Technical data Smart chargers Lifetech XFC TM
Lifetech XFC TM Hawker XFC TM will transform the way you work forever! The new Hawker Lifetech XFC series covers single phase and three phase chargers, 4 V to 7 V. It has been developed to meet the need for a cost effective and efficient charger with a specific XFC charging profile allowing full recharge less than 5 hours at 60% DOD C 5. These multicapacity chargers offer key features in corpora - ting the cost saving benefits of HF technology. The design is optimised in terms of weight and size. The high value polymer ABS flame retardant enclosure reflects the innovative energy converting technology. This new range is a further extension of the wide portfolio of HF chargers and a result of the EnerSys long term experience, technology leadership and development capability. Main technical features Precise recharge according to DOD Temperature adjustment by switch (only from 4 V 50 A) High power factor and efficiency reducing energy consumption of the battery Options: Remote display (green/red) (from 4 V 50 A) Serial link for charger memory download (from 4 V 50 A) Front panels LED display : Indicating the evolution of the state of charge LCD display : Showing all charging parameters : total voltage, cell voltage, current, capacity restored, charging time, % of charge, time remaining.... Memorization of parameters. 5 4 5 Model Model Model Model 4 Ref. Function Ref. Function Start-Stop or Stop/Start switch. Green light : state of charge. Unlit: charger stopped or battery not available. Flashing: thermal fault. Permanently lit: battery available. Red Fault light. Unlit: charger stopped or battery not charging. 4 5 Flashing: charger fault. Permanently lit: Charging in progress. LCD display. Button for exiting the menu, initiating equalisation and initiating desulphation charging.
Hawker Lifetech XFC TM Charger Selection Table Matching table of capacity & recharge time Charging rate (C 5 ) 0.4 0.5 0.6 0.7 0.8 0.9 Recharge time in hours for a 60% discharged battery (hrs).5.75.5.5.5 Recharge time in hours for a 80% discharged battery (hrs).5.5.75.5.5 4 Volt Capacity in Ah/C 5 to be recharged within... hours. TC LT 4 V 0 A 50 40 9 5 0 TC LT 4 V 5 A 6 50 4 6 8 5 TC LT 4 V 0 A 75 60 50 4 8 0 TC LT 4 V 5 A 88 70 58 50 44 9 5 TC LT 4 V 40 A 00 80 67 57 50 44 40 TC LT 4 V 50 A 5 00 8 7 6 56 50 TC LT 4 V 60 A 50 0 00 86 75 67 60 TC LT 4 V 70 A 75 40 7 00 88 78 70 TC LT 4 V 80 A 00 60 4 00 89 80 TC LT 4 V 00 A 50 00 67 4 5 00 TC LT 4 V 70 A 75 40 7 00 88 78 70 TC LT 4 V 0 A 00 40 00 7 50 0 TC LT 4 V 40 A 50 80 00 75 56 40 TC LT 4 V 00 A 500 400 86 50 00 6 Volt Capacity in Ah/C 5 to be recharged within... hours. TC LT 6 V 0 A 75 60 50 4 8 0 TC LT 6 V 40 A 00 80 67 57 50 44 40 TC LT 6 V 50 A 5 00 8 7 6 56 50 TC LT 6 V 60 A 50 0 00 86 75 67 60 TC LT 6 V 70 A 75 40 7 00 88 78 70 TC LT 6 V 80 A 00 60 4 00 89 80 TC LT 6 V 00 A 50 00 67 4 5 00 TC LT 6 V 5 A 88 0 9 64 44 8 5 48 Volt Capacity in Ah/C 5 to be recharged within... hours. TC LT 48 V 50 A 5 00 8 7 6 56 50 TC LT 48 V 70 A 75 40 7 00 88 78 70 TC LT 48 V 00 A 50 00 67 4 5 00 TC LT 48 V 60 A 50 0 00 86 75 67 60 TC LT 48 V 75 A 88 50 5 07 94 8 75 TC LT 48 V 00 A 50 00 67 4 5 00 TC LT 48 V 5 A 88 0 9 64 44 8 5 TC LT 48 V 40 A 50 80 00 75 56 40 TC LT 48 V 70 A 45 40 8 4 89 70 TC LT 48 V 00 A 500 400 86 50 00 TC LT 48 V 40 A 600 480 400 4 00 67 40 7 Volt Capacity in Ah/C 5 to be recharged within... hours. TC LT 7 V 05 A 6 0 75 50 7 05
Technical parameters Lifetech XFC TM Range Unit 4V 0A 4V 5A 4V 0A 4V 5A 4V 40A 4V 50A 4V 60A 4V 70A 4V 80A 4V 00A 4V 70A 4V 0A 4V 40A 4V 00A -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase V 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 400 ±0% 400 ±0% 400 ±0% 400 ±0% Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 consumption A 4.8 6 7. 8.4 9.5 7.5 9 0.5 4.5.4 5.8 6.8 9.7 cable mm x.5 x.5 x.5 x.5 x.5 x.5 x.5 x.5 x.5 x.5 4 x.5 4 x.5 4 x.5 4 x.5 fuse (Protistor) A 6 6 6 6 6 0 0 0 0 0 0 0 0 0 mm 6 6 6 6 6 0 6 6 6 5 5 5 5 50 length. m to 0 to 0 to 0 to 0 level IP IP IP IP IP IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 T. of use C 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to+40 0 to+40 0 to +40 0 to +40 Weight kg 4 4 4 4 4 0 0 0 8 8 8 55 Dimensions Height mm 85 85 85 85 85 50 50 50 50 50 58 58 58 940 Length mm 6 6 6 6 6 88 88 88 88 88 89 89 89 40 Depth mm 0 0 0 0 0 46 46 46 46 46 80 80 80 7 Height mm 7 7 7 7 7 470 470 470 470 470 548 548 548 540 Width mm 0 0 0 0 0 0 0 0 94 Front panel LED LED LED LED LED LED LED LED LED LED LED LED LED LCD Unit 6 V 0A 6 V 40A 6 V 50A 6 V 60A 6 V 70A 6 V 80A 6 V 00A 6 V 5A -phase -phase -phase -phase -phase -phase -phase -phase V 0±0% 0±0% 0±0% 0±0% 0±0% 0±0% 400 ±0% 400 ±0% Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 consumption A 9.5 8.8. 5.4 7.6 7. 8.4 cable mm x.5 x.5 x.5 x.5 x.5 x.5 4 x.5 4 x.5 fuse (Protistor) A 6 0 0 0 0 0 0 0 mm 6 0 0 6 6 6 5 5 length. m to 0 to 0 level IP IP0 IP0 IP0 IP0 IP0 IP0 IP0 T. of use C 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 Weight kg 4 0 0 8 8 Dimension Height mm 85 50 50 50 50 50 58 58 Length mm 6 88 88 88 88 88 89 89 Depth mm 0 46 46 46 46 46 80 80 (out of cable) Height mm 7 470 470 470 470 470 548 548 Width mm 0 0 0 0 0 0 0 Front panel LED LED LED LED LED LED LED LED
Unit 48 V 0 A 48 V 40 A 48 V 50 A 48 V 70 A 48 V 00A 48V 60A 48V 75 A 48V 00 A 48 V 5A 48 V 40A 48 V 70A 48V 00A 48V 40A -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase -phase V 0 ±0% 0 ±0% 0 ±0% 0 ±0% 0 ±0% 400 ±0% 400 ±0% 400 ±0% 400 ±0% 400 ±0% 400 ±0% 400 ±0% 400 ±0% Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 consumption A 9 4.5 0 5.8 7. 9.7.6 6.5 9.4. cable mm x.5 x.5 x.5 x 4 x 6 4 x.5 4 x.5 4 x.5 4 x.5 4 x.5 4 x 4 4 x 6 4 x 6 fuse (Protistor) A 0 0 0 0 50 0 0 0 0 0 0 0 40 mm 0 0 0 5 5 6 6 5 5 5 50 50 50 length. m to 0 to 0 to 0 to 0 to 0 to 0 to 0 to 0 to 0 to 0 to 0 to 0 level IP IP IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 T. of use C 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 0 to +40 Weight kg 0 55 8 8 8 8 8 55 55 55 Dimensions Height mm 77 4 50 600 940 58 58 58 58 58 940 940 940 Length mm 8 7 88 40 40 89 89 89 89 89 40 40 40 Depth mm 86 06 46 7 7 80 80 80 80 80 7 7 7 (out of cable) Height mm 80 55 470 90 540 548 548 548 548 548 540 540 540 Width mm 68 04 0 94 94 0 0 0 0 0 94 94 94 Front panel LED LED LED LCD LCD LED LED LED LED LCD LCD LCD LCD Unit 7 V 05 A -phase V 400 ±0% Frequency Hz 50/60 consumption A 5. cable mm 4 x 4 fuse (Protistor) A 0 mm 50 length. m to 0 level IP0 T. of use C 0 to +40 Weight kg 55 Dimensions Height mm 940 Length mm 40 Depth mm 7 Height mm 540 Width mm 94 Front panel LCD
Wherever you do business, EnerSys can support you with motive power energy. The Hawker branded battery range, matched chargers and systems provide trouble free perfor mance under the most demanding service conditions. Our strategically located manufacturing plants are efficient and responsive with a culture of continuous improvement and added value for our business partners. EnerSys has an enviable position in technology leader ship and with significant investment in research and development we intend to stay at the leading edge in product innovation. The recently developed energy solutions: Hawker XFC TM and Water Less 0 batteries, Lifetech and LifeSpeed IQ TM HF chargers, have defined new benefits for our customers: faster recharge, more machine availability, lower operating and investment costs, reduced carbon footprint. Our team of development engineers is driven by the desire to build the best energy solutions and works closely with our customers and suppliers to identify development opportunities. Our bias for rapid innova - tion means we get new products to market fast. EnerSys's integrated sales and service network is dedicated to providing our customers with the best solutions and after-sales support for their business. Whether you require battery or a complete fleet of batteries, chargers, a battery handling system and a state of the art fleet management system, you can count on us. EnerSys is the world's largest industrial battery manufacturer and we are dedicated to being the best. European Headquarters: EnerSys EMEA EH Europe GmbH Löwenstrasse 800 Zürich Switzerland Phone: +4 44 5 74 0 Fax: +4 44 5 74 Local contact: Enersys Ltd Oak Court Clifton Business Park Wynne Avenue Swinton Manchester M7 8FF Phone: 06 794 46 Fax: 06 77 809 Please refer to the website address for details of your nearest EnerSys office: www.enersys-emea.com 0 EnerSys. All rights reserved. All trademarks and logos are the property of or licensed to EnerSys and its affiliates unless otherwise noted. 04.0 Subject to revisions without prior notice. E&OE