Installation Manual Retrofitting of the Option "Noise Reduction" SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE

Similar documents
Installation manual AUTOMATIC BACKUP UNIT

Installation Manual SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

Installation Manual 485 Data Module Type B

Multi-Function Interface MULTI-FUNCTION RELAY

Installation Manual SMA POWER CONTROL MODULE

Installation Manual 485 Data Module Type B

Service Manual for Installers SUNNY TRIPOWER 5000TL/6000TL/7000TL/8000TL/9000TL/ 10000TL/12000TL

System description SMA FLEXIBLE STORAGE SYSTEM

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Wind Power Inverter WINDY BOY 5000A/6000A

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Service manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL

Service Manual SUNNY BOY 1300TL/1600TL/2100TL

System Manual MEDIUM VOLTAGE STATION 600 / 1200 / 1800 for SUNNY TRIPOWER 60

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Operating Manual NA-BOX 12

System Monitoring SCHOOLMETERBOX AU

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Accessories for power generation plants in Italy SMA GRID GATE

PV inverter SUNNY MINI CENTRAL 7000HV

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL. SI30M-44M-60H-80H-BE-en-33 Version 3.3 SUNNY REMOTE CONTROL

PV Inverter SUNNY BOY 3300/3800

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Siemens Drives & PLCs

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

User Manual SMA FUEL SAVE CONTROLLER 2.0

Installation - Quick Reference Guide Off-Grid Systems

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

Transportation and Installation Requirements SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function

PV Inverter SUNNY BOY 3300/3800

Exchange of rollers from the XTS-Mover

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

Important. Contents. Contact us:

User Manual SMA FUEL SAVE CONTROLLER 2.0

Installation Manual AUTOMATIC BACKUP UNIT

Type 3320, Service Manual. Serviceanleitung Service Manuel

Charge controller SUNNY ISLAND CHARGER

KeContact P20. User manual

SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation. Connection 4

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

[RENEX] [İstanbul, Ekim 2011]

Operating Manual SUNNY TRIPOWER 15000TL / 20000TL / 25000TL

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Type 3360, Service Manual. Serviceanleitung Service Manuel

Assembly Instructions

Solar module user manual Conergy PM 225P-250P

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

Assembly and Maintenance Manual Type ASNU

ANSI/CSA North America South America Asia. AUS Australia. with Maintenance Information. Second Edition Second Printing Part No.

Assembly and Maintenance Manual Type AS

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

Assembly and Maintenance Manual Type RSBW

Braking Module / braking resistor SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation

Galaxy VM. Battery Breaker Box Installation 09/

Solar PV General Introduction Guide for Electricians

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US

Installation instructions

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

I. Safety precautions

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

SMA Multicluster Technology

Original Operating Manual

Wind Power Inverter WINDY BOY 1200/1700

Single and Double Head Powered Screed. Screed King. User Manual. SCR-UM EN-04 (December 2018)

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

SCOPELITE TIMING LIGHT OPERATING MANUAL

Operation and Maintenance

WATERFLUX 3070 Quick Start

BlinkerBeam SL80 Controller User Guide

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Model Fixed Rack-Mount Kit

Installation instructions

Galaxy Receiving and Unpacking 09/

Rotary feed-through DDF 2

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

PV inverter SUNNY BOY 2100TL

System Monitoring SUNNY SENSORBOX

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Off-Grid Inverter SUNNY ISLAND 4548-US/6048-US

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Assembly Instructions

Central Inverter SUNNY CENTRAL 500U

Wind Power Inverter WINDY BOY 1100LV

Solar Inverter SUNNY BOY 5000US / 6000US / 7000US

Installation instructions

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

SUNNY BOY 2000HF / 2500HF / 3000HF

Transcription:

Installation Manual Retrofitting of the Option "Noise Reduction" SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE ENGLISH SCCPXT-SCS_NR-IA-en-12 98-129600.02 Version 1.2

Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in these documents is the property of SMA Solar Technology AG. Any publication, whether in whole or in part, requires prior written approval by SMA Solar Technology AG. Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not require prior approval. SMA Warranty You can download the current warranty conditions from the Internet at www.sma-solar.com. Trademarks All trademarks are recognized, even if not explicitly identified as such. Missing designations do not mean that a product or brand is not a registered trademark. SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522-0 Fax +49 561 9522-100 www.sma.de Email: info@sma.de Status: 3/15/2018 Copyright 2018 SMA Solar Technology AG. All rights reserved. 2 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this Document... 4 1.1 Validity... 4 1.2 Target Group... 4 1.3 Levels of warning messages... 4 1.4 Symbols in the Document... 5 2 Safety... 6 2.1 Intended Use... 6 2.2 Safety Information... 7 2.3 Personal Protective Equipment... 9 3 Product Overview... 10 3.1 Design of the Inverter... 10 3.2 Type Label... 10 4 Scope of Delivery... 11 5 Preparation for Mounting... 13 5.1 Additionally required mounting material... 13 5.2 Disconnecting the Inverter... 13 6 Mounting... 14 6.1 Safety during Mounting... 14 6.2 Disassembling the Kick Plates... 14 6.3 Removing the Existing Ventilation Plate... 15 6.4 Disassembling the Rear Panel... 16 6.5 Mounting the New Rear Panel... 18 6.6 Mounting the Kick Plate for the Sound Absorber... 19 6.7 Mounting the Ventilation Plate... 19 6.8 Mounting the Kick Plate... 19 6.9 Mounting the Silencing Baffle... 20 7 Switching the Inverter On... 23 8 Dimensions and minimum clearances... 24 8.1 Dimensions of the Inverter... 24 8.2 Minimum Clearances for Outdoor Installation... 24 9 Technical Data... 27 10 Contact... 28 Installation Manual SCCPXT-SCS_NR-IA-en-12 3

1 Information on this Document SMA Solar Technology AG 1 Information on this Document 1.1 Validity This document is a supplement to the provided installation manual of the product and describes the mounting of the accessory parts of the order option "Noise Reduction". This document is valid for the following device types: SC 500CP 10 (Sunny Central 500CP XT) SC 630CP 10 (Sunny Central 630CP XT) SC 720CP 10 (Sunny Central 720CP XT) SC 760CP 10 (Sunny Central 760CP XT) SC 800CP 10 (Sunny Central 800CP XT) SC 850CP 10 (Sunny Central 850CP XT) SC 900CP 10 (Sunny Central 900CP XT) SC 1000CP 10 (Sunny Central 1000CP XT) SCS 500 (Sunny Central Storage 500) SCS 630 (Sunny Central Storage 630) SCS 720 (Sunny Central Storage 720) SCS 760 (Sunny Central Storage 760) SCS 800 (Sunny Central Storage 800) SCS 850 (Sunny Central Storage 850) SCS 900 (Sunny Central Storage 900) SCS 1000 (Sunny Central Storage 1000) Cabinet design (Version 11, V11.1), Manufacturer: BAS Cabinet design V11, Manufacturer: Rittal Illustrations in this document are reduced to the essential and may deviate from the real product. 1.2 Target Group The tasks described in this document must only be performed by qualified persons. Qualified persons must have the following skills: Knowledge of how the product works and is operated Training in how to deal with the dangers and risks associated with installing and using electrical devices and systems Training in the installation and commissioning of electrical devices and systems Knowledge of all applicable standards and directives Knowledge of and adherence to this manual and all safety precautions 1.3 Levels of warning messages The following levels of warning messages may occur when handling the product. DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. 4 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 1 Information on this Document WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a situation which, if not avoided, can result in property damage. 1.4 Symbols in the Document Symbol Explanation Information that is important for a specific topic or goal, but is not safety-relevant Indicates a requirement for meeting a specific goal Desired result A problem that might occur Installation Manual SCCPXT-SCS_NR-IA-en-12 5

2 Safety SMA Solar Technology AG 2 Safety 2.1 Intended Use The assembly of the accessory parts of the order option "Noise Reduction" reduces the noise emission of the product and is suitable for Sunny Central inverters of the CP XT series and Sunny Central Storage battery inverters. After mounting the accessory parts of the order option "Noise Reduction", the enclosure is still complying with the degree of protection IP54. Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives. Any other application may cause personal injury or property damage. Any use of the product other than that described in the Intended Use section does not qualify as the intended use. The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for future reference and observe all instructions contained therein. 6 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 2 Safety 2.2 Safety Information This section contains safety information that must be observed at all times when working on or with the product. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times. DANGER Danger to life from electric shock due to live voltage High voltages are present in the live components of the product. Touching live components results in death or serious injury due to electric shock. Wear suitable personal protective equipment for all work on the product. Do not touch any live components. Observe all warning messages on the product and in the documentation. Observe all safety information of the module manufacturer. After switching off the inverter, wait at least 15 minutes before opening it to allow the capacitors to discharge completely (see Section 5.2, page 13). DANGER Danger to life from electric shock due to live DC cables DC cables connected to PV modules that are exposed to sunlight carry live voltage. Touching live cables results in death or serious injury due to electric shock. Prior to connecting the DC cables, ensure that the DC cables are voltage-free. Wear suitable personal protective equipment for all work on the device. DANGER Danger to life from electric shock due to ground fault If a ground fault has occurred, parts of the PV power plant that are supposedly grounded may in fact be live. Touching incorrectly grounded parts of the PV power plant results in death or serious injuries from electric shock. Before working on the PV power plant, ensure that no ground fault is present. Wear suitable personal protective equipment for all work on the device. DANGER Danger to life from electric shock due to damaged product Operating a damaged product can lead to hazardous situations that result in death or serious injuries due to electric shock. Only operate the product when it is in a flawless technical condition and safe to operate. Check the product regularly for visible damage. Make sure that all external safety equipment is freely accessible at all times. Make sure that all safety equipment is in good working order. Wear suitable personal protective equipment for all work on the product. Installation Manual SCCPXT-SCS_NR-IA-en-12 7

2 Safety SMA Solar Technology AG WARNING Danger to life from electric shock when entering the PV field Ground-fault monitoring does not provide protection from personal injury. PV modules which are grounded with ground-fault monitoring discharge voltage to ground. Entering the PV field can result in lethal electric shocks. Ensure that the insulation resistance of the PV field exceeds the minimum value. The minimum value of the insulation resistance is: 1 kω. Before entering the PV field, switch the PV modules to insulated operation. Configure the PV power plant as a closed electrical operating area. WARNING Danger to life from electric shock if the product is not locked If the product is not locked, unauthorized persons will have access to live components carrying lethal voltages. Touching live components can result in death or serious injury due to electric shock. Always close and lock the product. Remove the keys. Store the keys in a safe place. Ensure that no unauthorized persons have access to the closed electrical operating area. WARNING Danger to life due to blocked escape routes In hazardous situations, blocked escape routes can lead to death or serious injury. Opening the doors of two products located opposite each other can block the escape route. It is imperative that the escape route is freely accessible at all times. An escape route must be available at all times. Make sure the minimum passage width of the escape route meets local standards. Do not place any objects in the escape route area. Remove all tripping hazards from escape routes. CAUTION Risk of burns due to hot components Some components of the product can get very hot during operation. Touching these components can cause burns. Observe the warnings on all components. During operation, do not touch any components marked with such warnings. After switching off the product, wait until any hot components have cooled down sufficiently. Wear suitable personal protective equipment for all work on the product. 8 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 2 Safety NOTICE Property damage due to dust intrusion and moisture penetration Dust or moisture intrusion can damage the product and impair its functionality. Do not open the enclosure during rainfall or when humidity exceeds the specified thresholds. The humidity thresholds are: 15% to 95%. Only perform maintenance work when the environment is dry and free of dust. Operation of the product is only permitted when it is closed. Connect the external supply voltage after mounting and installing the product. If the installation or commissioning process is interrupted, mount all panels. Close and lock the enclosure. The product must always be closed for storage. Store the product in a dry and covered location. Temperature at the storage location must be in the specified range. The temperature range is: 25 C to +70 C. NOTICE Damage to electronic components due to electrostatic discharge Electrostatic discharge can damage or destroy electronic components. Observe the ESD safety regulations when working on the product. Wear suitable personal protective equipment for all work on the product. Discharge electrostatic charge by touching grounded enclosure parts or other grounded elements. Only then is it safe to touch electronic components. 2.3 Personal Protective Equipment Always wear suitable protective equipment When working on the product, always wear the appropriate personal protective equipment for the specific job. The following personal protective equipment is regarded to be the minimum requirement: In a dry environment, safety shoes of category S3 with perforation-proof soles and steel toe caps During precipitation or on moist ground, safety boots of category S5 with perforation-proof soles and steel toe caps Tight-fitting work clothes made of 100% cotton Suitable work pants Individually fitted hearing protection Safety gloves Any other prescribed protective equipment must also be used. Installation Manual SCCPXT-SCS_NR-IA-en-12 9

3 Product Overview SMA Solar Technology AG 3 Product Overview 3.1 Design of the Inverter A B C Figure 1: Design of the Inverter Position A B C Designation Inverter cabinet Interface cabinet Connection area 3.2 Type Label The type label clearly identifies the product. One type label is present in the inverter. The type label is located in the right-hand top corner inside the interface cabinet. You will require the information on the type label to use the product safely and when seeking customer support. The type labels must be permanently attached to the product. Reading off the serial number You can identify the serial number without opening the inverter. The serial number can be found on the roof of the inverter at the top left. You can also read off the serial number from the touch display. Reading Off the Firmware Version You can read off the version number of the inverter and touch display firmware via the user interface. You can also read off the version number of the touch display firmware on the touch display. 10 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 4 Scope of Delivery 4 Scope of Delivery Check the scope of delivery for completeness and any apparent external damage. Contact your distributor if the scope of delivery is incomplete or damaged. Scope of delivery of the silencing baffle A B C D E F Figure 2: Scope of delivery G H I K Position Quantity Designation A 1 Rear panel silencing baffle, including ventilation plate B 1 Silencing baffle cover C 1 Rain shield D 1 Touch-up stick RAL 7035 E 1 Assembly paste (Anti-Seize) F 15 Pan head flange screw G 9 Socket head cap screw H 7 Contact washer I 14 Washer K 10 Hex nut Installation Manual SCCPXT-SCS_NR-IA-en-12 11

4 Scope of Delivery SMA Solar Technology AG Scope of delivery of the kick plate set and rear panel A B C D E Figure 3: Scope of delivery Position Quantity Designation A 1 Inverter rear panel B 1 Kick plate set C 1 Ventilation plate D 1 Assembly paste (Anti-Seize) E 9 Countersunk screw 12 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 5 Preparation for Mounting 5 Preparation for Mounting Provide storage facilities prior to the start of assembly work Storage facilities for the enclosure parts must be provided prior to the start of the assembly work. Make sure that the enclosure parts, seals and screws are not damaged during storage. 5.1 Additionally required mounting material The tools and materials indicated in this section must be provided by the customer. The following tools and materials are required for the assembly work: Torque wrench with TX attachment (TX 30) Torx screwdriver (TX 30) Storage location for enclosure parts (e.g. padded storage cart) Torque wrench (socket wrench size 13) 5.2 Disconnecting the Inverter The inverter must be disconnected prior to the disassembly of the rear panel. DANGER Danger to life from electric shock due to live voltage High voltages are present in the live components of the product. Touching live components results in death or serious injury due to electric shock. Wear suitable personal protective equipment for all work on the product. Observe all warning messages on the product and in the documentation. Switch the inverter off (see inverter installation manual). After switching off the inverter, wait at least 15 minutes before opening it to allow the capacitors to discharge completely. Disconnect the inverter from the voltage source (see inverter installation manual). Installation Manual SCCPXT-SCS_NR-IA-en-12 13

6 Mounting SMA Solar Technology AG 6 Mounting 6.1 Safety during Mounting NOTICE Property damage due to dust intrusion and moisture penetration During assembly work, the inverter is not sufficiently protected against moisture and dust. If the assembly work is carried out during rainfall or in a dusty environment, moisture or dust can penetrate the inverter. Dust or moisture intrusion can damage the product and impair its functionality. Do not open the enclosure during rainfall or when humidity exceeds the specified thresholds. The humidity thresholds are: 15 % to 95 %. Only perform assembly work when the environment is dry and free of dust. NOTICE Inverter failure due to improper storage of the enclosure parts Seals are to be found on the rear side of the enclosure parts. The seals can be damaged if the enclosure parts are incorrectly stored. Weatherproofing of the inverter may be compromised if the seals are damaged. Dust and moisture can penetrate the inverter. Store the enclosure parts properly. Replace damaged seals. 6.2 Disassembling the Kick Plates The kick plates are mounted at the front and rear of the inverter. A B Figure 4: Position of the kick plates Position A B Designation Front kick plate on the inverter Rear kick plate on the inverter 14 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 6 Mounting Requirement: The additionally required mounting material must be available (see Section 5.1, page 13). Procedure: 1. DANGER Danger to life from electric shock due to live voltage Prior to performing any work on the inverter, disconnect it from voltage sources (see inverter installation manual). 2. Loosen the four screws of the left front kick plate (TX 30). Retain the screws for subsequent mounting of the new kick plates. 3. Remove the front kick plate. 4. Loosen the four screws of the right rear kick plate (TX 30). Retain the screws for subsequent mounting of the new kick plates. 5. Remove the rear kick plate. 6. Dispose of the kick plates in accordance with the locally applicable disposal regulations. 6.3 Removing the Existing Ventilation Plate 1. Pull the ventilation plate forwards out of the base area of the inverter cabinet. Grip underneath the ventilation plate and press the middle part up while pulling it out. 2. Dispose of the ventilation plate. Installation Manual SCCPXT-SCS_NR-IA-en-12 15

6 Mounting SMA Solar Technology AG 6.4 Disassembling the Rear Panel A Figure 5: Position of the rear panel to be disassembled Position A Designation Rear panel to be disassembled Requirements: Two persons must be available for disassembling the rear panel. The required mounting material must be available (see Section 5.1, page 13). A storage location for the enclosure parts must be available. The inverter must be sufficiently protected from inclement weather. CAUTION Danger of crushing caused by heavy, bulky rear panel The rear panel of the inverter is heavy and bulky. Danger of crushing when the rear panel slips off or tilts Weight of the roof: 20 kg. Wear suitable personal protective equipment for all work on the product. Always have two persons disassemble and mount the rear panel. Procedure: 1. DANGER Danger to life from electric shock due to live voltage Prior to performing any work on the inverter, disconnect it from voltage sources (see inverter installation manual). 2. Secure the rear panel of the inverter from slipping off. 16 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 6 Mounting 3. Unscrew all ten screws of the rear panel using a suitable screwdriver (TX 30). 10x 4. Remove all screws from the rear panel and retain for later use. 5. Carefully pull the rear panel of the inverter cabinet approx. 80 mm to 100 mm towards you. Make sure that the hook fitting cannot fall out. 6. NOTICE Property damage due to grounding cable being ripped out The rear panel of the inverter and the switch cabinet are connected via a grounding cable. If the rear panel is removed without due care, the grounding cable could be ripped off and the inverter damaged. Use a wrench to release the grounding cable from the rear panel before removing the rear panel (AF 13). 7. Remove the rear panel and store it. Installation Manual SCCPXT-SCS_NR-IA-en-12 17

6 Mounting SMA Solar Technology AG 6.5 Mounting the New Rear Panel Requirements: Two persons must be available for disassembling the rear panel. The required mounting material must be available (see Section 5.1, page 13). The inverter must be sufficiently protected from inclement weather. CAUTION Danger of crushing caused by heavy, bulky rear panel The rear panel of the inverter is heavy and bulky. Danger of crushing when the rear panel slips off or tilts Weight of the roof: 20 kg. Wear suitable personal protective equipment for all work on the product. Always have two persons disassemble and mount the rear panel. Procedure: 1. Position the new rear panel in front of the inverter opening and secure it to prevent it from tipping over. 2. Apply metal-free all-purpose paste to the rear-panel bolt for mounting the grounding cable. 3. Fasten the grounding cable to the rear-panel bolt using a torque wrench (AF 13, torque: 6 Nm). 4. Ensure that the grounding cable is correctly mounted. 5. Apply metal-free all-purpose paste to all threads and set screws. 6. Align the rear panel on the inverter and hook it into the hook fitting. 18 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 6 Mounting 7. Insert the five upper screws of the rear panel into the threads and tighten (TX 30, torque: 8 Nm). 5x 8. Make sure that the rear panel is correctly mounted. 6.6 Mounting the Kick Plate for the Sound Absorber The kick plate must be mounted with an additional air duct on the rear side of the inverter. Procedure: 1. Apply metal-free all-purpose paste to all threads in the base area. 2. Position and align the kick plate for the sound absorber on the enclosure. 3. Screw the previously retained pan head flange screws into the threads. 4. Tighten the pan head flange screws on the kick plate (TX 30, torque: 8 Nm). 6.7 Mounting the Ventilation Plate The guide rails for the ventilation plate are located in the floor area of the inverter cabinet. Procedure: Slide the ventilation plate into the guide rails in the inverter cabinet. The ventilation grid in the ventilation plate should be facing the rear panel. The ventilation plate is flush with the inverter. The ventilation plate will not go all the way in? Grip the ventilation plate from underneath and press the middle part upwards while sliding it in. 6.8 Mounting the Kick Plate A kick plate with an additional noise reduction must be mounted on the front side of the inverter. Procedure: 1. Position and align the kick plate with soundproofing material on the enclosure. 2. Screw the previously retained pan head flange screws into the threads. 3. Tighten the pan head flange screws with a suitable screw driver (TX 30, torque: 8 Nm). Installation Manual SCCPXT-SCS_NR-IA-en-12 19

6 Mounting SMA Solar Technology AG 6.9 Mounting the Silencing Baffle With the order option "Noise reduction", a silencing baffle is delivered with the inverter. The silencing baffle must be mounted on the rear panel of the inverter cabinet. When mounting, use the allround paste from the scope of delivery for the bolted connections. Mounting the rear panel of the silencing baffle Required mounting material: 2 cylindrical screws 2 contact washers Procedure: 1. Remove all screws from the threads for attaching the silencing baffle. 2. Position the rear panel of the silencing baffle on the rear panel of the inverter. 3. Screw two cylindrical screws with contact washers into the middle threads on the rear panel (torque: 8 Nm). Mounting the cover of the silencing baffle Required mounting material: 1 cylindrical screw 3 contact washers 9 pan head flange screws 13 washers 10 hexagon nuts Procedure: 1. Align the lid on the rear panel. Place the cover over the stud bolts. 20 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 6 Mounting 2. Insert a cylindrical screw with contact washer into the top left thread. Do not tighten the screw yet. 3. Screw five pan head flange screws into the upper threads on the cover. Do not tighten the screws yet. 4. Fasten the ventilation plate of the rear panel of the silencing baffle to the cover. Do not yet tighten the four pan head flange screws yet. 5. Screw two hexagon nuts with contact washers onto the bottom right and left stud bolts on the rear panel. 6. Screw all hexagon nuts and washers onto the remaining stud bolts of the rear panel. 7. Align the cover and tighten all screws and nuts (torque: 8 Nm). Installation Manual SCCPXT-SCS_NR-IA-en-12 21

6 Mounting SMA Solar Technology AG Mounting the Rain Shield Required mounting material: 2 cylindrical screws 2 contact washers 6 pan head flange screws Procedure: 1. Position the rain shield on the silencing baffle. 2. Screw two cylindrical screws with contact washers into the bottom right and left threads on the cover and tighten them (torque: 8 Nm). 3. Screw six pan head flange screws into the threads and tighten them (torque: 8 Nm). 22 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 7 Switching the Inverter On 7 Switching the Inverter On Switching the Inverter On Only switch the inverter on in accordance with the information provided in the inverter documentation. Prior to switching the inverter on, ensure that all work has been carried out correctly and that there are no mounting objects left in the inverter. Installation Manual SCCPXT-SCS_NR-IA-en-12 23

8 Dimensions and minimum clearances SMA Solar Technology AG 8 Dimensions and minimum clearances 8.1 Dimensions of the Inverter Mounting the silencing baffle changes the dimensions and safety clearances of the inverter. 956 mm 2562 mm 152 mm 652 mm 2272 mm 700 mm 910 mm 254 mm 1307 mm 1204 mm Figure 6: Dimensions of the inverter with silencing baffle 8.2 Minimum Clearances for Outdoor Installation For the optimum operation of the inverter, observe the following points: The exhaust air vents must not be obstructed or closed. The exhaust air vents must be accessible for cleaning at all times. Minimum clearances for one inverter 220 mm 1200 mm 300 mm 300 mm 300 mm Figure 7: Minimum clearances of the inverter 24 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 8 Dimensions and minimum clearances Minimum clearances for two inverters with mv transformer to be installed outdoors Option 1 Figure 8: Minimum clearance for two inverters with MV transformer Position Designation A Inverter 1 B Inverter 2 C D MV transformer and MV switchgear Cable route between inverter and MV switchgear Installation Manual SCCPXT-SCS_NR-IA-en-12 25

8 Dimensions and minimum clearances SMA Solar Technology AG Option 2 1200 mm 300 mm 500 mm A D 1200 mm C 300 mm B D 1200 mm Figure 9: Minimum clearance for two inverters with MV transformer Position Designation A Inverter 1 B Inverter 2 C D MV transformer and MV switchgear Cable route between inverter and MV switchgear 26 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 9 Technical Data 9 Technical Data The technical data of the product changes when assembling the silencing baffle. Only the technical data that differ from the standard version is shown here. You will find the complete overview of the product's technical data in the installation manual. General Data Width x height x depth Weight 2562 mm x 2272 mm x 1210 mm approx. 1922 kg Noise Emission Product Sunny Central 500CP XT and Sunny Central Storage 500 Sunny Central 630CP XT and Sunny Central Storage 630 Sunny Central 720CP XT and Sunny Central Storage 720 Sunny Central 760CP XT and Sunny Central Storage 760 Sunny Central 800CP XT and Sunny Central Storage 800 Sunny Central 850CP XT and Sunny Central Storage 850 Sunny Central 900CP XT and Sunny Central Storage 900 Sunny Central 1000CP XT and Sunny Central Storage 1000 Noise emission at a distance of 10 m 56 db(a) 57 db(a) 56 db(a) 56 db(a) 56 db(a) 56 db(a) 55 db(a) 60 db(a) Installation Manual SCCPXT-SCS_NR-IA-en-12 27

10 Contact SMA Solar Technology AG 10 Contact If you have technical problems with our products, please contact the SMA Service Line. We require the following information in order to provide you with the necessary assistance: Device type Serial number Type and number of PV modules connected Type of communication Firmware version Error number and error message Deutschland Österreich Schweiz SMA Solar Technology AG Niestetal Sunny Boy, Sunny Mini Central, Sunny Tripower: +49 561 9522 1499 Monitoring Systems (Kommunikationsprodukte): +49 561 9522 2499 Fuel Save Controller (PV-Diesel-Hybridsysteme): +49 561 9522-3199 Sunny Island, Sunny Boy Storage, Sunny Backup: +49 561 9522-399 Sunny Central, Sunny Central Storage: +49 561 9522-299 SMA Online Service Center: www.sma-service.com Belgien Belgique België Luxemburg Luxembourg Nederland Česko Magyarország Slovensko Türkiye SMA Benelux BVBA/SPRL Mechelen +32 15 286 730 SMA Online Service Center: www.sma-service.com SMA Service Partner TERMS a.s. +420 387 6 85 111 SMA Online Service Center: www.sma-service.com SMA Service Partner DEKOM Ltd. Şti. +90 24 22430605 SMA Online Service Center: www.sma-service.com France SMA France S.A.S. Lyon +33 472 22 97 00 SMA Online Service Center : www.sma-service.com Ελλάδα Κύπρος SMA Service Partner AKTOR FM. Αθήνα +30 210 8184550 SMA Online Service Center: www.sma-service.com España Portugal SMA Ibérica Tecnología Solar, S.L.U. Barcelona +34 935 63 50 99 SMA Online Service Center: www.sma-service.com United Kingdom SMA Solar UK Ltd. Milton Keynes +44 1908 304899 SMA Online Service Center: www.sma-service.com Italia SMA Italia S.r.l. Milano +39 02 8934-7299 SMA Online Service Center: www.sma-service.com Australia SMA Australia Pty Ltd. Sydney Toll free for Australia: 1800 SMA AUS (1800 762 287) International: +61 2 9491 4200 28 SCCPXT-SCS_NR-IA-en-12 Installation Manual

SMA Solar Technology AG 10 Contact United Arab Emirates SMA Middle East LLC Abu Dhabi +971 2234 6177 SMA Online Service Center: www.sma-service.com India SMA Solar India Pvt. Ltd. Mumbai +91 22 61713888 ไทย SMA Solar (Thailand) Co., Ltd. กร งเทพฯ +66 2 670 6999 대한민국 SMA Technology Korea Co., Ltd. 서울 +82-2-520-2666 South Africa SMA Solar Technology South Africa Pty Ltd. Cape Town 08600SUNNY (08600 78669) International: +27 (0)21 826 0600 SMA Online Service Center: www.sma-service.com Argentina Brasil Chile Perú SMA South America SPA Santiago de Chile +562 2820 2101 Other countries International SMA Service Line Niestetal 00800 SMA SERVICE (+800 762 7378423) SMA Online Service Center: www.sma-service.com Installation Manual SCCPXT-SCS_NR-IA-en-12 29

www.sma-solar.com