RAPID SHUTDOWN COMBINER

Similar documents
RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

Product manual Rapid Shutdown (RSD) system for residential and small commercial

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

100A 225A 400A PATENT PENDING

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

i-energy i-micro inverter GT260

Bulletin Wiring methods for solar photovoltaic systems Rules 2-034, , , , , Tables 11 and 19

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

Installation Guide. Trace Combiner Box 6

PV Vault Yielding safety quickly

CP /240-MC4 User Manual

GVB-8 (Boost) Manual

Contactor Combiner Box Installation Manual

PVI 3800TL PVI 5200TL PVI 6600TL PVI 7600TL

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

CPS Energy Balancer. Version: 1.0

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

Installing Power Components

GVB-8 (Boost) Manual

Solar module user manual Conergy PM 225P-250P

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Residential Transition Box. Model RU-1. Specifications. Electrical

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

APPROACHING. The Inverter. 92 IAEI NEWS May.June approaching the inverter

INSTALLATION MANUAL.

Bulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

2016 Photovoltaic Solar System Plan Review List

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

5300 Series Installation Guidelines

PVI 3800TL PVI 5200TL PVI 6600TL PVI 7600TL

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Sunwize Power Ready Express Quick Start

Disconnect Combiner Box Installation Manual

Technical Manual. DLM Module. This manual should remain with the unit.

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

High Frequency SineWave Guardian TM

FRONIUS RAPID SHUTDOWN BOX MOUNTING OPTIONS For Rail and Rail-less systems on L-feet, stand-offs, and other attachment types

BT300 Variable Frequency Drive Bypass

Owner's/Installation Manual

Safety and Installation Instructions

Installation and Operations Manual

Photovoltaic Solar Plan Review

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

Micro3 Grid Tied Residential Package

PHOTOVOLTAIC SYSTEMS

Solar Power Installation Application

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Galaxy VM. Battery Breaker Box Installation 09/

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

GVB-8 (Boost) Manual

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

poollux Power plx-pw60 & plx-pw100

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Operations Manual Pika Harbor Smart Battery

Application Note Three Phase String Inverters NEC 2014 Compliance

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

MOONRING 1.5 MOONRING 3

Cable Cubby 650 UT Installation Guide

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

Residential microinverter system

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

ACI Hoist & Crane. Festoon System. 689 S.W. 7th Terrace Dania, FL (954) Fax (954) Toll Free A-HOIST ( )

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Battery Cables. Wire & Cable

POWER RAIL TM P8. Assembly Instructions. step-by-step assembly and installation. Version 2, Rev A SP PCN

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

SloanLED THINLED. Constant Current. Installation Guide

Specification Grade Contemporary Wall Mount/Technical Installation Data

STREAMLINED SOLAR CHECKLIST Owner Name:

3 Phase Power Systems - Designed for Canada

Solar PV Standard Electrical Plan

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

SAVE THESE INSTRUCTIONS

INSTALLATION AND OPERATOR S MANUAL

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

Cable Cubby 1202 and 1402 Installation Guide

HOYMILES MICRO-IVERTER MI-250

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US

Electrical Installation

PVI 6500 PVI 7500 INSTALLATION AND OPERATION MANUAL. Residential/Commercial Grid Tied Photovoltaic Inverter. 2012, Solectria Renewables, LLC

8300 Series Installation Guidelines

Bulletin Wiring methods for Solar Photovoltaic Systems Rules and , Tables 11 and 19

- Wiring Brochure tekmarnet 4 Thermostat 545

Installation Manual AXITEC SOLAR MODULES

Transcription:

RAPID SHUTDOWN COMBINER Installation and Operation Guide Revision B 2017, Yaskawa Solectria Solar

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. General Safety Information This manual contains important instructions for Solectria s Rapid Shutdown (RSD) Combiner that should be followed during installation and maintenance of the combiner. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Solectria RSD Combiner, follow these instructions. 1.1 Safety and Advisory Symbols DANGER WARNING CAUTION NOTICE DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE indicates a situation that can result in property damage if not avoided. HIGH VOLTAGE WARNING! Indicates hazardous high voltages are present, which, if not avoided, will result in death or serious injury. Only authorized and trained personnel should install and/or maintain this product. Hot surface Equipment grounding conductor Wait for a prescribed amount of time before engaging in the indicated action. 1.2 Safety Instructions CAUTION - Risk of Electric Shock. When the PV array is exposed to light, it supplies a DC voltage to this equipment. CAUTION - Risk of Electric Shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. 2

CAUTION - Risk of electric shock from energy stored in capacitor. Do not remove cover until 5 minutes after disconnecting all sources of supply. WARNING - For continuous protection against risk of fire, replace only with same type and ratings of fuse. WARNING - The RSD Combiner surfaces may become hot. To reduce the risk of burns, do not touch them. PRUDENCE - Quand les panneaux photovoltaque sont exposes a la lumiere, ils fournissent une tension en courant continu a l equipement. PRUDENCE - Le botier ne doit en aucun cas être ouvert. Aucun composant interne n'est à entretenir. Reportezvous à un technicien qualifé pour tout entretien. PRUDENCE - Risque de choc électrique à partir d'énergie stockée dans les condensateurs. Retirer le couvercle AVERTISSEMENT - Du botier au moins 5 minutes après avoir débranché toutes les sources. d'approvisionnement. AVERTISSEMENT- Le chassis de l onduleur et les surfaces des dissipateurs de chaleur peuvent devenir chaud. 2. Rapid Shutdown Combiner The Solectria RSD Combiner provides an automatic disconnect of 600 VDC residential or small commercial PV array systems, fully compliant with the Rapid Shutdown requirements of NEC 2014 article 690.12 when installed appropriately. It is compatible with Solectria s single-phase residential inverters: PVI 3800TL, PVI 5200TL, PVI 6600TL, and PVI 7600TL. Solectria s RSD Combiner must be installed within 10 feet of the PV array when mounted outside or within 5 feet after entering a building in order to comply with NEC 690.12. The RSD Combiner is capable of being mounted to the top of a standard mounting rail beneath a PV module or indoors. Please refer to section 4 for details. The RSD Combiner has two discrete 2 position fused PV string inputs. Each pair of modules combines into a single output where the DC output conductors are routed to the MPPT zone bypass terminals in the PVI single phase inverters. For use with the PVI 3800TL, only one input (2 positives) of the RSD Combiner can be used. For the PVI 5200TL, PVI 6600TL, and PVI 7600TL inverters, all inputs of the RSD combiner should be used. It is acceptable to use only 2 or 3 of the 4 positions based on the PV array design. 3

SOLECTRIA RAPID SHUTDOWN COMBINER ON ROOF WITHIN 10 OF PV Example 1: 2 strings of 260W modules, 12 modules per string and a PVI 5200TL using both MPPT zones (1 string per RSD input). SOLECTRIA RAPID SHUTDOWN COMBINER ON ROOF WITHIN 10 OF PV Examples 2: 3 strings of 260W module, 12 modules per string and a PVI 7600TL using both MPPT zones (1 string on one side and 2 strings on the other). Fig.1 Connection Diagram of Solectria RSD Combiner Always check with the local inspector on wire routing. 4

Equipment Ground Mounting Holes Bracket PV Connector PV Wire Sealing Cap Output Terminal Block Hole Plug Cable Gland Fuse & Fuse Housing M4 Torx Scews 4 5V Signal Terminal Block Ground Stud Inside the Box Hole Plug Fig.2 Front View of Solectria RSD Combiner When the inverter loses utility power, the DC output conductors between the RSD Combiner and the inverter become de-energized below 30V within 10 seconds. The utility power can be cut off at any point upstream of the inverter to allow the contactors to open inside the RSD Combiner, ensuring there is no high voltage DC between the inverter and the RSD Combiner. The PV system with rapid shutdown ability shall be properly labeled according to NEC 690.56 (C). The sign/label should be right at the service entrance and match the sample below (text and color scheme). PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 5

3. Technical Specifications INPUT RATINGS Max. system voltage Max. Number of input circuits 4 Rated input current per string Fuse rating OUTPUT RATINGS Max. Number of output circuits 2 Rated output current per circuit Output Terminal Wire Size Output conduit size 5V signal wire voltage rating 5V signal wire size range GENERAL DATA Enclosure size L x W x D Weight 600V DC 10A DC 15A 20A DC 12-6* AWG ¾ ( two conduits) 600V 24-14 AWG** 12.4 x 10 x 2.2 inches (316 x 255 x 55 mm) 6.6 lbs. (3.0 kg) DC input connectors Amphenol Helios H4 PV connector DC output connectors Operating temperature Storage temperature Humidity Max. operating altitude Warranty STANDARD COMPLIANCE Enclosure protection rating Screw terminal blocks - 40 158 F (-40 70 C) - 40 185 F (-40 85 C) 0 100% (non-condensing) 2000 m above sea level 10 years Type 4X Safety UL 1741, CSA 22.2 107-1 Rapid shutdown NEC 2014 Article 690.12 * When sizing your wires, make sure you comply with all local codes and regulations **Suggested 5V signal wire is unshielded multi conductor type cable PVC insulation with PVC jacket or equivalent 6

4. Dimensions of the RSD Combiner Fig.3 Dimensions of SOLECTRIA RSD Combiner 5. Quick Install Guide WARNING - Do not connect Solectria RSD Combiner to PV string before completing all installation and DC output connection. Once connected to PV string, the RSD Combiner will wake up immediately. Danger! High Voltage. Risk of electric shock. WARNING - Installation and commissioning must be performed by a licensed electrician in accordance with local, state, and National Electrical Code ANSI/NFPA 70 requirements. In Canada, the installation and wiring methods used must comply with the Canadian Electric Code. 7

DANGER -To ensure maximum protection against hazardous voltages while assembling PV installations, both the positive and the negative conductors must be strictly isolated electrically from ground as well as each other. WARNING - Always de-energize the AC branch circuit before servicing. Never disconnect the DC connectors under load. WARNING - Install the RSD Combiner within 10 feet of the array per 2014 NEC requirements. CAUTION - Despite having a Type 4X enclosure with a pollution degree II certification, the RSD Combiner must not be exposed to heavy soiling. CAUTION - Unused connectors and holes must be covered with sealing connectors and plugs. 5.1 Mounting the RSD combiner Fig.4 Mounting SOLECTRIA RSD Combiner Mount the RSD Combiner under the PV module, away from rain and sun. Do not mount the RSD Combiner in a position that allows long-term exposure to direct sunlight or in a vertical orientation that allows water to collect in the DC connector area. Tighten the RSD Combiner fasteners to a torque of 45-50 in-lbs (5 Nm) for 1/4 (6 mm) hardware and 80-85 in-lbs (9 Nm) for 5/16 (8 mm) hardware. Do not over torque. All three mounting locations should be used to support the RSD to the rail. Use suitable hardware for the racking system used. 8

NOTICE - Using a power screwdriver to tighten the mounting hardware is not recommended due to the risk of thread galling. Check that the RSD Combiner is mounted securely on the PV racking. CAUTION - Do not bend the bracket of RSD Combiner. NOTICE - Stainless steel hardware should be used since the RSD combiner is installed outdoors. 5.2 Opening the cover of RSD combiner Remove the 4 M4 cover screws with a T20 Torx screw driver. To replace the cover screws use a torque of 16 in-lbs (1.8 Nm). WARNING - Ensure no live voltages are present on PV input and output circuit before RSD Combiner installation. 5.3 Grounding The Solectria RSD Combiner has an external threaded grounding point for bonding to the racking system. The required equipment ground for this device shall be connected to the threaded grounding point located inside the enclosure. Fig.5 Grounding of Solectria RSD Combiner 9

5.4 Conduit installation and wiring Two conduit plugs are provided for ¾ inch conduit fittings. Remove the conduit plug(s) by placing a flathead screw driver in the slot on the conduit plug face and turning counter-clockwise while gripping the nut on the inside of the enclosure to ensure it does not slip. Unscrew the nut from the conduit plug and slip the conduit plug out of the conduit opening. CAUTION - Do not enlarge the conduit openings as the enclosure will be damaged and will violate the terms of the RSD Combiner warranty. NOTICE - Conduit fittings must be water tight, listed with a Type 4X rating. Once conduit and fittings are installed, route wiring thru conduit and fitting and allowing a 6 inch stain relief/service loop within the RSD Combiner. 5.5 RSD Combiner DC output connections NOTICE - All screw terminals of the DC outputs accept solid or stranded 12-6 AWG copper wire only. Stranded wire is recommended. A 1/8 (3.5 mm) flat head bit is recommended for tightening screw terminals to a torque of 10.5 in-lbs. (1.2 Nm). CAUTION - The rapid shutdown signal wire may be routed together with the DC output cables in the same conduit, but all the cables shall be listed and rated 600 V and use Class 1 wiring methods. Always check with the local AHJ. Although two conductors are enough for the 5V signal wire, AWG 24 4C cable is recommended for the 5V signal wire. The signal wire can be wired with either polarity. Suggested 5V signal wire is unshielded multi conductor type cable PVC insulation with PVC jacket or equivalent. Wire sizes 14-24 AWG acceptable, current draw is 5mA, so there is no concern about voltage drop. 14 AWG stranded THWN-2 wire may be used but smaller jacketed 4-conductor 600V rated and listed wire of 22-24AWG recommended for ease of installation. It is recommended to run redundant signal wires wire (4C conductor) Check with your AHJ on wire choice. 10

Connect DC wire to the DC wiring board And connect 5V signal wire to the AC wiring board of Solectria single-phase PV inverter Note: Redundant wiring is shown for 5V signal wire Fig.6 Terminal Wiring Diagram of Solectria RSD Combiner 11

5.6 PV array string input connections Finally, directly connect the PV strings to the inputs of the RSD Combiner via standard MC-4 style, Ampenol Helios H4 PV or equivalent connectors. CAUTION - Risk of damage. Be sure that the polarity and voltage level is correct when you make the connection. Connecting it incorrectly will cause damage to the equipment. 5.7 PV string fuses Replacement NOTICE - The maximum acceptable string fuse for the RSD Combiner is 20A (KLKD 20). Use of larger fuses will void the warranty. Always replace the string fuse with the same rating and UL/CSA listed PV fuse. 6. Product Warranty and RMA Policy The current warranty and RMA statement for the product is available online at http://www.solectria.com/support/documentation/warranty-information/grid-tiedinverter-warranty-letter/. If you do not have access to the internet or to request a copy to be mailed to you, please contact our Technical Service department 978-683- 9700 x 2. Barcode 12

Appendix A Rapid Shutdown Combiner Data Sheet https://solectria.com/support/documentation/inverter-datasheets/rapidshutdown-combiner-option-for-pvi-3800-7600tl/ Appendix B String Sizing Tool https://solectria.com/support/string-sizing-tool/ Appendix C Contact Information Yaskawa Solectria Solar 360 Merrimack Street Building 9, Floor 2 Lawrence, Massachusetts 01843 USA Tel: 978.683.9700 Fax: 978.683.9702 Sales/General Info: inverters@solectria.com Technical Support & Service: 978-683-9700 x2 Website: www.solectria.com Appendix D Authorized Distributors https://solectria.com/pv-inverters/how-to-buy/ 13

Appendix E UL1741/IEEE1547 Certification Letter 14

15