF mixing mode, press the SPEED down button until the display shows (--) START/STOP button is used for starting/stopping rocking/rotating. 3

RANGE OF PARAMETER CHANGE TEMP: 25 to 75 C in 1 C increments. SPEED: ROTATE mode : 3 to 35 RPM ROCK mode : 6 to 70 RPM MIXER OPERATION The mixer can be turned on/off by pressing the START/STOP button. TEMPERATURE REGULATOR OPERATION When the unit is first turned ON (rocker switch below control panel), the heaters and fan will turn on and begin regulating toward the set temperature. During this time, the temperature display will blink green. The display will become solid green after achieving the desired temperature. Pressing the Up or Down Arrow buttons in the temperature control area allows you to change the desired temperature. While adjusting temperature, the display will be amber in color. Once the temperature has reached the set value, a change of ±2 C in the measured temperature will chandge the displayed value to solid red. At ±3 C deviation, the display will blink red. At ±4 C the display will blink red and the alarm will sound. Note: This device is not capable of achieving a chamber temperature that is less than the ambient room temperature. through the door seal and will not affect performance. Measure the temperature in the chamber via the lab thermometer, after chamber temperature has been allowed to settle for twenty minutes. Note the difference in temperature between Incubator- Genie displayed temperature and your lab thermometer temperature (ex. Incubator-Genie display reads 37 C, lab thermometer reads 38 C; difference is 1 C). This difference is the calibration value to be entered. To access the calibration menu, simultaneously press and hold the UP ARROW button in the temperature control area and the START/STOP button while turning the unit ON The parameters on the display show: TEMPERATURE: The temperature blinks amber and begins adjusting to reach the last temperature setting. Once there, it changes to solid amber SPEED: 0 The speed readout displays 0 in an amber color and can be adjusted ± 9 for each C desired. Blinking amber display Press simultaneously to calibrate CALIBRATION MODE The Incubator-Genie is electronically factory calibrated and should not need calibration, nor is it recommended. However, should the need arise, the unit may be calibrated, as follows: In order to calibrate, you will need to make an independent measurement of the chamber temperature. Make sure the thermometer is accurate! Generally speaking, glass thermometers found around the lab will be less accurate than your Incubator-Genie. Good, certified glass or digital thermometers are available from laboratory supply dealers. A thermocouple wire may be passed Press to exit Press the START/STOP button to exit calibration mode. 4

ROTATE/ROCK Incubator-Genie comes equipped with a magnetic platform that is used for rotating and rocking. Installing/removing the magnetic platform is easy, but may take a few times to get used to. Try the following technique: Install the magnetic platform by first unscrewing the lock shaft until the end of the lock shaft is flush with the right hand sidewall of the inside of the chamber. To remove the platform, reverse the above procedure. To select rotating mode: 1. Press the lock release. 2. Shift the magnetic platform to the right. 3. While shifting the platform right, release the lock release and line up the hex shaft to engage the lock shaft properly. 4. The platform will lock in place when it reaches the correct position. Grab the magnetic platform with the label side up, so that you can read the label. Hold the platform in the chamber and insert the hex shaft on the left side of the chamber into the hex hole in the magnetic platform. You may need to rotate the platform slightly to align the shaft with the hole. To select rocking mode: 1. Press the lock release. 2. Shift the magnetic platform to the left. 3. While shifting the platform left, release the lock release and rotate the platform to line up the pin and the pin slot in the end of the platform. Shift the platform onto the pin. 4. The platform will lock in place when it reaches the correct position. Now hold up the right side of the platform, while depressing the blue lock release. Screw the lock shaft into the hole in the magnetic platform making sure the blue lock release is depressed. When the lock shaft is screwed all the way in, let go of the lock release. 5

The versatile magnetic platform can be loaded a variety of ways using both sides of the platform: Positioning the plates as shown below will produce a rotating or rocking motion in the tubes. To rock open trays or racks, center on the metal rocker tray. NOTE: The metal rocker tray must be used in rocking mode only. It will not clear the housing if rotated. Positioning the plates as shown below will produce a rolling or rocking motion in the tubes. To rotate or rock bags, select mode of operation (Rotate or Rock); locate the bags in the desired position using 2 or 4 (depending on application) magnetic stainless steel mounting strips to hold them in place. Four mounting strips are supplied more can be ordered (see Accessories). The platform capacity for bags can also be expanded (see Accessories). Positioning the plates as shown below will produce a combination rotating/rolling motion ( Figure 8 motion) in the tubes. Adjust the angle to achieve the desired motion. Various size tubes can be placed on the magnetic platform in different orientations to produce different motions within the tubes. First select the size clip plate required. The large clips hold 28-30mm dia. (50ml) tubes, the medium clips hold 15-17mm dia. (15ml) tubes and the small clips hold 10-13mm dia. (1.5-2.0ml) tubes. One clip plate of each size is supplied. The platform can hold up to eight plates (see Accessories). Push the tubes into the clips. NOTE: When rotating tubes, rotate the magnetic platform by hand before starting, to check the clearance of the tubes to the chamber walls. PLATFORM CAPACITY Centered on Axis: 4.5kg (10lb) Offset: 2.3kg (5lb) 6

ENVIRONMENTAL CHAMBER ONLY The Incubator-Genie may be used as a temperature chamber when the platform is not installed. A wire rack is included to increase the capacity of the chamber. An additional rack (sold separately) may be stacked on the first rack to further increase capacity (see Accessories).. NOTE: Please check our website (www.scientificindustries.com) for any updates to this document 7

Incubator-Genie Accessories SI-1120 Small Tube Plates Add extra small tube capacity! Each kit contains six 10-13mm diameter tube plates (12 tubes per plate). Ideal for microcentrifuge or other small tubes. SI-1121 Medium Tube Plates Add extra medium tube capacity! Each kit contains six 15-17mm diameter tube plates (6 tubes per plate). Ideal for 15ml centrifuge or other medium tubes. SI-1122 Large Tube Plates Add extra Large Tube Capacity! Each kit contains six 28-30mm diameter tube plates (3 tubes per plate). Ideal for 50ml centrifuge of other larger tubes. SI-1126 Bag Mounting Strips Add extra bag capacity! Each kit contains sixteen magnetic stainless steel mounting strips. Ideal for bag washings of blots. 8

Incubator-Genie Accessories SI-1127 Bag Expansion Kit Add even more Bag Capacity! Each kit contains two trays (for use on magnetic platform) and 24 flexible mounting strips. SI-1130 Hybridization Tube Plates Use your Incubator-Genie as a hybridization oven! Each kit contains two clips suitable for 42-45mm diameter tubes. SI-1131 Additional Wire Rack Add extra capacity to your Incubator-Genie! This extra rack will stack on top of your existing rack to increase shelf space. 9

Incubator -Genie Parts Assembly List To order parts for the Incubator-Genie: Contact your local distributor or visit www.scientificindustries.com Please specify part number, quantity and voltage. 4 5 6 3 8 2 7 1 Indicator# Part# Description 1 0A-1400-002 KIT, MOTOR ASSEMBLY, INCUBATOR-GENIE 2 0K-1400-902 KIT, POWER SUPPLY 3 0K-1400-202 PANEL, POWER SUPPLY 4 0K-1400-203 BACK PANEL, INCUBATOR-GENIE 5 0A-1100-030 PLATFORM ASSEMBLY 6 0M-1200-214 LOCKSHAFT, PLATFORM 7 HWP0034 BUMPER, 1 DIA X 1 LG. 8A 318-0510-02 LINECORD 120V 8B 0A-1101-015 LINECORD, 230V W/O PLUG 8C 0A-1102-015 LINECORD, 230V EUROPEAN PLUG 8D 0A-1103-015 LINECORD, 230V BRITISH PLUG 8E 0A-1104-015 LINECORD, 230V SWISS PLUG 8F 0A-1105-015 LINECORD, 100V 1 3 2 Indicator# Part# Description 1 0K-1200-908 KIT, MOTOR DRIVE, INCUBATOR-GENIE 2 0K-1200-909 KIT, SMALL GEAR, 30T, INCUBATOR-GENIE 3 0K-1200-910 KIT, HEX SHAFT, INCUBATOR-GENIE 10

Incubator -Genie Parts Assembly List To order parts for the Incubator-Genie: Contact your local distributor or visit www.scientificindustries.com Please specify part number, quantity and voltage. 1 2 3 Indicator# Part# Description 1 0K-1200-905 KIT, TEMPERATURE SENSOR, INCUBATOR-GENIE 2 0K-1200-906 KIT, FAN TEC ASSEMBLY, INCUBATOR-GENIE 3 0K-1400-903 KIT, HEATING ELEMENT, INCUBATOR-GENIE 5 4 1 3 2 Indicator# Part# Description 1 0K-1400-900 KIT, LED DISPLAY BOARD 2 0K-1400-901 KIT, LED DISPLAY KEYPAD 3A ESP0006 SWITCH, ROCKER, 120V/100V 5A 3B ESP0007 SWITCH, ROCKER, 230V 2.5A 4 0K-1200-902 KIT, DOOR LATCH, INCUBATOR-GENIE 5 0K-1200-915 KIT, DOOR, INCUBATOR-GENIE 11

CAUTION! Do not subject the Incubator-Genie to excessive shock. Dropping the unit, or otherwise subjecting it to unnecessary shock (ie: using excessive force to place vessels on the unit) may crack the case and lead to unsafe conditions. CAUTION! Failure to follow operating instructions can compromise the user s safety. CARE & HANDLING The Incubator-Genie should be given the care normally required for any electrical appliance. Avoid wetting or unnecessary exposure to fumes. The finish can be washed with a damp cloth (after unplugging) and soap or mild detergents. Keep the unit clean by immediately blotting any spills. CAUTION! Unplug from power before cleaning. Do not immerse. CAUTION! Do not use Incubator-Genie in hazardous atmospheres or with hazardous materials. CAUTION! Do not use Incubator-Genie in applications such as mixing of flammable materials or where the transfer of mechanical energy to glass apparatus could lead to breakage. TECHNICAL SPECIFICATIONS The Incubator-Genie is classified as Installation Category 2 Environmental: 0 C 38 C (32 F-100 F), 95% Humidity max. MODEL POWER REQUIRED AMPS SI-1400 120V 2.5 SI-1401 230V - No Plug 1.5 SI-1402 230V - European Plug 1.5 SI-1403 230V - British Plug 1.5 SI-1404 230V - Swiss Plug 1.5 SI-1406 230V - Australian Plug 1.5 SI-1405 100V 2.0 Weight: 19.5 Kg (43 lbs) Maximum Load: Centered on Axis: 4.5kg (10lb.) Offset: 2.3kg (5lb.) Dimensions: Overall: 404mm x 538mm x 366mm (15.9 x 21.13 x 14.5in.) Chamber: 254mm x 362mm x 260mm (10 x 14.25 x 10.25in.) Chamber Volume: 24 Liters (0.86ft 3 ) Scientific Industries Inc. 70 Orville Drive, Bohemia, NY 11716 U.S.A. (631) 567-4700 Fax (631) 567-5896 Toll Free 888-850-6208 Email for Customer Service: custsvc@scientificindustries.com Email for all other information or inquiries; info@scientificindustries.com www.scientificindustries.com 2014 Scientific Industries, Inc. LTP0067 Rev. C 12