SMA Export Control Solution

Similar documents
Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

Hilton Hunkin Senior Application Engineer SMA Solar Technology South Africa

Planning Guidelines SMA SMART HOME The System Solution for more Independence

SMA FLEXIBLE STORAGE SYSTEM

SUNNY BOY 2000HF / 2500HF / 3000HF

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

Sunny Tripower. Can do everything that we can

Multi-Function Interface MULTI-FUNCTION RELAY

Technical Information PV Inverters

Wind Power Inverter WINDY BOY 5000A/6000A

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

PV inverter SUNNY MINI CENTRAL 7000HV

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Planning Guidelines SMA SMART HOME

Planning Guidelines SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION

[RENEX] [İstanbul, Ekim 2011]

SMA FLEXIBLE STORAGE SYSTEMS. SMA Solar Technology AG

Dr. Bernd Engel. Frank Greizer Joachim Laschinski Dr. Mike Meinhardt Dr. Matthias Victor. 20 th European PV Conference Barcelona 2005

Planning Guidelines SMA SMART HOME The System Solution for Greater Independence

Certificate of Conformity self-generation unit

Feed-in management with Solar-Log

Technical Information SUNNY BOY / SUNNY TRIPOWER Temperature Derating

Increased Self-Consumption with SUNNY ISLAND and SUNNY HOME MANAGER SMA FLEXIBLE STORAGE SYSTEM

SMA INTEGRATED STORAGE SYSTEM

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Technical Guidance for Customer Export Limiting Schemes

SUNNY BACKUP System. Solar Power Even in the Event of Grid Failure

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

Reverse Power Protection

OVERSIZING WHITEPAPER

Total number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1

500 / 630 / 720 / 760 / 800 / 850 / 900

Operating Manual SUNNY TRIPOWER 15000TL / 20000TL / 25000TL

The Future of Solar Technology

Installation Guide SUNNY TRIPOWER 60

Your home and business energy independance. Energy Bundle CA5000TPV-3D

Solar Inverters. No. 6, R. A. De Mel Mawatha, Colombo

Technical Information Temperature Derating for Sunny Boy and Sunny Tripower

Sunny Family 2010/2011

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

ABB central inverters PVS to 1000 kw

SMA Utility Power System

PRODUCT LIST ORDER:

System Monitoring SCHOOLMETERBOX AU

PV Aggregation Results from Germany

Operating Manual SUNNY BOY STORAGE 2.5

Requirements for PV Inverters in Germany and USA

Solar*Rewards Community Engineering Frequently Asked Questions For Garden Operators Minnesota

PowerRouter Solar Battery Self-use

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

Sunny Tripower CORE1.

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

Technical Requirements for Export Limiting Schemes

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Xcel Energy Guidelines for Interconnection of Electric Energy Storage with the Electric Power Distribution System

Solutions for Profitable PV Power Plants

User Manual SMA FUEL SAVE CONTROLLER 2.0

Technical information SUNNY BOY SMART ENERGY / SUNNY BOY STORAGE / SUNNY ISLAND

SP PRO KACO Managed AC Coupling

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

:34 1/15 Hub-4 / grid parallel - manual

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

IES GRID FEED-IN LIMITER

Installation Manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL

magellan solar export control solutions Magellan Power Solar Gate

Pre-announcement. Transformerless Solar Inverters

AS/NZS AS/NZS

Solar Electric System Proposal

Design of Off-Grid Systems with Sunny Island 4.4M / 6.0H / 8.0H Devices

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

MAX310 BEESMART SOLAR MICRO INVERTER TYPE 260. Apparent Power Control (APC) SOLAR PV MODULES UP TO 310 W peak

Simple and secure monitoring

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

Technical Data. Windy Boy 6000US. Windy Boy 5000US. Windy Boy 7000US

Enquiry Form for Micro and Small Generators 5MW and Less

WEB ENABLE ONLINE DATA LOGGER AND REMOTE MONITORING FOR 66 KW ON GRID SOLAR PV SYSTEM

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

ABB central inverters PVS to 1000 kw

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Energy Meters for Solar-Log Product Information

End-Customer Owned Decentralized Storage as a Part of the Smart Grid Volker Wachenfeld, SMA Solar Technology AG

Lösungen zur Spannungsregelung in Verteilernetzen

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

14 October 09 Vas Kandiah AOQ SSMBB

Dominion Energy Instructional Guide for Completing Virginia Form NMIN

magellan solar export control solutions Magellan Power Solar Gate

PV Development and Grid Access Study for a Club Resort in Indonesia

Small DER Aggregation Example

ANCILLARY SERVICES WITH VRE (VARIABLE RENEWABLE ENERGY): FOCUS PV

Transcription:

SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Phone: +49 561 9522-0 Fax: +49 561 9522-100 Internet: www.sma.de E-Mail: info@sma.de Amtsgericht (District court) Kassel HRB (registration number) 3972 Vorsitzender des Aufsichtsrats (Chairman of the Supervisory Board): Dr. Erik Ehrentraut Managing Board: Ulrich Hadding, Dr.-Ing. Jürgen Reinert, Pierre-Pascal Urbon SMA Export Control Solution 1 System Description The SMA export control solution measures the active power at the point where the customer s installation is connected to the distribution system (point of grid connection) and then uses this information to either restrict generation output and/or balance the customers demand in order to prevent the export to the distribution system from exceeding the agreed export capacity. The agreed export capacity may be configured as an active power value (in kw or MW) and applied as limit for the net export amount across all phases. The SMA export control solution is designed fail-safe. If one component fails, the active power exported across the point of grid connection will remain at the agreed export capacity or less. Therefore the fallback function monitors every communication path within the control circuit and controls the behavior in the event of a communication failure. In addition to this agreed export capacity, the distribution network operator will specify an export power factor or power factor range at the point of grid connection, as applicable. The export control solution is designed to measure and limit the active power only since the power factor and hence the apparent power and reactive power should be controlled by the customer to satisfy the requirements of the connection agreement. The following diagram illustrates the export control scheme. HK_ENA_EREC_G100_en_11 1/6

2 Solution Configurations The SMA export control solution consists of an SMA power controller, a compatible meter at the point of grid connection and compatible SMA inverters. The following table gives an overview of possible system solutions. Please refer to section 3 for block diagrams of the referenced system schemes and section 4 for a description of the system components. # Scheme Power Controller Electricity Meter Inverters 1 A No additional hardware, export control function is integrated in inverter EMETER-20 SMA Solar Inverter with integrated export control function. E.g.: SB 3600SE-10/SB 5000SE-10 STP 50-40 SB 3.0-1AV-40/SB 3.6-1AV-40 SB 4.0-1AV-40/SB 5.0-1AV-40 SB1.5-1VL-40/SB 2.5-1VL-40 2 B HM-20 No additional hardware, electricity metering function is integrated in HM-20. 3 C EDMM-10 EMETER-10, EMETER-20 or Janitza UMG 604 Up to 4 SMA Solar Inverters with Speedwire/Webconnect interface Up to 25 SMA Solar Inverters with Speedwire/Webconnect interface 4 C IM-20 Janitza UMG 604 Up to 42 SMA Solar Inverters of the following types: Abbreviations: EDMM = SMA Data Manager; HM = Sunny Home Manager; IM = Inverter Manager SB = Sunny Boy; STP = Sunny Tripower; SHP = Sunny Highpower E-METER = SMA Energy Meter STP 60-10 SHP 75-10 HK_ENA_EREC_G100_en_11 2/6

3 System Schemes Scheme A - Inverter integrated export control Scheme B - Meter integrated export control Scheme C - External power controller HK_ENA_EREC_G100_en_11 3/6

4 System Components 4.1 The Electricity Meter The Electricity Meter measures and calculates phase-exact and balanced electrical measured values and makes them available via Ethernet in the local network. In this way, the export controller has access to precisely and fast sampled data on grid feed-in (export) and purchased electricity (import). Please refer to the appropriate data sheets of the meter to make sure that the meter is suitable for your application. E.g. The SMA Energy Meter EMETER-20 is a bidirectional meter that communicates the measured values to the export controller via Speedwire (Ethernet cable) every second. This meter can be used for single-phase or three-phase systems and its maximum current is 63A (external current transformers may be used when the current exceeds this value). Note: The HM-20 has built in functionality of EMETER-20. 4.2 The Power Controller If the balance between generation and consumption reaches a point where the system might export more than the agreed export capacity, then the export control function de-rates the inverters and turns down their production (PV inverters regulate the MPP to match new AC output power level limit). With this solution the amount of power that the PV system generates is maximized matching exactly the local power demand plus the maximum export power. If required, the export controller can be configured to limit the exported power down to 0%. This export control function is implemented by various SMA products, e.g. HM-20, EDMM-10 and some solar inverters 4.3 The Solar Inverter The inverters with Fallback function and Speedwire/Webconnect interface and therefore compatible with export limitation are the following: Solar Inverter Firmware Speedwire/Webconnect Integrated export control STP 5000TL-20 STP 6000TL-20 STP 7000TL-20 STP 8000TL-20 STP 9000TL-20 STP 10000TL-20 STP 12000TL-20 STP 20000TL-30 STP 25000TL-30 from V2.52.02.R Yes No - Yes, with SWDM-10 No STP 50-40 - Yes Yes SB3.0-1AV-40 SB3.6-1AV-40 SB4.0-1AV-40 SB5.0-1AV-40 SB1.5-1VL-40 SB2.5-1VL-40 STP 60-10 SHP 75-10 - Yes Yes - Yes Yes - No, for use with IM-20 only. No, for use with IM-20 only. HK_ENA_EREC_G100_en_11 4/6

5 Test Results The following charts illustrate the typical power export response to load steps for several system configurations. The results are applicable to other system configurations expecting the same results as the limitation is done following the same procedure. 5.1 Test Results for EDMM-10, EMETER-20 and SB 5000TL-21 5.2 Test Results for HM-20 and SB3.6-1AV-40 HK_ENA_EREC_G100_en_11 5/6

SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Phone: +49 561 9522-0 Fax: +49 561 9522-100 Internet: www.sma.de E-Mail: info@sma.de Amtsgericht (District court) Kassel HRB (registration number) 3972 Vorsitzender des Aufsichtsrats (Chairman of the Supervisory Board): Dr. Erik Ehrentraut Managing Board: Ulrich Hadding, Dr.-Ing. Jürgen Reinert, Pierre-Pascal Urbon Manufacturer s Declaration Compliance with ENA EREC G100 requirements UK DNO s require a fail-safe system, hard wired communications between the components of the export limiter system, specific power quality and operational time. Requirement: The scheme has hard wired communication links between the various component parts of the export limitation scheme. Compliance: The communication between the different components (Inverters, electricity meter and power controller) is via Speedwire (Ethernet cable RJ45). Not wireless connections. Requirement: The export limitation scheme operates signals to the generation to reduce output within 1 second. Compliance: The electricity meters listed under section 4.1 transmit measurement values, one averaged value per second to the power controller listed under section 4.2. The power controller sends new set-points for the AC power output to connected inverters. Requirement: The scheme is fail-safe and limits export if the export limiter fails or it loses its power supply. Compliance: The SMA export control solution is designed fail-safe. If the electricity meter or the power controller fails, the active power exported across the point of grid connection will remain at the agreed export capacity or less. Therefore the fallback function monitors every relevant communication path within the control circuit and controls the behavior in the event of a communication failure. The fallback function is realized by the power controller and all inverters listed in section 4.3. Requirement: The scheme complies with ENA Engineering Recommendation G5 for harmonics, P28 for flicker and P29 for voltage unbalance. Compliance: same as a system which is not limited. Please, check specific G83 and G59 certificates of our SMA inverters in our website www.sma-uk.com in Downloads area. Requirement: When the export limitation scheme operates it will reduce the exported active power to a value equal to, or less than, the Agreed Export capacity. Compliance: power export peaks of typical load steps are limited by the export control circuit within 5 sec. See test results in section 5. Note: In order to operate a 0-watt closed-loop control with the PV system, it is required to operate a base load (selfconsumption) of at least 0.5 % of the rated output power of the solar inverters. Niestetal, 27.04.2018 SMA Solar Technology AG ppa. Dr.-Ing. Johannes Kneip EVP Development Center HK_ENA_EREC_G100_en_11 6/6