Drive Technology \ Drive Automation \ System Integration \ Services *23582456_0817* Revision MOVIMOT MM..D with AC Motors DT/DV Edition 08/2017 23582456/EN
SEW-EURODRIVE Driving the world
Amendments/revisions Type designation of the design "mounted close to the motor" 1 1 Amendments/revisions The following documentation has been amended and revised. Observe the data specified in this revision. This document does not replace the detailed operating instructions/compact operating instructions. "MOVIMOT MM..D with AC Motors DT/DV" operating instructions "MOVIMOT MM..D with AC Motors DT/DV" compact operating instructions 1.1 Type designation of the design "mounted close to the motor" 1.1.1 Nameplate Order-specific nameplate The following figure provides an example of an order-specific nameplate of the MOVIMOT inverter for mounting close to the motor: Made in Germany Feldverteiler Field Distributor 01 S0#: Type: Input: P-Motor = 1,5kW 95.7416041003.0001.17 MM15D-503-00/0/P21A/RO1A /APG4 IP65 ML 0001 U= 3x380...500V I= 3,5A AC C U L US LISTED IND.CONT.EQ. 2D06 General nameplate The following figure provides an example of a general nameplate of the MOVIMOT inverter for mounting close to the motor: Input: U= 3x200...500V Imax= Input: U= 3x200...500V Imax= 1,3...3,5A AC f= 50...60Hz Output to next Field Distributor: U= Imax= Output to drive: U= 3x0...Uinput Imax= 1,6...4,0A AC P-Motor= 0,25...1,5kW Revision MOVIMOT MM..D with AC Motors DT/DV 3
2 Mechanical installation Mounting position 2 Mechanical installation 2.1 Mounting position Install the MOVIMOT inverter MM40D (4 kw) in mounting position M2 (heat sink on bottom, see right figure) close to the motor only if ambient temperatures are ϑ u 35 C. ϑ u 35 C MM40D 4 Revision MOVIMOT MM..D with AC Motors DT/DV
Electrical installation Installation instructions 3 3 Electrical installation 3.1 Installation instructions 3.1.1 UL-compliant installation INFORMATION Due to UL requirements, the following chapter is always printed in English independent of the language of the documentation. Field wiring power terminals Observe the following notes for UL-compliant installation: Use 60/75 C copper wire only. Tighten terminals to 1.5 Nm (13.3 lb.in) Short circuit current rating Suitable for use on a circuit capable of delivering not more than 200,000 rms symmetrical amperes when protected as follows For 240 V systems: 250 V minimum, 25 A maximum, non-semiconductor fuses or 250 V minimum, 25 A maximum, inverse time circuit breakers For 500 V systems: 500 V minimum, 25 A maximum, non-semiconductor fuses or 500 V minimum, 25 A maximum, inverse time circuit breakers The max. voltage is limited to 500 V. Branch circuit protection Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes. For maximum branch circuit protection see table below. Series non-semiconductor fuses inverse time circuit breaker MOVIMOT MM..D 250 V/500 V minimum, 25 A maximum 250 V/500 V minimum, 25 A maximum Motor overload protection MOVIMOT MM..D is provided with load and speed-sensitive overload protection and thermal memory retention upon shutdown or power loss. The trip current is adjusted to 140 % of the rated motor current. Revision MOVIMOT MM..D with AC Motors DT/DV 5
3 Electrical installation Installation instructions Ambient temperature MOVIMOT MM..D is suitable for an ambient temperature of 40 C, max. 60 C with derated output current. To determine the output current rating at higher than 40 C, the output current should be derated 3.0 % per C between 40 C and 60 C. Only use certified units with a limited output voltage (V max = DC 30 V) and limited output current (I 8 A) as an external DC 24 V voltage source. The UL certification only applies for the operation on voltage supply systems with voltages to ground of max. 300 V. The UL-certification does not apply to operation on voltage supply systems with a non-grounded star point (IT systems). 6 Revision MOVIMOT MM..D with AC Motors DT/DV
Operation Operating notes 4 4 Operation 4.1 Operating notes WARNING Electric shock caused by dangerous voltages at the connections, cables and motor terminals. When the device is switched on, dangerous voltages are present at the connections as well as at any connected cables and motor terminals. This also applies even when the device is inhibited and the motor is at standstill. Severe or fatal injuries. Do not switch under load. Before performing any work on the device, disconnect it from the voltage supply. Note that dangerous voltages can occur at the terminals and connections for up to 1 minute after the controller is switched off. Block the output stage of the inverter before switching at the output of the device. WARNING Electric shock from capacitors that have not been fully discharged. Severe or fatal injuries. Disconnect the inverter from the power. Observe the minimum switch-off time after disconnection from the supply system: 1 minute WARNING Risk of crushing if the motor starts up unintentionally. Severe or fatal injuries Observe the startup instructions. Deactivate all control signals. WARNING Danger of burns due to hot surfaces of the device (e.g. the heat sink). Serious injuries. Do not touch the device until it has cooled down sufficiently. INFORMATION The maximum output frequency in any operating mode is 120 Hz. If the maximum output frequency is exceeded, the status LED of the MOVIMOT inverter flashes slowly red (error 08 "speed monitoring"). Revision MOVIMOT MM..D with AC Motors DT/DV 7
5 Service Inspection and maintenance 5 Service 5.1 Inspection and maintenance 5.1.1 MOVIMOT inverter The MOVIMOT inverter is maintenance-free. SEW EURODRIVE does not prescribe any inspection or maintenance work for the MOVIMOT inverter. Exception: For extended storage, refer to the instructions in the "Service" > "Extended storage" chapter. 5.1.2 Motor The motor requires regular inspection and maintenance work. Observe the notes and instructions in chapter "Inspection/Maintenance" of the motor operating instructions. 5.1.3 Gear units (only for MOVIMOT gearmotors) The gear unit requires regular inspection and maintenance work. Observe the notes and instructions in chapter "Inspection/Maintenance" of the gear unit operating instructions. 5.1.4 Repairs Only SEW-EURODRIVE is authorized to carry out repairs. 8 Revision MOVIMOT MM..D with AC Motors DT/DV
Declaration of conformity 6 6 Declaration of conformity EU Declaration of Conformity Translation of the original text SEW-EURODRIVE GmbH & Co. KG Ernst-Blickle-Straße 42, D-76646 Bruchsal declares under sole responsibility that the following products 900030410/EN Frequency inverters of the product family in accordance with MOVIMOT MM..D-..3-.. MOVIMOT.../MM../... Machinery Directive 2006/42/EC (L 157, 09.06.2006, 24-86) This includes the fulfillment of the protection targets for "electrical power supply" in accordance with annex I No. 1.5.1 according to the Low Voltage Directive 73/23/EEC -- Note: 2014/35/EU is currently valid. EMC Directive 2014/30/EU 4) (L 96, March 29, 2014, 79-106) RoHS Directive Applied harmonized standards: 2011/65/EU (L 174, July 1, 2011, 88-110) EN ISO 13849-1:2008/AC:2009 EN 61800-5-2:2007 EN 61800-5-1:2007 EN 61800-3:2004/A1:2012 EN 50581:2012 4) According to the EMC Directive, the listed products are not independently operable products. EMC assessment is only possible after these products have been integrated in an overall system. For the assessment, the product was installed in a typical plant configuration. Bruchsal Place 20.07.2017 Date Johann Soder Managing Director Technology a) Authorized representative for issuing this declaration on behalf of the manufacturer b) Authorized representative for compiling the technical documents a) b) Revision MOVIMOT MM..D with AC Motors DT/DV 9
SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 76642 BRUCHSAL GERMANY Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com