DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

Similar documents
Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

www. ElectricalPartManuals. com

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

Power Break II Switchboard

Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator

www. ElectricalPartManuals. com Section 6 Low Voltage Power and DC Circuit Breakers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Section 3: Molded Case Circuit Breakers

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

Low Voltage Power Circuit Breakers

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

K-Line Plus Types KP-32, KPE-32, KP-40 and KPE-40

Miniature Circuit Breakers

Controlled Power HSN High Speed DC Circuit Breakers

F.T.M.C. F.T.M.C. Motor Operator For MCCB. MCCB Accessories. Motor Operator. Part No. Frame MOPF240 FTCF F MOPJ240 F FTCJ MOPK240 FTCK

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Operation and Maintenance Manual

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Bolted contact switches. Pringle switches

Evolution * Series E9000 Motor Control Center

30 ma Ground Fault (Earth Leakage) Modules. Product Description

DETAIL SPECIFICATION SHEET

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Medium Voltage Metal-Enclosed Switches

VL Circuit Breaker DG 150A frame

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

www. ElectricalPartManuals. com

Low Voltage Power & Insulated Case Circuit Breakers

Electromagnetic Industries LLP

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

K-Line Plus Type KP-8 thru KP-20

Masterpact NW DC Circuit Breakers

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

a WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

Tmax Molded Case Circuit Breakers

UMBW-UL489 and UL1077 Listed

EntelliGuard Power Circuit Breakers A Frames, Vac. Maintenance Manual

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

I.L. 29C184A File WARNING

Model HEA Multicontact Auxiliary

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

Circuit Breakers Naval Shipboard Use

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

EntelliGuard R Retrofill Application Guide

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5

F-Series. Circuit Breaker

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

F-Series. Circuit Breaker

Magnum IEC Air Circuit Breakers Price List All Prices in US$ for Export Sale

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

WLI Medium Voltage Switchgear Renewal Parts

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

Medium Voltage Metal-Enclosed Switches

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

ches UL File No. E101598

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Magnetic Overload Relays

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Horizontal Circuit Switchers

Transcription:

g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac

Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200 5000 ampere low-voltage power circuit breakers. The listing Qty. Reqd. refers to the quantity of each item required for a three-pole breaker. Renewal parts as furnished may not be identical to the original parts since design changes may have been made in the interim. The parts supplied will, however, be interchangeable with the original parts. Removal of existing parts and assemblies and installation of renewal parts are described in DEH 137, the Maintenance Manual for WavePro 3200 5000 ampere breakers. Covered by This Publication Back Frame Assembly and Components... 1 Front Frame Assembly and Components... 3 Standard Parts and Assemblies Primary Disconnects... 4 Secondary Disconnects... 4 Arc Chutes... 5 Flux Shifter... 5 Current Sensor... 6 Block Fan... 6 Drawout Racking Mechanism... 6 Escutcheon... 7 Accessories Bell Alarm... 7 Shunt Trip... 8 Undervoltage Trip Device... 8 Electric Lockout... 9 Charging Motor... 9 Remote Close... 10 Auxiliary Switch... 10 Open-Fuse Lockout... 11 Remote Charge-Indication Switch... 11 Trip Units, Rating Plugs, Target Modules... 12

Back Frame Assembly and Components Figure 1 shows the Back Frame assembly. Figure 2 shows an Outer Pole Unit, with the additional component added to the Center Pole Unit. Table 1 lists the corresponding catalog numbers. WavePro 3200 5000 Ampere Power Circuit Breakers Figure 2. Outer Pole Unit, with additional component added to Central Pole Unit. Figure 1. Back Frame assembly. Qty. Reqd. WP32 WP40 WP50 Back Frame 1 425D291G38 425D291G39 425D291G40 Pole Unit, Center 1 161D6506G5 161D6506G6 161D6506G6 Pole Unit, Outer 2 161D6506G7 161D6506G8 161D6506G8 Crossbar Assembly 1 139C4412G1 139C4412G1 139C4412G5 Upper Stud Assembly 3 161D6505G1 161D6505G2 161D6505G2 Lower Stud Assembly 3 139C4470G3 139C4470G4 139C4470G4 Table 1. Catalog numbers of the Back Frame and associated components. 1

Figures 3 and 4 are views of the Upper and Lower Stud assemblies. Table 2 lists the catalog numbers for these assemblies, while Table 3 lists the catalog numbers of the individual contacts and springs available as renewal parts. Qty. Reqd. WP32 WP40 WP50 Upper Stud Assembly 3 161D6505G1 161D6505G2 Lower Stud Assembly 3 139C4470G3 139C4470G4 Table 2. Catalog numbers of the Upper and Lower Stud Assemblies. Catalog No. WP32 Qty. Reqd. WP40, WP50 Moving Arcing Contact K9921572G3 9 15 Moving Intermediate Contact (R) 193A1126G7 3 3 Moving Intermediate Contact (L) 193A1126G9 3 Moving Main Contact (L) 193A1126G10 9 9 Moving Main Contact (R) 193A1126G8 6 9 Stationary Arcing Contact 295B408G3 9 15 Stationary Interm. Contact (R) 193A1127G1 3 3 Stationary Interm. Contact (L) 193A1127G2 3 Stationary Main Contact (R) 193A1125G1 6 9 Stationary Main Contact (L) 193A1125G2 9 9 Spring, Arcing Contact, Outer K6509858P1 9 15 Spring, Arcing Contact, Inner K6509859P1 9 15 Spring, Interm. Main Contact 412A288P1 18 24 Figure 3. Upper Stud and Terminal assembly and components. Table 3. Catalog numbers of the individual contacts and springs available for the upper and lower stud assemblies. Figure 4. Lower Stud assembly and moving arcing contacts. 2

Front Frame Assembly and Components The Front Frame Assembly is shown in front view in Figure 5 and in side view in Figure 6. Figure 7 shows the Charging Handle and Assembly. Table 4 lists the corresponding catalog numbers. WavePro 3200 5000 Ampere Power Circuit Breakers Figure 6. Front Frame Assembly from the side. Figure 5. Front Frame Assembly from the front. Front Frame Assembly WP32 WP40 WP50 Charging Handle Assembly Charging Handle 10057262G1 10057262G2 10057262G3 10060171G1 10060167G1 Figure 7. Charging Handle and Assembly. Table 4. Catalog numbers of the Front Frame Assembly and associated components. 3

Standard Parts and Assemblies This section lists the parts and assemblies available as replacements for all WavePro breakers. Primary Disconnects Primary Disconnect assemblies are available in two configurations for the upper and lower disconnects, as illustrated in Figures 8 and 9. Each pole on the lower disconnect requires two assemblies. Each pole on the upper disconnect requires two assemblies and one inner heat sink, with two additional outer heat sinks on the center (B) pole. Catalog numbers are listed in Table 5. Figure 9. Connector assembly for the lower primary disconnect. Qty. Reqd. WP32 WP40, WP50 Primary Disconnect, lower 6 568B450G1 568B450G2 Primary Disconnect, upper 6 139C4549G3 139C4549G4 Heat Sink, inner 3 569B622P3 569B622P4 Heat Sink, outer (phase B only) 2 569B622P1 569B622P2 Table 5. Catalog numbers of the Primary Disconnect renewal parts. Secondary Disconnects The Secondary Disconnect block is illustrated in Figure 10, with the catalog number listed in Table 6. Figure 8. Connector assembly for the upper primary disconnect. Figure 10. Secondary Disconnect. Secondary Disconnect Block Catalog Number 10080736G1 Table 6. Catalog number of the Secondary Disconnect 4

Arc Chutes The Arc Chute is illustrated in Figure 11, with the catalog numbers listed in Table 7. Flux Shifter The Flux Shifter is illustrated in Figure 12, with the catalog numbers listed in Table 8. Figure 11. Arc Chute. Qty. Reqd. WP32 WP40 WP50 Arc Chute 3 242B7020G3 242B7020G4 Table 7. Catalog numbers of the Arc Chutes. Figure 12. Flux Shifter. Qty. Reqd. WP32 WP40 WP50 Flux Shifter 1 425D385G92 425D385G93 Table 8. Catalog numbers of the Flux Shifters. 5

Current Sensor The Current Sensor is illustrated in Figure 13, with the catalog numbers listed in Table 9. Drawout Parts The Drawout Parts are illustrated in Figure 14 and 14A, with the catalog numbers listed in Table 11 and 11A. Figure 13. Current Sensor. Qty. Reqd. Catalog Number Current Sensor, 3200 A 3 139C4970G38 Current Sensor, 4000 A 3 139C4970G39 Current Sensor, 5000 A 3 139C4970G259 Block Fan Table 9. Catalog numbers of the Current Sensors. Renewal parts available for the cooling fans for the 5000 A frame breaker are the fan controller and the fans. The catalog numbers are listed in Table 10. Qty. Reqd. Fan Controller 1 331A3290P1 Fan 2 323A6183P1 Figure 14. Drawout Racking Mechanism. WP32, WP40 WP50 AKD10 OEM AKD10 OEM Racking Mechanism 10080553G1 10080553G2 10080553G3 10080553G4 Table 11. Catalog numbers of the Racking Mechanism renewal parts. Table 10. Catalog numbers of the block fan renewal parts. Figure 14A. Roller and Stud Assembly. WP32, WP40 WP50 AKD10 OEM AKD10 OEM Roller & Stud Assembly 10083673G2 (quantity 4 per breaker) Table 11A. Roller Assembly. 6

Escutcheon The Escutcheon, illustrated in Figure 15, is available in a complete kit including trim and mounting hardware or as the molded cover only. In addition, the Hidden Close Pushbutton and the Trip Unit doors are available separately. The manual charging handle is not included with the Escutcheon. The catalog numbers are listed in Table 12. Accessories This section lists the renewal parts for the optional accessories available with WavePro breakers. Bell Alarm The Bell Alarm accessory, illustrated in Figure 16 can be configured with Automatic Reset or with Lockout. Renewal parts for the Bell Alarm are a complete kit, including mounting hardware, or the module only. The catalog numbers are listed in Table 13. Figure 16. Bell Alarm accessory. Complete Kit Module Only Bell Alarm WPBALF 10080044G1 Figure 15. Escutcheon kit and related parts. Table 13. Catalog numbers of the Bell Alarm renewal parts. Drawing Key 1 2 Escutcheon Kit, complete, AKD-10 Escutcheon Kit, complete, OEM Escutcheon, molded cover only, AKD-10 Escutcheon, molded cover only, OEM Catalog Number 10057276G1 10057276G2 10060207G1 10060207G2 3 Hidden Close Pushbutton WPHIDONKIT1 4 Trip Unit Door, MicroVersaTrip Plus and MicroVersaTrip PM 10060051P1 5 Trip Unit Door, Power+ 10055898G1 Table 12. Catalog numbers of the Escutcheon renewal parts. 7

Shunt Trip The Shunt Trip accessory, illustrated in Figure 17, is available for a variety of control voltage applications. Renewal parts for the Shunt Trip are a complete kit, including mounting hardware, or the module only. A second Shunt Trip may be installed on 3200 and 4000 A frame breakers only. The catalog numbers are listed in Table 14. Undervoltage Trip Device The Undervoltage Trip Device accessory, illustrated in Figure 18, is available for a variety of control voltage applications, with and without Time Delay. Renewal parts for the Undervoltage Trip Device are a complete kit, including mounting hardware, or the module only, with catalog numbers listed in Table 15. The Time Delay unit is available separately with the catalog numbers listed in Table 16. Figure 17. Shunt Trip accessory. Shunt Trip Control Voltage Complete Kit Complete Kit, Shunt Trip 2 Module Only 70 Vac, 60 Hz WPS1LF60070 139C4378G6 120 Vac, 60 Hz WPS1LF60120 WPS2LF60120 139C4378G7 208 Vac, 60 Hz WPS1LF60208 139C4378G10 240 Vac, 60 Hz WPS1LF60240 WPS2LF60240 139C4378G13 120 Vac, 50 Hz WPS1LF50120 139C4378G8 208 Vac, 50 Hz WPS1LF50208 139C4378G11 240 Vac, 50 Hz WPS1LF50240 139C4378G14 12 Vdc WPS1LFDC012 24 Vdc WPS1LFDC024 WPS2LFDC024 139C4378G1 48 Vdc WPS1LFDC048 139C4378G3 110/125 Vdc WPS1LFDC125 WPS2LFDC125 139C4378G4 250 Vdc WPS1LFDC250 WPS2LFDC250 139C4378G5 Table 14. Catalog numbers of the Shunt Trip accessory renewal parts. Figure 18. Undervoltage Trip Device accessory. Undervoltage Trip Control Voltage Complete Kit Module Only 120 Vac WPUVLF56120 10056791G8 240 Vac WPUVLF56240 10056791G9 24 Vdc WPUVLFDC024 10056791G11 48 Vdc WPUVLFDC048 10056791G12 110 Vdc WPUVLFDC110 10056791G13 125 Vdc WPUVLFDC125 10056791G13 250 Vdc WPUVLFDC250 10056791G14 Table 15. Catalog numbers of the Undervoltage Trip Device renewal parts. Undervoltage Trip Control Voltage Undervoltage Kit for use with Static Time Delay Unit* Static Time Delay Unit 125 Vdc WPUVLFTD125 TAKYUVT1 250 Vdc WPUVLFTD250 TAKYUVT2 208/240 Vac WPUVLFTD240 TAKYUVT3 * Static time delay unit is not part of this kit - order separately. Table 16. Catalog numbers for Undervoltage with Time Delay unit. 8

Electric Lockout The Electric Lockout accessory, illustrated in Figure 19, is available for a variety of control voltage applications. Renewal parts for the Electric Lockout are the complete kit, including mounting hardware, and the module only, with the catalog numbers listed in Table 17. Charging Motor The Charging Motor, illustrated in Figure 20, is available for a variety of control voltage applications. Renewal parts for the Charging Motor are the motor and the cut-off switch module. The catalog numbers are listed in Table 18. Figure 20. Charging Motor. Figure 19. Electric Lockout accessory. Electric Lockout Control Voltage Complete Kit Module Only 120 Vac WPELLF56120 10056947G1 240 Vac WPELLF56240 10056947G2 24 Vdc WPELLFDC024 10056947G3 48 Vdc WPELLFDC048 10056947G4 110 Vdc WPELLFDC110 10056947G5 125 Vdc WPELLFDC125 10056947G5 250 Vdc WPELLFDC250 10056947G6 Motor Voltage Motor Cut-Off Switch 110 Vdc, 120 Vac, 125 Vdc 568B596G2 139C4458G1 240 Vac, 250 Vdc 568B596G3 139C4458G1 48 Vdc 568B596G1 139C4458G1 Table 18. Catalog numbers of the Charging Motor renewal parts. Table 17. Catalog numbers of the Electric Lockout renewal parts. 9

Remote Close The Remote Close accessory, illustrated in Figure 21, is available for a variety of control voltage applications. Renewal parts for the Remote Close are the complete kit, the circuit board, and the solenoid. The catalog numbers are listed in Table 19. Auxiliary Switch The Auxiliary Switch accessory, illustrated in Figure 22, is available in two configurations of four or seven stages. The catalog numbers are listed in Table 20. Insulating Barrier Figure 22. Auxiliary Switch accessory. Figure 21. Remote Close accessory. WP32, WP40 WP50 Auxiliary Switch, 4 stage WPAUXLF4STG WPAUXXF4STG Auxiliary Switch, 7 stage WPAUXLF7STG WPAUXXF7STG Table 20. Catalog numbers of the Auxiliary Switch renewal parts. Remote Close Voltage Complete Kit Circuit Board Solenoid 120 Vac, 60 Hz WPRCLF60120 10080367G1 10080505G1 240 Vac, 60 Hz WPRCLF60240 10080367G2 10080505G2 120 Vac, 50 Hz WPRCLF50120 10080367G1 10080505G1 240 Vac, 50 Hz WPRCLF50240 10080367G2 10080505G2 48 Vdc WPRCLFDC048 10080367G5 10080505G3 110 Vdc WPRCLFDC110 10080367G6 10080505G4 125 Vdc WPRCLFDC125 10080367G6 10080505G4 250 Vdc WPRCLFDC250 10080367G6 10080505G5 Table 19. Catalog numbers of the Remote Close renewal parts. 10

Open-Fuse Lockout The Open-Fuse Lockout accessory is illustrated in Figure 23, with the catalog numbers listed in Table 21. Remote Charge-Indication Switch The Remote Charge-Indication Switch is illustrated in Figure 24, with the catalog number listed in Table 22. Figure 24. Remote Charge-Indication Switch. Remote Charge-Indication Switch Catalog Number WPRCILFKIT1 Table 22. Catalog number of the Remote Charge Indication Switch. Figure 23. Open-Fuse Lockout accessory. Open-Fuse Lockout for WP32 Open-Fuse Lockout for WP40, WP50 Catalog Number 121C2870G3 121C2870G4 Table 21. Catalog numbers of the Open-Fuse Lockout. 11

Trip Units, Rating Plugs, Target Modules Power+ Trip Units and MicroVersaTrip Plus and MicroVersaTrip PM Trip Units are available in a large variety of configurations. To order a replacement Trip Unit or Rating Plug for either type or a Target Module for a Power+ Trip Unit, contact GE with the catalog number from the existing unit. 12

g GE Industrial Systems General Electric Company 510 East Agency Road, West Burlington, IA 52655 DEF005 R02 0300 1998 General Electric Company