Eclipse Hermetic Gas Boosters

Similar documents
Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

2.0 Burner Operating Parameters and Requirements

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION CENTRIFUGAL HVAC FANS

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

SECTION HVAC POWER VENTILATORS

SECTION AXIAL HVAC FANS

ECLIPSE TURBO BLOWERS SERIES SMJ


Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

University of Delaware

Tubular Centrifugal Fans

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS. Frames 143T - 449T

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

AC Induction Motors. Installation and operating instructions

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

SECTION MOTOR REQUIREMENTS for HVAC

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

R-22, 13 SEER 60 Hertz

DESIGN GUIDELINES FANS PAGE 1 of 7

ECLIPSE TURBO BLOWERS SERIES SMJ

SECTION AIR TERMINAL UNITS

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

University of Houston Master Construction Specifications Insert Project Name

WAC Air Curtains Technical Guide

Generator Fire Safety: Generator assemblies should be located outside the building.

END SUCTION CENTRIFUGAL PUMPS

2 Saudi Fan Industries

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

Climas y Proyectos Leyco, S.A. de C.V.

Contents Project: Model: Chk d: Date:

D-Series Blowers and Exhausters

AXIAD II Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Regenerative Turbine Pumps

Multi-Institutional Academic Health Science & Research Center Evansville, IN

W4100, W4200 & W4300 Electric Pump

User s Manual D-Series Blowers and Exhausters

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

TYPE PC Propeller Condensate Pumps

SECTION OWNER FURNISHED EQUIPMENT

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

TGIF-3. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Regenerative Turbine Pumps

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

PRODUCT: 1500 SERIES MOBILE EXPLOSION PROOF PAGE 1 REV "BLADE MASTER" AC-EP-SINGLE PHASE-1.5 HP OPERATING AND MAINTENANCE INSTRUCTIONS

Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

DARTMOUTH COLLEGE DESIGN February 15, 2006 & CONSTRUCTION GUIDELINES

Eclipse AutoTite Automatic Gas Shut-Off Valves

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

TECHNICAL BROCHURE B5-18SB R1 5SB, 7SB, 10SB & 18SB 5-18 GPM, ½ 1½ HP, 60 HZ SUBMERSIBLE PUMPS

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

PERFORMANCE DATA 3-PHASE INDUCTION MOTOR

Centrifugal Utility Fans - SFD/SFB

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Warning. Document ref: A October 2015

Consider The Possibilities...

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

ROTO-CON RONK ELECTRICAL INDUSTRIES, INC. NOKOMIS, IL FIELD INSTALLATION & OPERATION INSTRUCTIONS

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

Contents. Identification

M50 L50 Series Multistage Regenerative Turbine Pumps

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Regenerative Turbine Pumps

ACE Variable Frequency Drive System

READ AND SAVE THESE INSTRUCTIONS

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Series Base mounted pump. Installation and operating instructions

EXHAUST FANS CUD & CUB UPBLAST FANS

Design and Application Details

Series CC Condensate Units

JABSCO & Series 1½ 80 SIZE UTILITY Pump

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

ITT. Goulds Pumps G&L Series NPO. Engineered for life. Commercial Water. Open Impeller All Stainless Steel End Suction Pumps.

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

SeasonPak Packaged Air-Cooled Water Chiller

Tube Axial Fan Page Specifications & Dimension Data Performance Data

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

END SUCTION CENTRIFUGAL PUMPS

SERIES PC INSTRUCTION AND OPERATION MANUAL

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

Modifiable TITAN Horizontal Motors Accessories and Modifications

SECTION MOTOR CONTROL

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

Transcription:

Information Guide 620 12/1/2008 Eclipse Hermetic Gas Boosters Series HB & HBLC Version 1

Applications Eclipse Inc., produces a line of single stage, centrifugal type, hermetically sealed gas boosters for use in gas piping systems, not corrosive to aluminum or steel. These gas boosters are used in applications where it is necessary to increase the line pressure above the available distribution system. They are designed and constructed to provide a volume of gas of a defined specific gravity (at standard temperature and pressure) compressed to a relatively constant pressure. The hermetic gas booster is a self contained unit. It has a 3600 rpm synchronous speed, explosion proof motor which is UL listed for use in Class I, Group D hazardous locations. The impeller is mounted directly onto the motor shaft. The motor and fan are completely enclosed in a sealed steel casing which includes the wires in the conduit, to prevent gas from leaking into the surrounding environment. Electrical connections for the motor are made in a junction box mounted on the outside of the casing. The discharge pressure is the total of the booster added pressure plus incoming gas pressure. Example: If the inlet pressure is 4" w.c. and the booster produces 14" w.c., then the outlet static pressure will be 18" w.c. The flow pressure curve for each booster is a function of the gas density, inlet and outlet diameters, impeller size (diameter and width) and motor rating. The outlet pressure varies throughout the gas flow range normally peaking at an intermediate flow then dropping off at the higher flow. The volumetric flow is not affected by changes in the gas density but the pressure and horsepower consumed are as shown in the following equation: D 2 SG 2 P 2 HP 2 = = = D 1 SG 1 P 1 HP 1 D = Density, SG = Specific Gravity, P = Outlet Pressure, HP = Horsepower (consumed) When incorporating a gas booster into a system, the use of a flow control device, such as a butterfly valve, is necessary to control the outlet flow to prevent the unit from exceeding the rated horsepower (current draw) of the motor. System designs should always include a pressure factor to ensure that adequate pressure will be available. Flow pressure curves should be used for reference if pressure margins are limited. Refer to Datasheet 620 for specifications relating to application flow and turndown. Installation Location Position the booster with respect to the service entrance as required by local codes or the authority having jurisdiction. Install booster in an accessible location on a level concrete floor or other substantial mounting pad. Provide enough space between the booster terminal box and the nearest obstruction to allow removal of the internal assembly for maintenance purposes. The space required is shown in Datasheet 620 as dimension N. Level Housing Be sure the top of the booster housing is level to avoid excessive wear of motor bearings. Bolting Booster to Base Booster should be bolted to mounting pad through mounting holes provided in booster base. If desired, vibration pads may be installed under base. If mounted rigid to mounting pad, avoid twisting the booster base when bolting down. Shim properly before tightening the mounting bolts. Piping Shut Off Eclipse Hermetic Gas Pressure Booster Gas Outlet Union or Flange PG Union or Flange Shut Off Shut Off (Bypass Normally Closed) LowGas Pressure Switch Check Service Gas Inlet Figure 1. Typical Piping Arrangement Reduce Piping Bends Hermetic boosters are available in various outlet positions so that a minimum number of piping bends is required. Bottom horizontal discharge and standard rotation, CCW as viewed from motor side, is supplied unless otherwise specified during ordering. Types of Piping and Fittings Avoid pipe bends within 5 pipe diameters of the outlet. Use rigid piping to prevent gas leakage, excessive power consumption and possible power hazard. Use solid pipe connections, either threaded or flanged, at booster inlet and outlet. Check to insure that all fittings are tight and piping is not leaking. Piping Support DO NOT use the booster to support piping. Use suitable brackets or hangers. Place the booster as close as possible to the appliance to minimize piping pressure losses. Low Gas Inlet Pressure Local utilities typically require installation of a gas pressure switch on the inlet. It is used to prevent booster operation when the utility supply pressure is too low. The utility specifies the setting. 2 Eclipse Hermetic Gas Boosters, V1, Info Guide 620, 12/1/2008

Pipe Size Use the appropriate pipe size from the booster to the appliance to avoid excessive pressure losses, see Datasheet 620. Avoid sharp bends and pipe constrictions. Test or Inlet Pressure Inlet or test pressure must not exceed 5 psig. Electrical Characteristics Check Booster Nameplate Before making any electrical connections, compare the electrical circuit characteristics to those of the motor to verify that they are the same. See specifications on the booster nameplate (see Figure 2 and Figure 3 for nameplate location). Meeting Electrical Codes Local electrical codes and regulations covering motor starter, switches and controls vary. Have a reliable electrical contractor install the proper switch or starter and make the necessary electrical connections. Protect the Motor Baldor motors are used on all Eclipse Hermetic gas boosters. They are UL listed Class 1, Group D and explosion proof. When wiring the booster motor, it is essential that it be properly protected against overload and excessive heat conditions (refer to Figure 4 for suggested wiring). Motor Starter Overload Be certain that the motor starter overload protection is correct for power requirements. Verifying Fan Rotation Be certain that the fan rotates properly so the blades travel towards the booster outlet. If necessary, remove the 1" rotation inspection plug from the booster end plate; momentarily start the motor and observe the fan rotation. Replace the rotation inspection plug after fan rotation has been determined (see Figure 2 and Figure 3 for rotation inspection plug location). Terminal Terminal Rotation HERMETIC BOOSTER Name Plate End View Flange Gasket (UL Listed Material) Retaining Spring Motor End Plate Front Housing Cover Back View (Motor Side) A Rotation Inspection Plug 1" NPT Rotor Inlet Outlet Motor Housing Section A-A A Front View Figure 2. Parts Identification & Location - HB Series Eclipse Hermetic Gas Boosters, V1, Info Guide 620, 12/1/2008 3

Terminal HERMETIC BOOSTER Name Plate End Plate Inlet Motor Fan Housing Plate Rotation Inspection Plug 1" NPT Terminal Rotor Slot Size 5/8" x 7/8" Outlet Motor Housing Maintenance Special Lubrication Requirement NEMA Frame Size * These motors have sealed bearings which are factory lubricated for normal bearing life. ** Motors with seasonal use (approximately 6 months) should be serviced at the beginning of the season. NOTE: The motor bearings should be relubricated with either Dow Corning FS-3451 silicone grease or Christo- Lube MCG-134 grease (#2 consistency) at the intervals noted in the above table. Motor lubrication is identified on a tag attached adjacent to the booster ID tag. Motors lubricated with Christo-Lube are also identified on the motor nameplate. Relubrication can be done on-site or at any authorized Baldor Service Center. Be certain to identify the correct grease to the service center. Contact Figure 3. Parts Identification and Location - HBLC Series Recommended Relubrication Intervals (hrs) Up to 74 F Ambient 75 to 122 F Ambient or Corrosive Gas Up to 180 * * Up thru 210 5500** 2750** Over 210 3500** 1800** Lubrication Technology Inc., at (800) 477-8704 for Christo-Lube MCG-134 grease. Reference use in Baldor motors when ordering. Grease is available in 1 lb containers (approximately 8 fluid ounces). Removing the Internal Assembly Motor and rotor are easily accessible by unbolting the end plate and sliding the entire motor and rotor assembly out of the housing. On the HBLC-3316-3/4 Booster, you must unbolt end plate and fan housing plate, remove set screws on rotor with long handled socket tool, remove the rotor, and then slide motor assembly out. The entire internal assembly is easily removed from the booster for motor and rotor inspection and/or maintenance. NOTE: To insure that the booster is properly sealed when reassembled, a spare flange gasket should be ordered and used (refer to the table for ordering information). To remove the internal assembly, use the following procedures (see Figure 2 and Figure 3 for part identification): Be certain that the gas, air and electricity are shut off before disassembly. 4 Eclipse Hermetic Gas Boosters, V1, Info Guide 620, 12/1/2008

Remove end plate bolts. For the HBLC also remove the fan housing bolts, set screws and rotor. Carefully slide out entire internal assembly. Be careful not to damage or upset rotor balance. DO NOT disturb wiring conduit or terminal box position as this will break the gas seal and result in gas leakage. When reassembling the internal assembly, install a new flange gasket. Part Number Uncut Gasket Ordering Information Amount Needed (Sq. Ft.) Fan Diameter (Inches) 38005 4 up to 15 38005 9 17 or over Pre-Cut Gasket Ordering Information HB Model Part Number Quantity HB-3412-1/2 14093 1 HB-4412-1/2 14093 1 HB-4412-1 14093 1 HB-3314-1/2 14093 1 HB-4414-1 14093 1 HB-4614-1 14019 1 HB-4614-1-1/2 14019 1 HB-4615-1 14019 1 HB-6615-1-1/2 16800 1 HB-6615-2 16800 1 HB-4617-1 13823 1 HB-4617-1-1/2 13823 1 HB-6617-2 13823 1 HB-6617-3 14793 1 HB-8817-5 16558 1 HB-4619-1-1/2 14222 1 HB-4619-2 14222 1 HB-6619-3 14222 1 HB-6619-5 17959 1 HB-8819-7-1/2 15353 1 HB-8819-10 15353 1 HB-4623-3 16558 1 HB-4623-5 16558 1 HB-6623-7-1/2 14377 1 HB-6623-10 14377 1 HB-8823-15 14377 1 HB-8823-20 14377 1 HB-4628-5 13734 1 HB-4628-7-1/2 13734 1 HB-4628-10 13734 1 HB-8828-10 13734 1 HB-8828-15 13734 1 HB-8828-20 13734 1 HB-LC-3316-3/4 14549 2 Relubrication Procedure Applicable for 3 Hp and larger motors lubricated with Christo-Lube MCG-134 grease only. Motors 2 Hp and smaller have sealed bearings which are factory lubricated for normal bearing life. Motors with Dow Corning FS-3451 grease do not contain grease fittings. Clean the grease fittings. Remove the grease outlet plugs. Add recommended amount of Christo-Lube MCG-134 grease. Stop when new grease appears at the shaft hole in the end plate or at the outlet plug hole. Approximate grease amounts for each bearing are: -.33 fluid oz. for 3 to 5 Hp motors (up to 210 NEMA frame) -.66 fluid oz. for 7.5 Hp and larger motors (over 210 NEMA frame) Clean up excess grease and replace outlet plugs. Storage and Shutdown The following recommendations will minimize potential damage to equipment when the unit will not be operating for long periods or when the unit will be put into storage: 1. Inspect the booster for external damage, paint chips, damaged seals, and repair as required. 2. Lubricate the motor bearings if the unit has operated more than half of the recommended time interval specified in Maintenance. 3. Guard against corrosive elements contained within the hermetic volume of the booster. - If the booster is removed from the piping system, insure that the contained volume is dry and inert and then seal off both the inlet and outlet. - In the case where a booster system has been operating on clean dry natural gas and will not be removed, simply close the inlet and outlet valves to isolate any moisture incursions. - In the case of gas with corrosive content, such as hydrogen sulfide in natural gas, then the hermetic volume must be purged with a dry inert gas before sealing. 4. When putting the system back into operation, the motor insulation integrity should be tested with a "Megger Insulation Tester", and the bearings must be relubricated. Problems or Questions Call your local Eclipse office for any required assistance or for recommended spare parts. Eclipse Hermetic Gas Boosters, V1, Info Guide 620, 12/1/2008 5

To Suitable Power Source Notes: L1 L2 L3 Step Down Transformer or Control Voltage Power Supply of Adequate Supply X2 High Voltage Low Voltage 1. Motor Phase Wiring X1 Fuse Stop Properly Sized Motor Starter Start For three phase: Three black wires for T1, T2 & T3. For 115V, single phase: One black wire to T1 and one white wire to T2. For 230V, single phase: One black wire to T1 and one red wire to T2. Internal Wiring of HB Booster Eclipse will internally wire only the HB Booster for the customer specified voltage and bring out the minimum number of necessary connecting wires to a termination box. M M-OL M-OL M-OL M T1 T2 T3 (See Note 1) Regarding Motor Phase Wiring & Internal Wiring Low Inlet Gas Pressure (See Note 3) Figure 4. Suggested Wiring 2. P1 and P2 Wires Two red wires labeled P1 and P2 are normally closed thermostat wires that will open when the motor winding temperature rises above its design limit. The M motor starter will de-energize. It is the customer s responsibility to wire P1 or P2 into any control circuit as shown. The P1 and P2 wires do not exist on some motors, such as 1/2 Hp, 3/4 Hp, and special ordered types. Without these, the circuit must be wired with the jumper. 3. Inlet Gas Pressure Switch Low inlet gas pressure switch closes when the inlet gas pressure is above the minimum acceptable pressure specified by the local utility company. 4. Wiring Standards P1 P2 (See Note 2) Jumper (If P1 & P2 do not exist) HB Booster Motor Class 1, Group D (UL Listed) M-OL (3) Frame (Ground) Bonding Wire (to be furnished and attached by installer) Motor Starter Coil (To match control voltage power supply) Inspection Hole (To determine proper rotation) All wiring and installation must conform with national and local electrical codes. All of the booster s external wiring and wiring of the equipment is the customer s responsibility unless otherwise specified. M Information Guide 620 12/1/2008

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (804) 236-3882 www.peconet.com