technical data air conditioning systems RYP-L7/B7 Pair Application Split Sky Air

Similar documents
Split-Sky Air RP-B7 Twin/Triple/Double Twin Application

technical data air conditioning systems RQ-B7 Pair/Twin/Triple/Double Twin Application Split Sky Air

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems MA-GZ7 Multi Model Application Split Sky Air

technical data air conditioning systems RKS-C RKS-B Pair Application, Inverter Controlled Unit Split Sky Air

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

technical data air conditioning systems MXS-B Multi Application Split Sky Air

Outdoor Units R-410A ARX-GV1B

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

Split-Sky Air RMX-JZ Super Multi Plus

Air Conditioning Technical Data RZQG-L(8)Y1

Air Conditioning. Technical Data EEDEN RXZ-N

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

Split-Sky Air FAYP-B Wall Mounted Unit

Air Conditioning. Technical Data EEDEN RXZ-N

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

Air Conditioners Technical Data

1 Features. Outdoor Units R-410A RZQ71-140C7V1B. Split Sky Air Outdoor Units

Air Conditioning Technical Data RZQSG-L3/9V1

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

WCA4**4. Product Specifications

EEDEN technical data. air conditioning systems FDQ-B8V3B9. Split Sky Air

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

technical data air conditioning systems FCQ-D MXS-E 4-way Blow Ceiling Mounted Cassette (edited) Split Sky Air

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

Air Conditioning. Technical Data EEDEN RXJ-L

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

N4A6. Product Specifications

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

CSA6. Product Specifications. SoftSound SXC 2600

1 Features. Indoor Units CONCEALED CEILING UNIT FXSQ-P7VEB. VRV Systems Indoor Units

technical data air conditioning systems 600x600 4-Way Blow Ceiling Mounted Cassette FXZQ-M9V1B

N4A4 C. Product Specifications

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

Technical Service Manual

technical data air conditioning systems FH(Y)C-BZ7/FHYCP-B7 4-Way Blow Ceiling Mounted Cassette Split Sky Air

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Heating Nom. dba Cooling Nom. dba Night quiet mode Level 1 dba Item Tie-wraps Tie-wraps Tie-wraps Tie-wraps

Compact Four-way Cassette Type

HCH6. Product Specifications

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

Tons BTU/h S.E.E.R* E.E.R** HSPF

PHR5. Product Specifications

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

14 SEER, 12 EER PACKAGE AIR CONDITIONER, 2 to 5 TONS 208/ Single Phase

CAC SERIES 12-1/2 Thru 20 Ton

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

technical data Systems FXMQ-MVE Conceiled ceiling unit (large)

Air Conditioners. Technical Data. VRV III heat recovery, with connection to heating only hydrobox REYAQ-P

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

Fan Coil Units. Technical Data

FMU4X, FMC4X FMU4Z, FMC4Z

DESCRIPTION FEATURES

Low Static Pressure Duct(V shape evaporator)

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Air Conditioners. Technical Data. Individual branch selector for VRV heat recovery (Individual BS box) EEDEN BSVQ P8

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

R4H4. Product Specifications

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

FFQN-C, FCRN-E, FFRN-C

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

TSA6. Product Specifications. SmartComfort TXC 5600

Split. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Low Static Pressure Duct (V shape evaporator)

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

Product Data. Features/Benefits. 50SZ SINGLE-PACKAGED HEAT PUMP UNITS 2 to 5 Nominal Tons

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

S/T Ratio. Input BTU/h

Transcription:

technical data RYP-L7/B7 Pair Application air conditioning systems Split Sky Air

Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Specifications are subject to change without prior notice. Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE05-/2 05/2005 Prepared in Belgium by Goekint Graphics

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W TABLE OF CONTENTS RYP-L7/B7 Features... 2 2 Specifications... 3 Technical specifications Electrical specifications 3 Capacity tables... 9 4 Dimensional drawings... 28 5 Operation range... 3 6 Piping diagrams... 32 7 Wiring diagrams... 34 8 Sound level... 37 Sound level data Sound pressure spectrum Accessories... 4 Optional accessories 0 Center of gravity... 43 Safety device settings... 43 2 Installation... 44

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W Features Outdoor units for pair application + Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. + They are fitted with a scroll compressor, renowned for low noise and high energy efficiency. + The piping connections can be accessed from underneath, front, side or rear. + The service valves are hidden inside the casing. + A special acryl precoated fin for anti-corrosion treatment on the heat exchanger ensures greater resistance against severe weather conditions. 2

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 2 Specifications TECHNICAL SPECIFICATIONS OUTDOOR UNITS RYP7L7V/W RYP00L7V/W RYP25L7W RYP200B7W RYP250B7W DIMENSIONS Unit H mm 770,70,220,440 W mm 900 900,290 D mm 320 320 700 WEIGHT kg 80/79 02/0 06 96 20 MATERIAL Unit Painted galvanised steel plate COLOUR Unit Ivory white SOUND LEVEL Sound pressure () high db(a) 50/52 53/56 53/56 57/57 57/57 (cooling/heating) Sound power (2) high db(a) 63 66 67 77/78 77/78 (cooling) FAN Air flow rate (cooling/heating) high m 3 /min 48/43 55/50 89/80 70/- 75/- Speed steps 3 steps step Qty x model xp47ls 2xP47LS xp55jf Qty x motor output W x 65 x 90 85 + 65 x (320+90) HEAT EXCHANGER Type Hi-XSS cooling tube, non sym. waffle fin J8 Hi-XA tube assymetric louvre Rows x stages x fin pitch mm 2 x 34 x 2.0 2 x 52 x 2.0 2 x 52 x 2.0 2 x 40 x 2.0 2 x 50 x 2.0 Face area m 2 0.634 0.983 0.983.57.97 REFRIGERANT CIRCUIT Refrigerant type R-407C Refrigerant charge kg 2.8 3.7 7.5 9.2 Minimum/maximum allowable distance between indoor and outdoor m 5/70 - / 50 (70m equivalent) Maximum allowable level difference m 30 Additional refrigerant charge g/m Please refer to installation 00 g/m for total piping length > 30 m 40 g/m for total piping length > 30 m Refrigerant control Expansion valve (electronic type) Expansion valve COMPRESSOR Type Hermetically sealed scroll type Qty x model xjt90fa-vn xjt25fa-vnx xjt60fa-ye xjt236da-ye@2 xjt300da-ye@2 Motor output x no W 2,200 x 3,000 x 3,750 x 5,500 x 7,500 x Speed rpm - - - 2,900 2,900 Oil type DAPHNE FVC68D Oil charge volume!,200,500 4 4 Crankcase heater W - - - 50 72 PIPING CONNECTIONS liquid mm φ9.5 φ2.7 x 0.90 φ5.9 x 0.95 gas mm φ5.9 φ9. 28.6φ x.5 28.6φ x.5 drain mm φ26x3 26φ x6 26φ x6 INSULATION MATERIAL Heat insulation Both liquid and gas pipes Safety devices High and low pressure switch, thermal protection for indoor and outdoor fan motor, overcurrent relay (compressor), fuse High and low pressure switch, thermal protector for indoor and outdoor fan motor, overcurrent relay (compressor), reverse phase protector, fuse 2 3TW254-B 3TW258-B 3TW2525-A 3TW259-A 3TW2520-A 3TW2363-A 3TW2364-A 3

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 2 Specifications 2 ELECTRICAL SPECIFICATIONS OUTDOOR UNITS RYP7L7V/W RYP00L7V/W RYP25L7W RYP200B7W RYP250B7W CURRENT Nominal running current cooling/heating A Please refer to electrical data 4.4 7.2 Max. running current cooling/heating A Please refer to electrical data Starting current cooling/heating A Please refer to electrical data POWER SUPPLY V/W V/W W W W NOMINAL DISTRIBUTION Phase /3N /3N 3N 3N 3N SYSTEM VOLTAGE Frequency Hz 50 50 50 50 50 Voltage V 230/400 230/400 400 400 400 The sound pressure level is measured in an anechoic room at m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 8 of this chapter. 2 The sound power level is an absolute value indicating the power which a sound source generates. 4

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 2 Specifications ELECTRICAL DATA 2 RYP7L7 Unit combination Power supply Compressor OFM IFM Indoor unit Outdoor unit Hz-Volts Voltage range MCA TOCA MFA LRA RLA kw FLA kw FLA FHYCP7 RYP7L7V 50-230 5. 23.2 32 72. 0.065 0.6 0.045 0.6 FUYP7 RYP7L7V 50-230 4.7 23.2 32 72 0.8 0.065 0.6 0.045 0.6 FHYP7 RYP7L7V 50-230 5.6 23.2 32 72.5 0.065 0.6 0.062 0.6 FHYKP7 RYP7L7V 50-230 Max. 50Hz-264V Min. 50Hz-98V 4.4 23. 32 72 0.6 0.065 0.6 0.045 0.5 FAYP7 RYP7L7V 50/230 4.3 22.9 32 72 0.7 0.065 0.6 0.046 0.3 FHYBP7 RYP7L7V 50-230 4.8 23.5 32 72 0.6 0.065 0.6 0.25 0.9 FDYMP7 RYP7L7V 50-230 4.8 23.5 32 72 0.6 0.065 0.6 0.25 0.9 FHYCP7 RYP7L7W 50-400/230 6.6.2 6 37 4.3 0.065 0.6 0.045 0.6 FUYP7 RYP7L7W 50-400/230 6.5.2 6 37 4.2 0.065 0.6 0.045 0.6 FHYP7 RYP7L7W 50-400/230 6.7.2 6 37 4.4 0.065 0.6 0.062 0.6 FHYKP7 RYP7L7W 50-400/230 Max. 50Hz-440/253V Min. 50Hz-360/97V 6.4. 6 37 4.2 0.065 0.6 0.045 0.5 FAYP7 RYP7L7W 50-400/230 6.2 0.9 6 37 4.2 0.065 0.6 0.046 0.3 FHYBP7 RYP7L7W 50-400/230 6.8.5 6 37 4.2 0.065 0.6 0.25 0.9 FDYMP7 RYP7L7W 50-400/230 6.8.5 6 37 4.2 0.065 0.6 0.25 0.9 3TW2549-2 SYMBOLS MCA : Min. Circuit Amps TOCA : Total Over Current Amps MFA : Max. Fuse Amps (see note 7) LRA : Locked Rotor Amps RLA : Rated Load Amps OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps kw : Rated motor output. RLA is based on the following conditions: Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 35 CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA =.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 6A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 5

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 2 Specifications 2 ELECTRICAL DATA RYP00L7 Unit combination Power supply Compressor OFM IFM Indoor unit Outdoor unit Hz-Volts Voltage range MCA TOCA MFA LRA RLA kw FLA kw FLA FHYCP00 RYP00L7V 50-230 22.7 34.8 40 97 6.7 0.090 0.8 0.090.0 FUYP00 RYP00L7V 50-230 22.3 34.8 40 97 6.4 0.090 0.8 0.090.0 FHYP00 FAYP00 RYP00L7V RYP00L7V 50-230 50-230 Max. 50Hz-264V Min. 50Hz-98V 22.5 22. 34.5 34.2 40 40 97 97 6.8 6.7 0.090 0.090 0.8 0.8 0.30 0.049 0.7 0.4 FHYBP00 RYP00L7V 50-230 22.3 34.8 40 97 6.4 0.090 0.8 0.35.0 FDYMP00 RYP00L7V 50-230 22.4 34.8 40 97 6.5 0.090 0.8 0.35.0 FHYCP00 RYP00L7W 50-400/230 9.3.8 6 47 6.0 0.090 0.8 0.090.0 FUYP00 RYP00L7W 50-400/230 9.3.8 6 47 6.0 0.090 0.8 0.090.0 FHYP00 FAYP00 RYP00L7W RYP00L7W 50-400/230 50-400/230 Max. 50Hz-440/253V Min. 50Hz-360/97V 9.3 8.8.5.2 6 6 47 47 6.2 6. 0.090 0.090 0.8 0.8 0.30 0.049 0.7 0.4 FHYBP00 RYP00L7W 50-400/230 9.3.8 6 47 6.0 0.090 0.8 0.35.0 FDYMP00 RYP00L7W 50-400/230 9.4.8 6 47 6. 0.090 0.8 0.35.0 3TW2559-2 SYMBOLS MCA : Min. Circuit Amps TOCA : Total Over Current Amps MFA : Max. Fuse Amps (see note 7) LRA : Locked Rotor Amps RLA : Rated Load Amps OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps kw : Rated motor output. RLA is based on the following conditions: Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 35 CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA =.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 6A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 6

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 2 Specifications ELECTRICAL DATA 2 RYP25L7 Unit combination Power supply Compressor OFM IFM Indoor unit Outdoor unit Hz-Volts Voltage range MCA TOCA MFA LRA RLA kw FLA kw FLA FHYCP25 RYP25L7W 50-400/230 2.2 5.3 20 59 7.9 0.065 + 0.085 0.6 + 0.7 0.09.0 FUYP25 RYP25L7W 50-400/230.4 5.3 20 59 7.3 0.065 + 0.085 0.6 + 0.7 0.09.0 FHYP25 RYP25L7W 50-400/230 2. 5.0 20 59 8. Max. 50Hz-440/253V Min. 50Hz-360/97V FHYBP25 RYP25L7W 50-400/230 2.0 5.7 20 59 7.4 0.065 + 0.085 0.065 + 0.085 0.6 + 0.7 0.6 + 0.7 0.3 0.7 0.225.4 FDYMP25 RYP25L7W 50-400/230 2.0 5.7 20 59 7.4 0.065 + 0.085 0.6 + 0.7 0.225.4 FDYP25 RYP25L7W 50-400/230 4.8 8.5 20 59 7.4 0.065 + 0.085 0.6 + 0.7 0.5 4.2 3TW25209-2 SYMBOLS MCA : Min. Circuit Amps TOCA : Total Over Current Amps MFA : Max. Fuse Amps (see note 7) LRA : Locked Rotor Amps RLA : Rated Load Amps OFM : Outdoor Fan Motor IFM : Indoor Fan Motor FLA : Full Load Amps kw : Rated motor output. RLA is based on the following conditions: Indoor temp.: 27 CDB/9.5 CWB Outdoor temp. : 35 CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA =.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 6A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 7

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 2 Specifications 2 ELECTRICAL DATA RYP200-250B7 Unit combination Power supply Compressor OFM IFM Indoor unit Outdoor unit Hz-Volts Voltage range MCA MFA LRA RLA kw FLA kw FLA 0.9.28 Min. 360V FDYP200B7V RYP200B7W 50-400 9.0 25 (Outdoor) + 6 (Indoor) 98 2.9 + + 650 6.8 Max. 440V 0.23.43 FDYP250B7V RYP250B7W 50-400 Min. 360V Max. 440V 22.9 32 (Outdoor) + 6 (Indoor) 08 6.0 0.9 + 0.23.28 +.43,000 7.6 3TW236-2 MCA MFA LRA RLA OFM IFM FLA KW SYMBOLS : Min. Circuit Amps : Max. Fuse Amps : Locked Rotor Amps : Rated Load Amps (A) : Outdoor Fan Motor : Indoor Fan Motor : Full Load Amps : Rated motor output (W). RLA is based on the following conditions: Indoor temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 3. Maximum allowable voltage unbalance between phases is 2%. 4. MCA/MFA MCA=.25xRLA+eaFLA MFA=<2.25xRLA+eaFLA (next lower standard fuse rating min 6A) 5. Select wire size based on the larger value of MCA or TOCA 6. Instead of fuse, use circuit breaker 7. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select Daikin Documentation and select conditional connection, the requested product type and English from the drop down lists, click the search button. Finally, click on the document title of your choice. 8

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FHYKP7BV + RYP7L7V RYP7L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.00 6.2 4.9.77 6. 4.8 2.02 5.7 4.7 2.9 5.5 4.6 2.36 5.3 4.5 2.6 4.9 4.2 2.87 4.0 20.00 6.6 4.9.86 6.5 4.8 2. 6.0 4.7 2.28 5.9 4.6 2.36 5.5 4.5 2.6 5.3 4.2 2.87 6.0 22.00 7.2 5.0.86 7.0 4.9 2. 6.5 4.8 2.28 6.3 4.7 2.45 6.0 4.6 2.70 5.5 4.3 2.95 8.0 25.00 7.7 5.2.94 7.5 5.0 2. 7.2 4.9 2.36 6.8 4.8 2.53 6.4 4.6 2.70 6.0 4.5 3.04 9.0 27.00 8.0 5.3.94 7.7 5.2 2. 7.3 5.0 2.36 7. 4.8 2.53 6.6 4.7 2.78 6.2 4.6 3.04 9.5 27.00 8.0 5.3.94 7.9 5.2 2. 7.4 5.0 2.36 7.2 4.8 2.53 6.7 4.7 2.78 6.3 4.6 3.04 22.0 30.00 8.7 5.4 2.02 8.5 5.3 2.9 8.0 5.2 2.45 7.9 4.9 2.6 7.4 4.8 2.78 6.8 4.6 3.2 24.0 32.00 9.4 5.4 2.02 9. 5.3 2.9 8.6 5.2 2.53 8.4 5.0 2.6 8.0 4.8 2.87 7.4 4.6 3.20 3TW2542-7A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FHYKP AFR 7 7 BF 0.07 7. Add the following corrections to power input of each model. Model Supply FHYKP V 0.3 7 W 0 7.5 m 0 m 9

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FHYKP7BV + RYP7L7V RYP7L7W Heating capacity Outdoor 7 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CDB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.7 6.7 2.25 7.4 2.25 8. 2.33 8.6 2.33 - - 8.0 6.3 2.7 6.7 2.25 7.4 2.33 8.0 2.4 8.6 2.4 - - 20.0 6.3 2.33 6.7 2.33 7.3 2.4 8.0 2.49 8.6 2.57 9.3 2.65 22.0 6.3 2.33 6.7 2.4 7.3 2.49 8.0 2.57 8.6 2.57 9. 2.65 24.0 6.3 2.4 6.7 2.49 7.3 2.57 7.9 2.65 8.6 2.65 9. 2.73 3TW2542-3A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FHYKP AFR 7 7 BF 0.07 6. Add the following corrections to power input of each model. Model Supply FHYKP V 0.4 7 W 0 0

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FAYP7-00BV + RYP7-00L7V RYP7-00L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 00 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.0 6.2 4.9.77 6. 4.8 2.02 5.7 4.7 2.9 5.5 4.6 2.36 5.3 4.5 2.6 4.9 4.2 2.87 4.0 20.0 6.6 4.9.86 6.5 4.8 2. 6.0 4.7 2.28 5.9 4.6 2.36 5.5 4.5 2.6 5.3 4.2 2.87 6.0 22.0 7.2 5.0.86 7.0 4.9 2. 6.5 4.8 2.28 6.3 4.7 2.45 6.0 4.6 2.70 5.5 4.3 2.95 8.0 25.0 7.7 5.2.94 7.5 5.0 2. 7.2 4.9 2.36 6.8 4.8 2.53 6.4 4.6 2.70 6.0 4.5 3.04 9.0 27.0 8.0 5.3.94 7.7 5.2 2. 7.3 5.0 2.36 7. 4.8 2.53 6.6 4.7 2.78 6.2 4.6 3.04 9.5 27.0 8.0 5.3.94 7.9 5.2 2. 7.4 5.0 2.36 7.2 4.8 2.53 6.7 4.7 2.78 6.3 4.6 3.04 22.0 30.0 8.7 5.4 2.02 8.5 5.3 2.9 8.0 5.2 2.45 7.9 4.9 2.6 7.4 4.8 2.78 6.8 4.6 3.2 24.0 32.0 9.4 5.4 2.02 9. 5.3 2.9 8.6 5.2 2.53 8.4 5.0 2.6 8.0 4.8 2.87 7.4 4.6 3.20 2.0 8.0 8.4 7.2 2.57 8.3 7. 2.76 8. 6.9 3.4 7.8 6.8 3.33 7.5 6.4 3.7 6.9 6.2 4.09 4.0 20.0 8.9 7.2 2.66 8.8 7. 2.76 8.7 6.9 3.4 8.4 6.8 3.33 7.8 6.4 3.7 7.5 6.2 4.09 6.0 22.0 0. 7.3 2.66 9.8 7.2 2.85 9. 7.0 3.23 8.9 6.9 3.42 8.5 6.5 3.8 7.8 6.3 4.9 8.0 25.0 0.8 7.6 2.66 0.5 7.5 2.85 9.8 7. 3.23 9.6 7.0 3.42 9.0 6.8 3.8 8.4 6.4 4.28 9.0 27.0. 7.7 2.66 0.8 7.6 2.95 0. 7.2 3.33 0.0 7. 3.52 9.4 6.9 3.90 8.7 6.5 4.38 9.5 27.0.2 7.7 2.66.0 7.6 2.95 0.3 7.2 3.33 0. 7. 3.52 9.5 6.9 3.90 8.8 6.5 4.38 22.0 30.0 2.2 7.8 2.76.8 7.7 2.95.2 7.3 3.42.0 7.2 3.62 0.4 7. 4.00 9.6 6.8 4.38 24.0 32.0 3.0 7.9 2.85 2.7 7.8 3.04.9 7.5 3.52.6 7.3 3.7. 7.2 4.09 0.3 6.9 4.47 3TW2542-6A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FAYP AFR 9 7 BF 0. AFR 23 00 BF 0. 7. Add the following corrections to power input of each model. Model Supply FAYP 7 V 0.2 W 0 00 V 0.04 W 0 7.5 m 0 m

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FAYP7-00BV + RYP7-00L7V RYP7-00L7W Heating capacity Outdoor 7 00 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.04 6.7 2. 7.4 2. 8. 2.9 8.6 2.9 - - 8.0 6.3 2.04 6.7 2. 7.4 2.9 8.0 2.26 8.6 2.26 - - 20.0 6.3 2.9 6.7 2.9 7.3 2.26 8.0 2.34 8.6 2.42 9.3 2.49 22.0 6.3 2.9 6.7 2.26 7.3 2.34 8.0 2.42 8.6 2.42 9. 2.49 24.0 6.3 2.26 6.7 2.34 7.3 2.42 7.9 2.49 8.6 2.49 9. 2.57 6.0 8.4 3.08 9. 3.8 0.0 3.27.0 3.37.6 3.47 - - 8.0 8.3 3.8 9.0 3.27 0.0 3.37 0.9 3.47.6 3.56 - - 20.0 8.3 3.37 8.9 3.47 9.8 3.56 0.8 3.66.5 3.76 2.5 3.85 22.0 8.3 3.47 8.9 3.56 9.8 3.66 0.8 3.76.5 3.85 2.4 3.95 24.0 8.2 3.56 8.9 3.66 9.6 3.76 0.6 3.85.3 3.95 2.4 4.05 3TW2542-2A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FAYP AFR 9 7 BF 0. AFR 23 00 BF 0. 6. Add the following corrections to power input of each model. Model Supply FAYP 7 V 0.4 W 0 00 V 0.03 W 0 2

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FHYCP7-25B7V + RYP7-00L7V RYP7-25L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 00 25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.00 6.2 4.8.86 6. 4.7 2.3 5.7 4.6 2.3 5.5 4.5 2.48 5.3 4.4 2.75 4.9 4. 3.0 4.0 20.00 6.6 4.8.95 6.5 4.7 2.22 6.0 4.6 2.39 5.9 4.5 2.48 5.5 4.4 2.75 5.3 4. 3.0 6.0 22.00 7.2 4.9.95 7.0 4.8 2.22 6.5 4.7 2.39 6.3 4.6 2.57 6.0 4.5 2.84 5.5 4.2 3.0 8.0 25.00 7.7 5. 2.04 7.5 4.9 2.22 7.2 4.8 2.48 6.8 4.7 2.66 6.4 4.5 2.84 6.0 4.4 3.9 9.0 27.00 8.0 5.2 2.04 7.7 5. 2.22 7.3 4.9 2.48 7. 4.7 2.66 6.6 4.6 2.93 6.2 4.5 3.9 9.5 27.00 8.0 5.2 2.04 7.9 5. 2.22 7.4 4.9 2.48 7.2 4.7 2.66 6.7 4.6 2.93 6.3 4.5 3.9 22.0 30.00 8.7 5.3 2.3 8.5 5.2 2.3 8.0 5. 2.57 7.9 4.8 2.75 7.4 4.7 2.93 6.8 4.5 3.28 24.0 32.00 9.4 5.3 2.3 9. 5.2 2.3 8.6 5. 2.66 8.4 4.9 2.75 8.0 4.7 3.0 7.4 4.5 3.37 2.0 8.00 8.4 7.0 2.60 8.3 6.9 2.79 8. 6.7 3.8 7.8 6.6 3.37 7.5 6.2 3.75 6.9 6.0 4.4 4.0 20.00 8.9 7.0 2.69 8.8 6.9 2.79 8.7 6.7 3.8 8.4 6.6 3.37 7.8 6.2 3.75 7.5 6.0 4.4 6.0 22.00 0. 7. 2.69 9.8 7.0 2.89 9. 6.8 3.27 8.9 6.7 3.46 8.5 6.3 3.85 7.8 6. 4.23 8.0 25.00 0.8 7.4 2.69 0.5 7.3 2.89 9.8 6.9 3.27 9.6 6.8 3.46 9.0 6.6 3.85 8.4 6.2 4.33 9.0 27.00. 7.5 2.69 0.8 7.4 2.98 0. 7.0 3.37 0.0 6.9 3.56 9.4 6.7 3.94 8.7 6.3 4.43 9.5 27.00.2 7.5 2.69.0 7.4 2.98 0.3 7.0 3.37 0. 6.9 3.56 9.5 6.7 3.94 8.8 6.3 4.43 22.0 30.00 2.2 7.6 2.79.8 7.5 2.98.2 7. 3.46.0 7.0 3.66 0.4 6.9 4.04 9.6 6.6 4.43 24.0 32.00 3.0 7.7 2.89 2.7 7.6 3.08.9 7.3 3.56.6 7. 3.75. 7.0 4.4 0.3 6.7 4.52 2.0 8.00. 9. 3.37 0.8 8.8 3.67 0.0 8.3 3.97 9.7 8.2 4.26 9.2 8.0 4.66 8.6 7.6 5.35 4.0 20.00.8 9. 3.47.4 8.8 3.67 0.7 8.3 4.06 0.4 8.2 4.36 9.8 8.0 4.76 9.2 7.6 5.35 6.0 22.00 2.7 9.2 3.47 2. 8.9 3.77.4 8.4 4.06. 8.3 4.46 0.4 8. 4.86 9.7 7.7 5.45 8.0 25.00 3.3 9.5 3.57 3.0 9. 3.77 2. 8.7 4.6.8 8.6 4.56.2 8.3 4.96 0.4 8.0 5.45 9.0 27.00 3.6 9.6 3.67 3.3 9. 3.87 2.7 8.8 4.26 2.2 8.6 4.56.5 8.4 5.06 0.8 8. 5.55 9.5 27.00 3.8 9.6 3.67 3.5 9. 3.87 2.8 8.8 4.26 2.4 8.7 4.56.7 8.4 5.06.0 8. 5.55 22.0 30.00 5. 9.7 3.77 4.6 9.4 3.87 3.7 9.0 4.36 3.4 8.9 4.66 2.9 8.7 5.5 2.0 8.3 5.75 24.0 32.00 5.9 9.8 3.77 5.5 9.5 3.97 4.6 9. 4.46 4.3 9.0 4.76 3.6 8.8 5.25 2.9 8.6 5.85 3TW2542-A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FHYCP AFR 9 7 BF 0. AFR 28 00 BF 0.6 AFR 33 25 BF 0.07 7. Add the following corrections to power input of each model. Model Supply FHYCP 7 V 0.06 W 0 00 V 0.27 W 0 25 W 0 7.5 m 0 m 3

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FHYCP7-25B7V + RYP7-00L7V RYP7-25L7W Heating capacity Outdoor 7 00 25 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.44 6.7 2.53 7.4 2.53 8. 2.62 8.6 2.62 - - 8.0 6.3 2.44 6.7 2.53 7.4 2.62 8.0 2.7 8.6 2.7 - - 20.0 6.3 2.62 6.7 2.62 7.3 2.7 8.0 2.80 8.6 2.89 9.3 2.98 22.0 6.3 2.62 6.7 2.7 7.3 2.80 8.0 2.89 8.6 2.89 9. 2.98 24.0 6.3 2.7 6.7 2.80 7.3 2.89 7.9 2.98 8.6 2.98 9. 3.07 6.0 8.7 3.08 9.5 3.8 0.3 3.27.4 3.37 2. 3.47 - - 8.0 8.6 3.8 9.4 3.27 0.3 3.37.3 3.47 2. 3.56 - - 20.0 8.6 3.37 9.3 3.47 0. 3.56.2 3.66.9 3.76 2.9 3.85 22.0 8.6 3.47 9.3 3.56 0. 3.66.2 3.76.9 3.85 2.8 3.95 24.0 8.5 3.56 9.3 3.66 9.9 3.76.0 3.85.7 3.95 2.8 4.05 6.0.5 4.22 2.5 4.43 3.4 4.53 4.7 4.64 5.7 4.85 - - 8.0.5 4.32 2.5 4.53 3.4 4.64 4.6 4.85 5.6 4.95 - - 20.0.5 4.53 2.3 4.74 3.4 4.95 4.6 5.06 5.5 5.7 6.7 5.38 22.0.5 4.64 2.3 4.85 3.4 4.95 4.6 5.7 5.5 5.27 6.7 5.48 24.0.3 4.74 2.3 4.95 3.3 5.7 4.5 5.27 5.5 5.48 6.4 5.69 3TW2542-9A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FHYCP AFR 9 7 BF 0.0 AFR 28 00 BF 0.6 AFR 33 25 BF 0.07 6. Add the following corrections to power input of each model. Model Supply FHYCP 7 V 0.05 W 0 00 V 0.09 W 0 25 W 0 4

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FHYBP7-25B7V + RYP7-00L7V RYP7-25L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 00 25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.00 6.2 4.8.8 6. 4.7 2.07 5.7 4.6 2.24 5.5 4.5 2.42 5.3 4.4 2.68 4.9 4. 2.94 4.0 20.00 6.6 4.8.90 6.5 4.7 2.6 6.0 4.6 2.33 5.9 4.5 2.42 5.5 4.4 2.68 5.3 4. 2.94 6.0 22.00 7.2 4.9.90 7.0 4.8 2.6 6.5 4.7 2.33 6.3 4.6 2.50 6.0 4.5 2.76 5.5 4.2 3.02 8.0 25.00 7.7 5..99 7.5 4.9 2.6 7.2 4.8 2.42 6.8 4.7 2.59 6.4 4.5 2.76 6.0 4.4 3. 9.0 27.00 8.0 5.2.99 7.7 5. 2.6 7.3 4.9 2.42 7. 4.7 2.59 6.6 4.6 2.85 6.2 4.5 3. 9.5 27.00 8.0 5.2.99 7.9 5. 2.6 7.4 4.9 2.42 7.2 4.7 2.59 6.7 4.6 2.85 6.3 4.5 3. 22.0 30.00 8.7 5.3 2.07 8.5 5.2 2.24 8.0 5. 2.50 7.9 4.8 2.68 7.4 4.7 2.85 6.8 4.5 3.9 24.0 32.00 9.4 5.3 2.07 9. 5.2 2.24 8.6 5. 2.59 8.4 4.9 2.68 8.0 4.7 2.94 7.4 4.5 3.28 2.0 8.00 8.4 7.0 2.60 8.3 6.9 2.79 8. 6.7 3.8 7.8 6.6 3.37 7.5 6.2 3.75 6.9 6.0 4.4 4.0 20.00 8.9 7.0 2.69 8.8 6.9 2.79 8.7 6.7 3.8 8.4 6.6 3.37 7.8 6.2 3.75 7.5 6.0 4.4 6.0 22.00 0. 7. 2.69 9.8 7.0 2.89 9. 6.8 3.27 8.9 6.7 3.46 8.5 6.3 3.85 7.8 6. 4.23 8.0 25.00 0.8 7.4 2.69 0.5 7.3 2.89 9.8 6.9 3.27 9.6 6.8 3.46 9.0 6.6 3.85 8.4 6.2 4.33 9.0 27.00. 7.5 2.69 0.8 7.4 2.98 0. 7.0 3.37 0.0 6.9 3.56 9.4 6.7 3.94 8.7 6.3 4.43 9.5 27.00.2 7.5 2.69.0 7.4 2.98 0.3 7.0 3.37 0. 6.9 3.56 9.5 6.7 3.94 8.8 6.3 4.43 22.0 30.00 2.2 7.6 2.79.8 7.5 2.98.2 7. 3.46.0 7.0 3.66 0.4 6.9 4.04 9.6 6.6 4.43 24.0 32.00 3.0 7.7 2.89 2.7 7.6 3.08.9 7.3 3.56.6 7. 3.75. 7.0 4.4 0.3 6.7 4.52 2.0 8.00. 9. 3.36 0.8 8.8 3.66 0.0 8.3 3.96 9.7 8.2 4.25 9.2 8.0 4.65 8.6 7.6 5.34 4.0 20.00.8 9. 3.46.4 8.8 3.66 0.7 8.3 4.06 0.4 8.2 4.35 9.8 8.0 4.75 9.2 7.6 5.34 6.0 22.00 2.7 9.2 3.46 2. 8.9 3.76.4 8.4 4.06. 8.3 4.45 0.4 8. 4.85 9.7 7.7 5.44 8.0 25.00 3.3 9.5 3.56 3.0 9. 3.76 2. 8.7 4.5.8 8.6 4.55.2 8.3 4.95 0.4 8.0 5.44 9.0 27.00 3.6 9.6 3.66 3.3 9. 3.86 2.7 8.8 4.25 2.2 8.6 4.55.5 8.4 5.04 0.8 8. 5.54 9.5 27.00 3.8 9.6 3.66 3.5 9. 3.86 2.8 8.8 4.25 2.4 8.7 4.55.7 8.4 5.04.0 8. 5.54 22.0 30.00 5. 9.7 3.76 4.6 9.4 3.86 3.7 9.0 4.35 3.4 8.9 4.65 2.9 8.7 5.4 2.0 8.3 5.74 24.0 32.00 5.9 9.8 3.76 5.5 9.5 3.96 4.6 9. 4.45 4.3 9.0 4.75 3.6 8.8 5.24 2.9 8.6 5.84 3TW2542-2A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FHYBP AFR 9 7 BF 0. AFR 27 00 BF 0.2 AFR 35 25 BF 0.4 7. Add the following corrections to power input of each model. Model Supply FHYBP 7 V 0.06 W 0 00 V 0.22 W 0 25 W 0 7.5 m 0 m 5

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FHYBP7-25B7V + RYP7-00L7V RYP7-25L7W Heating capacity Outdoor 7 00 25 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.7 6.7 2.25 7.4 2.25 8. 2.33 8.6 2.33 - - 8.0 6.3 2.7 6.7 2.25 7.4 2.33 8.0 2.4 8.6 2.4 - - 20.0 6.3 2.33 6.7 2.33 7.3 2.4 8.0 2.49 8.6 2.57 9.3 2.65 22.0 6.3 2.33 6.7 2.4 7.3 2.49 8.0 2.57 8.6 2.57 9. 2.65 24.0 6.3 2.4 6.7 2.49 7.3 2.57 7.9 2.65 8.6 2.65 9. 2.73 6.0 8.7 3.26 9.5 3.36 0.3 3.46.4 3.56 2. 3.67 - - 8.0 8.6 3.36 9.4 3.46 0.3 3.56.3 3.67 2. 3.77 - - 20.0 8.6 3.56 9.3 3.67 0. 3.77.2 3.87.9 3.97 2.9 4.07 22.0 8.6 3.67 9.3 3.77 0. 3.87.2 3.97.9 4.07 2.8 4.8 24.0 8.5 3.77 9.3 3.87 9.9 3.97.0 4.07.7 4.8 2.8 4.28 6.0.4 3.77 2.4 3.96 3.4 4.05 4.6 4.4 5.5 4.33 - - 8.0.4 3.86 2.4 4.05 3.4 4.4 4.5 4.33 5.5 4.43 - - 20.0.4 4.05 2.2 4.24 3.3 4.43 4.5 4.52 5.4 4.6 6.6 4.80 22.0.4 4.4 2.2 4.33 3.3 4.43 4.5 4.6 5.4 4.7 6.6 4.90 24.0.3 4.24 2.2 4.43 3.2 4.6 4.4 4.7 5.4 4.90 6.3 5.09 3TW2542-0A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FHYBP AFR 9 7 BF 0. AFR 27 00 BF 0.2 AFR 35 25 BF 0.4 6. Add the following corrections to power input of each model. Model Supply FHYBP 7 V 0 W 0 00 V 0.04 W 0 25 W 0 6

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FHYP7-25BV + RYP7-00L7V RYP7-25L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 00 25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.00 6.2 4.8.86 6. 4.7 2.2 5.7 4.6 2.30 5.5 4.5 2.47 5.3 4.4 2.74 4.9 4. 3.00 4.0 20.00 6.6 4.8.94 6.5 4.7 2.2 6.0 4.6 2.39 5.9 4.5 2.47 5.5 4.4 2.74 5.3 4. 3.00 6.0 22.00 7.2 4.9.94 7.0 4.8 2.2 6.5 4.7 2.39 6.3 4.6 2.56 6.0 4.5 2.83 5.5 4.2 3.09 8.0 25.00 7.7 5. 2.03 7.5 4.9 2.2 7.2 4.8 2.47 6.8 4.7 2.65 6.4 4.5 2.83 6.0 4.4 3.8 9.0 27.00 8.0 5.2 2.03 7.7 5. 2.2 7.3 4.9 2.47 7. 4.7 2.65 6.6 4.6 2.92 6.2 4.5 3.8 9.5 27.00 8.0 5.2 2.03 7.9 5. 2.2 7.4 4.9 2.47 7.2 4.7 2.65 6.7 4.6 2.92 6.3 4.5 3.8 22.0 30.00 8.7 5.3 2.2 8.5 5.2 2.30 8.0 5. 2.56 7.9 4.8 2.74 7.4 4.7 2.92 6.8 4.5 3.27 24.0 32.00 9.4 5.3 2.2 9. 5.2 2.30 8.6 5. 2.65 8.4 4.9 2.74 8.0 4.7 3.00 7.4 4.5 3.36 2.0 8.00 8.4 7.0 2.66 8.3 6.9 2.86 8. 6.7 3.26 7.8 6.6 3.45 7.5 6.2 3.85 6.9 6.0 4.24 4.0 20.00 8.9 7.0 2.76 8.8 6.9 2.86 8.7 6.7 3.26 8.4 6.6 3.45 7.8 6.2 3.85 7.5 6.0 4.24 6.0 22.00 0. 7. 2.76 9.8 7.0 2.96 9. 6.8 3.35 8.9 6.7 3.55 8.5 6.3 3.95 7.8 6. 4.34 8.0 25.00 0.8 7.4 2.76 0.5 7.3 2.96 9.8 6.9 3.35 9.6 6.8 3.55 9.0 6.6 3.95 8.4 6.2 4.44 9.0 27.00. 7.5 2.76 0.8 7.4 3.06 0. 7.0 3.45 0.0 6.9 3.65 9.4 6.7 4.04 8.7 6.3 4.54 9.5 27.00.2 7.5 2.76.0 7.4 3.06 0.3 7.0 3.45 0. 6.9 3.65 9.5 6.7 4.04 8.8 6.3 4.54 22.0 30.00 2.2 7.6 2.86.8 7.5 3.06.2 7. 3.55.0 7.0 3.75 0.4 6.9 4.4 9.6 6.6 4.54 24.0 32.00 3.0 7.7 2.96 2.7 7.6 3.6.9 7.3 3.65.6 7. 3.85. 7.0 4.24 0.3 6.7 4.64 2.0 8.00. 9. 3.30 0.8 8.8 3.59 0.0 8.3 3.88 9.7 8.2 4.7 9.2 8.0 4.56 8.6 7.6 5.24 4.0 20.00.8 9. 3.39.4 8.8 3.59 0.7 8.3 3.98 0.4 8.2 4.27 9.8 8.0 4.65 9.2 7.6 5.24 6.0 22.00 2.7 9.2 3.39 2. 8.9 3.68.4 8.4 3.98. 8.3 4.36 0.4 8. 4.75 9.7 7.7 5.33 8.0 25.00 3.3 9.5 3.49 3.0 9. 3.68 2. 8.7 4.07.8 8.6 4.46.2 8.3 4.85 0.4 8.0 5.33 9.0 27.00 3.6 9.6 3.59 3.3 9. 3.78 2.7 8.8 4.7 2.2 8.6 4.46.5 8.4 4.94 0.8 8. 5.43 9.5 27.00 3.8 9.6 3.59 3.5 9. 3.78 2.8 8.8 4.7 2.4 8.7 4.46.7 8.4 4.94.0 8. 5.43 22.0 30.00 5. 9.7 3.68 4.6 9.4 3.78 3.7 9.0 4.27 3.4 8.9 4.56 2.9 8.7 5.04 2.0 8.3 5.62 24.0 32.00 5.9 9.8 3.68 5.5 9.5 3.88 4.6 9. 4.36 4.3 9.0 4.65 3.6 8.8 5.4 2.9 8.6 5.72 3TW2542-4A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FHYP AFR 7 7 BF 0. AFR 24 00 BF 0.4 AFR 30 25 BF 0.3 7. Add the following corrections to power input of each model. Model PI FHYP 7 V 0.05 W 0 00 V 0.03 W 0 25 W 0 7.5 m 0 m 7

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FHYP7-25BV + RYP7-00L7V RYP7-25L7W Heating capacity Outdoor 7 00 25 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.44 6.7 2.53 7.4 2.53 8. 2.62 8.6 2.62 - - 8.0 6.3 2.44 6.7 2.53 7.4 2.62 8.0 2.7 8.6 2.7 - - 20.0 6.3 2.62 6.7 2.62 7.3 2.7 8.0 2.80 8.6 2.89 9.3 2.98 22.0 6.3 2.62 6.7 2.7 7.3 2.80 8.0 2.89 8.6 2.89 9. 2.98 24.0 6.3 2.7 6.7 2.80 7.3 2.89 7.9 2.98 8.6 2.98 9. 3.07 6.0 8.5 3.24 9.3 3.34 0. 3.44.2 3.55.9 3.65 - - 8.0 8.4 3.34 9.2 3.44 0. 3.55. 3.65.9 3.75 - - 20.0 8.4 3.55 9. 3.65 0.0 3.75.0 3.85.7 3.95 2.7 4.05 22.0 8.4 3.65 9. 3.75 0.0 3.85.0 3.95.7 4.05 2.6 4.5 24.0 8.3 3.75 9. 3.85 9.8 3.95 0.8 4.05.5 4.5 2.6 4.26 6.0. 4.6 2.0 4.37 2.9 4.47 4. 4.57 5.0 4.78 - - 8.0. 4.26 2.0 4.47 2.9 4.57 4.0 4.78 4.9 4.89 - - 20.0. 4.47.8 4.68 2.8 4.89 4.0 4.99 4.8 5.09 6.0 5.30 22.0. 4.57.8 4.78 2.8 4.89 4.0 5.09 4.8 5.20 6.0 5.4 24.0 0.9 4.68.8 4.89 2.7 5.09 3.9 5.20 4.8 5.4 5.8 5.6 3TW2542-8A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FHYP AFR 7 7 BF 0.0 AFR 24 00 BF 0.4 AFR 30 25 BF 0.3 6. Add the following corrections to power input of each model. Model Supply FHYP 7 V 0.05 W 0 00 V 0.05 W 0 25 W 0 8

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FUYP7-25BV + RYP7-00L7V RYP7-25L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 00 25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.00 6.2 4.9.86 6. 4.8 2.2 5.7 4.7 2.30 5.5 4.6 2.47 5.3 4.5 2.74 4.9 4.2 3.00 4.0 20.00 6.6 4.9.94 6.5 4.8 2.2 6.0 4.7 2.39 5.9 4.6 2.47 5.5 4.5 2.74 5.3 4.2 3.00 6.0 22.00 7.2 5.0.94 7.0 4.9 2.2 6.5 4.8 2.39 6.3 4.7 2.56 6.0 4.6 2.83 5.5 4.3 3.09 8.0 25.00 7.7 5.2 2.03 7.5 5.0 2.2 7.2 4.9 2.47 6.8 4.8 2.65 6.4 4.6 2.83 6.0 4.5 3.8 9.0 27.00 8.0 5.3 2.03 7.7 5.2 2.2 7.3 5.0 2.47 7. 4.8 2.65 6.6 4.7 2.92 6.2 4.6 3.8 9.5 27.00 8.0 5.3 2.03 7.9 5.2 2.2 7.4 5.0 2.47 7.2 4.8 2.65 6.7 4.7 2.92 6.3 4.6 3.8 22.0 30.00 8.7 5.4 2.2 8.5 5.3 2.30 8.0 5.2 2.56 7.9 4.9 2.74 7.4 4.8 2.92 6.8 4.6 3.27 24.0 32.00 9.4 5.4 2.2 9. 5.3 2.30 8.6 5.2 2.65 8.4 5.0 2.74 8.0 4.8 3.00 7.4 4.6 3.36 2.0 8.00 8.4 7.2 2.76 8.3 7. 2.96 8. 6.9 3.37 7.8 6.8 3.58 7.5 6.4 3.98 6.9 6.2 4.39 4.0 20.00 8.9 7.2 2.86 8.8 7. 2.96 8.7 6.9 3.37 8.4 6.8 3.58 7.8 6.4 3.98 7.5 6.2 4.39 6.0 22.00 0. 7.3 2.86 9.8 7.2 3.06 9. 7.0 3.47 8.9 6.9 3.68 8.5 6.5 4.09 7.8 6.3 4.50 8.0 25.00 0.8 7.6 2.86 0.5 7.5 3.06 9.8 7. 3.47 9.6 7.0 3.68 9.0 6.8 4.09 8.4 6.4 4.60 9.0 27.00. 7.7 2.86 0.8 7.6 3.7 0. 7.2 3.58 0.0 7. 3.78 9.4 6.9 4.9 8.7 6.5 4.70 9.5 27.00.2 7.7 2.86.0 7.6 3.7 0.3 7.2 3.58 0. 7. 3.78 9.5 6.9 4.9 8.8 6.5 4.70 22.0 30.00 2.2 7.8 2.96.8 7.7 3.7.2 7.3 3.68.0 7.2 3.88 0.4 7. 4.29 9.6 6.8 4.70 24.0 32.00 3.0 7.9 3.06 2.7 7.8 3.27.9 7.5 3.78.6 7.3 3.98. 7.2 4.39 0.3 6.9 4.80 2.0 8.00. 9.5 3.34 0.8 9.2 3.64 0.0 8.7 3.93 9.7 8.6 4.23 9.2 8.4 4.62 8.6 8.0 5.3 4.0 20.00.8 9.5 3.44.4 9.2 3.64 0.7 8.7 4.03 0.4 8.6 4.32 9.8 8.4 4.72 9.2 8.0 5.3 6.0 22.00 2.7 9.6 3.44 2. 9.3 3.73.4 8.8 4.03. 8.7 4.42 0.4 8.5 4.8 9.7 8. 5.40 8.0 25.00 3.3 9.9 3.54 3.0 9.5 3.73 2. 9. 4.3.8 9.0 4.52.2 8.7 4.9 0.4 8.4 5.40 9.0 27.00 3.6 0.0 3.64 3.3 9.5 3.83 2.7 9.2 4.23 2.2 9.0 4.52.5 8.8 5.0 0.8 8.5 5.50 9.5 27.00 3.8 0.0 3.64 3.5 9.5 3.83 2.8 9.2 4.23 2.4 9. 4.52.7 8.8 5.0.0 8.5 5.50 22.0 30.00 5. 0. 3.73 4.6 9.8 3.83 3.7 9.4 4.32 3.4 9.3 4.62 2.9 9. 5. 2.0 8.7 5.70 24.0 32.00 5.9 0.2 3.73 5.5 9.9 3.93 4.6 9.5 4.42 4.3 9.4 4.72 3.6 9.2 5.2 2.9 9.0 5.80 3TW2542-5A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FUYP AFR 9 7 BF 0.07 AFR 29 00 BF 0.07 AFR 32 25 BF 0.07 7. Add the following corrections to power input of each model. Model Supply FUYP 7 V 0.05 W 0 00 V 0.05 W 0 25 W 0 7.5 m 0 m 9

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FUYP7-25BV + RYP7-00L7V RYP7-25L7W Heating capacity Outdoor 7 00 25 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.04 6.7 2. 7.4 2. 8. 2.9 8.6 2.9 - - 8.0 6.3 2.04 6.7 2. 7.4 2.9 8.0 2.26 8.6 2.26 - - 20.0 6.3 2.9 6.7 2.9 7.3 2.26 8.0 2.34 8.6 2.42 9.3 2.49 22.0 6.3 2.9 6.7 2.26 7.3 2.34 8.0 2.42 8.6 2.42 9. 2.49 24.0 6.3 2.26 6.7 2.34 7.3 2.42 7.9 2.49 8.6 2.49 9. 2.57 6.0 8.5 2.93 9.3 3.02 0. 3..2 3.2.9 3.30 - - 8.0 8.4 3.02 9.2 3. 0. 3.2. 3.30.9 3.39 - - 20.0 8.4 3.2 9. 3.30 0.0 3.39.0 3.48.7 3.57 2.7 3.66 22.0 8.4 3.30 9. 3.39 0.0 3.48.0 3.57.7 3.66 2.6 3.75 24.0 8.3 3.39 9. 3.48 9.8 3.57 0.8 3.66.5 3.75 2.6 3.85 6.0. 3.63 2.0 3.8 2.9 3.90 4. 3.99 5.0 4.7 - - 8.0. 3.72 2.0 3.90 2.9 3.99 4.0 4.7 4.9 4.26 - - 20.0. 3.90.8 4.08 2.8 4.26 4.0 4.35 4.8 4.44 6.0 4.62 22.0. 3.99.8 4.7 2.8 4.26 4.0 4.44 4.8 4.53 6.0 4.7 24.0 0.9 4.08.8 4.26 2.7 4.44 3.9 4.53 4.8 4.7 5.8 4.89 3TW2542-A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FUYP AFR 9 7 BF 0.07 AFR 29 00 BF 0.07 AFR 32 AFR BF 0.07 6. Add the following corrections to power input of each model. Model Supply FUYP 7 V 0.4 W 0 00 V 0.03 W 0 25 W 0 20

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FDYMP7-25L7V + RYP7-00L7V RYP7-25L7W 3 Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 7 00 25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.00 6.2 4.8.82 6. 4.7 2.08 5.7 4.6 2.25 5.5 4.5 2.43 5.3 4.4 2.69 4.9 4. 2.95 4.0 20.00 6.6 4.8.9 6.5 4.7 2.7 6.0 4.6 2.34 5.9 4.5 2.43 5.5 4.4 2.69 5.3 4. 2.95 6.0 22.00 7.2 4.9.9 7.0 4.8 2.7 6.5 4.7 2.34 6.3 4.6 2.5 6.0 4.5 2.77 5.5 4.2 3.03 8.0 25.00 7.7 5..99 7.5 4.9 2.7 7.2 4.8 2.43 6.8 4.7 2.60 6.4 4.5 2.77 6.0 4.4 3.2 9.0 27.00 8.0 5.2.99 7.7 5. 2.7 7.3 4.9 2.43 7. 4.7 2.60 6.6 4.6 2.86 6.2 4.5 3.2 9.5 27.00 8.0 5.2.99 7.9 5. 2.7 7.4 4.9 2.43 7.2 4.7 2.60 6.7 4.6 2.86 6.3 4.5 3.2 22.0 30.00 8.7 5.3 2.08 8.5 5.2 2.25 8.0 5. 2.5 7.9 4.8 2.69 7.4 4.7 2.86 6.8 4.5 3.2 24.0 32.00 9.4 5.3 2.08 9. 5.2 2.25 8.6 5. 2.60 8.4 4.9 2.69 8.0 4.7 2.95 7.4 4.5 3.29 2.0 8.00 8.4 7.0 2.66 8.3 6.9 2.86 8. 6.7 3.26 7.8 6.6 3.45 7.5 6.2 3.85 6.9 6.0 4.24 4.0 20.00 8.9 7.0 2.76 8.8 6.9 2.86 8.7 6.7 3.26 8.4 6.6 3.45 7.8 6.2 3.85 7.5 6.0 4.24 6.0 22.00 0. 7. 2.76 9.8 7.0 2.96 9. 6.8 3.35 8.9 6.7 3.55 8.5 6.3 3.95 7.8 6. 4.34 8.0 25.00 0.8 7.4 2.76 0.5 7.3 2.96 9.8 6.9 3.35 9.6 6.8 3.55 9.0 6.6 3.95 8.4 6.2 4.44 9.0 27.00. 7.5 2.76 0.8 7.4 3.06 0. 7.0 3.45 0.0 6.9 3.65 9.4 6.7 4.04 8.7 6.3 4.54 9.5 27.00.2 7.5 2.76.0 7.4 3.06 0.3 7.0 3.45 0. 6.9 3.65 9.5 6.7 4.04 8.8 6.3 4.54 22.0 30.00 2.2 7.6 2.86.8 7.5 3.06.2 7. 3.55.0 7.0 3.75 0.4 6.9 4.4 9.6 6.6 4.54 24.0 32.00 3.0 7.7 2.96 2.7 7.6 3.6.9 7.3 3.65.6 7. 3.85. 7.0 4.24 0.3 6.7 4.64 2.0 8.00. 9. 3.36 0.8 8.8 3.66 0.0 8.3 3.96 9.7 8.2 4.25 9.2 8.0 4.65 8.6 7.6 5.34 4.0 20.00.8 9. 3.46.4 8.8 3.66 0.7 8.3 4.06 0.4 8.2 4.35 9.8 8.0 4.75 9.2 7.6 5.34 6.0 22.00 2.7 9.2 3.46 2. 8.9 3.76.4 8.4 4.06. 8.3 4.45 0.4 8. 4.85 9.7 7.7 5.44 8.0 25.00 3.3 9.5 3.56 3.0 9. 3.76 2. 8.7 4.5.8 8.6 4.55.2 8.3 4.95 0.4 8.0 5.44 9.0 27.00 3.6 9.6 3.66 3.3 9. 3.86 2.7 8.8 4.25 2.2 8.6 4.55.5 8.4 5.04 0.8 8. 5.54 9.5 27.00 3.8 9.6 3.66 3.5 9. 3.86 2.8 8.8 4.25 2.4 8.7 4.55.7 8.4 5.04.0 8. 5.54 22.0 30.00 5. 9.7 3.76 4.6 9.4 3.86 3.7 9.0 4.35 3.4 8.9 4.65 2.9 8.7 5.4 2.0 8.3 5.74 24.0 32.00 5.9 9.8 3.76 5.5 9.5 3.96 4.6 9. 4.45 4.3 9.0 4.75 3.6 8.8 5.24 2.9 8.6 5.84 3TW2542-3A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb =0.29x60xAFR(m 3 /min) x (-BF) x (DB*-EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FDYMP AFR 9 7 BF 0. AFR 27 00 BF 0.2 AFR 35 25 BF 0.4 7. Add the following corrections to power input of each model. Model Supply FDYMP 7 V 0.08 W 0 00 V 0. W 0 25 W 0 7.5 m 0 m 2

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FDYP25B7V + RYP25L7W Cooling capacity V/T: 230V [50Hz] W: 400V [50Hz] Outdoor 25 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.0. 0.4 3.46 0.8 0. 3.76 0.0 9.6 4.07 9.7 9.5 4.37 9.2 9.3 4.78 8.6 8.9 5.49 4.0 20.0.8 0.4 3.56.4 0. 3.76 0.7 9.6 4.7 0.4 9.5 4.48 9.8 9.3 4.88 9.2 8.9 5.49 6.0 22.0 2.7 0.5 3.56 2. 0.2 3.87.4 9.7 4.7. 9.6 4.58 0.4 9.4 4.99 9.7 9.0 5.60 8.0 25.0 3.3 0.8 3.66 3.0 0.4 3.87 2. 0.0 4.27.8 9.9 4.68.2 9.6 5.09 0.4 9.3 5.60 9.0 27.0 3.6 0.9 3.76 3.3 0.4 3.97 2.7 0. 4.37 2.2 9.9 4.68.5 9.7 5.9 0.8 9.4 5.70 9.5 27.0 3.8 0.9 3.76 3.5 0.4 3.97 2.8 0. 4.37 2.4 0.0 4.68.7 9.7 5.9.0 9.4 5.70 22.0 30.0 5..0 3.87 4.6 0.7 3.97 3.7 0.3 4.48 3.4 0.2 4.78 2.9 0.0 5.29 2.0 9.6 5.90 24.0 32.0 5.9. 3.87 5.5 0.8 4.07 4.6 0.4 4.58 4.3 0.3 4.88 3.6 0. 5.39 2.9 9.9 6.00 3TW25202-6A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw FDYP25B7V + RYP25L7W. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb = 0.29 x 60 x AFR(m 3 /min) x (-BF) x (DB -EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: Level difference: 6. Air flow rate and BF are tabulated below. Model FDYP AFR 45 25 BF 0.25 7.5 m 0 m Heating capacity Outdoor 25 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CDB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0.5 3.76 2.5 3.95 3.4 4.04 4.7 4.3 5.7 4.32 - - 8.0.5 3.85 2.5 4.04 3.4 4.3 4.6 4.32 5.6 4.42 - - 20.0.5 3.95 2.3 4.3 3.4 4.23 4.6 4.42 5.6 4.60 7.0 4.70 2.0.5 4.04 2.3 4.23 3.4 4.42 4.6 4.5 5.5 4.60 6.7 4.79 22.0.5 4.3 2.3 4.32 3.4 4.42 4.6 4.60 5.5 4.70 6.7 4.89 24.0.3 4.23 2.3 4.42 3.3 4.60 4.5 4.70 5.5 4.89 6.4 5.07 3TW25202-2 SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FDYP AFR 45 25 BF 0.25 22

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FDYP200 250B7V + RYP200 250B7W Cooling capacity V: 230V [50Hz] W: 3 400V [50Hz] 3 Outdoor RYP200 RYP250 Indoor Outdoor temperature ( CDB) EWB EDB 20 25 32 35 40 46 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 2.0 8.0 7.5 4.8 6.49 6.8 4.3 6.98 5.8 3.7 7.83 5.4 3.4 8.23 4.8 3.0 9.02 4. 2.6 0.08 4.0 20.0 8.7 4.9 6.59 7.9 4.4 7.08 6.9 3.8 7.94 6.5 3.6 8.36 5.9 3.2 9.5 5. 2.7 0.22 6.0 22.0 20.0 5.0 6.68 9.2 4.5 7.9 8. 3.9 8.06 7.7 3.7 8.49 7.0 3.3 9.29 6.2 2.8 0.37 8.0 25.0 2.3 5.9 6.79 20.4 5.4 7.3 9.3 4.8 8.9 8.9 4.6 8.62 8.2 4.2 9.43 7.4 3.7 0.54 9.0 27.0 2.9 6.8 6.84 2. 6.3 7.37 20.0 5.7 8.26 9.5 5.5 8.69 8.8 5. 9.5 7.9 4.6 0.62 22.0 30.0 24. 6.8 7.02 23.2 6.3 7.56 22.0 5.8 8.47 2.5 5.5 8.92 20.7 5. 9.75 9.8 4.7 0.89 24.0 32.0 25.6 6.8 7.5 24.6 6.4 7.70 23.4 5.8 8.63 22.9 5.5 9.09 22. 5. 9.93 2. 4.6.07 2.0 8.0 22.4 9. 7.62 2.5 8.5 8.20 20.2 7.7 9.9 9.7 7.3 9.67 8.9 6.8 0.58 8.0 6.2.83 4.0 20.0 24.0 9.2 7.73 23.0 8.6 8.3 2.7 7.8 9.32 2.2 7.5 9.82 20.3 7.0 0.73 9.4 6.4 2.00 6.0 22.0 25.6 9.3 7.84 24.6 8.7 8.45 23.2 7.9 9.46 22.7 7.6 9.97 2.8 7. 0.90 20.8 6.5 2.7 8.0 25.0 27.2 20.5 7.97 26.2 9.9 8.58 24.8 9.2 9.6 24.2 8.8 0.2 23.3 8.3.06 22.3 7.7 2.37 9.0 27.0 28. 2.7 8.03 27.0 2. 8.65 25.6 20.3 9.69 25.0 20.0 0.20 24. 9.5.6 23.0 8.9 2.46 22.0 30.0 30.9 2.6 8.24 29.7 2. 8.87 28.2 20.3 9.94 27.6 20.0 0.47 26.5 9.5.45 25.4 8.9 2.78 24.0 32.0 32.8 2.7 8.39 3.6 2. 9.03 30.0 20.4 0.3 29.4 20.0 0.67 28.3 9.5.65 27. 8.9 3.00 3TW23632-A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kw. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb = 0.29 x 60 x AFR(m 3 /min) x (-BF) x (DB -EDB) Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 6. Air flow rate and BF are tabulated below. Model FDYP200 FDYP250 AFR 69 89 BF 0.25 0.25 23

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 FDYP200 250B7V + RYP200 250B7W Heating capacity V: 230V [50Hz] W: 3 400V [50Hz] Outdoor RYP200 RYP250 Indoor Outdoor temperature ( CDB) EWB EDB -0-5 0 6 0 5 ( C) ( C) TC PI TC PI TC PI TC PI TC PI TC PI 9.0 6.0 5. 6.42 6.7 6.47 9.6 6.76 23.4 7.6 26.3 7.50 30.3 7.99.0 8.0 4.8 6.58 6.6 6.65 9.5 6.95 23.2 7.37 26. 7.72 30. 8.23 2.0 20.0 4.6 6.76 6.3 6.84 9.3 7.5 23. 7.59 26.0 7.95 30.0 8.49 3.0 2.0 4.5 6.86 6.2 6.92 9.3 7.25 23.0 7.70 26.0 8.08 29.9 8.62 4.0 22.0 4.4 6.96 6.0 7.02 9.3 7.36 23.0 7.82 25.9 8.2 29.8 8.76 5.0 24.0 4.2 7.6 5.7 7.23 9.2 7.59 22.9 8.08 25.8 8.46 29.7 9.05 9.0 6.0 7.6 7.4 9.5 7.47 22.9 7.8 27.3 8.27 30.8 8.66 35.4 9.22.0 8.0 7.3 7.60 9.4 7.68 22.7 8.02 27. 8.5 30.6 8.9 35.2 9.50 2.0 20.0 7. 7.8 9. 7.89 22.6 8.26 27.0 8.76 30.4 9.8 35.0 9.80 3.0 2.0 6.9 7.92 8.9 7.99 22.6 8.37 26.9 8.89 30.3 9.32 34.9 9.95 4.0 22.0 6.8 8.03 8.7 8.0 22.5 8.49 26.9 9.03 30.3 9.47 34.9 0. 5.0 24.0 6.6 8.27 8.4 8.34 22.5 8.76 26.8 9.32 30.2 9.77 34.8 0.44 3TW23632-2A SYMBOLS AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( CWB) EDB: Entering dry bulb temp. ( CDB) DB*: Dry bulb temp. ( CDB) ( CDB) TC: Total cooling capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities which include a deduction for indoor fan motor heat 2. Shows nominal capacities 3. Capacities are based on following conditions: Corresponding refrigerant piping length: 7.5 m Level difference: 0 m Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FDYP200 FDYP250 AFR 69 89 BF 0.25 0.25 24

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables FDYMP7-25L7V + RYP7-00L7V RYP7-25L7W 3 Heating capacity Outdoor 7 00 25 V: 230V [50Hz] W: 400V [50Hz] Indoor Outdoor temperature ( CWB) EDB -0-5 0 6 0 5 ( C) TC PI TC PI TC PI TC PI TC PI TC PI 6.0 6.3 2.7 6.7 2.25 7.4 2.25 8. 2.33 8.6 2.33 - - 8.0 6.3 2.7 6.7 2.25 7.4 2.33 8.0 2.4 8.6 2.4 - - 20.0 6.3 2.33 6.7 2.33 7.3 2.4 8.0 2.49 8.6 2.57 9.3 2.65 22.0 6.3 2.33 6.7 2.4 7.3 2.49 8.0 2.57 8.6 2.57 9. 2.65 24.0 6.3 2.4 6.7 2.49 7.3 2.57 7.9 2.65 8.6 2.65 9. 2.73 6.0 8.5 3.22 9.3 3.32 0. 3.42.2 3.52.9 3.62 - - 8.0 8.4 3.32 9.2 3.42 0. 3.52. 3.62.9 3.72 - - 20.0 8.4 3.52 9. 3.62 0.0 3.72.0 3.82.7 3.92 2.7 4.02 22.0 8.4 3.62 9. 3.72 0.0 3.82.0 3.92.7 4.02 2.6 4.2 24.0 8.3 3.72 9. 3.82 9.8 3.92 0.8 4.02.5 4.2 2.6 4.22 6.0.4 3.76 2.4 3.95 3.4 4.04 4.6 4.3 5.5 4.32 - - 8.0.4 3.85 2.4 4.04 3.4 4.3 4.5 4.32 5.5 4.42 - - 20.0.4 4.04 2.2 4.23 3.3 4.42 4.5 4.5 5.4 4.60 6.6 4.79 22.0.4 4.3 2.2 4.32 3.3 4.42 4.5 4.60 5.4 4.70 6.6 4.89 24.0.3 4.23 2.2 4.42 3.2 4.60 4.4 4.70 5.4 4.89 6.3 5.07 3TW2542-4A SYMBOLS AFR: Air flow rate (m 3 /min) EDB: Entering dry bulb temp. ( CDB) WB: Wet bulb temperature ( CWB) TC: Total cooling capacity (kw) PI: Power input (kw) (comp.+indoor+outdoor fan motor) Caution: TC is shown by kw. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: Outdoor air : 85 % RH. however, the condition on nominal capacity is 7 CDB/6 CWB (heating) Corresponding refrigerant piping length: 7.5 m Level difference: 0 m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model FDYMP AFR 9 7 BF 0. AFR 27 00 BF 0.2 AFR 35 25 BF 0.4 6. Add the following corrections to power input of each model. Model Supply FDYMP 7 V 0 W 0 00 V 0.09 W 0 25 W 0 25

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3 3-3- Cooling capacity in low latent heat application Method and illustration The capacity will be increased when the dip switch DS2-4, mounted on the outdoor PCB, is set to ON. Detail dip switch setting OFF (factory setting) ON OFF ON ON OFF Capacity result at low temperature The capacity increases when outdoor temperature drops below 2 C as indicated on table below Dip switch OFF (factory setting) Dip switch ON Capacity low temperature 00%* 50 200% *This is a relative comparisson to indicate an increase of 50 to 00% capacity with the dipswitch ON. Caution + Finally the capacity result will depend on the total condition of the installation site. This is the responsibility of the customer. + There is additional limitation for the relative humidity when operating this switch. Finally, it will depend on the total condition of the installation site and is responsibility of the customer. + Evaluation is necessary for each installation site by a professional responsible installer. + Only use the switch for capacity increase in the area indicated on the graph of page 4. + Do not set the switch in combination with the option EKRPER, this is only for use of Daikin indoor units. Reason for limitation When operating with switch ON, there will be a change of freeze protection control see table on next page. By this there will be some risk of + Ice building up at indoor heat exchanger. + Water blown off from the unit into the room. 26

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 3 Capacity tables 3-2 Details about software change L-type B-type Dip switch OFF (factory setting) Dip switch ON Function: capacity increase at low temperature Not present Not activated Activated + Intelligent control + Indoor decision + Indoor decision + 25min integrated coil temp - C + 25min integrated coil temp - C + 25min integrated coil temp - C + coil temp A C continuous min ORH H H OR + coil temp A C continuous min OR + coil temp A C continuous min + 20min continuous comp operation time + 20min continuous comp operation time & IN condition + 20min continuous comp operation time + coil temp - C continuous min Freeze protection (partly) H &H + coil temp - C continuous min H & + coil temp - C continuous min A : depend on each indoor type A : depend on each indoor type A : depend on each indoor type Ex.:FHY...-3 C Ex.:FHY...-3 C Ex.: FHY...-3 C FHYC...-5 C FHYC...-5 C FHYC...-5 C OUT condition Coil temp >0 C continuous 0min X Coil temp >7 C continuous 3min Discharge temp (TK) control limitation Air TK acceptable area TK acceptable area Humidity limitation TK acceptable area Air >2 C:Normal Air 2 C: 3-2 Details about software change 3 Capacity tables Pair Application R-407C RYP7-25L7V/W RYP200-250B7W Only use the switch for capacity increase in this area. 3 3-2 27

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 4 Dimensional drawings 4 RYP7L7 Hole for anchor bolt 4-M2 Gas pipe connection J5.9 flare 2 Liquid pipe connection - J9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock hole J34) 7 Control wiring intake (knock hole J27) 8 Drain outlet unit (mm) 3TW2544- RYP00L7 Hole for anchor bolt 4-M2 Gas pipe connection J9. flare 2 Liquid pipe connection - J9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock hole J34) 7 Control wiring intake (knock hole J27) 8 Drain outlet unit (mm) 3TW2554-28

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 4 Dimensional drawings RYP25L7 unit (mm) 4 Hole for anchor bolt 4-M2 Gas pipe connection J9. flare 2 Liquid pipe connection - J9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in switch box) 5 Refrigerant piping intake 6 Power supply wiring intake (knock hole J34) 7 Control wiring intake (knock hole J27) 8 Drain outlet 3TW25204- RYP200B7 unit (mm) (Distance between anchor bolt holes) Foundation hole (Distance between anchor bolt holes) Liquid piping connection opening 2 Gas piping connection opening 3 Ground terminal 4 Power supply wiring outlet Pipes connected to the side Knock hole for lower piping (pipes connected to the front) NOTE: The dimensions marked with z refer to distances after fixing the accessory pipes. 3TW2484-C 29

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 4 Dimensional drawings 4 RYP250B7 unit (mm) Pipes connected to the side (Distance between anchor bolt holes) Foundation hole (Distance between anchor bolt holes) Liquid piping connection opening 2 Gas piping connection opening 3 Ground terminal 4 Power supply wiring outlet Knock hole for lower piping (pipes connected to the front) NOTE: The dimensions marked with z refer to distances after fixing the accessory pipes. 3TW2494-C 30

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 5 Operation range RYP7-25L7 Cooling Model name 5 RYP7L7V RYP00L7V RYP25L7W RYP7L7W RYP00L7W Heating Outdoor temp. ( CDB) Operation range Allowable range of operation (pull-down) Outdoor temp. ( CWB) Allowable range of operation (warming-up) Operation range Indoor temp. ( CWB) Notes: - Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). - To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind. Indoor temperature ( CDB) 3TW2543-A RYP200-250B7 Cooling Notes: The graph is based on the following conditions:. Equivalent piping length 70 m 2. Level difference 30 m 3. Indoor air flow rate 72m 3 /min (200 class) 90m 3 /min (250 class) Outdoor temp. ( CDB) Allowable range of operation (pull-down) Outdoor temp. ( CWB) Heating Warming up period Indoor temp. ( CWB) Indoor temperature ( CDB) 3TW23633-3

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 6 Piping diagrams 6 RYP7L7 Solenoid valve Electronic expansion valve One way valve One way valve Filter Filter Heat exchanger One way valve One way valve Strainer Receiver Service port /4 One way valve Heat exchanger 4-way valve Low pressure switch High pressure switch Muffler Filter Field piping J9.5 C22OT-O Field piping J5.9 C22OT-O Filter Compressor Service port /4 Indoor unit Stop valve (with service port /4 flare) Outdoor unit Heating Cooling O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW2545- RYP00-25L7 Solenoid valve Electronic expansion valve One way valve One way valve Filter Filter Heat exchanger One way valve One way valve Strainer Receiver Service port /4 One way valve Heat exchanger 4-way valve Filter Low pressure switch High pressure switch Muffler Filter Field piping J9.5 C22OT-O Field piping J5.9 C22OT-O Compressor Service port /4 Indoor unit Stop valve (with service port /4 flare) Outdoor unit Heating Cooling O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW2555-32

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 6 Piping diagrams RYP200-250B7 6 One way valve One way valve Outdoor heat exchanger One way valve One way valve Indoor heat exchanger Solenoid valve Propeller fan Receiver Fan Filter Electronic expansion valve Filter 4-way valve Service port /4 Filter Muffler Field piping A Low pressure switch High pressure switch Field piping B Compressor Indoor unit Stop valve (with service port /4 flare) Outdoor unit O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW23635-33

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 7 Wiring diagrams 7 RYP7-00L7V Indoor Outdoor NOTE ON OFF ON OFF :. Confirm the method of setting the selector switches by service. When the unit is shipped by factory all switches are set to be off. 2. Do not operate the unit by short-circuiting SLP It will cause compressor failure. Switch box (Outdoor) g Field wiring D : Terminal F : Connector : Wire clamp b : Protective earth (screw) L : Live N : Neutral Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow Position of compressor terminal Wire entrance AP Printed circuit board BS Push button (forced defrost-pump down) CR Capacitor (MF) C3R Capacitor (MC) C4 Starting capacitor (MC) DS, DS2 Selector switch FU, F2U Fuse (250V, 0A, jb ) F3U Field fuse HAP Light emitting diode (service monitor green) KM Magnetic contactor (MC) KR Magnetic relay (KM) K3R Magnetic relay (YS) K4R Magnetic relay (Y2S) K8R,K9R,K0R Magnetic relay (MF) KR Starting relay MC Motor compressor MF Motor fan QM Q3E RT R2T R3T R4C RC SPH Thermo switch (MF) Earth leak detector Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Resistor Signal receiver circuit Pressure switch (high) SLP Pressure switch (low) SD Safety devices input TA Current transformer TR Transformer (220-240V/24.9V) TC Signal transmission circuit XM,X2M Terminal strip YE Expansion valve (electronic type) YS 4-way valve Y2S Solenoid valve 2TW2546- RYP7-00L7W Switch box (Outdoor) Indoor NOTE Outdoor :. Do not operate the unit by short-circuiting SLP It will cause compressor failure. 2. Confirm the method of setting the selector switches by service. When the unit is shipped by factory all switches are set to be off. ON OFF ON OFF g Field wiring D : Terminal F : Connector : Wire clamp b : Protective earth (screw) L : Live N : Neutral Position of compressor terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow Wire entrance AP Printed circuit board BS Push button (forced defrost-pump down) CR Capacitor (MF) DS, DS2 Selector switch FU, F2U Fuse (250V, 0A, jb ) F3U Field fuse HAP Light emitting diode (service monitor green) KM Magnetic contactor (MC) KR Magnetic relay (KM) K3R Magnetic relay (YS) K4R Magnetic relay (Y2S) K8R,K9R,K0R Magnetic relay (MF) MC Motor compressor MF Motor fan PRC Phase reverse circuit QM Thermo switch (MF) Q3E RT R2T R3T RC SPH SLP SD TA Earth leak detector Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer TR Transformer (220-240V/24.9V) TC Signal transmission circuit XM,X2M Terminal strip X3M YE Expansion valve (electronic type) YS 4-way valve Y2S Solenoid valve 2TW2586-34

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 7 Wiring diagrams RYP25L7W 7 Switch box (Outdoor) Indoor NOTE Outdoor :. Do not operate the unit by short-circuiting SLP It will cause compressor failure. 2. Confirm the method of setting the selector switches by service. When the unit is shipped by factory all switches are set to be off. ON OFF ON OFF g Field wiring D : Terminal F : Connector : Wire clamp b : Protective earth (screw) L : Live N : Neutral Position of compressor terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow Wire entrance AP Printed circuit board BS Push button (forced defrost-pump down) CR Capacitor (MF) C2R Capacitor (M2F) DS, DS2 Selector switch FU, F2U Fuse (250V, 0A, jb ) F3U Field fuse HAP Light emitting diode (service monitor green) KM Magnetic contactor (MC) KR Magnetic relay (KM) K3R Magnetic relay (YS) K4R Magnetic relay (Y2S) K5R,K6R,K7R Magnetic relay (M2F) K8R,K9R,K0R Magnetic relay (MF) MC Motor compressor MF Motor fan M2F Motor fan 2 PRC Phase reverse circuit QM Q2M Q3E RT R2T R3T RC SPH SLP Thermo switch (MF) Thermo switch (M2F) Earth leak detector Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) SD Safety devices input TA Current transformer TR Transformer (220-240V/24.9V) TC Signal transmission circuit XM,X2M Terminal strip X3M YE Expansion valve (electronic type) YS 4-way valve Y2S Solenoid valve 2TW2596- RYP200-250B7W Note: Do not operate the unit by short-circuiting SLP Indoor g Field wiring D Terminal F : Connector : Wire clamp b : Protective earth (screw) L : Live N : Neutral Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow Switch box Outdoor L-RED L2-WHT L3-BLK N-BLU AP,A2P,A3P Printed circuit board BS Push button (forced defrost-pump down) CR,C2R Capacitor (MF-M2F) DS Selector switch (defrost) DS2 Selector switch (various see PCB) DS3 Selector switch (emergency) FC Overcurrent relay FU,F2U Fuse (250V, 0A) F3U Field fuse HAP Light emitting diode (service monitor green) HP,H2P Light emitting diode (service monitor red) JHC Crankcase heater KM Magnetic contactor (MC) MC Motor (compressor) MF,M2F Motor (fan) PRC Phase reverse circuit QL,Q2L Thermo switch (MF) Q3E Earth leak detector RT R2T R3T RC RyC RyCH RyF-2 RyR RyS Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Magnetic relay (KM) Magnetic relay (JHC) Magnetic relay (MF-M2F) Magnetic relay (YS) Magnetic relay (YR) SLP SPH SD TR TC XM YE YR YS Pressure switch (low) Pressure switch (high) Safety devices input Transformer (230V/20.V) Signal transmission circuit Terminal strip Expansion valve 4-way valve Solenoid valve 2TW23636-B 35

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 7 Wiring diagrams 7 RYP7-25L7 Field wire Symbol explication I = Pair II = Twin III = Triple M = Master S = Slave = Earth leak detector 2 = Fuse 3 = Remote control 4TW2549-6 36

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 8 Sound level 8- Sound level data Model H (cooling) 230V, 50Hz H (heating) Sound pressure level Measuring location Sound power level (H) (cooling) 8 8- RYP7L7 50 52 63 RYP00L7 53 56 66 RYP25L7 53 56 67 RYP200B7 57 57 77 RYP250B7 57 57 77 8-2 Sound pressure spectrum RYP7L7 RYP7L7 Cooling Heating Sound pressure level (db) Sound pressure level (db) 3TW2547-A Octave band center frequency (Hz) 3TW2547-2A Octave band center frequency (Hz) Data is valid at free field condition 2 Data is valid at nominal conditions. 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20µPa 5 Curve for RYP7-25L7V/W in cooling mode 37

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 8 Sound level 8 8-2 Sound pressure spectrum RYP00L7 Cooling RYP00L7 Heating 8-2 Sound pressure level [db(a)] Sound pressure level [db(a)] 3TW2557-A Octave band center frequency (Hz) 3TW2557-2A Octave band center frequency (Hz) RYP25L7 Cooling RYP25L7 Heating Sound pressure level [db(a)] Sound pressure level [db(a)] 3TW25207-A Octave band center frequency (Hz) 3TW25207-2A Octave band center frequency (Hz) Data is valid at free field condition 2 Data is valid at nominal conditions. 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20µPa 5 Curve for RYP7-25L7V/W in cooling mode 38

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 8 Sound level 8-2 Sound pressure spectrum RYP200B7 Cooling RYP200B7 Heating 8 Sound pressure level [db(a)] Sound pressure level [db(a)] 8-2 3TW23637- Octave band center frequency (Hz) 3TW23637- Octave band center frequency (Hz) RYP250B7W Cooling RYP250B7W Heating Sound pressure level [db(a)] Sound pressure level [db(a)] 3TW23647- Octave band center frequency (Hz) 3TW23647- Octave band center frequency (Hz) Data is valid at free field condition 2 db(a) = A-weighted sound pressure level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20Pa 39

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 8 Sound level 8 8-2 Sound pressure spectrum RYP7L7 Cooling RYP00L7 Cooling 8-2 Sound pressure level [db(a)] Sound pressure level [db(a)] 3TW2547-3 Octave band center frequency (Hz) 3TW2557-3 Octave band center frequency (Hz) RYP25L7 Cooling Sound pressure level [db(a)] Data is valid at free field condition 2 Data is valid at nominal conditions. 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20µPa 5 Curve for RYP7-25L7V/W in cooling mode 3TW25207-3 Octave band center frequency (Hz) 40

Pair Application R-407C RYP7-25L7V/W RYP200-250B7W 9 Accessories 9- Standard accessories RYP200-250B7 Gas pipes 9 9-9-2 Optional accessories Available options for RYP7-25L7V,W Name of option RYP7L RYP00L RYP25L Central drain plug KKPJ5F80 Refrigerant branch piping Connection to Air handling unit Available options for RYP200-250B7W Twin KHRQ22M20TA7 Triple KHRP27HB7 Option RYP200B7 RYP250B7 Fan motor size up NFM22C5 Refnet KHRQ22M20TA7* Refnet KHRQ22M64T7* Refnet KHRP27HB7* * Table with possible indoor combinations = combination matrix 3TW2369-A See chapter RYP-L7/B7, twin/triple/double twin application EKRPER 3TW2549-A 3TW2389-A 3TW2369-2A 4