Emergency Smoke Control Centrifugal Roof Exhaust Fans

Similar documents
READ AND SAVE THESE INSTRUCTIONS

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

Installation, Operation and Maintenance Manual

Model CUBE Belt Drive. Model CUE Direct Drive

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

Installation, Operation and Maintenance Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

Installation, Operation and Maintenance Manual

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

for Untempered - Make-Up Air Units

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK

Table of Contents. Document Centrifugal Utility Fans. Model SWB - Series 100, 200 and 300 Models SFB, SFD, SWB and SWD. Model SWB Series 200

Tubular Centrifugal Inline Fans TCN

. Downblast Centrifugal RoofExhaust Fans

Operation and Maintenance Manual. Series BI Centrifugal Blowers

MODEL CLS Centrifugal Filtered Supply Fans

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

READ AND SAVE THESE INSTRUCTIONS. Installation Operation and Maintenance Manual

Propeller Hooded Roof Fans

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

Direct Gas-Fired Heating

Installation. Centrifugal Roof and Wall Exhausters

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel

ASP/KSP Centrifugal Filtered Supply Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ECONOMIZER FAN. Receiving and Inspection

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators

SRSH Tamper Proof Centrifugal Exhauster INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

AC/VCR Centrifugal Roof and Wall Exhausters INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DUCT BLOWER Cabinet Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

FCE/FCRU Fiberglass Roof Exhausters INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Centrifugal Belt-Drive Upblast Exhaust Ventilators. Operating Instructions & Parts Manual

Installation, Operation and Maintenance Manual

LO-PRO. Receiving and Inspection. Handling Lift the fan by the base. NOTICE! Never lift by the shaft, motor or housing.

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Installation, Operation and Maintenance Manual

CCP Centrifugal Plug Fans

IMPORTANT! READ BEFORE PROCEEDING! US General Purpose Centrifugal Fan

Industry best 5 year fan housing warranty, 1 year motor warranty

REBEL/AQ/SEP/ETE/ETS IO&M

Centrex Inliner Direct & Belt Drive

SQN Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Tube Axial Inline Fans

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

WELDING FUME EXHAUSTERS & ARMS

CFS Centrifugal Filtered Supply Fans

User s Manual D-Series Blowers and Exhausters

Gravity Ventilators. Models FGI and FGR. Fabra Hood Intake and Relief

DESIGN GUIDELINES FANS PAGE 1 of 7

Installation, Operation and Maintenance Manual

D-Series Blowers and Exhausters

Centrifugal Direct-Drive Upblast Exhaust Ventilators. Operating Instructions & Parts Manual

CPL Centrifugal Plenum Fans

Centrifugal Direct-Drive Upblast Exhaust Ventilators. Operating Instructions & Parts Manual

Installation. Check, Test & Start Procedure

Duct Blower Cabinet Fans

Installation, Operation and Maintenance Manual

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

TMX Mixed Flow Inline INSTALLATION, OPERATION AND MAINTENANCE MANUAL

IM-210 INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS HOODED ROOF VENTILATORS UPBLAST ROOF VENTILATORS AIR PRESSURE AND SUCTION A WORD ABOUT SAFETY

Installation, Operation and Maintenance Manual

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

BCRFS Belt Driven Centrifugal Filtered Supply Fans

Installation, Operation and Maintenance Manual

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

Tubular Centrifugal Fans

MAINTENANCE - LPX PORTABLE TREATER

ROUND CENTREX Centrifugal Inline Fans

Installation, Operation and Maintenance Manual

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

HA/HAB Fiberglass Wall Mount Ventilators

Backward Inclined Hinged Restaurant Exhaust Fan

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

Models TXB & TXB-W Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Models TXB,TXB-W, TXB-RHUL Installation, Operation, and Maintenance Manual

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

Models TXB,TXB-W, TXB-RHUL Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual

Transcription:

IN THIS SECTION Emergency Smoke Control Centrifugal Roof Exhaust Fans HA~~ISAI~ SYSTEl\t1S, INC. Heat:ing &.-Air Condit:ioning Inst:allat:ion &,-Service

-------- READ AND SAVE THESE INSTRUCTIONS [RGREENHECK Building Value in Air. PN 460524 Model S-CUBE Belt Drive Emergency Smoke Control Centrifugal Roof Exhaust Fan Installation, Operating and Maintenance Manual Receiving Unit: Upon receiving unit, check for any damage and report it immediately to the shipper. Also check to see that all accessory items are accounted for. Move fan to desired location and fasten securely through mounting holes in base. Shims may be necessary depending upon roofing material thickness. Access to Motor Compartment: Access to the motor compartment is accomplished by removing the screws designated "R" in Fig. 1. The cover can then be removed and placed on a flat surface in an area protected from strong winds. Electrical Connection: The motor's amperage and voltage rating must be checked for compatibility to the supply voltage prior to final electrical connection. Also, the motor itself cannot have Thermal Overload. For Emergency Smoke Removal S-CUBE applications, the electrical supply must enter the motor compartment through the breather tube. Disconnect must be mounted outside the fans motor compartment. Consult local code authorities for your specific requirements. Shown below is the UL Listed label that the fan will bear. Recommended Emergency Smoke Control Installation I l/ Recommended j h- I Roof Opening ~ NEMA3R Disconnect factory wired from motorto disconnect through the breather tube UquldTight Flexible Conduit \~ by Others '""',n" ",L..I ''''',,,,,""""" Use of any non-approved smoke control damper is NOT permitted. Listed Power Ventilator For Smoke Contol Systems 76Y9 -- IMPORTANT -- ELECTRICAL -- If fan motor is NQI thermally protected, remote overload protection must be installed having adequate rating as to voltage, frequency, horsepower, and full load current per phase. Where connected to a circuit protected by fuses, use time delay fuses. For supply connection, use wires rated for at least 90 0 C (194 0 F). INSTALLATION -- When connecting electrical power to this fan, do not restrict motor movement. Motor must have sufficient movement for possible future belt or wheel adjustment. 454975 Fig. 1 For belt drive units in Emergency Smoke Removal installations, the electrical supply must be kept out of the airstream. They may also require an isolated power supply so that if power is cut to the building in the event of a fire, the fan will continue to operate. Check the local and national electrical codes for emergency smoke removal fans.

Pre-Starting Checks Check all fasteners for tightness. The wheel should rotate freely and be aligned as shown in Fig. 2. Wheel position is preset and the unit is test run at the factory. Movement may occur during shipment, and realignment may be necessary. Centering can be accomplished by loosening the bolts holding the drive frame to the shock mounts and repositioning the drive frame. Wheel and inlet cone overlap can be adjusted by loosening the set screws in the wheel and moving the wheel to the desired position. OVERLAP DIMENSIONS MODEL G 141-161 1/4 in. 200-300 1/2 in. ROTATION All S-CUBE fans have CW wheel rotation when viewed from top of fan. Fig. 2 Fig. 3 Direction of wheel rotation is critical. Reversed rotation will result in poor air performance, motor overloading and possible bumout. Check wheel rotation (viewing from the shaft side) by momentarily energizing the unit. Rotation should be clockwise as shown in Fig. 3 and correspond to the rotation decal on the unit. -,.-, CORRECT WRONG WRONG WRONG,.-,,.-,. -.-.,...rr..,...il., ~ ~ 11111 11111 11111 11111 - ~ --' Fig. 4 If adjustments are made, it is very important to check the pulleys for proper alignment. Misaligned pulleys lead to excessive belt wear, vibration, noise and power loss. (See Fig. 4 ) For all S-CUBE units, belt tension can be adjusted by loosening four fasteners (marked UR") on the drive frame. The motor plate slides on the slotted adjusting arms and drive frame angles in the same manner (see Fig. 5). Belt tension should be adjusted to allow 1/64 inch of deflection per inch of belt span. For example, a 15 inch belt span should have 15/64 inch (or about 1/4 inch) of deflection with moderate thumb pressure at mid-point between pulleys. (See Fig. 6). Overtightening will cause excessive bearing wear and noise. Too little tension will cause slippage at startup and uneven wear. Deflection = Belt Span 64 NOTE: Identical fasteners on opposing side Fig. 5 Fig. 6 The adjustable motor pulley is factory set for the RPM specified. Speed can be increased by closing or decreased by opening the adjustable motor sheave. Two groove variable pitch pulleys must be adjusted an equal number of tums open or closed. Any increase in speed represents a substantial increase in the horsepower required by a unit. Motor amperage should always be checked to avoid serious damage to the motor when speed is varied. 2

-----~----- MAINTENANCE Belts tend to stretch after a period of time. They should be checked periodically for wear and tightness. When replacing belts, use the same type as supplied with the unit. Matched belts should always be used on units with multi-groove pulleys. For belt replacement, loosen the tensioning device far enough to allow removal of the belt by hand. Do not force belts on or off. This may cause cords to break, leading to premature belt failure. Once installed, adjust belts as shown in "Pre-Starting Checks." Bearings are the most critical moving part of the fan and should be inspected at periodic intervals. Locking collars and set screws, in addition to fasteners attaching the bearings to the bearing plate, must be checked for tightness. In a clean environment and temperatures above 32 F./below 200 F., fan shaft bearings with grease fittings should be lubricated semi-annually using a high quality lithium based grease. If unusual environmental conditions exist, temperatures below 32 F.labove 200 F., moisture or contaminants, more frequent lubrication is required. With the unit running, add grease very slowly with a manual grease gun until a slight bead of grease forms at the seal. Be careful not to unseat the seal by over lubricating or using excessive pressure. Motor maintenance is generally limited to cleaning and lubrication (where applicable). Cleaning should be limited to exterior surfaces only. Removing dust buildup on motor housing ensures proper motor cooling. Greasing of motors is only intended when fittings are provided. Many fractional motors are permanently lubricated and should not be lubricated further. Motors supplied with grease fittings should be greased in accordance with manufacturers' recommendations. Where motor temperatures do not exceed 104 F (40 C), the grease should be replaced after 2000 hours of running time as a general rule. Wheels require very little attention when moving clean air. Occasionally, oil and dust may accumulate causing imbalance. When this occurs, the wheel and housing should be cleaned to ensure smooth and safe operation. The unit should be made non-functional when cleaning the wheel or housing (fuses removed, disconnect locked off, etc.). All fasteners should be checked for tightness each time maintenance checks are performed prior to restarting unit. A proper maintenance program will help these units deliver years of dependable service. TROUBLESHOOTING PROBLEM CAUSE CORRECTIVE ACTION REDUCED AIRFLOW System resistance too high Check system: Proper operation of backdraft or control dampers, obstruction in ductwork, etc. Unit running backwards Correct as shown in Fig. 3. Excessive dirt buildup on wheels Improper wheel alignment Bad bearings Be/ts too tight or too loose Clean wheel. Center wheelan inlets. Replace. Refer to Fig. 6 and adjust tension. Wheel improperly aligned and Center wheelan inlets. See Fig. 2. rubbing EXCESSIVE NOISE OR Loose drive or motor pulleys Align and tighten. See "Pre-Starting VIBRATION Checks." Foreign objects in wheel or housing Unbalance of wheel caused by excessive dirt and grease buildup Remove objects, check for damage or unbalance. Remove buildup. NOTE: Before taking any corrective action, make certain unit is not capable ofoperation during repairs. 3

PARTS LIST BEARINGS MOTOR PULLEY HOOD DRIVE FRAME ASSEMBLY *VERTICAL SUPPORTS CONDUIT CHASE MOTOR 1----+--- HOOD BAND 1---- BREATHER ~~~rf~==:r.:=rr-=~====~~;;j TUBE SHOCK MOUNTS (4) *DRAIN TROUG *WINDBANDS *CURB CAP / VENTURI * For replacement, the windband, vertical supports, drain trough and curb cap/venturi come as one complete assembly. NOTE: Each fan bears a manufacturer's nameplate with model number and serial number embossed. This information will assist the local Greenheck representative and the factory in providing service and replacement parts.. '.. WARRANTY. Greenheck warrants this equipment.to be free from defects in material and workmanship for a period of one year 'from the date of purchase.. Any units or parts which prove to be defective during the warranty period will be replaced at our option when returned to our factory, transportation paid.. The motor is warranted by the motor manufacturer fora period of one year. Should the motor prove defective during this period, it should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any installation or removal costs. [BGREENHECK P.O. Box 410' Schofield, WI 54476-0410 greenheck.com Copyright 2001 Greenheck Fan Corp. 4 10M S-CUBE FS Rev. 1 February 2001