Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Similar documents
Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Servo solenoid valves with on-board electronics (OBE)

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Servo solenoid valves with on-board electronics (OBE)

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with positive overlap and on-board electronics

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Industrial Hydraulics FAQs

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Proportional flow control valve, with inductive position transducer

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Proportional pressure relief valve

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Proportional pressure reducing valve, pilot operated

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve, direct operated, decreasing characteristic curve

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback and on-board electronics

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC ±10 V)

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Electric amplifiers for proportional valves

2-way proportional throttle valve for block installation

Proportional pressure reducing valve, pilot operated

Proportional flow control valve, 2-way version

Pilot operated proportional directional valves

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Proportional pressure reducing valve, pilot operated

Throttle and throttle check valve

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional servo-valve of 4-way design

Supply pressure compensator, direct operated

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure relief valve, directly operated, rising characteristic curve

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

3/3 servo directional control valve with mechanical position feedback

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

3/2 directional spool valve, direct operated with solenoid actuation

Pressure reducing valve, pilot operated

Proportional directional valve, direct operated, with pq functionality

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Proportional flow control valve, with integrated pressure compensator

2/2 directional seat valve, direct operated with solenoid actuation

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Proportional pressure reducing valve, pilot operated

2-way flow control valve

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional pressure relief valve, pilot operated

Pressure relief valve, directly operated

Bourdon tube pressure switch with infinitely variable switching pressure differential

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

2/2-way poppet valves with solenoid operation Type KSDER1

4-way directional servo-valve

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated, with pressure monitoring

3/2 and 4/2 directional seat valves with solenoid actuation

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure relief valve, pilot operated

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure relief valve, pilot operated

Check valve, pilot operated

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Pressure relief valve, pilot operated

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure reducing valve, in 3-way version

Electronic pressure switch with two switching outputs

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Pressure reducing valve, direct operated

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Pressure reducing valve, direct operated

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

4-way directional servo valve Type 4WS.2E

Mating connectors for controlling electrically operated valves and sensors

Directional servo-valve in 4-way design

Check valve, pilot operated

Twin throttle check valve

Pressure relief valve, pilot operated

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Pressure sequence valve, direct operated

Transcription:

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum working pressure A, B, 315 bar, Y 100 bar Nominal flow rate Q nom 980 l/min List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Symbol 2 Function, sectional diagram 3 Technical data 4 to 6 On-board trigger electronics 7 Accessory for external shutdown 8 Characteristic curves 9 and 10 Unit dimensions 11 to 15 Installation dimensions 16 and 17 Features Pilot operated throttle valves with on-board electronics (OBE) and inductive position transducer Design: cartridge type DIN 24342, ISO/DIS 7368 Control oil external and Y Adjustable via the position-controlled main stage by means of the position transducer and on-board electronics Hysteresis < 0.2 %, positioning accuracy > 0.5 %, see Technical data Plug-in connector to DIN 43563-AM6 for the electrical connection, see catalog page RE 08008 (order separately) Data for the on-board trigger electronics Complies with CE, EMC directives EN 61000-6-2: 2002-08 and EN 61000-6-3: 2002-08 U B = 24 V nom DC Electrical connection 6P+PE Signal actuation Standard 0...+10 V (A1) Valve curve calibrated at the factory

2/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Ordering data FES E C A 1 L K0 B1 M * Proportional throttle valve with inductive position transducer (pilot operated) With on-board electronics = E Nominal size = 16 Mounting hole configuration = 25 DIN 24342, ISO/DIS 7368 = 32 = 40 = 50 Connection type (cartridge) Direction of flow A B (customer may implement B A) Unit series 10 to 19 (10 to 19: installation and connection dimensions unchanged) = C = A = 1 K0 = B1 = M = Further information in plain text NBR seals, suitable for mineral oils (HL, HLP) to DIN 51524 Interface for trigger electronics Setpoint input 0.5...+10 V Electrical connection without plug-in connector, with unit plug to DIN 43563-AM6 Order plug-in connector separately L = Flow characteristic Linear 125 = Nominal flow rate 210 = Q nom in l/min 320 = p = 5 bar 500 = 980 = Preferred types Type Material Number FESE16CA 1/125LK0B1M 0 811 402 454 FESE25CA 1/210LK0B1M 0 811 402 517 FESE32CA 1/320LK0B1M 0 811 402 616 FESE40CA 1/500LK0B1M 0 811 402 622 FESE50CA 1/980LK0B1M 0 811 402 642 Symbol For on-board trigger electronics

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 3/18 Function, sectional diagram General Type FESE proportional throttle valves are pilot operated and in cartridge design. This results in their compact form despite high flow rates. The position of the main spool is closed-loop controlled by the on-board electronics (OBE). Hysteresis is < 0.2 %, and a position accuracy of > 0.5 % is achieved. For external valve shutdown (bypassing the valve electronics), the ISA adapter is available as an accessory. This adapter protects the solenoid and the switch contacts during shutdown. EN 61000-6-2: 2002-08 EN 61000-6-3: 2002-08 Basic principle Pilot operated 2/2-way cartridge type valves. There is a free choice of directions of flow, A B or B A, but please note: Always route Y externally Pressure at must always be equal to or greater than at A and not below 12 bar when A B. Pressure at must always be equal to or greater than at B and not below 20 bar when B A. If the valve is shut down electrically and is supplied externally with sufficient pressure at, the main stage A B may be employed as a poppet valve. * Use of 90 plug 1 834 484 252 is preferable, not included in scope of delivery. * Position transducer and on-board electronics Solenoid Pilot valve Y Main stage Tight fit B Accessories Metering edges Type Material Number (4 x) f ISO 4762 Cheese-head bolts included in scope of delivery * Plug-in connectors 2P+PE, KS 1 834 482 022 see also RE 08008 KS 1 834 482 026 MS 1 834 482 023 MS 1 834 482 024 KS 90 1 834 484 252 ISA adapter for external solenoid shutdown, see page 8 1 834 484 245 A Testing and service equipment Test box type VT-PE-TB3, see RE 30065 Measuring adapter 6P+PE type VT-PA-2, see RE 30068

4/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Technical data General Construction Actuation Main stage Cartridge type throttle valve, spool valve with closed-loop position control via OBE Pilot operated, proportional 3/2-way directional control valve in valve cover, without position control Position control via OBE and position transducer LVDT DC/DC Connection type Cartridge type, mounting hole configuration to DIN 24342, ISO/DIS 7368 Mounting position Horizontal if possible, or posifion transducer at the bottom Ambient temperature range C 20...+50 Vibration resistance, test condition Max. 25 g, shaken in 3 dimensions (24 h) Hydraulic (measured with HLP 46, oil = 40 C ±5 C) Pressure fluid Hydraulic oil to DIN 51524...535, other fluids after prior consultation Viscosity range recommended mm 2 /s 20...100 Viskositätsbereich max. permitted mm 2 /s 10...800 Pressure fluid temperature range C 20...+70 Maximum permitted degree of Class 18/16/13 1) contami nation of pressure fluid Purity class to ISO 4406 (c) Direction of flow A B or B A (when supplied internally, or externally when pressure higher) Nominal flow rate at p = 5 bar per edge 2) NG16 NG25 NG32 NG40 NG50 125 210 320 500 980 l/min Weight kg 3.5 4.6 5.8 7.9 10.5 Max. working pressure in A, B, bar 315 315 315 315 315 Max. working pressure in Y bar 100 100 100 100 100 Q max l/min 350 600 1,000 1,500 3,000 Q N pilot valve (supply) l/min 5 15 15 28 28 p = 5 bar Leakage Y cm 3 /min < 150 < 200 < 200 < 400 < 400 Pilot valve at 100 bar Min. flow rate at cm 3 /min 2,000 2,000 3,000 3,000 4,000 U E = 0 V adjustable Valve active ( p = 5 bar) Leakage in main stage at p =100 bar (valve shut down electrically) A B = tight (poppet valve) B A = tight (poppet valve) Note: min. leakage B possible when = external Minimum supply pressure A B bar 12 12 12 12 12 Minimum supply pressure B A bar 20 20 20 20 20 Static/Dynamic Spool stroke/characteristic curve + mm 4 5 7 10 12.5 Overlap on shutdown mm 3 3 3 3 3 Control oil volume of main stage 100 % cm 3 1.02 2.66 6.36 12.57 24.54 Required control oil 0...100 %, l/min 3 5 7 9 9 x = 100 bar Hysteresis % < 0.2 < 0.2 < 0.2 < 0.2 < 0.2 Positioning accuracy % < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 Manufacturing tolerance (Q max ) % ±5 Response time (x = 100 bar) ms Signal change 0...100 % open < 70 < 70 < 90 < 90 < 110 Signal change 100... 0 % close < 70 < 70 < 90 < 130 < 300 Signal change 0... 10 % open < 50 < 50 < 70 < 70 < 80 Signal change 10... 0 % close < 40 < 40 < 50 < 70 < 100 Switch-off behavior U B = OFF or U D E 0.3 V After electrical shutdown (pilot valve opens to the main stage), main stage moves to closed end position Thermal drift < 1 % at T = 40 C Calibration At the factory ±1 %, when U D E = 0.5 V, see characteristic curves

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 5/18 Technical data Electrical, trigger electronics integrated in valve Cyclic duration factor % 100 Degree of protection IP 65 to DIN 40050 and IEC 14434/5 Connection Plug-in connector 6P+PE, DIN 43563 Supply voltage Terminal A: Terminal B: 0 V Power consumption External fuse Input, standard version Terminal D: U D E Terminal E: Max. voltage to differential inputs over 0 V Test signal, standard version Terminal F: U Test Terminal C: Safety earth conductor and shield Recommended cable Calibration A1 24 V DC nom Min. 21 V DC/max. 40 V DC Ripple max. 2 V DC 40 VA max. 2.5 A F Differential amplifier, R i = 100 kω 0...0.5...+10 V (see curve) 0 V D B E B } max. 18 V DC LVDT 0...+10 V Reference 0 V See pin assignment (installation in conformity with CE) See pin assignment up to 20 m 7 x 0.75 mm 2 up to 40 m 7 x 1 mm 2 Calibrated at the factory, see valve curve Conformity EN 61000-6-2: 2002-08 EN 61000-6-3: 2002-08 1) The purity classes stated for the components must be complied with in hydraulic systems. Effective filtration prevents problems and also extends the service life of components. For a selection of filters, see catalog sheets RE 50070, RE 50076 and RE 50081. p 2) Flow for other values of p Q = Q nom 5 Note Rapid shutdown takes place if: The supply voltage 24 V nom (U A B ) drops below 18 V DC The signal setpoint drops below 0.3 V (see characteristic curve). FESE OBE NG 16 50 Supply 24V = Signal: 0 +10 V (valve position) LVDT Signal: 0 +/ 10 V LVDT +/ 10 V Mainstage coverplate 2/2 valve U S Pilotstage 3/2 0 +10 V

6/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Connection For electrical data, see page 7 and Operating Instructions 1 819 929 083 Technical notes for the cable Design: Type: Multi-wire cable Extra-finely stranded wire to VDE 0295, Class 6 Safety earth conductor, green/yellow Cu braided shield e.g. Ölflex-FD 855 CP (from Lappkabel company) No. of wires: Determined by type of valve, plug type and signal assignment Cable Ø: Outside Ø: 0.75 mm 2 up to 20 m long 1.0 mm 2 up to 40 m long 9.4...11.8 mm Pg11 12.7...13.5 mm Pg16 Important Power supply 24 V DC nom., if voltage drops below 18 V DC, rapid shutdown resembling Enable OFF takes place internally. In addition, with the ma signal version: I D E 3 ma valve is active I D E 2 ma valve is deactivated. Electrical signals (e.g. actual values) emitted via the trigger electronics must not be used to shut down safety-relevant machine functions! (Also see European Standard, Technical Safety Requirements for Fluid-Powered Systems and Components Hydraulics, EN 982.)

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 7/18 On-board trigger electronics Circuit diagram/pin assignment Version B1: U D E 0...0.5...+10 V Supply U B Supply zero Ref. zero * Setpoint 0...+10 V Actual value 0...+10 V Safety earth conductor Shield * Do not connect to supply zero! Pin assignment Version B1: U D E 0...0.5...+10 V (R i = 100 kω)

8/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Accessory for external shutdown (ISA adapter) Function Interrupt Safety Adapter, protective circuit and plug connection for external solenoid shutdown (emergency stop circuit). Circuit with ISA adapter Control cabinet Shield on: OBE cable ISA adapter Safety circuit For EMC: shielded cable! Solenoid Pilot valve Note The manufacturer of the complete system is responsible for installation in accordance with EMC guidelines. Symbol Application kg Material Number ISA adapter for Rexroth control solenoids up to 50 VA 0.07 1 834 484 245

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 9/18 Characteristic curves (measured with HLP 46, oil = 40 C ±5 C) p = 5 bar υ = 36 mm 2 /s NG16 NG25 NG32 * Factory setting

10/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Characteristic curves (measured with HLP 46, oil = 40 C ±5 C) p = 5 bar υ = 36 mm 2 /s NG40 NG50 * Factory setting Note The output stage is shut down at U D E < 0.3 V. The valve goes into poppet position. The output stage with position control is switched on at U D E > 0.5 V. The spool position is determined by the setpoint.

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 11/18 Unit dimensions NG16 (nominal dimensions in mm) 15 227 Plug-in connector not included in scope of delivery! 4 x M8x30 ISO 4762 = 30 +10 Nm Included in scope of delivery Set 1 817 010 343 Y 29,5 56 50 127 Ø 25 g6 Ø 32 e9 45 233 65 85 12 See installation dimensions on page 16

12/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Unit dimensions NG25 (nominal dimensions in mm) 15 223 256 12 Plug-in connector not included in scope of delivery! 4 x M12x40 ISO 4762 = 90 +30 Nm Included in scope of delivery Y 39 72 50 127 Set 1 817 010 293 Ø 45 e9 Ø 34 g6 45 249 85 See installation dimensions on page 16

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 13/18 Unit dimensions NG32 (nominal dimensions in mm) 15 224 256 12 Plug-in connector not included in scope of delivery! 4 x M16x50 ISO 4762 = 240 +50 Nm Included in scope of delivery Y 35 85 50 127 Set 1 817 010 294 Ø 45 g6 Ø 60 e9 45 262 102 See installation dimensions on page 16

14/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Unit dimensions NG40 (nominal dimensions in mm) 15 256 12 224 Plug-in connector not included in scope of delivery! 4 x M20x60 ISO 4762 = 450 +100 Nm Included in scope of delivery Y 22 40 105 50 127 Set 1 817 010 295 Ø 55 g6 Ø 75 e9 45 282 See installation dimensions on page 17 125

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 15/18 Unit dimensions NG50 (nominal dimensions in mm) 15 264 12 231 Plug-in connector not included in scope of delivery! 4 x M20x60 ISO 4762 = 450 +100 Nm Included in scope of delivery Set 1 817 010 298 Y 32 47 122 50 127 Ø 67 g6 Ø 90 e9 45 299 See installation dimensions on page 17 140

16/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Installation dimensions DIN 24342, ISO/DIS 7368 (nominal dimensions in mm) NG16 NG25 NG32

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG 17/18 Installation dimensions DIN 24342, ISO/DIS 7368 (nominal dimensions in mm) NG40 NG50

18/18 Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 29216/09.05 FESE Hydraulics Bosch Rexroth AG Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.

Bosch Rexroth AG Hydraulics FESE RE 29216/09.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgement and verification. It must be remembered that our products are subject to a natural process of wear and aging.