The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Similar documents
SECTION MOTOR CONTROL

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Softstarters Type PSS. Softstarters. General information

Application Description

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

RVS-AX Instruction Manual

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Dimensions WxHxD [mm] Weight [kg]

Altistart 22 & Enclosed Altistart 22 soft starters

SOLSTART Instruction Manual

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

EPS-ECONOMY PUMP STARTER

RVS-DN Digital Reduced Voltage Motor Starter

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

RVS-DX Digital Reduced Voltage Motor Starter

Customized drive solutions

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Altistart 48 Y-Range Soft Start Controllers Installation Guide


CTi Automation - Phone: Fax: Web:

LH4 Modular Soft Start

Altistart 48 Enclosed Soft Start Controllers hp, 600 V; hp, 480 V; hp, 240 V or hp, 208 V Class 8638 and 8639

PSE The efficient range Description

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Product Description. Application Description

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

HVW701 HVAC Drive with By-Pass

Enclosed Full-Voltage Starters

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

MCD 200 Series Soft Starters

TDX - Taco Duplex Starter with

3. Coils shall be of molded construction

Hp V AC Current Rating [A] 230V AC 60 Hz

Altivar 660 Drive Systems

Enclosed Full-Voltage Starters

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Altistart 22 soft start/soft stop units

Softstarters PSR PSS PST Extreme duty

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Altistart 01 soft starters

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

BAC Custom Engineered Controls

Enclosures. See Section Typical Description

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

GPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor

SECTION VARIABLE FREQUENCY DRIVE UNITS

ALTIVAR 58 AC Drives

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Reduced Voltage Starters Section 2

Altivar 212 Drive. A variable speed AC drive for 1 to 100 HP, three-phase asynchronous motors. Make the most of your energy SM

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Features and Benefits. Control Features

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Motorpact Medium Voltage Motor Controller. Innovative solutions that deliver high performance and reliability

Starts, stops and protects. Emotron TSA Softstarter

Softstarter Intelligent Controllers

Reduced Voltage Motor Starters

GPH2 Combination Soft Starters

NEMA Contactors & Starters (Freedom)

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

EPS-ECONOMY PUMP STARTER

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Intelligent Softstarter Controllers

Submittal Data Information

Softstarters Type PSR. Softstarters

Delta Products VFD CP2000 Bypass Control Packages.

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Softstarters Softstarters

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

MAGNETIC MOTOR STARTERS

Soft starters Altistart 01 The starting solution

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

SSW07. Soft Starters. Applications. Standard Features

SECTION MOTORS & MOTOR CONTROLLERS

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

152H F480 F BD B 59 8B

AF series contactors (9 2650)

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Transcription:

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the most of your energy SM

Get more from your solution with the Enclosed Altistart 22 soft start/ soft stop motor controller Features include: Mid-range enclosed soft starter Low cost and space-saving design with integrated bypass function Easy start-up Integrated controls included within the enclosures Optimized with a circuit breaker disconnect, pilot devices, control logic, signal relaying and selectable options designed to meet application requirements up to 125 hp at 480 V UL Type 1, 12 and 3R enclosure ratings UL listed combination motor controller (UL 508) Coordinated short circuit current rating of 100 ka at 480 V and 50 ka at 600 V Service entrance rating Automatic remote starting 2

Extend the service life of your machines The Enclosed Altistart 22 solid-state combination motor controllers provide a pre-engineered, integrated solution for reduced voltage starting and soft stopping of standard three-phase asynchronous induction (squirrel cage) motors. The Enclosed controllers consist of a circuit breaker disconnect and an Altistart 22 soft starter in a stand-alone enclosure. With its energy efficient features, such as reduced current inrush, reduced voltage drop and mechanical shock at motor start and stop, the Enclosed Altistart 22 controller offers an ideal solution for your basic motor control needs, including: A six thyristor (SCR) solid-state power configuration providing smooth acceleration and deceleration control of three-phase squirrel cage motors Control algorithms that are integrated to ensure smooth rotation throughout the starting ramp without mechanical instability at the end of starting An integral shorting contactor to reduce steady state controller operational losses 3

Achieve greater energy efficiency with simple system integration and control The Enclosed Altistart 22 combination motor controller combines integrated bypass and control components that improve your machine s performance and reliability and cut installation costs. If you need an economical controller that is suited for harsh environments, the Enclosed Altistart 22 combination motor controller is an ideal choice. Less wiring, more saving Integrated bypass reduces the number of external components: power wiring, contactor and control wiring for coil Wiring six terminals instead of twelve saves time and money Integrated bypass contactor decreases heat dissipation, allowing for a smaller enclosure Conformal coated printed circuit boards provide enhanced resistance to harsh environments, increasing the service life of your installation and reducing maintenance costs Improve your machine s performance, protect the motor and reduce down time True three-phase control combined with other protection functions allow you to monitor and protect your machine to improve up time The soft start and soft stop control reduces mechanical stress on the motor and machine components to increase its productive life:» For the motor delivers thermal protection by calculation, with phase loss detection and protection from excessive starts» For the machine provides both overload and underload protection and guards against stalled impellers, rotation direction and excessive acceleration time Take advantage of easy communication and programming features The integrated keypad display provides access to configuration menus enabling real-time visual feedback The simply start menu allows you to set up basic parameters to get you up and running quickly The multi-function integrated Modbus port allows connection to either:» A remote-mount keypad for access outside of the enclosure» Connection to a Modbus network for remote communication» SoMove PC software for configuration and diagnostics 4

Integrated functions to optimize your machines Centrifugal pumps Soft slowdown and stopping reduces water hammer Protection against underloads and reversed rotation Piston pumps Monitors pump priming and direction of rotation Voltage boost on start-up Fans Underload parameter for broken belt detection Brakes torque on stopping Turbine blowers Thermal monitoring of the motor with an electrically-isolated PTC probe Refrigerant compressors Monitors starting characteristics Manages number and time lapse of starts Screw compressor and centrifugal compressor Protection against reversed rotation Contact for automatic draining on stopping Conveyors Overcurrent threshold and time delay parameter for load monitoring Second set of motor parameters based on the load carried Screw conveyors Input to monitor external state or condition Agitators, mixers Displays the current indicating the density of the material Automatic cooling fan control The Enclosed Altistart 22 can even replace traditional low HP starters in commercial/industrial applications. 5

Selection guide The Enclosed Altistart 22 catalog number, located on the nameplate on the inside of the door, is coded to describe the configuration, power ratings and selected options. Use the following table to translate the catalog number into a description of the Enclosed Altistart 22 combination motor controller. Table 1: Catalog Number Example: 863922UCG4BA06A07 Field 1 2 3 4 5 6 7 8639 22U C G 4 B A06 A07 Controller Class PowerPact Thermal- Magnetic Circuit Breaker 7.5 hp Type 1 General Purpose 460 Vac Basic Shunt Trip Start-Stop Push Button Run Light (Red), Off Light (Green) Table 2: Catalog Number Description 6 Field Digit Characteristic Description Controller Class 8639 = Circuit Breaker Disconnect 8638 = Fusible Disconnect 01 1 3 Controller Style 22T = Altistart 22 with PowerPact Motor Circuit Protector 22U = Altistart 22 with PowerPact Thermal-magnetic Circuit Breaker 22F = Altistart 22 with Molded Case Switch and Class J Fuse Block Type 1 and Type 12: Type 3R or 50 C Rated: 02 4 Horsepower Ratings 03 5 Enclosure Type 04 6 Voltage 05 7 Power Circuit 06 8 10 Control Options 07 11 13 Pilot Device Options 08 14 16 Miscellaneous Options Available 3 50 hp @ 208 V 5 60 hp @ 230 V 10 125 hp @ 460 V 15 150 hp @ 575 V G = UL Type 1: General Purpose A = UL Type 12: Industrial Use H = UL Type 3R: Outdoor Use 2 = 208 Vac 3 = 230 Vac Basic Shunt Trip Full-featured Shunt Trip Non-reversing Isolation 3 40 hp @ 208 V 5 50 hp @ 230 V 10 100 hp @ 460 V 15 125 hp @ 575 V 4 = 460 Vac 5 = 575 Vac Reversing Isolation Integral Full-voltage Bypass A06 = Start-Stop Push Buttons B06 = Forward-off-reverse C06 = Hand-Off-Auto (HOA) Selector Switch D06 = Stop-Run Selector Switch E06 = Hand-Auto Selector Switch/Start-Stop Push Buttons A07 = Run Light (Red), Off Light (Green) B07 = Push-to-Test Run Light (Red), Push-to-Test Off Light (Green) C07 = Run Light (Red), Off Light (Green), Trip Light (Yellow) D07 = Push-to-Test Run Light (Red), Push-to-Test Off Light (Green), Trip Light (Yellow) with Trip Reset Function Contact your local Schneider Electric sales representative or distributor for more options.

Specifications Electrical Specifications Supply Voltage 208 Vac +10%/-15%; 230 Vac +10%/-15%; 460 Vac +10%/-15%; 575 Vac +10%/-15% Control Voltage Frequency 50/60 Hz ± 5% 115 Vac +10%/-15% (control power transformer included) Rated Current Full load current (FLA) per NFPA 70/NEC 2009 Type 1 and Type 12: Type 3R or 50 C Rated: Motor Power Motor Voltage Starting Duty (Standard Duty) 1 In is the controller full load current listed on the nameplate. 3 50 hp @ 208 V 5 60 hp @ 230 V 10 125 hp @ 460 V 15 150 hp @ 575 V 208 V, 230 V, 460 V and 575 V S1: Starting at 350% of In 1 for 40 s from a cold state 3 40 hp @ 208 V 5 50 hp @ 230 V 10 100 hp @ 460 V 15 125 hp @ 575 V S3: Starting at 300% of In 1 for 20 s, or 200% of In for 40 s, with a load factor of 95% and 3 starts per hour Environmental Specifications Storage Temperature -13 F to +158 F (-25 C to +70 C) Operating Temperature Type 1 and 12: +14 F to 104 F (-10 C to 40 C) Type 3R and Mod X10: +14 F to 122 F (-10 C to 50 C) Humidity 95% with no condensation or dripping water, conforming to IEC 60068-2-3 Altitude 1000 m (3280 ft.), derated by 2.2% for each additional 100 m (328 ft.) up to 2000 m (6560 ft.) maximum Enclosure Pollution Degree Resistance to Vibration (Soft Starter Only) UL Type 1: General Purpose UL Type 12: Industrial Use, Dust-tight and Drip-tight UL Type 3R: Outdoor Use Pollution degree 2 (UL Type 1 and UL Type 3R) and pollution degree 3 (UL Type 12) per NEMA ICS-1 and IEC 60664-1 According to IEC 60068-2-6: 1.5 mm peak to peak from 3 Hz to 13 Hz 1 gn from 13 Hz to 150 Hz Resistance to Shocks According to IEC 60068-2 UL listed per UL 508 under category NKJH. Conforms to applicable NEMA ICS, NFPA and IEC standards. Manufactured under ISO 9001 standards. Codes and Standards Factory modification E10 provides Canadian cul certification per C22.2 No.14. Complies with requirements of the American Recovery and Reinvestment Act (ARRA) of 2009 (Pub.L. 111-5). Equipment will be assembled in the U.S. 7

Features Soft Start Control Fuse User Terminal Block TB1 Circuit Breaker Control Power Transformer Control Fuses FU6, FU7, FU8 Altistart 22 Soft Start Space for Field-mounted Control Option Service Entrance Lug (Z10) Ground Bar For more information about the Enclosed Altistart 22 soft start/soft stop motor controller, visit www.schneider-electric.us/go/drives or contact your local sales representative or Schneider Electric distributor. Schneider Electric USA, Inc. Automation and Control Center of Excellence 8001 Knightdale Blvd. Knightdale, NC 27545 Tel: 919-266-3671 www.schneider-electric.us/go/drives Schneider Electric Canada, Inc. 19 Waterman Avenue Toronto, ON M4B 1Y2 Tel: 1-800-565-6699 This document has been printed on recycled paper 2011 Schneider Electric. All Rights Reserved. Document Number 8800BR1101 February 2011 tk