4 Deep Well Submersible Pump Part # Power Flow M 3 /H 0 1 2 2.6 3.2 3.6 4.2 4.5 Weight HP Volt Amp Flow (GPM) 0 4.6 9.1 11.5 14 16 18.4 20 (lbs) MA0343X-4 1/2 115 6.5 Head (ft) 154 142 120 103 80 56 27 5 26 MA0343X-4A 1/2 230 3.3 Head (ft) 154 142 120 103 80 56 27 5 26 A B C D E MAX 28.5 13.7 14.8 1-1/4 3.86 4.0 4" deep well submersible pump, 150 feet max head (open tank no pressure). Patented impeller provides heavy duty high flow: 25 GPM. That is greater than almost all other 1/2 HP well pumps. Water temperature: (32 ~113 o F) Trans medium s Ph: 6.5~ 8.5 Built in capacitor start, and thermal protection for longer life and powerful start. Built in control box. This pump DOES NOT require an external control box! This is a 2 wire pump with 3-Wire (2 wires + ground wire) 1¼ discharge Designed to fit inside 4" ID or larger pipe/well casing High efficiency, hermetically sealed motor is thermally protected to prevent overheating
Type 4 Deep Well Submersible Pump, 1/2 HP Power Flow (m 3 /h) 0 1 2 2.6 3.2 3.6 4.2 4.5 Weight kw HP Flow (gpm) 0 4.6 9.1 11.5 14 16 18.4 20 (lbs) Well 0.47 1/2 Head (ft) 154 142 120 103 80 56 27 5 26 PUMP DIMENSIONS (inch [mm])
Part # 4 Deep Well Submersible Pump Power Flow M 3 /H 0 1.2 2 3.2 4 5.6 6.4 7.4 Weight HP Volt Amp Flow GPM 0 5.3 8.8 14.1 17.6 24.7 28.2 32 (lbs) MA0414X-7 1 115 10.2 H (ft) 207 195 184 161 138 82 52 11 30 MA0414X-7A 1 230 5.1 H (ft) 207 195 184 161 138 82 52 11 30 A B C D E MAX 31.2 14.5 16.7 1-1/4 3.86 4.0 4" deep well submersible pump, 7 stage, 207 feet max head (open tank). Patented impeller provides heavy duty high flow: 33 GPM. That is greater than almost all other 1 HP well pumps. Water temperature: (32 ~113 o F) Trans medium s Ph: 6.5~ 8.5 Built in capacitor start, and thermal protection for longer life and powerful start. Built in control box. This pump DOES NOT require an external control box! This is a 2 wire pump with 3-Wire (2 wires + ground wire) 1¼ discharge Designed to fit inside 4" ID or larger pipe/well casing High efficiency, hermetically sealed motor is thermally protected to prevent overheating
4 Deep Well Submersible Pump Part # Power Flow M 3 /H 0 2 3.2 4.27 5.26 6.11 7.2 7.74 Weight HP Volt Amp Flow GPM 0 8.8 14.1 18.8 23.2 27 32 34.1 (lbs) MA0419X-12A-E 2 230 10.2 H (ft) 400 369 330 288 232 171 77 5 39 MA0419X-12A 2 230 10.2 H (ft) 400 369 330 288 232 171 77 5 39 A B C D E MAX 40.9 19 21.9 1-1/4 3.86 4.0 4" deep well submersible pump, 12 stage, 400 feet Max head (open tank) Patented impeller provides heavy duty high flow: 35 GPM. That is greater than almost all other 2 HP well pumps. Water temperature: (32 ~113 o F) Capacitor start motor, and thermal protection for longer life and powerful start. MA0419X-12A has a built in control box, and does NOT require a control box! MA0419X-12A-E comes with an external control box. This is a 2 wire pump with 3-Wire (2 wires + ground wire) 1¼ discharge Designed to fit inside 4" ID or larger pipe/well casing High efficiency, hermetically sealed motor is thermally protected to prevent overheating
4 Deep Well Submersible Pump Part # Power Flow M 3 /H 0 2 3.5 4.27 5.26 6.11 7.2 7.74 Weight HP Volt Amp Flow GPM 0 8.8 14.1 18.8 23.2 27 32 34.1 (lbs) MA0431X-18A-E 3 230 17 H (ft) 625 550 480 420 340 220 42 5 54 A B C D E MAX 52.3 28 24.3 1-1/4 3.86 4.0 4" deep well submersible pump, 18-20 stage, 625 feet Max head (open tank) Patented impeller provides heavy duty high flow: 35 GPM. That is greater than almost all other 3 HP well pumps. Water temperature: (32 ~113 o F) Capacitor start motor, and thermal protection for longer life and powerful start. With a built in check valve! Comes with an external control box. This is a 3 wire pump with 4-Wire (3 wires + ground wire) 1¼ discharge Designed to fit inside 4" ID or larger pipe/well casing High efficiency, hermetically sealed motor is thermally protected to prevent overheating
Part # Power 3 Deep Well Submersible Pump Capacitor: 20µF/450V (MA0459X-14A); 55µF/250V (MA0459X-14) Weight HP Volt Amp Flow GPM 0.3 2.1 4.4 7.1 9.8 11.8 13.5 16.5 (lbs) MA0459X-14 3/4 115 9.2 Head (ft) 272 262 253 230 199 150 105 3.94 24 MA0459X-14A 3/4 230 4.6 Head (ft) 272 262 253 230 199 150 105 3.94 24 A B C D E MAX 40.5 18 22.5 1 2.9 3.2 3" deep well submersible pump, 14 stage, 265 feet max head (open tank). Patented impeller provides heavy duty high flow: max 17 gpm, and rated 10 gpm. Water temperature: (32 ~113 o F); Trans medium s Ph: 6.5~ 8.5 Built in capacitor start, and thermal protection for longer life and powerful start. Built in control box. This pump DOES NOT require an external control box! This is a 2 wire pump. Built in check valve. 1 discharge Designed to fit inside 4" ID pipe/well casing High efficiency, hermetically sealed motor is thermally protected to prevent overheating
Part # Power 3.5 Deep Well Submersible Pump Capacitor: 70µF/250V (MA0460X-9); 30µF/450V (MA0460X-9A) Weight HP Volt Amp Flow GPM 0 4.6 8.8 17.5 20.2 22.3 24.2 25.5 (lbs) MA0460X-9 1 115 12 Head (ft) 247 234 227 150 91 79 49 24 28 MA0460X-9A 1 230 5.8 Head (ft) 247 234 227 150 91 79 49 24 28 Part No. A B D E MA0460X-9 35 17.3 1-1/4 MA0460X-9A 32.7 15 1-1/4 MAX OD 3.4 3.7 3.4 3.7 3.5" deep well submersible pump, 9 stage, 240 feet max head (open tank). Patented impeller provides high flow: 25GPM (max), 13 GPM (rated). Water temperature: (32 ~113 o F) Trans medium s Ph: 6.5~ 8.5 Built in capacitor start, and thermal protection for longer life and powerful start. Built in control box. This pump DOES NOT require an external control box! This is a 2 wire pump with 3-Wire (2 wires + ground wire) 1¼ discharge. No check valve for easy winterization. Designed to fit inside 4" ID or larger pipe/well casing High efficiency, hermetically sealed motor is thermally protected to prevent overheating
Pump Protectors for Deep Well Submersible Pumps Part # Power Weight HP (pre-set) Volt (lbs) SP0456X-4A 1/2 230 6 SP0456X-7A 1 230 6 SP0456X-12A 2 230 6 Pump controller is a smart protector, for 230V deep well pump with built-in control box (internal capacitor); Protectors are pre-set for Hallmark Industries pumps, and can be adjusted for different horsepower; Shuts off pump automatically to protect the pump when water is low, or when current is too high; Comes with water 3 level sensors, manual, installation kit for accurate pump control and protection; Installing water level sensors is optional; Easy to wire with the included wiring diagram; This smart device is an efficient way to protect and extend water pump life.
TM H ALLMARK INDUSTRIIES,, INC.. 624 Estes Ave, Schaumburg, IL 60193, U.S.A. Tel: 847-301-8050 Fax: 847-301-8839 Email: sales@hallmarkind.com Website: www.hallmarkind.com PUMP SELECTION GUIDE (FOR PRESSURE TANK APPLICATION) 1. Never select a pump based on the horse power (HP)! 2. A pressure tank will reduce the pump s head significantly. 3. The key factor is the pumping level which is the static water level, not where the pump is in the well. 4. Read the chart below very carefully before you purchase a 1/2HP pump. 1/2HP pump when use a pressure tank Pressure Max water switch (pumping) level 20/40 psi 43 feet 30/50 psi 40/60 psi 24 feet 5 feet
TM H ALLMARK INDUSTRIIES,, INC.. 624 Estes Ave, Schaumburg, IL 60193, U.S.A. Tel: 847-301-8050 Fax: 847-301-8839 Email: sales@hallmarkind.com Website: www.hallmarkind.com PUMP SELECTION GUIDE (FOR PRESSURE TANK APPLICATION) 1. Never select a pump based on the horse power (HP)! 2. A pressure tank will reduce the pump s head significantly. 3. The key factor is the pumping level which is the static water level, not where the pump is in the well. 4. Read the chart below very carefully before you purchase the pump. 1HP pump when use a pressure tank Pressure switch 20/40 psi 30/50 psi 40/60 psi Water (pumping) level is no deep than 112 feet 89 feet 66 feet
TM H ALLMARK INDUSTRIIES,, INC.. 624 Estes Ave, Schaumburg, IL 60193, U.S.A. Tel: 847-301-8050 Fax: 847-301-8839 Email: sales@hallmarkind.com Website: www.hallmarkind.com PUMP SELECTION GUIDE (MUST READ!) Never select a pump based on the horse power (HP)! Many brands mark down their HP to falsely claim that their pumps use less electricity. It is common in the pump industry. So your old 1/2HP pump may actually be a 1HP pump. We do not mark down our pumps HP. But Amps won t lie. Compare the Amps, NOT HP! If a pump has max 150 head & 25 gpm, its gpm is not always 25! Gpm reduces with the increase of pumping level, from max 25 gpm (@0 head) and reduces to 0 gpm (@150 head). Read the flow curve! 150 head is to an open water tank with no back pressure! A pressure tank will reduce the pump s head significantly. 1 psi in the pressure tank equals 2.307 of head. We use our 1/2HP (max head 150 ) for 2 cases below. Case 1: To determine its flow at water level 20, 20/40 psi pressure switch : The min total head (@20 psi) = 20 + 20x 2.307 = 66 The max total head (@40 psi) = 20 + 40x 2.307 = 112.3 Read the flow chart for MA0343X-4 (MA0343X-4A). The flow at 66 is about 15 gpm, at 115 is about 10 gpm. So the pump will start at 15 gpm (@ 20 psi on) and lower to 10 gpm (@40 psi off). In this case, the head used is not 20, and flow is not 19 gpm (@ 20 ). Case 2: To decide the max pumping level (1/2HP) to a pressure tank, 30/50 psi (@50 psi): 150 50 X 2.307 = 34.65 So the water level should be less than 34 feet in order for this pump to get 50 psi in the pressure tank. If the water level is deeper than 34 feet (i.e. 38 feet), you will not get 50 psi. Fittings, and elbows etc will add resistance to the water head, and reduce the psi. Here is the chart for the pumping levels vs. psi s. Our Pump's true HP Pump's Max rated Head Max pumping level for 20/40 psi Max pumping level for 30/50 psi Max pumping level for 40/60 psi 1/2HP 1HP 2HP 150 43 24 5 207 112 89 66 Selection chart for pressure tank application 400 300 280 260