Fan Relay Board (FRBii) Assembly

Similar documents
Fan Coil Unit (FCU) Fan Motor Control

M x Series Valve Linkage Kits

CSD Series Current Devices Split Core

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

VA9104-xGA-3S Series Electric Non-Spring Return Valve Actuators

M9203-Bxx-2(Z) Series On/Off Electric Spring Return Actuators

TM-11x1 Series Room Temperature Module

M9300 Series Potentiometer Kits

M9203-AGx-2(Z) Series On/Off and Floating Point Electric Spring Return Actuators

M9109 Series Electric Non-spring Return Actuators

Installation Instructions

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

P78 Series Controls for Dual Pressure Applications

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9300 Series Switch Kits

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

VA-4233-AGx Series Electric Valve Actuators

V-2410 Three-Way Multipurpose Solenoid Air Valve

System 350 S350C Temperature Slave Stage Module

M9106-xGx-2 Series Electric Non-Spring Return Actuators

P545 Series Electronic Lube Oil Control

M9220-AGx-3 Floating Electric Spring Return Actuators

VA9905 Actuator and VG1600 Series Six-Way Valves

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

VA-7450 Series. Electric Valve Actuators

VA-720x Electric Valve Actuator

P78 Series Controls for Dual Pressure and Hazardous Location Applications

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

Two Flashes. N/A for AboveAir Units / Witt Condenser use 75 psig (set with switches 64, 8, 2, & 1 set to ON )

M Remote Mounting Kit

M Remote Mounting Kit

System 350 A350E Electronic Cooling Control

P70, P72, and P170 Series Controls for High Pressure Applications

VA-4233-GGx Series Electric Valve Actuators

M9102-AGA-2S and M9104-xGA-2S Series Electric Non-Spring Return Actuators

VA-715x Electric Valve Actuator

RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow

M9220-Bxx-3 On/Off Electric Spring Return Actuators

RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow

M9220-xxx-3 Electric Spring Return Actuators

Applications. A421 Series Standard Electronic Temperature Controls Installation Guide

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

A25 Series Warm Air Control with Manual Reset

M Valve Actuator Weather Shield Kit

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

M9000-3xx Series Weather Shield Enclosures

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

R-317 Air Flow Controller

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

RA-2000 Airflow Measuring System

BD-1600 Balancing/Zone Control Damper

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

Solstice Electric Fryers SE Series Service Manual

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

N-1001 Economizer Logic Network

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Specification Grade Contemporary Wall Mount/Technical Installation Data

System 350 A350R Electronic Temperature Reset Control (with Relay)

AD-1252 Thermal Dispersion Probe Airflow Measuring System

M9300 Series Electric Non-Spring Return Actuators

TE-6001 Hardware Assemblies for TE-6000 Temperature Elements

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Cable Cubby 1202 and 1402 Installation Guide

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

M9220-HGx-3 Proportional Electric Spring Return Actuators

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

D-3240 Series Pneumatic Piston Actuators

MOONRING 1.5 MOONRING 3

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

SHORT-STOP. Electronic Motor Brake Type A. Instructions

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

V-9502 Series Pneumatic Valve Actuator Positioners

RPM1600 Series Room Pressure Monitors

SECTION AIR TERMINAL UNITS

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

GVB-8 (Boost) Manual

Installation Instructions

ASTAT XB USER MANUAL. 1 Caution Statements

Cable Cubby 650 UT Installation Guide

poollux Power plx-pw60 & plx-pw100

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

C-5230 Pneumatic Signal Limiter

M x Series Valve Linkage Kits

IMPORTANT INSTRUCTIONS INSTALLATION AND STARTUP MODEL GDCP-A CONTROL PANEL

FS Fan-Coil Units Hi-Rise, Vertical

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

LAL SERIES LED LUMINAIRE

UNPACKING THE UNIT. Alcohol cleaning pad

Transcription:

Fan Relay Board (FRBii) Assembly Installation, Operation, and Maintenance Instructions PK-FCU030-0, PK-FCU050-0 Part No. 24-10143-1221, Rev. A Issued February 2017 Application Refer to the QuickLIT website for the most up-to-date version of this document. The Fan Relay Board assembly (FRBii) provides electronic control for the fan motor and various connections for peripheral devices. It is an incorporated control assembly that is used with HVAC equipment. The FRBii accepts incoming single phase power of nominal AC voltages 120, 208, 240 and 277. The assembly includes a multi-tap transformer (30 VA or 50 VA) that steps each of these primary side voltages to a nominal secondary side voltage of 24 VAC. The FRBii includes a regulated power supply to provide 24 VDC for fan-speed relays that allow for quieter operation than AC relay coils. The assembly allows for the control of a three-speed fan motor, including a relay for control of the neutral voltage signal path. The FRBii can be connected to an external device to control the three fan speeds. The FRBii includes logic to detect when multiple speeds are commanded simultaneously and block all but the highest of the commanded speeds from being sent to the motor windings. A signal to call for electric heat from an external controller verifies that a fan speed is selected before providing the command signal to the external electric heat control ensuring that electric heat can only be energized when the fan motor is operational. The assembly includes connectorized I/O to allow for faster installation and improved troubleshooting by the end user. The FRBii allows connection of peripheral devices (for example, thermostat controllers, electric heat relays, water valve actuators, condensate drain pan float switches, and air dampers) by either the OEM or the installer. The fan relay board also includes a fuse on the secondary side of the transformer to protect against incorrect wiring of external components that would short the transformer leads. The signals in the screw terminal block (TB1) and 18-pin black connector (J1) have a nominal voltage of 24 VAC. These signals are properly insulated from line voltage present on the assembly (J2-J5). The control assembly is a Type 1 automatic action, as defined by UL60730-1. Figure 1: Fan Relay Board (FRBii) Fan Relay Board (FRBii) Assembly Installation, Operation, and Maintenance Instructions 1

Materials and Special Tools Needed The following tools are required for installation and troubleshooting: six No. 8-3/4 in. screws digital multimeter capable of measuring 30 Volts AC/DC insulated 1/8 in. flat-bladed screwdriver fuse puller mini-hook test clips for multimeter (optional) Mounting IMPORTANT: Do not overtighten the screws. Overtightening may strip the threads and will void the warranty. Use No. 8-3/4 in. screws (quantity of six) and install the assembly in an approved electrical enclosure with the provided standoffs in the assembly. Wiring Risk of Electric Shock. Disconnect or isolate all power supplies before making electrical connections. More than one disconnection or isolation may be required to completely de-energize equipment. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. Risque de décharge électrique. Débrancher ou isoler toute alimentation avant de réaliser un branchement électrique. Plusieurs isolations et débranchements sont peut-être nécessaires pour -couper entièrement l'alimentation de l'équipement. Tout contact avec des composants conducteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. Risk of Electric Shock. Disconnect power from the controller before making any adjustments. Do not touch any part of the printed circuit board while power is applied. Failure to follow these precautions can result in personal injury or death. Risque de décharge électrique. Déconnecter l'alimentation du controller avant toute opération de réglage. Veiller à ne toucher aucune partie du circuit imprimé lorsque celui-ci est sous tension. Le non-respect de ces précautions peut provoquer des blessures graves, voire mortelles. 2

Risk of Electric Shock. Ground the FRBii according to local, national, and regional regulations. Failure to ground the FRBii may result in electric shock and severe personal injury or death. Risque de décharge électrique. Raccorder l'frbii à la terre conformément aux réglementations locales et nationales en vigueur. Le non-respect de l'obligation de mise à la terre de l'frbii risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. IMPORTANT: Use copper conductors only for line voltage terminations. Make all wiring connections in accordance with local, national, and regional regulations. Do not exceed the FRBii electrical ratings.. To wire the FRBii assembly: 1. Install the wiring in a manner that ensures it does not cause a hazard. Verify that the wiring is protected against electrical and mechanical damage. 2. Ground the assembly from the EARTH terminal (W2) to the enclosure (Figure 2). 3

Figure 2: Wiring Diagram Example 4

Ratings Table 1: FRBii Ratings Model Numbers PK-FCU030-0 (25-3034-7), PK-FCU050-0 (25-3043-15) Voltage 120 to 277 VAC Current (Fan Relays) 12 A Transformer Capacity 30 VA, 50 VA Operating Temperature -20 to 60 C (-4 to 140 F) Pollution Degree 2 Rated Impulse Voltage 4,000 V (basic insulation), 6,000 V (reinforced insulation) Inputs and Outputs Table 2: Low Voltage Peripheral Devices Screw Terminal (TB1) Signal Identification Pin Number Signal 1 Y1 - Cool 1 2 Y2 - Cool 2 3 W1 - Heat 1 4 L - Low 5 M - Medium 6 H - High 7 G - Fan Enable 8 C - Common (through JP2) 9 C - Common (through JP2) 10 R - 24 VAC 11 S2 - Auxiliary Input (Heat 2) 12 S1 - Common Table 3: Low Voltage Peripheral Devices (J1) Signal Identification (Part 1 of 2) Pin Number Signal 1 R - 24 VAC 2 S2 - Aux In (Heat 2) 3 Y1 - Cool 1 4 Y2 - Cool 2 5 LOW 6 MED 7 HIGH 8 24 V 9 24 V 10 G - Fan Enable 11 W1 - Heat 1 12 COM 13 DAMP - Damper 14 COM 15 HEAT - Heat Ouput 5

Table 3: Low Voltage Peripheral Devices (J1) Signal Identification (Part 2 of 2) Pin Number Signal 16 COM 17 24 V 18 S1 - Common Table 4: Incoming Power (J2 and J3) Signal Identification Pin Number Signal 1 NEUT 2 120 3 208 4 240 5 277 Table 5: Motor Output (J4 and J5) Signal Identification Pin Number Signal 1 LOW 2 MED 3 HIGH 4 NEUT W1 MTR PWR The MTR PWR quick connect provides voltage to the line side of the fan speed relays through an external jumper. For PSC motor, this is the line voltage of the unit. For EC motors, this is either the 24 VAC (without PWM) or a switch contact common (with PWM). W2 EARTH EARTH connection grounds the secondary side of the transformer to the enclosure cabinet through a wire bonded to the control enclosure. To install connectors J1 through J5, insert the mating connector until the locking tabs latch. The connectors are keyed and can only be installed in one orientation. To remove connectors J1 through J5, press the locking tabs to release the latch and remove the connector. To install W1 or W2, insert a female quick connect over the spade connector on the board. To remove, pull gently on the female quick connector (not the wire). Fuse A fuse is included on the secondary side of the transformer to protect the transformer from incorrect wiring of the devices (for example, thermostat and controller) that shorts the 24 VAC and COM. The fuse is a fast-acting glass body cylindrical fuse (5 x 20 mm). If tripped, replace the fuse by removing the tripped fuse with fuse pullers and replace using one of the fuses in Table 6. Table 6: Fuse Replacement Information Transformer Fuse Manufacturer Part Number 30 VA 2A Littelfuse 0235003.MXP Bussmann BK/GMA-2-R 50 VA 3A Littelfuse 0235003.MXP Bussmann BK/GMA-3-R 6

Heat Output The HEAT Output connects to an electrical heat contractor or relay. This output represents the command signal from the thermostat or controller on the W1 input. However, the output is interlocked with the fan relays to ensure that a fan speed is commanded when electric heat is requested. DAMP Output The DAMP output connects to a motorized damper actuator used to control airflow from an external source. The external source can be fresh air from outside the building or air from somewhere else inside the building. This output provides 24 VAC to energize the damper actuator. Like the electric heat output, this output is interlocked with the fan relays to ensure that a fan speed is commanded before energizing the damper actuator. Where to Install Float Switch To install a float switch, wire the float switch leads into S1 and C on the screw terminals. After wiring the float switch, remove jumper JP2. Remove the JP2 jumper for the float switch to correctly operate. If JP2 remains installed, the float switch is shorted and the unit does not respond appropriately when the float switch opens. Note: If a float switch was installed in the factory, the float switch may be connected to the J1 connector instead of wired to the screw terminal. How to Start/Stop the Fan To start or stop the fan from an external controller, wire the leads for the switch contacts (either made or broken) to R and G on the screw terminals. After wiring the switch, remove jumper JP3. Remove the JP3 jumper for the external start/stop control to correctly operate. How to Add a Remote Three-Speed Switch To add a remote three-speed switch, wire the leads for the switch to G, H, M and L on the screw terminals. After wiring the switch, remove jumper JP1. Remove the JP1 jumper for the remote 3-speed switch to correctly operate. Jumpers JP1: Speed Select Jumper This jumper is installed between 24 V and HIGH when a three-speed switch is not included (remote or unit mounted). The jumper is installed at the end of the harness connected to J1. If a three-speed switch is added later, JP1 must be removed. JP2: Float Switch Jumper This jumper is installed between S1 and C when a float switch is not installed. The jumper is removed when a float switch is installed. JP3: Fan Enable Jumper This jumper is installed between R and G/24V. The jumper is removed for remote control of the fan motor. In most instances, JP3 is installed (unless a thermostat or controller is remotely controlling the equipment). Figure 3 shows the JP2 and JP3 locations. Test Points TP1: 24VAC and TP2: COM If incoming voltage is within tolerance, then use these test points to verify the transformer is correctly producing 24 V. Connect to the test points with mini-hook test clips for a digital multimeter. Test point locations for TP1 and TP2 can be seen in Figure 3. 7

Figure 3: FRBii Jumpers and Test Positions 8

Screw Terminal Signals Table 7: Screw Terminal Signal Identification PIN Signal Internal Connections Description 1 Y1 Cool 1 J1-3 Chilled water valve actuator control input, and thermostat cooling output. 2 Y2 Cool 2 J1-4 Close input of modulating chilled water valve actuator or 2nd stage chilled water valve actuator control input, and thermostat cooling output. Y1 is Open output if floating {tristate} chilled water valve actuator is installed. 3 WI Heat 1 J1-11 J1-15 (through fan interlock relay for factory termination to EH relay) Wire connection point for hot water valve actuator or 1ststage EH control input, and thermostat heating output. 4 L Low J1-5 Low-speed control input for onboard relay. 5 M Medium J1-6 Medium-speed control for onboard relay. 6 H High J1-7 High-speed control input for onboard relay. 7 G Fan Enable J1-8 J1-9 J1-10 J1-17 J1-1 (through JP3) TP1 (through JP3) 8 C Common (through JP2) 9 C Common (through JP2) J1-12 J1-14 J1-16 TP2 J1-18 (through JP2) W2 (through JP2) 10 R 24 VAC J1-1 TP1 J1-8 (through JP3) J1-9 (though JP3) J1-10 (through JP3) J1-17 (through JP3) 11 S2 Auxiliary Input (Heat 2) 12 S1 Common J1-18 W2 TP2 (through JP2) J1-12 (through JP2) J1-14 (through JP2) J1-16 (through JP2) Used to allow external start-stop control from an external source. Device common, including onboard speed relays (all terminals C and COM on board are internally connected). Transformer hot connection (24 VAC). J1-2 Used for different functions based on application, such as: 2 nd stage heat control for two-stage EH applications Changeover water valve/aquastat for two pipe changeover applications. Close input of modulating hot water valve actuator and Close output of thermostat in floating (tristate) water valve applications. Common side of transformer. Jumped to C (common) through JP2. If application calls for float switch, JP2 is removed and float switch is connected between S1 and C. 9

Fan Relay Board Troubleshooting Guidelines Risk of Electric Shock. Disconnect or isolate all power supplies before making electrical connections. More than one disconnection or isolation may be required to completely de-energize equipment. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. Risque de décharge électrique. Débrancher ou isoler toute alimentation avant de réaliser un branchement électrique. Plusieurs isolations et débranchements sont peut-être nécessaires pour -couper entièrement l'alimentation de l'frbii. Tout contact avec des composants conducteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. The fan relay board requires no routine maintenance. Table 8 describes the screw terminal signals. Table 8: Fan Relay Board Troubleshooting Problem Possible Cause Corrective Action No 24 VAC Power Incorrect incoming line voltage Verify incoming voltage to the unit is within 10% of nominal voltage on the label. Fan Motor does not run Electric heat will not turn on Outside Air Damper actuator will not energize Improper wiring connections Blown fuse onboard (F1) JP2 removed without float switch installed Float switch tripped JP3 removed without external start/stop control installed Damaged transformer No 24 VAC power Fan speed is not commanded Fan speed is not commanded Fan speed is not commanded Verify that the unit is wired per the wiring diagram for incoming voltage. If the unit includes main fusing, verify that the fuses are not blown. Measure resistance across fuse: A properly working fuse measures < 1.0 ohms A blown fuse measures as an open circuit. Replace the fuse if blown. Use one of the replacement fuses identified in Table 6. Verify that either a float switch or a JP2 is installed. If neither are present, install one of them. Verify float switch is connected. Verify that either an external start/stop or a JP3 jumper is installed. If neither are present, install one of them. If all of the above are confirmed or revised, replace the fan relay board. See above? Verify that the fan motor is running. The fan speed may be commanded from jumper JP1, a unit- or remote-mounted three-speed switch, or a three-speed thermostat. Verify that the fan motor is running. The fan speed may be commanded from jumper JP1, a unit-or remote-mounted three-speed switch, or a threespeed thermostat, but must be commanded from one of these sources to energize the electric heat contactor on a call for heat. Verify that the motor is running. The fan speed may be commanded from jumper JP1, a unit-or remote-mounted three-speed switch, or a threespeed thermostat, but must be commanded from one of these sources to energize the damper actuator. 10

Checking Wiring Harnesses Use ohmmeter to verify that the ground wire has continuity from S1 to the enclosure case. To check the incoming power wire harness: Refer to wiring diagram. Remove power from the unit. Unplug power harness J2 or J3 connector. Unplug power wires from connections (line block, disconnect switch, toggle switch or fuse(s)) in electrical enclosure. Verify continuity of wires, then reconnect to J2 or J3 connector. To check the motor harness: Refer to wiring diagram. Remove power from the unit. Unplug motor harness J4 and/or J5 connector. Unplug motor harness from motor connection or PWM board (depending on type of motor). Verify continuity of wires, then reconnect to J4 or J5 connector and to motor or PWM board. To check the low voltage wire harnesses: Remove power from the unit. Unplug low voltage harness J1 connector and disconnect connections at other end of J1 harness. Use ohmmeter to check continuity for each conductor, then reconnect harness to J1 connector and to other connections. Before reconnecting power to unit, verify all harnesses are connected per diagram. Note: Use light force when inserting meter probe into plug. Excess force damages the contacts. European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Technologies & Solutions 507 E. Michigan Street, Milwaukee, WI 53202 PEAK and Johnson Controls are registered trademarks of Johnson Controls. All other marks herein are the marks of their respective owners. 2017 Johnson Controls. Published in U.S.A. 11 www.johnsoncontrols.com