Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Similar documents
www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

SECTION PADMOUNT TRANSFORMER - OIL FILLED

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Standard Features and Accessories

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

HPS EnduraCoil. Cast Resin Transformer

SUBSTATION TYPE TRANSFORMER - MINERAL OIL FILLED THREE PHASE OISC 65 C RISE 60 HERTZ

C. System Design and Performance Requirements

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

Unit Substation Transformers 5 and 15 KV Class

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

Volt Instrument Transformers

H1 H2 H3 X0 X1 X2 X3

Prime Power Energie Systems Inc.

www. ElectricalPartManuals. com Westinghouse Type RSL Rectangular Coil Core Form Liquid Immersed Substation Transformers

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

Distribution Transformers

Kuhlman Electric Corporation Volt Instrument Transformers

NEW Solutions for Underground System Growth

Kuhlman Electric Corporation Volt Instrument Transformers

ABB Ltd. FACTORY IN HANOI

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Technical Specification For Outdoor Substation Harmonic Filter Banks

Three-Phase Pole Mounted Recloser

Single Phase Padmounted Transformers kva

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Distribution Transformers

Modifiable TITAN Horizontal Motors Accessories and Modifications

www. ElectricalPartManuals. com Westinghouse PLAZAPADTM Tamper-Resistant Transformers For Underground Power Distribution 750 Thru 2500 Kva

TGK Prefabricated Substation Technical Data

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Technical Specification for Pole Mounted Capacitor Rack

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Proudly Made In America

SPECIFICATION FOR THREE PHASE PAD-MOUNT DISTRIBUTION TRANSFORMERS

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Large Power Transformers

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Single-Phase Step Voltage Regulator

DISTRIBUTION TRANSFORMERS SPECIFICATION #

Distribution transformers Efficiency over life-cycle

Instructions (HI-110) Installation, Operation, and Maintenance of Secondary Network Transformers. Howard Industries Distribution Transformer Division

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

MEDIUM POWER TRANSFORMER

ABB Transformadores para aplicaciones solares y eolicas

Howard Industries. Single-Phase Step

Medium Voltage Metal-Enclosed Switches

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Features, Benefits and Functions

Product Specifications for Phase Over Phase GOABS(r)

Power IT Liquid Filled Single Phase Padmounted Transformers kva

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R

30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

SECTION MOTOR REQUIREMENTS for HVAC

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

AIR CORE REACTORS. Phoenix Electric Corporation

Medium Voltage Metal-Enclosed Switches

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Small wonder. Station service voltage transformers for small power requirements

www. ElectricalPartManuals. com r" n;;-==- Westinghouse Ventilated Dry Type Transpac Power Centers Page 1 Descriptive Bulletin

Substation Transformers

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

Design Standard. Purpose: Design Standard:

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

Publication No.: PSG

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Transformer Installation, Operation, and Maintenance Manual

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

SECTION MOTOR CONTROL

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Transcription:

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer This document contains sample specifications for Liquid-Filled Type Drive Transformers You may use this information in whole or in part to complete your requests for bids and/or quotes. Virginia Transformer Corp. The Commitment Company 220 Glade View Dr. Roanoke, VA 24012 USA 540-345-9892 540-342-7694 Visit us at www.vatransformer.com

Liquid-Filled Drive Transformers 1.0 General (Circle choice or indicate specific information as appropriate.) 1.1 This specification covers three-phase liquid-filled drive transformers for indoor/outdoor applications. 1.2 The transformer shall be designed to operate in Seismic Zone 1/2/3/4. 1.3 Ambient: 0 Deg C Min, 30 Deg C average over 24 hr, 40 Deg C Maximum. 1.4 The transformers will be designed, assembled and tested in accordance with the latest applicable ANSI, NEMA and IEEE standards. 1.5 The transformer will be manufactured by Virginia Transformer Corp.or manufacturer with 20 years experience in similar application. 2.0 Construction 2.1 Basic ordering data shall be as follows: 2.1.1 KVA rating OA, OA/FFA, OA/FA 2.1.2 Overload Duty Class 2.1.3 Temperature Rise Deg C. 2.1.4 Primary voltage volts delta/ wye 2.1.5 Primary BIL rating kv Recommended BIL, Temp. Rise Data: Voltage Class Recommended BIL Duty Long RMS Duty Allowed 1.2 KV 30 KV 2.5 KV 45 KV Class time rating Cycle Temp. Rise Deg C 5.0 kv 60 KV T1 100 % 1.00 65 8.7 KV 75 KV 15.0 KV 110 KV T2 1.00 65 25.0 KV 150 KV 34.5 KV 200 KV 46.0 KV 250 KV T3 T4 1.08 60 1.18 55

2.1.6 Primary terminal arrangement ANSI segment 1/2/3/4 Cover Mounted/ Sidewall Mounted with bottom/ top/ side entry and for Full Height/ Partial Height Air Terminal Chamber or Close coupled to primary switch or Busduct flange 2.1.7 Primary taps ± 2 x 2.5% full capacity 2.1.8 Impedance % (ANSI tolerances) on Full KVA/ ½ KVA Basis 2.1.9 Secondary voltage volts delta/wye ; delta & wye 2.1.10 Secondary BIL kv 2.1.11 Conductor Material copper / aluminum 2.1.12 Secondary terminal arrangement ANSI segment 1/2/3/4 Cover Mounted/ Sidewall Mounted with bottom/ top/ side entry and for Full Height/ Partial Height Air Terminal Chamber or Close coupled to low voltage panel or Busduct flange 2.1.13 Electrostatic Shield Yes / No 2.1.14 Application Steel Plant / Power Plant / Paper Plant / Cement Plant / Other Process Industry / Induction Furnace/ Traction 2.1.15 K-Factor 2.2 Windings will be aluminum/copper 2.3 The unit will be filled with one of the following fluids: mineral oil/silicone fluid*/rtemp fluid*/beta fluid*. (*High flash point liquid for indoor applications) 2.4 The transformer will be capable of continuous operation with average winding temperature rise not exceeding 55 C at 100 percent KVA or 65 C at 112 percent KVA loading with no decrease in normal transformer operating life. Temperature rise to be measured by resistance method. 2.5 The transformer will be capable of operation at rated KVA at 3300 feet altitude (1000 meters) without exceeding temperature limits, provided the maximum temperature of the cooling air not exceed 40 C and the average temperature of cooling air for any 24-hour period does not exceed 30 C. 2.5 If the KVA rating specified in article 2.1 above is OA/FFA, all current-carrying parts must be capable of handling the future current associated with the fan-rated KVA. If the KVA rating specified in article 2.1 above is OA/FA, the unit will be furnished with all necessary fans and equipment for automatic temperature-controlled forced-air cooling to obtain an additional capacity of 15 percent on units rated 750-2499 KVA, or an additional 25 percent capacity on units 2500 KVA and above. Fan motors will be rated 208-240 volt 60 hertz single-phase supply. (This supply to be furnished by the purchaser)

2.6 The transformer will be designed to carry short-time emergency overloads in accordance with ANSI C57.92 and NEMA TR 98 as applicable. Duration and magnitude of designed withstand capability will be as outlined in ANSI C57.12 and the latest IEEE short-circuit test code. 2.7 The transformer shall be designed to withstand mechanical axial and radial forces due to overloads. The transformer shall electrically designed to take care of the voltage and current harmonics adequately. 2.8 The transformer will be furnished with the following features and accessories: 2.8.1 Welded top cover with round manhole/hand hold in cover. Manhole/hand hold will be gasketed and clamp type. (Bolted flange type will not be accepted.) 2.8.2 Provisions for jacking, skidding and lifting along directions of transformer centerlines. 2.8.3 Diagrammatic nameplate per ANSI standards 2.8.4 Two ground pads copper faced/stainless steel on base. 2.8.5 Drain valve with sampler upper filter valve 2.8.6 Deenergized tap changer with external operating handle brought out through tank wall at height convenient to the transformer design with provisions for padlocking and with a visible indication of position. 2.8.7 Magnetic liquid level gauge with/without alarm contacts 2.8.8 Dial-type top liquid thermometer with/without alarm contacts 2.8.9 Pressure vacuum gauge with/without contact bleeder valve on pressure vacuum gauge (standard above 2500 KVA). 2.8.10 Pressure relief valve/device. If device, with/without contacts. (Pressure relief device standard on units 2500 KVA and above and on all units filled with silicone, RTemp or Beta fluid.) 2.8.11 Sudden pressure relay to operate external contacts. (Sudden pressure standard on units 2500 KVA and above) 2.8.12 KV Distribution Class/ Intermediate Class/ Station Class surge arrestors on HV. 2.8.13 Nos current transformers on HV with SR/ MR ratio / 5 amps. 2.8.14 Nos current transformers on HV with SR/ MR ratio / 5 amps 2.9 Unit will be designed for sealed tank/inert gas/conservator construction for preservation of the transformer oil and insulation.

2.10 The tank will be designed to withstand pressure 25 percent greater than the required operating design without permanent deformation. The operating pressure will be specified on the nameplate. Construction will consist of carbon steel plate reinforced with external side wall braces if required. All seams and joints will be welded. 2.11 The radiators will be fixed/removable with shut-off valves, constructed of minimum 18-gauge steel and pressure tested before installation on the tank. The complete tank assembly will be leak tested for eight hours minimum before shipment. 2.12 Transformer tank and radiators will be cleaned and primed followed by application of an intermediate coat of enamel/epoxy and final coat of enamel/epoxy ANSI color 61/70 for a total thickness of 3-5 mils before shipment. 3.0 Testing 3.1 The following tests will be performed on all units in accordance with the latest revision of ANSI test code C57.12.90 and/or NEMA TR1. 3.1.1 Resistance measurements of all windings on the rated voltage connection of each unit and at the tap extremes of at least one unit of a given rating. 3.1.2 Ratio test on the rated voltage connection and on all tap connections. 3.1.3 Polarity and phase-relation tests on the rated voltage connections. 3.1.4 No-load loss test at rated voltage on the rated voltage connection. 3.1.5 Exciting current test at rated voltage on the rated voltage connection. 3.1.6 Impedance and load loss tests at rated current on the rated voltage connection of each unit and on the tap extremes of at least one unit only of a given rating. 3.1.7 Applied and induced potential tests 3.1.9 Temperature test will be made on at least one unit unless results of an essentially duplicate design are available. 3.2 Results of the above tests including no load loss data will be submitted with final drawings.