ZRV. Direct Operated Check Valve Series ZRV (Denison)

Chapter 7: Sandwich Valves

Pilot-Operated Pressure Relief Valve Series RM

Chapter 5: Flow Valves

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Directional Seat Valve Series D4S (Denison)

Chapter 10: Valves for Pipe Mounting

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Directional Control Valve Series D1VW

Directional Control Valve Series 4D01 (DENISON)

Pilot-Operated Directional Control Valves Series D3 - D11

Chapter 6: Check Valves

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W Soft Shift

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Chapter 6: Check Valves

Chapter 5: Flow Valves

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Directional Control Valve

Double throttle/check valve Type Z2FS B/ (New Series) Huade América 1

Proportional Pressure Relief Valve Series RE*T

Pilot-Operated Proportional DC Valve Series D*1FH

Chapter 2: Directional Control Valves

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Subplates (AP) and multi-station subplates

Pressure Compensated Flow Control Valves SRVR/SRVRP

Accessories Series PSB. Specifications

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

General Specifications DRV DRV-Exm DRV-Exd

Proportional Throttle Valves Series TDL

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Sandwich Valves Series CP

Type of operation Depending on requirement either one or two dry DC-solenoid,

Double throttle check valve Type Z2FS 10

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

Chapter 8: Slip-In Cartridge Valves

Chapter 3: Proportional DC Valves

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

VRN2-10. Functional Description HA /2008. Pilot Operated Pressure Reducing Valves. Replaces HA /2003

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

Chapter 3: Proportional DC Valves

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE

Check-Q-meter type FD

Industrial Valves Check Valve ZW RV / ZW RP - Modular

VPN1-06. Functional Description HA /2008. Pilot Operated Pressure Relief Valves. Replaces HA /2002

Twin throttle check valve

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

Pressure Control Valves. General Description. Specifications. Ordering Information

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

Flow Control Valves and Flow Control Valves with reverse flow check DV/DRV

Pressure relief valve, pilot operated

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Servo solenoid valves with on-board electronics (OBE)

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

Examples 3/2-way valve A T NO: Symbol

Industrial Valves Flow Control Valve ZW SDR - Modular

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

Supply pressure compensator, direct operated

Pressure reducing valve, direct operated

Throttle and throttle check valve

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

VPP2-04. Functional Description HA /2003. Directly operated pressure relief valves. Replaces HA /2002

RC /

Pressure reducing valve, direct operated

2-way flow control valve

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

Servo solenoid valves with on-board electronics (OBE)

NG06. General Size NG6 NG10 Design

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data

Manapak Sandwich Valves. General Description

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

Pressure sequence valve pilot operated

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Throttle and throttle check valve

Transcription:

Characteristics Double-throttle check valves from the Parker Manapak series FM are in sandwich design for easy configuration of stack systems. Throttle and check valves are located in ports A and B. FM2 and FM3 can be used as meter-in or meter-out throttle by changing the mounting position. FM4 can be selected by ordering code as meter-in or meter-out throttle. FM6 is only available as meter-out control. The throttle check valve can also be used to influence the switching time of pilot operated directional valves. In this case, the valve is positioned between the pilot stage (CE- TOP03, NG06) and the main stage (CETOP05, NG10 up to CETOP10, NG32). Features Two types of metering needle design can be selected when ordering FM2 and FM3 valves to achieve the throttle characteristics required to suit the application. Large bypass check valves allow high flow at low pressure drop. Sizes: NG06 / CETOP 3 FM2 NG10 / CETOP 5 FM3 NG16 / CETOP FM4 NG25 / CETOP 8 FM6 Technical data General 2 FM3 FM4 FM6 Size 06 10 16 25 Mounting pattern NFPA D03 NFPA D05 NFPA D0 NFPA D08 CETOP 03 CETOP 05 CETOP0 CETOP 08 Mounting position unrestricted Ambient temperature [ C] -20...+50 MTTF D value [years] 150 Weight [kg] 1.3 2.4 5.4.9 Hydraulic Max. operating pressure [bar] 350 350 350 210 Max. flow [l/min] 53 6 200 341 Opening pressure [bar] 0.3 0.3 0.3 0.3 Meter-in throttle throttle Fluid Hydraulic oil acc.to DIN 51524...525 Fluid temperature [ C] -20...+80 Viscosity range, perm. [cst][mm²/s] 10...650 rec. [cst][mm²/s] 30 Filtration ISO 4406: 18/16/13 (acc. to NAS 1638: ) FM_UK.INDD RH_1.05.10-51

Ordering Code FM DD V Throttle valve Valve size Throttle check valve in the working port A and B Needle design Adjustment Seal FPM Design series (not required for ordering) Code Size 2 NG06 3 NG10 Code K S Adjustment Knob Hex. socket Code omit D Needle Standard conical Fine, cylindrical Hollow bored with V notch A two-stage needle provides fine adjustment in the lower flow range with 3 adjustment rotations. After 3 more rotations, the valve is completely open. Design "D" A cylindrical needle with a V notch allows the fine adjustment over the entire setting range. FM 4 DD V HT Code T F Description Meter-in Throttle valve Valve size NG16 Throttle check valve in the working port A and B / meter-in throttling Seal FPM Design series FM 6 DD K V Throttle valve Valve size NG25 Throttle check valve in the working port A and B Adjusting knob Seal FPM Design series (not required for ordering) FM_UK.INDD RH_1.05.10-52

Performance Curves FM2 standard needle FM2D needle with V notch FM2 flow, check valve FM3 standard needle FM3D needle with V notch FM3 flow, check valve FM_UK.INDD RH_1.05.10 All characteristic curves measured with HLP46 at 50 C. -53

Performance Curves FM4 with standard needle 1 to 5 number of needle rotations FM4 flow, check valve FM6 with standard needle 1 to 5 number of needle rotations FM6 flow, check valve All characteristic curves measured with HLP46 at 50 C. FM_UK.INDD RH_1.05.10-54

Dimensions FM2 Meter-in Valve side Manifold side Meter-in or meter-out A functional change is achieved by rotating the mounting position of the valve 180 about the longitudinal axis (A-B). Seal kit FM2 Seal Order code V SK-FM2-V-20 Note: The O-ring plate (with O-rings) for sealing the connecting surface of the manifold side is included. The O-ring and positioning pin are always mounted on the manifold side. FM_UK.INDD RH_1.05.10-55

Dimensions FM3 Meter-in Meter-in or meter-out A functional change is achieved by rotating the mounting position of the valve 180º about the transverse axis (P). Seal kit FM3 Seal Order code V SK-FM3-V-20 Note: The O-ring plate (with O-rings) for sealing the connecting surface of the manifold side is included. The O-ring and positioning pin are always mounted on the manifold side. FM_UK.INDD RH_1.05.10-56

Dimensions FM4 Meter-in Seal kit FM4 Seal Order code V SK-FM4VHT FM_UK.INDD RH_1.05.10-5

Dimensions FM6 Adjustment: knob Meter-in is not available for FM6 Seal kit FM6 Seal Order code V SK-FM6-V-12 FM_UK.INDD RH_1.05.10-58

Characteristics Throttle Valve with Check Series ZRD (Denison) Throttle check valves series ZRD are designed for maximum flow rates. The throttle check function can be located in port A or BaswellasinA + B.Meter-in or meter-out functionality can be selected by model code. A low flow / high resolution version in NG06 for sensitive shifting time adjustment of pilot operated directional control valves is available on request. ZRD-ABZ01 ZRD-AA02 Features High flow capacity Various functional arrangements Sizes - ZRD01 - NG06 / CETOP3 - ZRD02 - NG10 / CETOP5 - ZRD03 - NG16 / CETOP ZRD-AA02 Technical data General Size 06 10 16 DIN 24340 A6 Mounting interface ISO 4401 NFPA D03 CETOP RP 121 Mounting position unrestricted Ambient temperature [ C] -20...+50 DIN 24340 A10 ISO 4401 NFPA D05 DIN 24340 A16 ISO 4401 NFPA D08 Weight 1 cartridge [kg] 1.2 2.8.4 2 cartridges [kg] 1.3 2.9. Hydraulic Max. operating pressure [bar] 350 315 350 Nominal flow [cst]/[l/min] 80 160 260 Leakage [cst]/[l/min] 0.1...0.2 (at closed throttle) 0.1...0.2 (at closed throttle) 0.3...0.5 (at closed throttle) Opening pressure [bar] 0. 0. 0.8 Fluid Hydraulic oil as per DIN 51524...525 Fluid temperature [ C] -20...+80 Viscosity permitted [cst]/[mm 2 /s] 10...650 Viscosity recommended [cst]/[mm 2 /s] 30 Filtration ISO 4406 (1999) 18/16/13 (acc. NAS 1638: ) ZRD_UK.INDD RH_1.05.10-59

Ordering Code Throttle Valve with Check Series ZRD (Denison) ZRD S0 Throttle valve with check Pressure control Nominal size Hexagon screw with lock nut Design series Seal Code AA AZ BA BZ ABA ABZ Press. control control in A Meter-in control in A control in B Meter-in control in B control in A and B Meter-in control in A and B Ordering code details see end of chapter. Code Seal 1 NBR 5 FPM Code Option C 16 D 06/10 Code Nominal size 01 NG06 02 NG10 03 NG16 ZRD_UK.INDD RH_1.05.10-60

Characteristic Curves Throttle Valve with Check Series ZRD (Denison) p/q performance curves ZRD*01 ZRD*02 ZRD*03 1) Throttle closed All characteristic curves measured with HLP46 at 50 C. ZRD_UK.INDD RH_1.05.10-61

Dimensions Throttle Valve with Check Series ZRD (Denison) ZRD*01 Seal kit Seal Order code 1 098-91096-0 5 098-9109-0 Complete cartridge Order code 098-91119-0 O-ring plate Order code S26-2553-0 ZRD*02 Seal kit Seal Order code 1 098-91098-0 5 098-91099-0 Complete cartridge Order code 098-91120-0 O-ring plate Order code S16-8542-0 ZRD_UK.INDD RH_1.05.10-62

Dimensions Throttle Valve with Check Series ZRD (Denison) ZRD*03 Seal kit Seal Order code 1 098-91442-0 5 098-91443-0 Complete cartridge Order code 098-91441-0 ZRD_UK.INDD RH_1.05.10-63

Ordering Code Details Throttle Valve with Check Series ZRD (Denison) ZRD*01 ZRD*02 ZRD*03 ZRD_UK.INDD RH_1.05.10-64