Operating Instructions Dual Pressure Switch BPS3000

Similar documents
Operating Instructions Dual Pressure Switch BPS3000

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions

Switch to. Generation NEW Electronic Level. One Series for. Pressure Temperature Level

Fluid Power Fluid Power

XMLRppp Electronic pressure switch

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Temperature switch. Switching output 2 transistors PNP Logger Ring buffer: 3518 data points Sampling time: s, Off (0)

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

Operating instructions Flow monitor SI / / 2014

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Important instructions

Electronic Pressure Switch EDS 3000

Model Pressure range ON/OFF output Linear output

Operating instructions

Operating Instructions for Torsion Paddle Flow Meter / Monitor. Model: DPT-...

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

zelsius Installation and operating manual All that counts EnergyMetering

Wind Power Inverter WINDY BOY 5000A/6000A

SPG-DIGI. Operating Instruction. Please read carefully before use!

KRIWAN Oil level regulators. Operating Instructions Accessories and Application Information

Operating instructions Electronic level sensor LK7 / LK /07 04/2006

u Electronic Products u Pressure Transducers u Mechanical Pressure Products u Valves & Regulators u Temperature Products u Level Products u Air

Model Pressure range ON/OFF output Linear output

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Product overview. Product overview. Control. Control. every move. Pressure Temperature Level Flow

Assembly and Maintenance Manual Type ASNU

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Assembly and Maintenance Manual Type AS

English. Instruction and operation manual S 212. Dew point sensor

Declaration of Conformity as per Directive 97/23/EC

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Operating Instructions K Always on the safe side.

Documentation. RM-BV4 Micro DP. Filter control

Instruction Manual. Ex-Time 40 / 50

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Signet Pressure Transmitter

Operating Instructions

Pressure sensors - Nautilus

SensoLyt 700 SensoLyt 700 SW

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

User manual. Abyzz Control System

Operating manual UPS - System

Operating Instructions

Sensor technologies Pressure sensors Series PE5. Brochure

zelsius Installation and operating manual All that counts. EnergyMetering

Operating instructions Flow monitors SI5002 SI5003 SI / / 2012

Operating Instructions for Paddle Flowswitch Model: PPS-...

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Assembly and Maintenance Manual Type RSBW

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Vacuum generator OVEM. Operating instructions f [ ]

Operating Instructions

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

OPTISWITCH 6500 C Technical Datasheet

DPS280 / DVS280 Series

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Operating instructions K- Control 4960, 4965, Always on the safe side.

Operating Instructions MP 6. perma-tec GmbH & Co. KG perma MP 6 perma-tec GmbH & Co. KG perma MP 6

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

Operating Instructions CYR52

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

ECONOMISER SERIES E2T USER MANUAL

Contamination switch VS

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

EPS/ELA-Series User Manual EPS/ELA 250W

PRX-5A-HV. Operating manual. Stabilised receiver power supply. PRX-5A-HV Power for Receiver - High Voltage. Order No. 4176

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Exchange of rollers from the XTS-Mover

Operating manual. Custom made gearboxes

Operating Instructions

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

ST Wiring diagram. Product description. Temperature controller. Order number

Signet Pressure Transmitter

Operating instructions Flow monitors SI5000 SI / / 2007

Motorized roller MRA50

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Transcription:

Approx 25.4 (1.00) 32 (1.26) M12x1 85.8 (3.38) 39.8 (1.57) 51 (2.00) 10 Technical Data Measuring element Measuring ranges Display Transistor switching s PNP BPS3000 Ceramic sensor optional: piezoresistive sensor at 600 bar (9000 psi): piezoresistive sensor only 0... 0.2 bar to 0... 600 bar, 0... 3 psi to 0... 9000 psi, gauge pressure 0 1 bar to 0 10 bar, 0 15 psi to 0 150 psi, absolute 4-digit 14-segment LED display, red, digit height 9 mm 1 or 2 x NONC function (programmable), adjustable switching time delay 0... 50 s Operating Instructions Dual Pressure Switch BPS3000 Operating temperature range -10... +70 C +14... +158 F Media temperature range -25... +100 C -13... +212 F Storage temperature range -30 +80 C -22 + 176 F Process connection G ¼" M, G ½" front-flush, 14" NPT, 12" NPT, 716 20 UNF JIC 37, 716 SAE-4 Protection systemclass IP65IP67III NEMA 6 Electrical connection Auxiliary power Plug 45-pin, M 12x1 15... 32 V DC For further technical data and options please refer to the data sheets Operating and display elementsdimensions Dimensions (example) in mm (inch) 1 Intended Applications...2 2 Safety Instructions...2 3 Standards...3 4 WarrantyGuarantee...3 5 Installation...3 6 CommissioningOperation...5 7 Programming...5 7.1 Parameters...6 7.2 Menu Structure...8 8 MaintenanceCleaning...11 9 Decommissioning...11 10 Technical Data... 12 Art. no.: 923-1966 1 2 Item 1: LEDs AL (red) Alarm S1 (red) switching point 1 S2 (red) switching point 2 Item 2: Keys For functions refer to chapter 7 "Programming" on page 5. Index C, 24.15.2014 Software version: 1.2 or higher Specifications are subject to changes without notice! Barksdale Inc. 3211 Fruitland Avenue Los Angeles, CA 90058-0843 U.S.A. Phone: (323) 589-6181 Fax: (323) 589-3463 e-mail: sales@barksdale.com www.barksdale.com Barksdale GmbH Dorn-Assenheimer Straße 27 D-61203 Reichelsheim Phone: +49 (6035) 949-0 Fax: +49 (6035) 949-111 and 949-113 e-mail: info@barksdale.de www.barksdale.de 12 1

1 Intended Applications The dual pressure switch monitors system pressures and has up to two switching s and one analog. The switch may only be used in the specified fields of application. The temperature ranges must be within the permissible limits. Do not exceed rated pressure and electrical load values. Observe also the applicable national and local safety instructions for assembly, commissioning and operation of the switch. The switch is not designed to be used as the only safety device in pressurized systems according to Pressure Equipment Directive 9723EC (PED). 2 Safety Instructions The safety instructions are intended to protect the user from dangerous situations andor prevent material damage. In the operating instructions the seriousness of the potential risk is designated by the following signal words: Refers to imminent danger to users. Nonobservance may result in fatal injuries. Refers to a recognizable danger. Nonobservance may result in fatal injuries, and destroy the equipment or plant parts. Refers to a danger. Nonobservance may result in light injuries and material damage to the switch andor to the plant. IMPORTANT Refers to important information essential to the user. 3 Standards The standards applied during development, manufacture and configuration are listed in the CE conformity and manufacturer's declaration. 4 WarrantyGuarantee Our scope of delivery and services is governed by the legal warranties and warranty periods. Terms of guarantee We guaranty for function and material of the dual pressure switch under normal operating and maintenance conditions in accordance with the statutory provisions. Loss of guaranty The agreed guaranty period will expire in case of: incorrect use, incorrect installation or incorrect handling or operation contrary to the provisions of these operating instructions. No liability is assumed for any damage resulting therefrom, or any consequential damage. See also Barksdale Standard Terms and Conditions 5 Installation Jolts and heavy vibrations must be avoided during transport. Even if the switch casing remains undamaged, inside parts may be damaged and cause malfunctions. The pressure switch may only be installed and electrically connected by instructed staff. The switch may only be installed in systems where the maximum pressure P max is not exceeded (see type label). Only install the switch when deenergized (electrically and hydraulicallypneumatically). Mount the pressure switch from the bottom to the fitting using a wrench SW 27 and tighten it to a torque of 45 Nm. Disposal The switch must be disposed of correctly in accordance with the national or local regulations for electricelectronic equipment. The switch must not be disposed of with the household garbage! 2 3

Figure 3: 2 switching contacts and 1 analog Figure 1: 2 switching contacts Figure 2: 1 switching contact and 1 analog Electrical connection is to be carried out dependent on the type of switch (see name label) according to the chart below. Improper connections may cause malfunctions or incorrect switch s and damage to the unit. Plug M 12x1 45-pin Pin 1 brown Pin 2 white Model with 1 switching contact Model with 2 switching contacts Model with 1 switching contact and 1 analog Model with 2 switching contacts and 1 analog +Ub (15... 32 V DC) +Ub (15... 32 V DC) +Ub (15... 32 V DC) +Ub (15... 32 V DC) - SP2 (0.5 A max.) analog: 4... 20 ma or 0... 10 V analog: 4... 20 ma or 0... 10 V 6 CommissioningOperation The pressure switch may only be commissioned and operated by authorized staff. Do not put the switch into operation when the switch itself or the connection cable is damaged. Be aware of the fact that in case of operation with higher temperatures the casing surface may become very hot! Pin 3 blue Pin 4 black Pin 5 gray 0 V 0 V 0 V 0 V SP1 (0.5 A max.) SP1 (0.5 A max.) SP1 (0.5 A max.) SP1 (0.5 A max.) - - - SP2 (0.5 A max.) After having been switched on the switch runs through a self-test. If the software recognizes an error during the self-test or during operation, this is signalled in the display by "Err" and the corresponding message, refer to Error list on page 7. The red LEDs S1 and S2 signal the activity of the two switching points. Operation is menu-driven via three keys:, and Do not use any pointed, hard objects for making entries. The keys may be damaged by pointed, hard objects. For information about the factory settings for the parameters and how to change them please refer to the next chapter 7 "Programming". 7 Programming Navigation function Symbol (keys) Menu descending Menu ascending Horizontal movement in menu, select menu item Parameter change ascending Parameter change descending Adopt parameter change and return to current menu item Return to measured value display Press + simultaneously 4 5

7.1 Parameters Parameter 14-segment display Description SP1SP2* FH1FH2* rp1rp2* FL1FL2* EF res ds1ds2* Hysteresis function: Switching point of solid state contact Window function: Window High solid state contact Hysteresis function: Hysteresis of solid state contact Window function: Window Low solid state contact Extended programming functions Reset parameters to factory settings Switching time delay the set contact rating must be permanently exceeded to trigger a switching function Parameter 14-segment display Description AEP** dpa** ErS.A** Hi Lo COF ddis Analog end value Damping of analog Error signal of analog Values: < 3.6 or > 22 or Off Saved value of highest pressure measured Saved value of lowest pressure measured Offset correction (max. 10 % of measuring range) Damping display Fdis Rotate display through 180 dr1dr2* Ou1Ou2* Switching time delay the contact rating must be permanently lower than the set contact rating to trigger a switching function Switching function of solid state contact HNO HNC FNO = Hysteresis function, NO contact = Hysteresis function, NC contact = Window function, NO contact udis Firm LocK * only models with 2nd switching contact ** only models with analog Unit indication Firmware version Locking feature uni OuA** FNC DIA = Window function, NC contact = Diagnostic function, NO contact (only Ou2) Select unit: bar, PSI, MPa If the measuring range is outside the display range, unit selection is impossible. The parameter "uni" is not displayed. Analog I = 4... 20 ma Error list Parameter 14-segment display Description sens Sensor defect SC1 Short circuit, solid state contact 1 SC2 Short circuit, solid state contact 2 AOut Open, short circuit U = 0... 10 V OL Sensor limit positive ASP** I.INV = 20... 4 ma U.INV = 10... V Analog start value UL KEY Sensor limit negative Internal defect 6 7

7.2 Menu Structure Factory setting 1 2 3 Factory setting Display Unit dr2* Hysteresis delay, 2 SP1 FH1 Switching point 1 0... x bar *** Ou1 Output 1 Off - Hno - Hnc - Fno - Fnc Hno rp1 FL1 Hysteresis 1 0... x bar *** Ou2 Output 2 Off - Hno - Hnc - Fno - Fnc - dia Hno SP2 FH2* Switching point 2 0... x bar *** uni Unit selection bar - PSI - MPa bar rp2 FL2* Hysteresis 2 0... x bar *** OuA** Analog Off - I - U - I.INV - U.INV I EF res Basic factory setting no - yes ASP** Analog start P min... x bar *** ds1 Switch-on delay, 1 AEP** Analog end x bar... P max *** dr1 Hysteresis delay, 1 dpa** Damping, analog ds2* Switch-on delay, 2 ErS.A** Error, analog signal Off - > 22 - < 3.6 Off 1 2 3 4 5 6 8 9

4 5 6 Factory setting 8 MaintenanceCleaning Maintenance Hi Maximum peak value Delete The pressure switch requires no maintenance. Check the switch for functioning at regular intervals. Lo Minimum peak value Delete If the switch does not work properly, stop operation immediately. Cleaning COF Offset (10 % of measuring range) The keys may be damaged by the use of unsuitable cleaning agents. Do not use any cleaning agents containing solvents or abrasive additives. ddis Damping display 9 Decommissioning Fdis Function display norm. rot. norm. Only remove the switch when deenergized (electrically and hydraulicallypneumatically). udis Unit indication ON - OFF OFF Disconnection of the switch from pressure and power supply must be carried out by trained or instructed personnel according to state-of-the-art standards. Firm Firmware version Be aware of the fact that in case of operation with higher temperatures the casing surface may become very hot! * only models with 2nd switching contact ** only models with analog *** setting according to measuring range Lock Display + 5 sec. Lock Software lock On - Off Off 10 11