TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP Page /5 DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP from 0... 00 mbar up to 0... 40 bar Output signals -wire: 4... 0 ma -wire: 0 0 ma / 0 0 V others on request Special characteristics perfect thermal behaviour excellent long term stability pressure port G /" flush from 00 mbar on Optional versions IS-version Ex ia = intrinsically safe for gases and dusts SIL according to IEC 6508 / IEC 65 pressure sensor welded specific versions The pressure transmitter DMP can be used in all industrial areas when the medium is compatible with stainless steel.4404 (6 L) or.445 (6 L). Additional are different elastomer seals as well as a helium tested welded version available. The modulare concept of the device allows to combine different stainless steel sensors and electronic modules with a variety of electrical and mechanical versions. Thus a diversity of variations is created, meeting almost all requirements in industrial applications. Preferred areas of use are Plant and Machine Engineering Environmental Engineering (water - sewage - recycling) Energy Industry 07/0
TEMATEC GmbH Data Sheet DMP Page /5 Input pressure range gauge / abs. [bar] - 0 0.0 0.6 0.5 0.40 0.60.6 Overpressure [bar] 5 0.5 5 5 0 Burst pressure [bar] 7.5.5.5.5 7.5 7.5 5 gauge / abs. [bar].5 4 6 0 6 5 40 Overpressure [bar] 0 0 40 40 80 80 05 Burst pressure [bar] 5 5 50 50 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request Output signal / Supply Standard -wire: 4... 0 ma / V S = 8... V DC Option IS-protection -wire: 4... 0 ma / V S = 0... 8 V DC Options -wire -wire: 0... 0 ma / V S = 4... 0 V DC 0... 0 V / V S = 4... 0 V DC Performance Accuracy standard: nominal pressure < 0.4 bar: 0.5 % FSO nominal pressure 0.4 bar: 0.5 % FSO option : nominal pressure 0.4 bar: 0.5 % FSO option : for all nominal pressure: 0. % FSO Permissible load current -wire: R max = [(V S V S min) / 0.0] current -wire: R max = 500 voltage -wire: R min = 0 k Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / k Long term stability 0. % FSO / year at reference conditions Response time -wire: 0 msec -wire: msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) P N [bar] - 0 0.40 0.40 Tolerance band [% FSO] 0.75 0.75 in compensated range [ C] -0... 85 0... 70-0 85 Permissible temperatures Permissible temperatures medium: -40... 5 C electronics / environment: -40... 85 C storage: -40... 00 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (5... 000 Hz) according to DIN EN 60068--6 Shock 500 g / msec according to DIN EN 60068--7 Materials Pressure port stainless steel.4404 (6 L) Housing stainless steel.4404 (6 L) Option compact field housing stainless steel.405 (0), cable gland brass, nickel plated others on request Seals (media wetted) standard: FKM options: EPDM NBR welded version others on request Diaphragm stainless steel.445 (6 L) Media wetted parts pressure port, seals, diaphragm welded version only with pressure ports according to EN 87 Explosion protection (only for 4 0 ma / -wire) Approval DX9-DMP IBExU 0 ATEX 068 X zone 0: II G Ex ia IIC T4 Ga zone 0: II D Ex ta IIIC T 85 C, IP6x in preparation Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 H Permissible temperatures for in zone 0: -0... 60 C with p atm 0.8 bar up to. bar environment in zone or higher: -0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: H/m 07/0
TEMATEC GmbH Data Sheet DMP Page /5 Miscellaneous Option SIL according to IEC 6508 / IEC 65 Current consumption signal output current: max. 5 ma signal output voltage: max. 5 ma Weight approx. 40 g Installation position any Operational life > 00 x 0 6 pressure cycles CE-conformity EMC Directive: 004/08/EC Pressure transmitters are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviations in the zero point for pressure ranges PN bar. Wiring diagrams -wire-system (current) p supply + -wire-system (current / voltage) supply + p VS VS supply I supply I/U signal + A/V Pin configuration Electrical connection ISO 4400 Supply + Supply Signal + (for -wire) Electrical connections (dimensions in mm) Binder 7 (5-pin) 4 Mx / metal (4-pin) Shield ground pin 5 4 field housing IN + IN - OUT+ cable colours (DIN 4700) wh (white) bn (brown) gn (green) gn/ye (green / yellow) standard option ISO 4400 Binder Series 7 5-pin Mx 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP 67) 4 compact field housing cable outlet, cable with ventilation tube (IP 67) (IP 68) 5 universal field housing stainless steel.4404 (6 L) with cable gland M0x.5 (ordering code 880) and other versions on request 4 standard: m PVC cable without ventilation tube (permissible temperature: -5... 70 C) 5 different cable types and lengths available, permissible temperature depends on kind of cable 07/0
TEMATEC GmbH Data Sheet DMP Page 4/5 Mechanical connections (dimensions in mm) standard for accuracy 0.5 / 0.5 % standard for accuracy 0. %; SIL- and SIL-IS-version option G/" DIN 85 G/" DIN 85 with ISO 4400 with ISO 4400 G/" EN 87 G/" open port G/" DIN 85 with flush sensor G/4" DIN 85 G/4" EN 87 /" NPT /4" NPT metric threads and other versions on request 07/0 This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.
TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP Page 5/5 Ordering code DMP DMP - - - - - - - Pressure Input Output 4 0 ma / -wire 0 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire SIL 4 0 ma / -wire SIL with intrinsic safety 4 0 ma / -wire Accuracy standard for P N 0.4 bar standard for P N < 0.4 bar option for P N 0.4 bar option Electrical connection Male and female plug ISO 4400 Male plug Binder series 7 (5-pin) Cable outlet with PVC cable Cable outlet Male plug Mx (4-pin) / metal Compact field housing stainless steel.405 Mechanical connection G/" DIN 85 G/" EN 87 G/4" DIN 85 G/4" EN 87 G/" DIN 85 with flush sensor G/" DIN 85 open pressure port /" NPT /4" NPT Seals FKM EPDM NBR without (welded version) Special version standard gauge absolute 0 [bar] 0.0 0 0 0 0.6 6 0 0 0.5 5 0 0 0.40 4 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0.5 5 0 4.0 4 0 0 6.0 6 0 0 0 0 0 6 6 0 5 5 0 40 4 0 0-0 X 0 9 E S ES 0.5 % 0.5 % 5 0.5 % 0% 0. 0 0 0 0 T A 0 T R 0 M 0 8 5 0 0 0 0 0 0 0 4 0 0 F 0 0 H 0 0 N 0 0 N 4 0 5 0 0 0 standard: m PVC cable without ventilation tube (permissible temperature: -5 70 C), others on request st cable with ventilation tube (code TR0 = PVC cable), different cable types and lengths available, price without cable welded version only with pressure ports according to EN 87 07/0