Safer and Easier with Conductive Piping. Making Fuel Flow Safely.

Similar documents
Static Discharge Ignition of Combustible Atmospheres

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Forecourt safety Competent persons

by Jim Phillips, P. E.

Control of Static Electricity during the Fuel Tanker Delivery Process

Static Discharge Ignition of Combustible Atmospheres. White Paper. Author Details: ungrounded vacuum tankers and road tankers.

Todd Evacuation Caddy

Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

Installation. Introduction

Sources of Ignition and Hazardous Area Classification Core

Electrical Safety Part I

Cen. -Stat Static Grounding clamps, cables and reels. Leading the way in hazardous area static control

Static Electricity Hazards and Controls. Dirk Smith, President Ionix Gas Technologies

Todd Gas Caddy Assembly Instructions

QUASAR ELECTRONICS KIT No ELECTRONIC CAR IGNITION

Earth-Rite MGV Mobile Grounding Verification. White Paper. Author Details: Page 1 of 5

Motional EMF. F = qvb

Static Discharge Ignition of Combustible Atmospheres. White Paper. Author Details:

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

IA HYSAFE & JRC IET WORKSHOP Research Priorities and Knowledge Gaps in Hydrogen Safety. Hydrogen Ignition and Light up Probabilities.

Page 1 of 4 Model: BTL4E-004 V2.0 Pulsar Electronic LED Turn Signal Flasher Unit Installation & Operation Instructions:

IMPORTANT INFORMATION

Assembly instructions

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

WHAT YOU DON T KNOW COULD BURN YOU! How To Avoid The Unknown Dangers Of Handling Fuel In Your Shop

OPERATING INSTRUCTIONS

Explosion Characteristics Measurement of Combustible Dusts

INSTALLATION GUIDE FUELTEC- FUEL POLISHING SYSTEM

IMPORTANT INFORMATION

HIGH VOLTAGE vs. LOW VOLTAGE: POTENTIAL IN MILITARY SYSTEMS

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

P O B o x S t. L o u i s, M O P h o n e : ( ) ~ E m a i l : w m h u I t a o l.

S150,S300 Series Pure Sine Wave Inverter User s Manual

Pro 30 Plus Gas Caddy

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

INFORMATION FOR FIRE SERVICES ON LPG / AUTOGAS VEHICLES

Friction. Coefficients of friction for rubber on roads are listed in the table. asphalt road) Dry road Wet road 0.53

VAN DE GRAAFF GENERATORS - 400kV

CHAPTER 6.3: CURRENT ELECTRICITY

40 CFR 63, Subpart CCCCCC

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

General information about underground storage tank (UST) fueling systems in every day language.

KPS LPG Pipe System. Making fuel flow safely.

Inspecting Airport Fueling Systems

1410 Series & 4413 / 4423 Series Intrinsically Safe Solenoid Operated Directional Control Valves & Pilot Valves for Marine Applications

Wilkins Safety Group

CONSOLIDATED VERSION IEC TS Explosive atmospheres Part 32-1: Electrostatic hazards, guidance. colour inside. Edition 1.

Fuel Pump Module. Fuel Pump Module. Special Service tools. Remover/Installer, Fuel Pump Module/Fuel Transfer Pump Locking Ring A 1.

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

SINE WAVE INVERTER OWNER'S MANUAL

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

An Analysis of Alternative Fuels for Automotive Engines. Joey Dille

Advice Pertaining to ERC Resolution No.16 and the Role of Hybrid Generation Advice with respect to specific questions from PIPPA

ENVOY FUELING NEWSLETTER #10. Maintenance Safety and Compliance. PUBLISHED July 20, Office Fax

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

Transmission & Distribution Glossary of Electrical Terms

Flameproof Alternator

Type 2000 Transducer Product Instructions

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

Introduction & Owner Information 1 Safety Precautions 2 Parts 2 Installation Instructions 2 Tools 2 Warranty Information 6

INSTRUCTIONS. #82028 Diesel Nitrous System. Thank you for choosing ZEX products; we are proud to be your manufacturer of choice.

Awell-run paint shop applying solvent-based

EARTHING YOUR QUESTIONS ANSWERED

Electrical Systems. Introduction

CONTROLS UPGRADE CASE STUDY FOR A COAL-FIRED BOILER

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

Generator Termination Bus-bar Arrangement - Design requirements: Utility Perspective

THE FOURTH STATE. Gaining a universal insight into the diagnosis of automotive ignition systems. By: Bernie Thompson

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

FLEX-ING TM DISPENSER HOSES INSTALLATION GUIDE

CONDUCTION AND INDUCTION. Lesson 3

Purpose This document provides installation instructions for Gasboy 9800A/2600A Pump Interface Kits.

Section 10: Engraving Machine Cleaning

Electrostatic Fieldmeter

Electricity MR. BANKS 8 TH GRADE SCIENCE

Appendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 8/24/2018

Standard Workshop Practices 01-03

RP Instruction Manual

Installation Instructions for Aux 101 Kit A044Z055

Requirements for Dispensing of Compressed Natural Gas. Yvonne Espinoza, PE Austin Fire Department Engineering Services

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

QMOT Motor QSH4218 Manual 42mm QMOT motor family

Introduction: Electromagnetism:

Motor Starter Reverse MSR22-FBP

Triple Output Power Supply

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

EY, EYD, & ENY Series

ANSI Z50.1. Safety Standards

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Ignition energy enough for igniting the mixture is available, such as sparkles generated by friction and impaction, electric arc or hot surfaces.

PowerCORE 8.8mm Hybrid Super Conducting Wire CORETECH OVERVIEW

ANTI-SYPHON VALVE INSTALLATION GUIDE

Purpose This document provides installation instructions for the Gasboy 9820 Pump Interface Kit.

CHARGING SYSTEM 7.7 GENERAL TROUBLESHOOTING. Alternator. Voltage Regulator. Battery. Wiring. Voltage Regulator Inspection HOME

Transcription:

Safer and Easier with Conductive Piping Making Fuel Flow Safely www.opwglobal.com

Fire Prevention Fire at the filling station is something that needs to be prevented. The risk of a flammable atmosphere occurring is always present where fuel is handled. Just as smoking or open flames are not allowed in the station area, any other possible ignition sources must be eliminated. This includes discharges from static electricity on objects or people. 2

Fires with Non-Conductive Piping Fill Fires with Non-Conductive Piping Fill fires occur during or after filling of the underground tanks. In severe cases a full scale fire develops when fuel vapors are ignited by a static discharge. Sometimes the fire will be restricted and stop once there are no more vapors or oxygen to sustain it. Fill fires are sometimes preceded by audible cracking or tapping noises from discharges in or around the fill pipes. Fill fires have the potential of scaring away customers or lead to temporary close-down during investigation, implementation of new safety measures or reconstruction. Truck drivers may refuse to fill tanks at stations where incidents have occurred or where there is indication of static problems. There have been hundreds of known fill fires, some of which have been thoroughly documented and investigated. Chamber Fires with Non-Conductive Piping Fires in chambers are less common than fill fires, but may occur during inspection, repair or maintenance in tank chambers that contain spill and fuel vapors. Charged objects inside the chamber may discharge to the person entering the chamber or to tools he brings with him, igniting the flammable atmosphere. Any fire in a confined space can have severe consequences and obviously needs to be avoided. Risk factors Factors that add to the risk of static fires are: Use of non-conductive piping (prerequisite) High speed fuel flow Low conductivity fuels Dry air Turbulence caused by elbows, reducers, filters and flame arresters Fuel quality and impurities in the fuel www.opwglobal.com 3

Charging of Non-conductive Pipes Static electricity is generated when a low conductivity fuel flows in a non-conductive pipe. The fuel will be positively-charged and the pipe wall negatively-charged. Since the charges of the pipe wall cannot go anywhere, static electricity will accumulate as long as fuel flow continues. Possible Discharges Between areas on the pipe wall with different charges. Between negatively charged pipe and positively charged fuel. Between negatively charged pipe and grounded conductor. Precautions for Avoiding Static Risks with Non-conductive Pipes If you decide to use non-conductive piping despite the risks, you need to take the precautions listed in the IEC standard TR 60079-32. Avoid unburied piping Always backfill on top of pipes before starting any fuel flow Keep pipe lengths inside chambers and fill boxes as short at possible Limit speed of fuel flow Charging increases with flow velocity Keep fuel flow below 2,8 m/s Avoid turbulence Turbulence increase charging Do not use flame arresters or fine filters unless after very careful consideration 4

Charging by Induction from Non-conductive Pipes The static charges in the pipe create an electrostatic field and conductive objects in the field will get an induced charge. The induced charges can discharge either between two unbonded conductors in the system or to a tool or a person in the proximity. Discharge between two unbonded conductive objects. Discharge to a hand tool or person. Put safety valves on fill pipes Mount safety valves on all non-conductive fill pipes Interlocked systems that prevent any air from entering the fill pipe are preferred Bonding and grounding Bond and ground all isolated conductive objects in chambers and fill boxes Insulation If bonding is not practical, insulate completely to prevent sparks Plug welding socket pins with plastic caps made of a material that provides long-lasting insulation against discharges Inspect and check earthing Earthing arrangements need to be inspected and tested periodically 1 time/year Also inspect and test earthing after all work in chambers or at fill points Earthing connections may corrode Earthing wires may become snagged and damaged or come loose www.opwglobal.com 5

Conductive Pipes Eliminate Static Risks Use of conductive plastic pipes eliminates the risks from static electricity. Very little static electricity is generated in a conductive pipe and the charges are immediately dissipated to earth. There is no accumulation of charges and zero risk of induction and static discharges. Easy Installation Installation of KPS conductive pipes is very easy. Conductive connectors are placed in every joint to make conductivity continuous from end to end. No Special Earthing Arrangements or Precautions The conductive pipe is inherently earthed once connected to the end points. No bonding and grounding of conductive objects in chambers or fill boxes is needed. You save lots of work both during installation and after every instance of maintenance, upgrade or repair. No Periodical Testing There is no need for periodical testing of pipe conductivity or control of earthing arrangements. The conductive properties of the pipe will remain for the 30 year warranted life time of the pipe. Smoother Operation with Unrivaled Safety Margin Conductive piping has an unrivaled safety margin for static fires. KPS conductive pipes cannot get charged to more than approximately 40mV (0.040 V) which gives a safety margin of at least 25,000 times the voltage. This is why there have been zero (0) static fires or incidents where conductive pipes are installed. You do not need to worry about taking precautions like restricting fuel flow or using special fill safety valves, things that would slow down both dispensing and filling of tanks. 6

Conductive Pipes Eliminate Static Risks Future-Proof & Biofuel-Proof KPS conductive pipes are safe for use with all existing and conceivable future fuels, including biofuels that could be highly charging. Existing Non-Conductive Installations How should you deal with existing non-conductive installations? The KPS recommendation is simple: Unless any problems arise, just leave your existing installations as they are. If problems occur later on, you can then either adopt the precautions listed in IEC TR60079-32 or replace the non-conductive pipes with conductive ones. Conductive pipes can be used for upgrades and repair that need to be done, for example: Replacing a pipe line Repairing part of a pipe line Adding a dispenser island When you replace non-conductive piping on a station with conductive piping you increase the electrostatic safety, even if only a part of the piping system is conductive. www.opwglobal.com 7

Summary & Comparison Non-conductive pipe Conductive pipe Highest voltage ~27,000 V (not worst case) ~40 mv (0.040 V) Safety margin Fuel Fires & incidents Future-proof At best small (2-5 times), occasionally non-existing New fuels may not be safe in existing installations Hundreds of known fires and incidents May not be safe with future fuels At least ~25,000 times Safe for all conceivable fuels No (0) incidents Safe for all existing and conceivable fuels, including biofuels ATEX 137 compliance No Yes 8