LPQ Series Lighting For Life Featuring the Philips QL Induction Lighting System 100,000 Hours of Operation Very Low Maintenance Efficient Operation The LPQ Series is a luminaire truly designed to provide lighting for life. Lamping options include Philips QL induction lamping system that is certified to provide 100,000 hours of operation. It is the ideal luminaire for parking garages where safety and maintenance are of primary concern. The LPQ with induction lamping is also vibration-resistant because it contains no electrodes to fail due to the rumble of high-volume traffic. LPQ Prism Area lights are recommended for indoor applications where ceiling mounting heights do not exceed 15 feet. It is also a cost-effective replacement fixture for maintenance areas, industrial corridors, wash rooms, storage areas, locker rooms or anywhere safety, maintenance cost and reliability are crucial. The LPQ features a heat-dissipating cast-aluminum housing, corrosion-resistant finish and superior optical components for long-lasting performance. The Right Lighting Solution for Parking Garages The upper refractor ring is designed to redirect 20% of the light upward to the ceiling, eliminating the cavern effect and creating a comfortable, uniform lighting environment. The remainder of the light is redirected down and out below 70 for even, reduced-glare operation.
contractor-friendly features Quick Hang Plate Easy mounting over junction boxes Duraplex II Bronze Polyester Powder Coating Durable finish resists oxidation; other colors available, consult factory Precision Die-Cast Aluminum Housing Heat sink for maximum heat dissipation Die-Formed Heavy Gauge Reflector High-reflectance white polyester powder provides smooth, even illumination Precision Optical System Provides 20% uplighting and redirects light below 70 Acrylic Refractor Standard reduced yellowing virgin acrylic refractor (polycarbonate refractor available) Choice of Lamping Options Long-life induction lamping Energy-efficient compact fluorescent Variety of HID sources Source Comparison QL (85w) CF (42w) MA (175w) HPS (150w) PMA (175w) Lamp Life 100,000 10,000 15,000 24,000 15,000 Lumens Per Watt 70 68 67 85 98 CRI 80 85 65 35 65 Color Shift None None Moderate None Moderate Instant On Yes Yes No No No
The Benefits of Induction lighting The LPQ luminaire is designed to operate with the Philips 55 watt or 85 watt QL Induction Lighting System as well as CF and HID sources. It has been tested and certified by Philips to ensure 100,000 hours of operation. All heat sensitive components have been designed with adequate heat removal and will operate well below the maximum allowed temperature. What is Induction Lighting? The induction lamp operates without an electrode. An induction coil powered by an electronic unit produces a magnetic field in the lamp that ultimately produces light. Since it has no electrode, the lamp does not fail catastrophically as do other lamp sources. Why Induction Lighting? Superior Lighting Quality In terms of color quality, the induction lamp is virtually the same as a good fluorescent lamp. It offers a CRI rating of 80 and has no light loss in cold environments. It also has instant-on and requires no re-strike time unlike HID sources. Cost Effective Alternative to Conventional Sources The LPQ with induction lighting offers huge re-lamping/ maintenance savings over the life of the fixture up to $700.00. System savings can even be greater depending on the difficulty of fixture access and labor cost. Reliable, Durable and Long-Lasting The induction lamp is durable, and light output is not significantly influenced by ambient temperatures. The LPQ with induction lamping is vibration-resistant because it contains no electrodes to fail due to shock or vibration. Equivalent Brightness for Less Energy The induction lamp produces more light in the blue portion of the visible light spectrum, to which the eye is more sensitive at night. In contrast, HPS is stronger in the yellow range where the ability to define details is lost. The Scotopic/ Photopic (S/P) ratio takes this into account to compare the performance of lamp sources. The result is the 85 watt induction lamp has fewer lumens than a 150 watt HPS but offers sufficient lumens for equivalent illumination at night while using 43% less energy. Rated S/P Effective Light Source Lumens Ratio Lumens Quality 85w Induction 6,000 1.62 9,720 Blue 150w HPS 16,000.62 9,920 Yellow LAMP LIFE COMPARISON Life in Hours 100,000 80,000 60,000 40,000 20,000 10,000 0 Source QL CF MA HPS PMA Lighting for Life Because the induction lamp has no filament to burn out, it is rated to operate for 100,000 hours before needing replacement. That translates into 25 years before replacement based on 4,000 hours of annual operation.
Ordering Information LPQ 175 MA L HSK 1 Series Wattage Lamp Source Lamp Options Voltage LPQ 55-55w* Q- Induction* L- Fixtures HSK- Hang 1-120v Lyte Prism 85-85w* furnished straight 2-208v Area Light 232-2x32w with lamps PR- Polycarbonate 3-240v with quick 242-2x42w refractor 4-277v CF- Compact Fluorescent hanger 432-4x32w TP- Tamper proof 5-480v plate for 442-4x42w AMC- Automatic 8-120v J-box 075-70w MA- Metal Halide Standby 75w max. 208v mounting 105-105w NLX- High Pressure Sodium (NPF) Z- Bi-level 240v LPT 155-155w LX- High Pressure Sodium (HX-HPF) JP- Job Pack 277v Lyte Prism 175-175w HLX- High Pressure Sodium (HPF) (consult factory) with Thru- PMA- Pulse Start Metal Halide wiring 3/4 NPS top and sides * 55w and 85w induction source only (100,000-hour life) Accessories 75 4 round cast-aluminum box with four side holes tapped 1/2 NPS for thru-wiring. 753 4 round cast-aluminum box with four side holes tapped 3/4 NPS for thru-wiring. UJB1 Universal junction box 4-1/2 x 4-1/2 x 2 cast-aluminum box with four 3/4 NPS tapped holes on side. HSK Hang straight kit for sloped ceilings or use with pendant. Includes universal junction box (UJB1) and ball and swivel aligner (718S). 3CP15 3C LPQ552 LPQ552PR 3, three conductor approved rubber jacketed 14-3 cable and heavy duty 15 amp twist plug with proper NEMA configuration for specified voltage. Open loop hook for use with UJB1 (order separately) included. 3, three conductor approved rubber jacketed 16-3 cord and open loop hook for use with UJB1 (order separately). Replacement lens kit. Polycarbonate replacement lens. Technical Data 4.5 15 LPQ fixtures are supplied with a medium lamp. All lamps are factory installed in the fixture. Lamp types are E, B or ED17. Ceiling and pendant mounting only. Spacing Ratio: 2.7 12 UL Wet Location Listed UL File Number: E86021
Easy Installation Contractor-Friendly Features for Faster Installation The Quick Hang Plate eliminates the need to open the fixture during installation and is shipped complete with the lamp installed. The contractor simply mounts the Quick Hang Plate to the splice box, pulls the wires through the access hole and hangs the fixture on the provided hook. This allows for fast, hands-free installation without opening the fixture. To complete the installation, the LPQ is rotated upward and locked into place. 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires LPQ0506-10 06/13 Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008