Fan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow

Similar documents
FDCLP2 Constant Volume Series Flow, Low Profile

fan powered terminals

High Performance Fan Coils FCHG Genesis Series Horizontal

Dual Duct Terminal Units DPS, DDS Series, DPQ, DDQ Series, DPV, DDV Series, DPM, DDM Series, DPUQ, DDUQ Series

SINGLE DUCT AIR TERMINAL UNITS

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

single / dual duct terminals

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

FAN POWERED TERMINAL UNITS

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

SINGLE DUCT AIR TERMINAL UNITS

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

PERFORMANCE DATA Intermittent Volume (Parallel Flow), Standard Design

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

FAN POWERED TERMINAL UNITS

RETROFIT TERMINAL UNITS

FPV, FDV Series Variable Volume Parallel Flow

HORIZONTAL HIGH CAPACITY FAN COIL UNITS DUCTED

SPV / SDV Series SINGLE DUCT TERMINAL UNITS

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Variable Air Volume (VAV) Pressure Independent Control

I Fan Powered Terminal Unit

Fan-Powered Parallel

SPVQ / SDVQ Series QUIET SINGLE DUCT TERMINAL UNIT

FCVC Series VERTICAL FAN COILS

Laboratory Room Single Duct Supply Air Terminal

catalog SDL Single-Duct, Low-Height, VAV Terminals

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

ANSI/AHRI Standard 881 (SI) with Addendum Standard for Performance Rating of Air Terminals

Fan-Powered Series. Table of Contents. Model Number Description FPS 2 3. Service Model Number Description FPS 4. Selection Procedure FPS 5 7

VAV RETROFIT/BYPASS TERMINAL UNITS TABLE OF CONTENTS RETROFIT/BYPASS TERMINAL UNITS. E-2 Excellence in Air Distribution MODEL RVE MODEL KLB MODEL SVE

Laboratory Room Single Duct Supply Air Terminal

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

STR Circular VAV Terminal Units

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

ANSI/AHRI Standard 880 (I-P) 2011 Standard for Performance Rating of Air Terminals

Fan-Powered Parallel

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017

catalog SDL Single-Duct, Low-Height, VAV Terminals

UNDERFLOOR FAN POWERED TERMINAL UNITS

Single-Duct. Table of Contents. Model Number Description SD 2 3. Service Model Number Description SD 4. Selection Procedure SD 5 6

Unit Report For CH-1 Replacement Project: Marlboro County High School Chiller Replacement 10/22/2018

IAQ. ROUND DUCT RETROFIT Model ARR

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

Laboratory Exhaust Air Terminal

Performance Rating of Air Terminals

catalog SDR Single-Duct VAV Terminals

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Vertical Hi-Rise Fan Coil Unit (Model FS)

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

series RVV Variable flow rate controllers

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Fan - Powered Terminal Unit Series Flow

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

IAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW

Residential Packaged Geothermal Heat Pump

Product Data. AXIS 45X, 45U, 42K, 35BF Access Floor Terminal Units for Variable Air Volume Systems

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

Product Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

FMU4X, FMC4X FMU4Z, FMC4Z

Large Belt Drive (HBH/V) Series HBH HBV

PIM Pressure Independent Module

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Kirby WRC Remote Condenser. With HyBlade EC Fans and AxiTop Diffuser

VHIA High-Static Ducted Indoor Units - 60HZ

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

FAN POWERED TERMINAL UNITS

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

BAC / BHC Product Specifications

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Submittal. Holder Construction Company. Reviewed. Reviewed as Noted. Rejected. 1. Updates per Bulletin #4

Vertical Floor Fan Coil Unit (Model FW)

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

catalog CFRQ, Extra Quiet Series Flow, Constant Volume Fan Powered VAV Terminals

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

FAN POWERED TERMINAL UNITS

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

catalog VFR Parallel Flow, Fan-Powered, VAV Terminals

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN

HCH6. Product Specifications

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

catalog VFL Parallel Fan-Powered, Low-Height, VAV Terminals

YEAR-ROUND AIR CONDITIONING Our Deluxe-Aire units are ideally suited to provide heating, cooling and air filtration for areas where it is not

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Submittal PESVD

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

catalog VFR Parallel Flow, Fan-Powered, 50/60 Hz VAV Terminals

Transcription:

Recommended Air Volume Ranges CP 101 Unit Size L/s Min.* L/s Max. cfm Min.* cfm Max. 6 31 212 66 450 8 62 378 132 800 10 104 637 221 1350 12 146 991 310 2100 14 207 1416 439 3000 16 268 1888 568 4000 CP 100 and CP 200 Controller Unit Size L/s Min.* L/s Max. cfm Min.* cfm Max. 6 44 212 93 450 8 88 378 187 800 10 147 637 312 1350 12 203 991 430 2100 14 293 1416 621 3000 16 379 1888 803 4000 Electronic or Digital Controls Unit Size L/s Min.* L/s Max. cfm Min.* cfm Max. 6 31 212 66 450 8 62 378 132 800 10 104 637 221 1350 12 146 991 310 2100 14 207 1416 439 3000 16 268 1888 568 4000 Notes: Factory calibrated controls must be selected within the above flow range limits. A minimum value of zero is also available. The maximum flow setting of the controller must be equal to or less than the selected capacity of the recirculating fan. On controls mounted by Price but supplied by others, the air volume ranges are guidelines only. * Selection of air flow limits below the listed values is not recommended. Stability and accuracy may not be acceptable at lower than recommended air flow limits. The actual performance will vary depending on the terminal unit controls supplied. Minimum air fl ow limit is based on min.02 in. w.g. differential pressure signal from air flow sensor (.04 in. w.g. for CP100 and CP200). Selection of air fl ow limits below the listed values is not recommended. Stability and accuracy may not be acceptable at lower than recommended air flow limits. The actual performance will vary depending on the terminal unit controls supplied. Maximum air flow limit is based on max 1.0 in. w.g. differential pressure signal from air flow sensor. F-449

Typical Selection Guide Cooling Cycle 100% Primary Discharge NC Ps Across Unit Radiated NC Ps Across Unit Unit Air Flow Min. Ps Min. Pt. 0.5 in. w.g. 1.0 in. w.g. 1.5 in. w.g. 0.5 in. w.g. 1.0 in. w.g. 1.5 in. w.g. Size cfm L/s in.w.g Pa in.w.g Pa 125Pa 250Pa 375Pa 125Pa 250Pa 375Pa 2006 250 118 0.06 14 0.16 39 20 23 25 -- -- -- 350 165 0.11 28 0.31 76 22 25 26 -- -- -- 400 189 0.14 36 0.40 99 24 27 28 -- 21 450 212 0.18 45 0.50 125 25 28 30 -- 21 23 2008 400 189 0.02 5 0.09 23 -- 20 22 -- -- -- 600 283 0.04 10 0.21 52 23 26 28 -- 22 24 700 330 0.05 13 0.28 70 25 28 31 -- 27 800 378 0.06 16 0.36 91 24 28 30 21 26 29 2010 750 354 0.01 3 0.11 27 -- 21 25 -- 25 28 1100 519 0.03 7 0.23 57 20 26 29 23 30 33 1350 637 0.04 10 0.35 86 23 29 32 26 32 36 3008 400 189 0.02 5 0.09 23 -- 20 22 -- -- -- 600 283 0.04 10 0.21 52 23 26 28 -- 22 24 700 330 0.05 13 0.28 70 25 28 31 -- 27 800 378 0.06 16 0.36 91 24 28 30 21 26 29 3010 750 354 0.01 3 0.11 27 -- 21 25 -- 25 28 1100 519 0.03 7 0.23 57 20 26 29 23 30 33 1350 637 0.04 10 0.35 86 23 29 32 26 32 36 3012 900 425 0.01 2 0.06 14 -- 23 27 -- 23 27 1300 614 0.01 2 0.11 27 21 28 32 21 28 31 1600 755 0.01 2 0.16 40 24 30 34 24 30 34 2100 991 0.01 2 0.27 67 27 34 38 27 34 37 4010 750 354 0.01 2 0.12 29 -- 20 23 -- -- 22 1100 519 0.01 2 0.24 59 20 25 29 -- 22 26 1350 637 0.01 2 0.35 87 23 28 31 -- 24 28 4012 900 425 0.01 2 0.07 18 -- 21 25 -- 22 26 1300 614 0.01 2 0.14 36 -- 26 29 -- 25 29 1600 755 0.01 2 0.21 53 22 28 32 21 27 31 2100 991 0.01 2 0.36 89 26 32 36 24 30 34 4014 1500 708 0.01 2 0.08 20 -- 26 30 22 28 32 2100 991 0.01 2 0.15 38 22 30 34 25 31 35 2500 1180 0.01 2 0.21 52 25 32 36 26 33 37 3000 1416 0.01 2 0.30 74 27 34 38 28 35 39 5012 900 425 0.01 2 0.08 21 -- -- -- -- -- 23 1300 614 0.01 2 0.16 41 -- 20 23 -- 23 26 1600 755 0.01 2 0.24 60 -- 23 26 21 26 28 2100 991 0.01 2 0.41 102 20 26 29 23 28 31 5014 1500 708 0.01 2 0.11 27 -- -- 23 -- 24 27 2100 991 0.01 2 0.20 51 -- 24 27 22 27 31 2500 1180 0.01 2 0.28 71 -- 26 29 24 29 32 3000 1416 0.01 2 0.41 101 23 28 32 25 31 34 5016 2500 1180 0.01 2 0.14 36 -- 24 28 24 31 35 2800 1321 0.01 2 0.18 44 -- 26 30 25 32 36 3500 1652 0.01 2 0.27 68 23 30 34 27 34 38 4000 1888 0.01 2 0.35 88 25 32 36 28 35 39 6016 1500 708 0.01 2 0.12 29 -- -- -- -- 23 26 2100 991 0.01 2 0.22 55 -- 22 25 20 26 29 2500 1180 0.01 2 0.31 77 -- 25 28 22 27 31 3000 1416 0.01 2 0.44 109 23 28 31 23 29 33 6016 2500 1180 0.01 2 0.17 41 -- 20 24 22 27 31 2800 1321 0.01 2 0.21 51 -- 22 26 23 29 32 3500 1652 0.01 2 0.32 79 -- 26 29 25 31 34 4000 1888 0.01 2 0.41 102 22 28 31 27 32 36 1. NCs are derived from sound power levels, which are obtained in accordance with AHRI Standard 880-2011 and ASHRAE Standard 130-2008. 2. NCs are derived from sound power levels which include duct end corrections per AHRI Standard 880-2011. Please refer to page F25 for more details. 3. Blank spaces (--) indicate NCs less than 20. 4. Air flow is given in L/s and cfm. 5. ΔPs is the difference in static pressure from inlet to discharge of the unit. 6. ΔPt is the difference in total pressure from inlet to discharge of the unit. 7. Min. ΔPs is the minimum static pressure required to achieve rated air flow. 8. Pressure is given in Pa and in. w.g. 9. Fan external static pressure is 63 Pa (0.25 in.w.g) in all cases. 10. NC values are calculated based on typical attenuation values outlined in Appendix E, AHRI Standard 885-2008, A Procedure for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets. Typical Attenuation Values: Radiated Sound Total Deduction Octave Band Mid Frequency, Hz. 125 250 500 1000 2000 4000 All Sizes 18 19 20 26 31 36 Discharge Sound Total Deduction Octave Band Mid Frequency, Hz. 125 250 500 1000 2000 4000 < 300 cfm 24 28 39 53 59 40 300 700 cfm 27 29 40 51 53 39 > 700 cfm 29 30 41 51 52 39 F-450 All Metric dimensions ( ) are soft conversion. Copyright Price Industries Limited 2011.

Typical Selection Guide Heating Cycle Fan Only Unit Air Flow Discharge Radiated Size L/s cfm NC NC 20 118 250 -- 30 165 350 -- 32 212 450 -- 33 260 550 -- 33 283 600 -- 34 30 236 500 -- 28 319 675 -- 31 378 800 -- 32 460 975 -- 34 519 1100 22 36 590 1250 24 37 40 378 800 -- 33 481 1020 22 36 585 1240 26 38 689 1460 28 40 793 1680 30 42 897 1900 32 43 50 708 1500 23 38 793 1680 24 40 878 1860 27 43 963 2040 29 45 1048 2220 31 47 1085 2300 32 48 60 944 2000 27 44 1029 2180 28 45 1114 2360 30 47 1199 2540 31 48 1284 2720 32 49 1369 2900 34 50 1. NCs are derived from sound power levels, which are obtained in accordance with AHRI Standard 880-2011 and ASHRAE Standard 130-2008. 2. NCs are derived from sound power levels which include duct end corrections per AHRI Standard 880-2011. Please refer to page F25 for more details. 3. Blank spaces (--) indicate NCs less than 20. 4. Fan external static pressure is 63 Pa (0.25 in.w.g) in all cases. 5. NC values are calculated based on typical attenuation values outlined in Appendix E, AHRI Standard 885-2008, A Procedure for Estimating Occupied Space Sound Levels in the Application of Air Terminals and Air Outlets. Typical Attenuation Values: Radiated Sound Total Deduction Octave Band Mid Frequency, Hz. 125 250 500 1000 2000 4000 All Sizes 18 19 20 26 31 36 Discharge Sound Total Deduction Octave Band Mid Frequency, Hz. 125 250 500 1000 2000 4000 < 300 cfm 24 28 39 53 59 40 300 700 cfm 27 29 40 51 53 39 > 700 cfm 29 30 41 51 52 39 NC vs Sound Power Levels Compare Them Carefully Price represents the sound performance data for the FPV/FDV series of fan powered terminals in two manners. The laboratory attained discharge and radiated sound power levels for each unit at various flows and inlet static pressures is presented in the Acoustical Data tables. This data is derived in accordance with AHRI Standard 880 and shows the 'raw' sound power levels of the terminal in the second through seventh octave bands with NO attenuation allowances. This data includes AHRI standard ratings which are on record with the Air-Conditioning Refrigeration Institute. Price also offers this Typical Application and Selection Guide to assist you in selecting the proper size and configuration of terminal for your needs. The attenuation allowances listed are based on values suggested in AHRI Standard 885-2008, Appendix E. The suggested attenuation allowances are intended to be representative of typical jobsite constructions. If your conditions differ significantly from these it is recommended you utilize the sound power level data in the catalog and the procedures outlined in AHRI Standard 885-2008. If the NC levels listed in the Price catalog are being compared to other manufacturers catalogued NC information, a careful review of the other manufacturers attenuation allowances must be made. If allowances other than recommended AHRI Standard 885-2008, Appendix E are used, a fair comparison of NC levels cannot be performed. F-451

Discharge Sound Data Cooling Cycle 100% Primary Sound Power Levels Lw db re 10-12 Watts 0.5 in. w.g. [125 Pa] 1.0 in. w.g. [250 Pa] 1.5 in. w.g. [375 Pa] Unit Air Flow Octave Band Octave Band Octave Band Size L/s cfm 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 2006 118 250 64 50 41 35 31 27 67 54 44 38 34 33 68 56 46 40 37 36 165 350 68 55 46 41 36 31 71 60 50 44 40 36 72 62 52 45 42 40 189 400 70 58 48 43 38 32 72 62 52 46 42 38 74 64 54 48 44 41 212 450 71 60 50 45 40 34 74 64 54 48 44 39 75 66 56 49 46 42 2008 189 400 65 51 44 38 35 28 67 55 48 42 40 35 69 58 50 44 43 40 283 600 69 57 49 43 39 32 72 61 52 47 44 39 74 64 55 49 48 43 330 700 71 59 50 45 41 33 74 63 54 49 46 40 75 66 56 51 49 45 378 800 72 61 52 47 42 34 75 65 56 50 48 41 77 68 58 52 51 46 2010 354 750 66 55 49 45 40 32 70 60 55 50 46 40 73 63 58 53 50 45 519 1100 69 59 53 50 44 36 74 65 58 54 50 44 77 68 62 57 54 49 637 1350 71 62 55 52 46 38 76 67 60 57 53 46 78 70 64 60 56 51 3008 189 400 65 51 44 38 35 28 67 55 48 42 40 35 69 58 50 44 43 40 283 600 69 57 49 43 39 32 72 61 52 47 44 39 74 64 55 49 48 43 330 700 71 59 50 45 41 33 74 63 54 49 46 40 75 66 56 51 49 45 378 800 72 61 52 47 42 34 75 65 56 50 48 41 77 68 58 52 51 46 3010 354 750 66 55 49 45 40 32 70 60 55 50 46 40 73 63 58 53 50 45 519 1100 69 59 53 50 44 36 74 65 58 54 50 44 77 68 62 57 54 49 637 1350 71 62 55 52 46 38 76 67 60 57 53 46 78 70 64 60 56 51 3012 425 900 66 56 53 47 43 35 72 62 60 54 49 43 75 66 64 58 53 47 614 1300 70 59 55 50 46 39 75 66 62 57 52 46 78 69 67 61 56 51 755 1600 72 61 57 51 48 41 77 67 64 58 54 48 80 71 68 62 58 53 991 2100 75 63 59 53 50 44 80 70 66 60 56 51 83 74 70 64 60 55 4010 354 750 65 54 48 44 37 33 69 59 54 50 43 40 72 63 58 53 47 44 519 1100 69 59 52 49 41 36 73 64 58 55 48 43 76 68 62 58 51 47 637 1350 71 62 54 52 43 37 76 67 60 57 50 44 78 70 64 61 53 49 4012 425 900 65 54 49 43 38 31 70 60 56 50 45 39 73 63 60 55 49 43 614 1300 69 59 53 47 41 35 74 64 59 54 48 42 76 68 63 58 52 47 755 1600 71 61 55 49 43 37 76 67 61 56 50 44 79 70 66 61 54 49 991 2100 73 64 57 52 45 39 78 70 64 59 52 47 81 73 68 63 56 52 4014 708 1500 68 59 54 49 44 38 74 64 60 56 50 45 77 66 64 60 54 49 991 2100 71 63 57 52 47 41 77 68 63 59 53 48 80 70 67 63 57 52 1180 2500 73 65 59 54 48 43 78 70 65 60 55 50 82 72 68 64 58 53 1416 3000 74 67 61 55 50 45 80 72 66 62 56 51 83 74 70 66 60 55 5012 425 900 61 51 46 41 38 32 66 56 51 47 44 40 68 58 53 50 48 44 614 1300 65 56 50 46 43 36 69 61 55 51 48 43 72 63 58 55 52 48 755 1600 67 59 53 48 45 37 71 63 57 54 51 45 74 66 60 57 54 50 991 2100 69 63 56 52 48 40 74 67 61 57 54 48 76 70 63 61 57 52 5014 708 1500 64 56 51 48 44 37 69 60 56 54 50 44 72 63 59 58 54 49 991 2100 67 60 54 51 47 41 72 65 59 57 54 48 75 67 63 61 58 52 1180 2500 68 63 56 53 49 43 74 67 61 59 56 50 76 70 64 63 60 54 1416 3000 70 65 58 54 51 45 75 69 63 61 58 52 78 72 66 65 62 56 5016 1180 2500 67 59 54 52 47 43 72 64 60 59 55 50 75 66 63 63 59 54 1321 2800 68 61 55 53 48 44 74 65 61 60 56 51 77 68 65 64 60 55 1652 3500 71 64 58 55 50 46 77 68 64 62 58 53 80 71 67 66 62 57 1888 4000 73 66 59 56 51 47 78 70 65 63 59 54 81 73 69 67 63 58 6014 708 1500 63 52 51 47 45 40 67 57 56 53 51 46 69 59 59 57 54 50 991 2100 67 57 54 50 48 43 71 61 59 56 54 49 73 64 62 59 57 53 1180 2500 69 59 55 51 50 45 73 63 61 57 56 51 75 66 64 61 59 55 1416 3000 71 61 57 53 52 47 75 66 62 59 57 53 78 68 66 62 61 56 6016 1180 2500 65 57 54 49 47 42 69 62 60 55 53 49 72 65 64 59 57 53 1321 2800 66 58 55 50 48 43 71 63 61 56 54 50 74 66 65 60 58 54 1652 3500 69 61 57 52 50 46 74 66 64 58 56 52 76 69 67 62 60 56 1888 4000 71 63 59 53 51 47 75 68 65 59 57 54 78 71 69 63 61 57 1. Test data obtained in accordance with AHRI Standard 880-2011 and ASHRAE Standard 130-2008. 2. Sound power levels include duct end corrections per AHRI Standard 880-2011. Please refer to page F25 for more details. 3. Air flow given in L/s and cfm. 4. Pressure is given in Pa and in.w.g. 5. Fan external static pressure is 63 Pa (0.25 in.w.g.) in all cases. 6. AHRI certified data is highlighted in blue. All other data are application ratings. 7. Application ratings are outside the scope of the AHRI 880 Certification Program. F-456 All Metric dimensions ( ) are soft conversion. Copyright Price Industries Limited 2011.

Radiated Sound Data Cooling Cycle 100% Primary Sound Power Levels Lw db re 10-12 Watts 0.5 in. w.g. [125 Pa] 1.0 in. w.g. [250 Pa] 1.5 in. w.g. [375 Pa] Unit Air Flow Octave Band Octave Band Octave Band Size L/s cfm 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7 2006 118 250 48 37 33 30 25 23 52 41 36 31 26 25 54 43 37 32 27 26 165 350 52 42 39 35 30 27 56 46 42 37 31 29 58 48 44 37 32 31 189 400 54 44 42 37 32 29 57 48 45 39 33 31 59 50 46 39 34 32 212 450 55 46 44 39 34 30 59 50 47 40 35 33 61 52 49 41 36 34 2008 189 400 51 41 37 30 25 19 55 45 40 32 29 23 57 47 41 34 31 26 283 600 56 47 43 35 29 23 59 51 45 38 33 27 61 53 47 40 36 30 330 700 58 49 45 37 31 24 61 53 48 40 35 29 63 55 49 42 37 31 378 800 59 51 47 39 33 25 63 55 50 42 36 30 65 57 51 43 39 33 2010 354 750 57 47 41 36 29 25 62 53 47 41 34 30 65 56 50 43 37 33 519 1100 60 51 45 40 32 27 66 57 51 44 37 32 69 60 54 46 40 35 637 1350 63 53 47 41 34 28 68 59 53 46 39 34 71 63 56 48 42 37 3008 189 400 51 41 37 30 25 19 55 45 40 32 29 23 57 47 41 34 31 26 283 600 56 47 43 35 29 23 59 51 45 38 33 27 61 53 47 40 36 30 330 700 58 49 45 37 31 24 61 53 48 40 35 29 63 55 49 42 37 31 378 800 59 51 47 39 33 25 63 55 50 42 36 30 65 57 51 43 39 33 3010 354 750 57 47 41 36 29 25 62 53 47 41 34 30 65 56 50 43 37 33 519 1100 60 51 45 40 32 27 66 57 51 44 37 32 69 60 54 46 40 35 637 1350 63 53 47 41 34 28 68 59 53 46 39 34 71 63 56 48 42 37 3012 425 900 56 46 42 37 28 26 61 52 48 43 33 31 64 56 52 46 37 34 614 1300 59 50 45 40 31 28 64 56 51 45 37 33 67 59 55 49 40 36 755 1600 61 52 46 41 33 29 66 58 53 47 39 34 69 61 57 50 42 37 991 2100 64 55 49 43 36 30 69 61 55 49 41 35 72 64 59 52 44 38 4010 354 750 52 44 40 35 26 25 57 50 44 39 30 28 60 54 47 41 33 30 519 1100 55 48 43 39 30 27 60 54 48 43 35 30 63 57 51 45 38 33 637 1350 56 49 45 41 32 28 61 55 50 45 37 32 64 59 53 47 40 34 4012 425 900 55 46 42 34 27 24 60 52 48 40 33 29 62 56 51 43 36 32 614 1300 58 49 45 37 30 26 62 56 51 43 36 31 65 59 54 46 39 34 755 1600 59 51 46 38 32 27 64 57 53 44 37 32 67 61 56 48 41 35 991 2100 61 54 49 40 34 28 66 60 55 46 39 33 69 64 58 50 43 36 4014 708 1500 58 53 48 41 35 29 63 58 54 46 41 35 65 62 57 50 44 39 991 2100 61 55 51 44 39 32 66 61 57 49 44 39 68 64 60 53 48 42 1180 2500 63 57 52 45 40 34 67 62 58 51 46 40 70 66 62 54 49 44 1416 3000 64 58 54 47 42 36 69 64 60 52 48 42 71 67 63 56 51 46 5012 425 900 50 43 41 33 27 24 54 48 46 39 32 29 57 51 49 43 35 33 614 1300 54 47 45 38 32 27 58 52 49 44 37 32 61 55 52 47 40 36 755 1600 56 49 47 41 35 29 60 54 51 47 39 34 63 57 54 50 42 37 991 2100 59 52 49 44 38 31 63 57 54 50 43 36 66 60 56 53 46 40 5014 708 1500 54 48 45 38 32 26 59 53 50 44 38 33 62 56 53 47 42 37 991 2100 57 51 48 41 36 30 62 56 53 47 42 37 65 59 56 51 45 41 1180 2500 59 53 50 43 38 32 64 58 54 49 44 39 67 61 57 53 47 43 1416 3000 60 55 51 45 39 34 66 59 56 51 46 41 69 62 59 54 49 45 5016 1180 2500 59 52 50 44 38 33 64 57 56 50 45 41 67 60 60 53 49 45 1321 2800 60 54 51 45 40 35 65 58 57 51 47 42 68 61 61 55 51 46 1652 3500 63 56 53 47 42 38 68 61 59 53 49 45 71 63 63 57 53 49 1888 4000 64 57 54 49 44 40 69 62 60 55 51 47 72 65 64 58 55 51 6014 708 1500 52 45 44 38 33 28 57 51 49 43 38 33 60 54 52 46 40 36 991 2100 55 48 46 40 37 32 61 54 52 46 42 37 64 57 55 49 45 40 1180 2500 57 50 48 42 39 34 63 56 53 47 44 39 66 59 56 51 47 42 1416 3000 60 52 49 43 41 36 65 57 55 49 46 41 68 60 58 52 49 44 6016 1180 2500 56 49 48 41 38 34 62 54 53 46 43 38 64 57 56 49 45 41 1321 2800 58 50 49 43 39 35 63 55 54 48 44 40 66 59 57 51 47 42 1652 3500 60 52 51 45 42 38 65 58 56 50 47 43 68 61 59 53 50 45 1888 4000 61 54 52 46 44 40 66 59 58 51 49 44 69 62 61 54 51 47 1. Test data obtained in accordance with AHRI Standard 880-2011 and ASHRAE Standard 130-2008. 2. Sound power levels include duct end corrections per AHRI Standard 880-2011. Please refer to page F25 for more details. 3. Air flow given in L/s and cfm. 4. Pressure is given in Pa and in.w.g. 5. Fan external static pressure is 63 Pa (0.25 in.w.g.) in all cases. 6. AHRI certified data is highlighted in blue. All other data are application ratings. 7. Application ratings are outside the scope of the AHRI 880 Certification Program. F-457

Discharge and Radiated Sound Power Levels Heating Cycle - Fan Only Sound Power Levels, LW, db, re 10-12 Watts Discharge Sound Data Radiated Sound Data Unit Air Flow Octave Band Octave Band Size L/s cfm 2 3 4 5 6 7 2 3 4 5 6 7 20 118 250 57 48 43 37 33 22 56 61 45 44 41 34 165 350 61 50 47 41 38 30 59 62 48 47 45 40 212 450 63 52 50 45 41 36 61 63 50 50 48 45 260 550 65 53 52 48 44 40 63 63 52 53 51 49 283 600 66 54 53 49 45 42 64 64 53 53 52 50 30 236 500 59 52 49 45 40 32 56 58 53 50 47 41 319 675 63 55 53 50 45 39 61 60 56 55 52 47 378 800 66 57 55 53 48 42 63 62 58 57 54 50 460 975 69 59 58 57 51 47 66 63 59 60 57 54 519 1100 71 60 60 59 53 50 68 64 60 61 59 56 590 1250 73 61 62 61 56 53 70 65 62 63 61 59 40 378 800 68 56 53 50 44 39 65 59 58 53 50 43 481 1020 71 59 56 54 48 44 68 62 61 56 53 48 585 1240 74 62 59 57 52 48 70 64 63 59 56 52 689 1460 76 64 61 60 55 52 72 66 65 61 58 55 793 1680 77 66 63 62 57 55 73 68 66 62 60 58 897 1900 79 68 65 64 60 58 75 70 68 64 62 60 50 708 1500 70 65 62 57 53 49 72 64 63 60 58 53 793 1680 72 67 63 60 56 53 74 66 65 62 60 56 878 1860 74 68 65 63 59 56 76 68 67 64 62 58 963 2040 76 69 66 65 61 58 77 70 68 66 64 61 1048 2220 78 70 67 67 63 61 79 71 69 68 66 63 1133 2300 79 71 68 68 64 62 80 72 70 69 66 63 60 944 2000 74 67 65 63 59 57 71 70 68 65 62 60 1029 2180 76 68 66 65 61 59 73 71 69 67 64 62 1114 2360 77 69 68 67 63 61 74 71 71 68 65 64 1199 2540 78 70 69 69 65 63 75 72 72 70 67 65 1284 2720 79 71 70 71 67 65 76 73 73 71 69 67 1369 2900 80 71 71 73 68 67 77 74 74 73 70 69 1. Test data obtained in accordance with AHRI Standard 880-2011 and ASHRAE Standard 130-2008. 2. Sound power levels include duct end corrections per AHRI Standard 880-2011. Please refer to page F25 for more details. 3. Air flow given in L/s and cfm. 4. Fan external static pressure is 63 Pa (0.25 in.w.g) in all cases. 5. AHRI certified data is highlighted in blue. All other data are application ratings. 6. Application ratings are outside the scope of the AHRI 880 Certification Program. F-458 All Metric dimensions ( ) are soft conversion. Copyright Price Industries Limited 2011.

AHRI Certification Rating Points Discharge Sound Power Level, db (1) (2) (3) (4) (5) (6) Unit Size Primary Air Flow Fan Air Flow Power Input Minimum Operating Pressure Fan only 100% Primary Air Valve Flow at 1.5 in. w.g. [375 Pa] Octave Band Octave Band L/s cfm L/s cfm Watts Pa in. Water 2 3 4 5 6 7 2 3 4 5 6 7 2006 189 400 283 600 300 35 0.14 74 64 54 48 44 41 74 64 54 48 44 41 2008 330 700 283 600 300 12 0.05 75 66 56 51 49 45 75 66 56 51 49 45 2010 519 1100 283 600 300 7 0.03 77 68 62 57 54 49 77 68 62 57 54 49 3008 330 700 590 1250 450 12 0.05 75 66 56 51 49 45 75 66 56 51 49 45 3010 519 1100 590 1250 450 7 0.03 77 68 62 57 54 49 77 68 62 57 54 49 3012 755 1600 590 1250 450 2 0.01 80 71 68 62 58 53 80 71 68 62 58 53 4010 519 1100 897 1900 750 2 0.01 76 68 62 58 51 47 76 68 62 58 51 47 4012 755 1600 897 1900 750 2 0.01 79 70 66 61 54 49 79 70 66 61 54 49 4014 991 2100 897 1900 750 2 0.01 80 70 67 63 57 52 80 70 67 63 57 52 5012 755 1600 1085 2300 1200 2 0.01 74 66 60 57 54 50 74 66 60 57 54 50 5014 991 2100 1085 2300 1200 2 0.01 75 67 63 61 58 52 75 67 63 61 58 52 5016 1321 2800 1085 2300 1200 2 0.01 77 68 65 64 60 55 77 68 65 64 60 55 6014 991 2100 1369 2900 1800 2 0.01 73 64 62 59 57 53 73 64 62 59 57 53 6016 1321 2800 1369 2900 1800 2 0.01 74 66 65 60 58 54 74 66 65 60 58 54 Radiated Sound Power Level, db (1) (2) (3) (4) (5) (6) Unit Size Primary Air Flow Fan Air Flow Power Input Minimum Operating Pressure Fan only 100% Primary Air Valve Flow at 1.5 in. w.g. [375 Pa] Octave Band Octave Band L/s cfm L/s cfm Watts Pa in. Water 2 3 4 5 6 7 2 3 4 5 6 7 2006 189 400 283 600 300 35 0.14 64 64 53 53 52 50 59 50 46 39 34 32 2008 330 700 283 600 300 12 0.05 64 64 53 53 52 50 63 55 49 42 37 31 2010 519 1100 283 600 300 7 0.03 64 64 53 53 52 50 69 60 54 46 40 35 3008 330 700 590 1250 450 12 0.05 70 65 62 63 61 59 63 55 49 42 37 31 3010 519 1100 590 1250 450 7 0.03 70 65 62 63 61 59 69 60 54 46 40 35 3012 755 1600 590 1250 450 2 0.01 70 65 62 63 61 59 69 61 57 50 42 37 4010 519 1100 897 1900 750 2 0.01 75 70 68 64 62 60 63 57 51 45 38 33 4012 755 1600 897 1900 750 2 0.01 75 70 68 64 62 60 67 61 56 48 41 35 4014 991 2100 897 1900 750 2 0.01 75 70 68 64 62 60 68 64 60 53 48 42 5012 755 1600 1085 2300 1200 2 0.01 80 72 70 69 66 63 63 57 54 50 42 37 5014 991 2100 1085 2300 1200 2 0.01 80 72 70 69 66 63 65 59 56 51 45 41 5016 1321 2800 1085 2300 1200 2 0.01 80 72 70 69 66 63 68 61 61 55 51 46 6014 991 2100 1369 2900 1800 2 0.01 77 74 74 73 70 69 64 57 55 49 45 40 6016 1321 2800 1369 2900 1800 2 0.01 77 74 74 73 70 69 66 59 57 51 47 42 1. Primary cfm is the standard rated air volume for the inlet size listed. 2. Fan cfm is maximum rated fan volume at 0.25 in. downstream static pressure. 3. Input watts is the maximum electrical power input at the maximum rated fan volume. 4. Min. operating pressure Inlet is the minimum operating pressure requirement of the primary air valve at the rated primary cfm. 5. Fan only sound power levels are at the maximum rated fan volume. 6. 100% primary sound power levels at rated primary cfm with fan off. 7. Sound power levels include duct end corrections per AHRI Standard 880-2011. Please refer to page F25 for more details. F-459

1 and 2 Row Hot Water Coil Data IP Units Size 20 Standard Size Rows gpm Loss 250 300 350 400 450 500 550 650 1 Row 0.5 0.06 8.6 9.2 9.7 10.1 10.5 10.8 11.1 11.6 Multi 1 0.19 10.5 11.4 12.2 12.9 13.5 14.1 14.6 15.4 Circuit 2 0.6 11.8 13.0 14.0 15.0 15.9 16.6 17.4 18.6 3 1.22 12.3 13.6 14.8 15.9 16.9 17.8 18.6 20.1 0.02 0.03 0.03 0.04 0.05 0.07 0.08 0.1 2 Row 1 0.32 17.8 19.5 21.1 22.4 23.5 24.6 25.5 27.1 Multi 2 1.00 20.3 22.7 24.8 26.7 28.4 30 31.4 34 Circuit 4 3.16 21.8 24.7 27.2 29.6 31.7 33.7 35.6 38.9 6 6.26 22.4 25.4 28.2 30.7 33.0 35.2 37.2 40.9 0.04 0.05 0.07 0.09 0.11 0.14 0.16 0.22 Size 20 High Capacity Rows gpm Loss 250 300 350 400 450 550 650 1 Row 0.5 0.15 10.6 11.4 12.0 12.6 13.0 13.8 14.4 Single 1 0.54 13.1 14.3 15.4 16.3 17.1 18.5 19.7 Circuit 2 1.98 14.8 16.5 17.9 19.2 20.4 22.4 24.2 3 4.29 15.5 17.4 19.0 20.5 21.8 24.2 26.2 0.01 0.02 0.02 0.03 0.04 0.05 0.07 2 Row 1 2.00 21.4 23.8 25.9 27.7 29.3 32.1 34.3 Multi 2 5.72 24.2 27.4 30.3 33.0 35.4 39.6 43.2 Circuit 4 16.48 25.9 29.6 33.1 36.3 39.2 44.6 49.4 6 30.65 26.5 30.4 34.1 37.5 40.7 46.5 51.8 0.03 0.04 0.05 0.06 0.07 0.1 0.14 Size 30 Standard Size Rows gpm Loss 550 600 650 700 800 900 1000 1 Row 1 0.19 14.6 15.0 15.4 15.8 16.5 17.1 17.6 Multi 2 0.61 17.4 18.0 18.6 19.2 20.2 21.2 22.0 Circuit 4 2.02 19.3 20.1 20.9 21.6 22.9 24.1 25.2 6 4.15 20.1 21.0 21.8 22.6 24.1 25.4 26.6 0.08 0.09 0.1 0.12 0.15 0.19 0.23 2 Row 1 0.33 25.5 26.3 27.1 27.8 29.0 30.0 30.9 Multi 2 1.00 31.4 32.7 34.0 35.1 37.1 38.9 40.5 Circuit 4 3.17 35.6 37.3 38.9 40.4 43.2 45.7 48.0 6 6.27 37.2 39.1 40.9 42.6 45.7 48.6 51.2 0.16 0.19 0.22 0.25 0.32 0.4 0.48 Size 30 High Capacity Rows gpm Loss 550 600 650 700 800 900 1000 1 Row 0.5 0.35 15.3 15.7 16.0 16.3 16.9 17.3 17.7 Single 1 1.03 20.1 20.8 21.4 22 23.1 24.0 24.8 Circuit 2 3.00 23.7 24.7 25.6 26.5 28.1 29.6 30.9 3 5.64 25.2 26.4 27.4 28.5 30.3 32.0 33.5 0.05 0.06 0.07 0.08 0.1 0.12 0.14 2 Row 1 0.4 30.3 31.4 32.3 33.2 34.6 35.9 37.0 Multi 2 1.22 38.1 39.8 41.4 42.9 45.6 47.9 50.0 Circuit 4 3.78 43.5 45.9 48.0 50.1 53.8 57.2 60.3 6 7.42 45.7 48.3 50.7 53 57.3 61.2 64.8 0.1 0.12 0.14 0.16 0.2 0.25 0.3 Size 40 Standard Coil Rows gpm Loss 800 900 1000 1100 1200 1300 1500 1 Row 1 0.23 19.2 20.0 20.6 21.2 21.7 22.2 23.0 Multi 2 0.72 23.6 24.8 25.8 26.7 27.6 28.4 29.8 Circuit 4 2.36 26.7 28.2 29.6 30.8 32.0 33.1 35.0 6 4.77 28.0 29.7 31.2 32.6 33.9 35.1 37.3 0.09 0.11 0.13 0.15 0.18 0.21 0.27 2 Row 1 0.41 32.5 33.7 34.8 35.7 36.5 37.3 38.5 Multi 2 1.24 41.9 44.1 46.0 47.8 49.4 50.8 53.3 Circuit 4 3.84 48.9 51.9 54.7 57.3 59.6 61.8 65.7 6 7.52 51.7 55.2 58.4 61.3 64.0 66.5 71.1 0.18 0.22 0.27 0.32 0.43 0.56 Size 40 High Capacity Rows gpm Loss 800 900 1000 1100 1200 1300 1500 1 Row 0.5 0.17 17.2 17.6 18.0 18.3 18.6 18.9 19.3 Single 1 0.6 24.4 25.3 26.1 26.9 27.5 28.1 29.1 Circuit 2 2.16 30.7 32.2 33.6 34.9 36.1 37.1 39.0 3 4.61 33.5 35.4 37.2 38.7 40.2 41.5 43.9 0.05 0.06 0.08 0.09 0.11 0.12 0.16 2 Row 1 0.53 38.2 39.7 40.9 42.0 42.9 43.8 45.1 Multi 2 1.59 50.8 53.6 56.0 58.3 60.3 62.1 65.3 Circuit 4 4.83 60.1 64.2 68.0 71.4 74.6 77.5 82.8 6 9.36 64.0 68.7 73.1 77.1 80.8 84.3 90.7 0.11 0.14 0.16 0.19 0.22 0.26 0.33 F-460 All Metric dimensions ( ) are soft conversion. Copyright Price Industries Limited 2011.

1 and 2 Row Hot Water Coil Data IP Units Size 50 Standard Coil Rows gpm Loss 1500 1600 1700 1800 1900 2000 2100 1 Row 1 0.29 27.3 27.8 28.2 28.6 29.0 29.3 29.6 Multi 2 0.9 35.7 36.6 37.3 38 38.7 39.3 39.9 Circuit 4 2.85 42.2 43.4 44.5 45.5 46.5 47.4 48.3 6 5.69 45.0 46.3 47.6 48.7 49.9 50.9 52.0 0.14 0.15 0.17 0.19 0.21 0.23 0.25 2 Row 1.5 0.43 51.7 52.6 53.5 54.3 55.0 55.7 56.3 Multi 3 1.36 68.3 70.1 71.7 73.2 74.7 76.0 77.3 Circuit 6 4.44 81.2 83.7 86.1 88.4 90.5 92.6 94.5 9 9.01 86.6 89.5 92.2 94.9 97.4 99.8 102.1 0.28 0.32 0.36 0.4 0.44 0.48 0.52 Size 50 High Capacity Rows gpm Loss 1500 1600 1700 1800 1900 2000 2100 1 Row 1 0.35 33.1 33.6 34.1 34.6 35.0 35.3 35.7 Multi 2 1.07 45.0 46.0 46.9 47.8 48.7 49.5 50.2 Circuit 4 3.35 54.5 56.0 57.5 58.9 60.2 61.4 62.6 6 6.61 58.6 60.4 62.1 63.7 65.3 66.8 68.2 0.09 0.1 0.11 0.12 0.13 0.14 0.16 2 Row 1.5 0.51 60.3 61.3 62.3 63.2 64.0 64.8 65.5 Multi 3 1.59 82.3 84.5 86.5 88.5 90.2 91.9 93.5 Circuit 6 5.11 99.7 103.1 106.3 109.3 112.1 114.8 117.4 9 10.24 107.1 111.1 114.8 118.4 121.7 125.0 128.1 0.18 0.21 0.23 0.25 0.28 0.3 0.33 Size 60 Standard Coil Rows gpm Loss 2000 2100 2200 2300 2400 2500 2600 1 Row 1 0.32 31.6 31.9 32.2 32.5 32.8 33.1 33.3 Multi 2 0.98 42.7 43.4 44.0 44.6 45.2 45.7 46.3 Circuit 4 3.1 51.8 52.8 53.7 54.6 55.5 56.4 57.2 6 6.15 55.7 56.9 58.0 59.1 60.1 61.1 62.1 0.16 0.18 0.19 0.21 0.23 0.24 0.26 2 Row 1.5 0.47 59.2 59.9 60.6 61.2 61.7 62.2 62.7 Multi 3 1.48 81.6 83.0 84.3 85.6 86.8 88.0 89.0 Circuit 6 4.78 99.8 101.9 104.0 106.1 108.0 109.8 111.6 9 9.63 107.7 110.2 112.7 115.1 117.4 119.6 121.7 0.34 0.41 0.44 0.48 0.51 0.55 Size 60 High Capacity Rows gpm Loss 2000 2100 2200 2300 2400 2500 2600 1 Row 1 0.35 35.3 35.7 36.0 36.3 36.6 36.9 37.1 Multi 2 1.07 49.5 50.2 50.9 51.6 52.2 52.8 53.4 Circuit 4 3.35 61.4 62.6 63.7 64.8 65.9 66.9 67.8 6 6.61 66.8 68.2 69.6 70.9 72.1 73.3 74.5 0.14 0.16 0.17 0.18 0.2 0.21 0.23 2 Row 1.5 0.51 64.8 65.5 66.2 66.8 67.3 67.9 68.4 Multi 3 1.6 91.9 93.5 95.0 96.4 97.8 99.0 100.2 Circuit 6 5.12 114.8 117.4 119.9 122.3 124.5 126.7 128.8 9 10.25 125.0 128.1 131.1 134.0 136.7 139.4 141.9 0.3 0.33 0.36 0.39 0.42 0.45 0.48 Correction Factors 1 and 2 Row Hot Water Coils Entering Water Temp, F Ent. Air Temp, F 120 130 140 150 160 170 180 190 200 210 220 60 0.55 0.65 0.75 0.85 0.94 1.04 1.14 1.24 1.34 1.44 1.54 65 0.51 0.60 0.70 0.80 0.90 1.00 1.09 1.19 1.29 1.40 1.50 70 0.46 0.56 0.65 0.75 0.85 0.95 1.05 1.15 1.25 1.35 1.45 75 0.42 0.51 0.61 0.71 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1. Tabulated values are in MBH (thousands of Btu per hour). 2. Tables are based on a temperature difference of 105 F (180 F entering water temperature and 75 F entering air temperature). For other temperature differences, multiply MBH values by factors as listed above. 3. Minimum air and water flow values are based on ASHRAE recommendations for coil selections. For selections below these tabulated air or water values, please consult your local Price representative. 4. Do not select coils for a leaving air temperature above 120 F. 5. HD (Head) loss is in ft of water. 6. Through the Coil Ps, is the pressure drop in in. of water across the coil. 7. Air temperature rise = ATR, ATR ( F) = 927 x MBH/cfm 8. Water temperature drop = WTD, WTD ( F) = 2.04 x MBH/gpm 9. Values in tables are listed for 0 ft of altitude and no glycol in the system. 10. For information outside the ranges used in the table, consult the current Price software or your Price representative for accurate coil information. 11. Heating coils used in this unit have performance rated and certified in accordance with the current edition of AHRI Standard 410. 12. Connections: Single Circuit 1/2 in. OD male solder Multi Circuit 7/8 in. OD male solder F-461

1 and 2 Row Hot Water Coil Data SI Units Size 20 Standard Size Coil HD Air Flow Rate (L/s) Rows L/s Loss 118 142 165 189 212 236 260 307 1 Row Multi 0.03 0.06 0.17 0.55 2.5 3.1 2.7 3.4 2.9 3.6 3.0 3.8 3.1 4.0 3.2 4.2 3.3 4.3 3.4 4.6 Circuit 0.13 0.19 1.8 3.64 3.5 3.6 3.8 4.0 4.2 4.4 4.4 4.7 4.7 5.0 4.9 5.3 5.1 5.5 5.5 5.9 5.0 7.5 7.5 10 12.5 17.5 20 25 2 Row Multi 0.06 0.13 0.97 2.98 5.3 6.0 5.8 6.7 6.2 7.3 6.6 7.9 7.0 8.4 7.3 8.9 7.6 9.3 8.0 10.1 Circuit 0.25 9.42 18.67 6.5 6.6 7.3 7.5 8.1 8.4 8.8 9.1 9.4 9.8 10.0 10.4 10.5 11.0 11.5 12.1 10.0 12.5 17.5 22.5 27.5 35.0 40.0 55 Size 20 High Capacity Rows Coil L/s HD Loss 118 142 165 Air Flow Rate (L/s) 189 212 260 307 1 Row 0.03 0.45 3.1 3.4 3.6 3.7 3.9 4.1 4.3 Single 0.06 1.61 3.9 4.2 4.6 4.8 5.1 5.5 5.8 Circuit 0.13 5.91 4.4 4.9 5.3 5.7 6.0 6.7 7.2 0.19 12.77 4.6 2.5 5.1 5.0 5.6 5.0 6.1 7.5 6.5 10.0 7.2 12.5 7.8 17.5 2 Row 0.06 5.95 6.3 7.0 7.7 8.2 8.7 9.5 10.2 Multi 0.13 17.05 7.2 8.1 9.0 9.8 10.5 11.7 12.8 Circuit 0.25 49.1 7.7 8.8 9.8 10.7 11.6 13.2 14.6 91.32 7.8 7.5 9.0 10.0 10.1 12.5 11.1 15.0 12.1 17.5 13.8 25.0 15.3 35.0 Size 30 Standard Size Rows Coil L/s HD Loss 260 283 307 Air Flow Rate (L/s) 330 378 425 472 1 Row 0.06 0.55 4.3 4.5 4.6 4.7 4.9 5.1 5.2 Multi 0.13 1.8 5.1 5.3 5.5 5.7 6.0 6.3 6.5 Circuit 0.25 6.03 5.7 6.0 6.2 6.4 6.8 7.2 7.5 12.38 5.9 20 6.2 22.5 6.5 25.0 6.7 30.0 7.1 37.5 7.5 47.5 7.9 57.5 2 Row 0.06 0.97 7.6 7.8 8.0 8.2 8.6 8.9 9.2 Multi 0.13 2.99 9.3 9.7 10.1 10.4 11.0 11.5 12.0 Circuit 0.25 9.43 10.5 11.1 11.5 12.0 12.8 13.5 14.2 18.69 11.0 40.0 11.6 47.5 12.1 55.0 12.6 62.5 13.6 80.0 14.4 100.0 15.2 120 Size 30 High Capacity Rows Coil L/s HD Loss 260 283 307 Air Flow Rate (L/s) 330 378 425 472 1 Row 0.03 1.05 4.5 4.6 4.7 4.8 5.0 5.1 5.3 Single 0.06 3.05 5.9 6.2 6.3 6.5 6.8 7.1 7.4 Circuit 0.13 8.93 7.0 7.3 7.6 7.9 8.3 8.8 9.1 0.19 16.79 7.5 12.5 7.8 15.0 8.1 17.5 8.4 20.0 9.0 25.0 9.5 30.0 9.9 35.0 2 Row 0.06 1.2 9.0 9.3 9.6 9.8 10.3 10.6 11.0 Multi 0.13 3.64 11.3 11.8 12.3 12.7 13.5 14.2 14.8 Circuit 0.25 11.28 12.9 13.6 14.2 14.8 16.0 17.0 17.9 22.1 13.5 25.0 14.3 30.0 15.0 35.0 15.7 40.0 17.0 50.0 18.1 62.5 19.2 75.0 Size 40 Standard Coil Rows Coil L/s HD Loss 378 425 472 Air Flow Rate (L/s) 519 566 614 708 1 Row 0.06 0.68 5.7 5.9 6.1 6.3 6.4 6.6 6.8 Multi 0.13 2.15 7.0 7.3 7.6 7.9 8.2 8.4 8.8 Circuit 0.25 7.02 7.9 8.4 8.8 9.1 9.5 9.8 10.4 14.22 8.3 22.5 8.8 27.5 9.2 32.5 9.7 37.5 10.0 45.0 10.4 52.5 11.0 67.5 2 Row 0.06 1.22 9.6 10.0 10.3 10.6 10.8 11.0 11.4 Multi 0.13 3.7 12.4 13.1 13.6 14.2 14.6 15.1 15.8 Circuit 0.25 11.44 14.5 15.4 16.2 17.0 17.7 18.3 19.5 22.4 15.3 45.0 16.4 55.0 17.3 67.5 18.2 80.0 19.0 95.0 19.7 107.5 21.1 140 Size 40 High Capacity Rows Coil L/s HD Loss 378 425 472 Air Flow Rate (L/s) 519 566 614 708 1 Row 0.03 0.51 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Single 0.06 1.79 7.2 7.5 7.7 8.0 8.2 8.3 8.6 Circuit 0.13 6.43 9.1 9.5 10.0 10.3 10.7 11.0 11.6 0.19 13.74 9.9 10.5 11.0 11.5 11.9 12.3 13.0 12.5 15.0 20.0 22.5 27.5 30.0 40.0 2 Row 0.06 1.59 11.3 11.8 12.1 12.4 12.7 13.0 13.4 Multi 0.13 4.74 15.0 15.9 16.6 17.3 17.9 18.4 19.3 Circuit 0.25 14.41 17.8 19.0 20.1 21.2 22.1 23.0 24.5 27.88 19.0 20.4 21.6 22.8 23.9 25.0 26.9 27.5 35.0 40.0 47.5 55.0 65.0 82.5 F-462 All Metric dimensions ( ) are soft conversion. Copyright Price Industries Limited 2011.

1 and 2 Row Hot Water Coil Data SI Units Size 50 Standard Coil Coil HD Air Flow Rate (L/s) Rows L/s Loss 708 755 802 850 897 944 991 1 Row 0.06 0.86 8.1 8.2 8.4 8.5 8.6 8.7 8.8 Multi 0.13 2.67 10.6 10.8 11.1 11.3 11.5 11.6 11.8 Circuit 0.25 8.5 12.5 12.9 13.2 13.5 13.8 14.0 14.3 16.95 13.3 13.7 14.1 14.4 14.8 15.1 15.4 35.0 37.5 42.5 47.5 52.5 57.5 62.5 2 Row 0.09 1.28 15.3 15.6 15.8 16.1 16.3 16.5 16.7 Multi 0.19 4.05 20.2 20.8 21.2 21.7 22.1 22.5 22.9 Circuit 13.25 24.0 24.8 25.5 26.2 26.8 27.4 28.0 0.57 26.85 25.7 26.5 27.3 28.1 28.9 29.6 30.2 70.0 80.0 90.0 100.0 110.0 120.0 130.0 Size 50 High Capacity Coil HD Air Flow Rate (L/s) Rows L/s Loss 708 755 802 850 897 944 991 1 Row 0.06 1.04 9.8 10.0 10.1 10.2 10.4 10.5 10.6 Multi 0.13 3.19 13.3 13.6 13.9 14.2 14.4 14.7 14.9 Circuit 0.25 9.98 16.1 16.6 17.0 17.4 17.8 18.2 18.6 19.69 17.4 17.9 18.4 18.9 19.3 19.8 20.2 22.5 25.0 27.5 30.0 32.5 35.0 40.0 2 Row 0.09 1.52 17.9 18.2 18.5 18.7 19.0 19.2 19.4 Multi 0.19 4.75 24.4 25.0 25.6 26.2 26.7 27.2 27.7 Circuit 15.23 29.6 30.5 31.5 32.4 33.2 34.0 34.8 0.57 30.51 31.7 32.9 34.0 35.1 36.1 37.0 38.0 45.0 52.5 57.5 62.5 70.0 75.0 82.5 Size 60 Standard Coil Coil HD Air Flow Rate (L/s) Rows L/s Loss 944 991 1038 1085 1133 1180 1227 1 Row 0.06 0.95 9.4 9.5 9.6 9.6 9.7 9.8 9.9 Multi 0.13 2.93 12.7 12.9 13.0 13.2 13.4 13.6 13.7 Circuit 0.25 9.24 15.3 15.6 15.9 16.2 16.5 16.7 16.9 18.32 16.5 16.9 17.2 17.5 17.8 18.1 18.4 40.0 45.0 47.5 52.5 57.5 60.0 65 2 Row 0.09 1.4 17.5 17.8 17.9 18.1 18.3 18.4 18.6 Multi 0.19 4.41 24.2 24.6 25.0 25.4 25.7 26.1 26.4 Circuit 14.24 29.6 30.2 30.8 31.4 32.0 32.5 33.1 0.57 28.69 31.9 32.7 33.4 34.1 34.8 35.4 36.1 85.0 95.0 102.5 110.0 120 127.5 137.5 Size 60 High Capacity Coil HD Air Flow Rate (L/s) Rows L/s Loss 944 991 1038 1085 1133 1180 1227 1 Row 0.06 1.05 10.5 10.6 10.7 10.8 10.8 10.9 11.0 Multi 0.13 3.2 14.7 14.9 15.1 15.3 15.5 15.6 15.8 Circuit 0.25 9.99 18.2 18.6 18.9 19.2 19.5 19.8 20.1 19.7 19.8 20.2 20.6 21.0 21.4 21.7 22.1 35.0 40.0 42.5 45.0 50.0 52.5 57.5 2 Row 0.09 1.53 19.2 19.4 19.6 19.8 20.0 20.1 20.3 Multi 0.19 4.76 27.2 27.7 28.1 28.6 29.0 29.3 29.7 Circuit 15.25 34.0 34.8 35.5 36.2 36.9 37.5 38.2 0.57 30.53 37.0 38.0 38.8 39.7 40.5 41.3 42.1 75.0 82.5 90.0 97.5 105.0 112.5 120.0 Correction Factors 1 and 2 Row Hot Water Coils Entering Water Temp, C Ent. Air Temp, C 49 54 60 66 71 77 82 87 93 99 104 16 0.53 0.62 0.71 0.81 0.90 1.00 1.09 1.19 1.28 1.38 1.47 18 0.49 0.58 0.67 0.76 0.86 0.95 1.05 1.14 1.24 1.33 1.43 21 0.44 0.53 0.63 0.72 0.81 0.91 1.00 1.09 1.19 1.29 1.38 24 0.40 0.49 0.58 0.67 0.77 0.86 0.95 1.05 1.14 1.24 1.34 1. Tabulated values are in kw (thousands of watts). 2. Tables are based on a temperature difference of 58 C (82 C entering water temperature and 24 C entering air temperature). For other temperature differences, multiply MBH values by factors as listed above. 3. Minimum air and water flow values are based on ASHRAE recommendations for coil selections. For selections below these tabulated air or water values, please consult your local Price representative. 4. Do not select coils for a leaving air temperature above 49 C. 5. HD (Head) loss is in kilopascals (kpa) of water. 6. Through the Coil Ps, is the pressure drop in Pascals (Pa) of water across the coil. 7. Air temperature rise = ATR, ATR ( C) = 829 x kw/l/s (Air flow) 8. Water temperature drop = WTD, WTD ( C) = 0.224 x kw/l/s (Water Flow) 9. Values in tables are listed for 0 metres of altitude and no glycol in the system. 10. For information outside the ranges used in the table, consult the current Price software or your Price representative for accurate coil information. 11. Heating coils used in this unit have performance rated and certified in accordance with the current edition of AHRI Standard 410. 12. Connections: Single Circuit 13 mm OD male solder Multi Circuit 22 mm OD male solder F-463