Cessna Citation XLS - Environmental & Temperature Control

Similar documents
Pneumatic Air Conditioning System Citation, Citation I

Cessna Citation XLS - Electrical

DASSAULT AVIATION Proprietary Data

Bombardier Challenger Auxiliary Power Unit

Cessna Citation XLS - Anti-Ice & De-Ice Systems

Introduction. APU Location

Surface and Brakes Anti-Ice Systems

ATA 36 PNEUMATIC TABLE OF CONTENTS DGT ATA 36 PNEUMATIC TABLE OF CONTENTS GENERAL Introduction Sources

DESCRIPTION AND OPERATION ICE DETECTION SYSTEM

AIRPLANE OPERATIONS MANUAL SECTION 2-15

General. Airfoil Anti-Ice System

B737 NG Anti Ice & Rain

Dash8 - Q400 - Pneumatics

CFM REGULATION THE POWER OF FLIGHT

SECTION 2-14 PNEUMATICS, AIR CONDITIONING AND PRESSURIZATION

canadair chzflleriqer OPERATING MANUAL PSP 601A-6 SECTION 5 AUXILIARY POWER UNIT (APU)

DASSAULT AVIATION Proprietary Data

ATA 49 AUXILIARY POWER UNIT

canadair chaifenqer 14-CONTENTS Page 1 Feb 12/88 TABLE OF CONTENTS Subject Page GENERAL ICE DETECTION

CHAPTER ICE AND RAIN PROTECTION SYSTEM

United States Army Aviation Center of Excellence. Fort Rucker, Alabama JULY 2011 STUDENT HANDOUT

DASSAULT AVIATION Proprietary Data

OVERHEAD PANEL PROCEDURES FLASH CARDS

ASSIGNMENT Chapter 4 AIRCRAFT ELECTRICAL SYSTEMS

AIRCRAFT SYSTEMS PNEUMATIC

GENERAL The Honeywell model TFE731-40AR turbofan engine is a lightweight, two-spool, geared-stage, front-fan, jet engine.

canaaair chaiiencjer

747-8 takes advantage of new technology to offer greater capacity, increased efficiency, and improved maintainability. aero quarterly qtr_01 12

FORM: 2391 DRAWING NO: ICA-560XL Cessna Aircraft Company P.O Box 7704 WICHITA, KS 67277

TECHNICAL MANUAL AVIATION UNIT AND AVIATION INTERMEDIATE MAINTENANCE MANUAL CH-47D HELICOPTER

Dornier 328Jet - Pneumatic

CHAPTER 21 ENVIRONMENT CONTROL. Section Title Page

A AMM - ENGINE BLEED AIR SUPPLY SYSTEM - DESCRIPTION AND OPERATION

Dash8-200/300 - Auxiliary Power Unit APU CONTROLS AND INDICATORS. Page 1

Canadair Regional Jet 100/200 - Auxiliary Power Unit

General. APU Control System. APU Door System

A310 AIRCRAFT PREPARATION FOR COLD WEATHER OPERATION FCOM>>Procedure and Techniques >>Inclement Weather Operation

CHAPTER 1 AIRCRAFT GENERAL

FUEL MODEL 750 BAGGAGE COMPARTMENT SMOKE DETECTION

SECTION 5 AUXILIARY POWER UNIT (APU) TABLE OF CONTENTS LIST OF ILLUSTRATIONS. Title

CHAPTER 6 ELECTRICAL SYSTEMS

DASSAULT AVIATION Proprietary Data

DC3Training.com N28AA DC-3 Pilot s Handbook

Pilot's Manual Wcyflom v# ANTI-ICE & ENVIRONMENTAL. Learjet 31A

SD3-60 AIRCRAFT MAINTENANCE MANUAL PROTECTION DESCRIPTION & OPERATION

Canadair Regional Jet 100/200 - Fuel System

DESCRIPTION AND OPERATION

Section 5 - Ice & Rain Protection

DASSAULT AVIATION Proprietary Data

EMERGENCY GEAR DOWN HANDLE CHECK VALVE GEAR DROP TO EXTEND POSITION DOOR SELECTOR DOOR SELECTOR VALVE UPLOCK RELEASE CYLINDER DOOR CYLINDER

OPERATIONS MANUAL SECTION 6-2

Module 4: Climate Control

King Air B90. Speeds (KIAS)

CHAPTER 11. Page TABLE OF CONTENTS /02 DESCRIPTION. General Description Controls and Indicators

Basic Ice Protection System

DASSAULT AVIATION Proprietary Data

Central Warning Systems

Airbus A-320 SOLENOID THERMOSTAT (T.L.T).

Fokker 50 - Ice & Rain Protection. Controls and indicators of the AIRFRAME DE-ICING system are located at the ice protection panel.

CARENADO COPYRIGHTS. Normal & Emergency Checklist

DASSAULT AVIATION Proprietary Data

DESCRIPTION AND OPERATION FUEL SYSTEM

APICAL S-76 BAGGAGE DOOR LIFERAFT KIT

Cold Weather Operations

Singapore Airlines Flight 368 Engine Fire. Ng Junsheng Head (Technical)/Senior Air Safety Investigation Transport Safety Investigation Bureau

AIRCRAFT GENERAL KNOWLEDGE (1) AIRFRAME/SYSTEMS/POWERPLANT

5/12/2018 Climate Control - Control Components - Description and Operation 2009 Ford F-150 MotoLogic

2001 Dodge Caravan Sport MANUAL A/C-HEATER SYSTEMS Caravan, Town & Country, & Voyager

COOLING SYSTEM - V8. Cooling system component layout DESCRIPTION AND OPERATION

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

SECTION 3 EMERGENCY PROCEDURES CONTENTS

Pilot's Operating Handbook Supplement AS-03

TECHNICAL REPORT IN-021/2002

AIRPLANE GENERAL Exterior REV 3, May 03/05

Servicing. Table of Contents

LAD Inc. Beechcraft King Air 200 Series Technical Ground School Syllabus Material Covered

Jump to Table of Contents

PA32-RT LANCE II CHECKLIST

PREFLIGHT CHECK COCKPIT RIGHT WING. NORMAL PROCEDURRES CHECKLIST PA-28RT 201 Arrow IV

European Aviation Safety Agency

CESSNA CITATION C750 (CITATION X) PUNTA BRAVA S.A. (Rev Abril 2012)

TC Series Cooling Systems

TABLE OF CONTENTS Subject Page

Deicer Operating Instructions Table of Contents

The Straight Word. Beechcraft 90 King Air B90 Series. Condition Lever. Set for Takeoff Cabin Altitude Controller Set Cruise Level + 1

CIRRUS AIRPLANE MAINTENANCE MANUAL

ENGINE GROUND RUNNING

CHAPTER 4 ---AUXILIARY POWER UNIT

PA GURW (December 30, 2000) PRE-START. Langley Flying School. Airspeeds (MPH) for Safe Operation. Cockpit Checks

2015 F-250, 350, 450, 550 Super Duty DESCRIPTION AND OPERATION Procedure revision date: 04/28/2016. Climate Control System

AVANTI P180. Ground Handling

Cooling system components, removing and installing

TABLE OF CONTENTS. Chapter 1: AIRCRAFT - GENERAL Chapter 2: ELECTRICAL SYSTEM Chapter 3: ANNUNCIATOR SYSTEM...37

FULL AUTO TEMPERATURE CONTROL GENERAL 1. SPECIFICATIONS FULL AUTO TEMPERTURE CONTROL REXTON

SECTION II AIRPLANE AND SYSTEMS MODEL 750 HYDRAULIC

INSTALLATION INSTRUCTIONS EXTERNAL AUXILIARY FUEL SYSTEM P/N

/200/300/400/500 SERIES FLAMMABLE MATERIAL LOCATIONS

CHAPTER FUEL SYSTEM

Engine Emission Control 6.7L Diesel

Heating and ventilation

Transcription:

GENERAL Environmental and temperature control on the Citation XLS is provided by pre-cooled engine and/or APU bleed air. The conditioned bleed air is distributed in a series of ducts and vents. The primary means of altering temperatures in this system involves changing the amount of warm bleed air allowed to mix with cold air. The environmental control system consists of the Environmental Control Unit (ECU), the Air Distribution System, and the Temperature Control System. The various systems and their components are listed as follows: ENVIRONMENTAL CONTROL UNIT The tailcone mounted ECU is designed to take pre-cooled engine and/or APU bleed air from both engines and produce cold air for use in the temperature and distribution system. This conditioned air also serves as the source of pressurization for the entire pressure vessel. The ECU consists of a primary heat exchanger, a secondary heat exchanger, an Air Cycle Machine (ACM), a water separator and an over-temperature switch. Initially, hot engine bleed air is extracted from both engines and run through a pylon mounted air-toair heat exchanger. This exchanger lowers the temperature of the air to approximately 475 F. This pre-cooled air from each pylon is then routed together and plumbed into the primary heat exchanger, where temperature drops from 200 F to 300 F. Air is then routed into (and out of) the ACM, through the secondary heat exchanger and back into the ACM where air eventually exits at a temperature which may be well below freezing. An in-line temperature sensor constantly measures this air temperature, and automatically mixes hot bleed air to provide a constant 35 F to 40 F temperature output. This controlled temperature cold air is then run through a water separator to remove entrapped moisture. After exiting the water separator, the cold air is ducted overhead to provide cool air distribution, or mixed with bleed air and ducted toward floor and armrests to provide warm air distribution. NOTE Overtemperature protection for the ACM is provided by a temperature sensor mounted in the compressor discharge section of the ACM. When the switch senses an overheat condition in flight (temperature above 420 F), it closes the mass flow regulating shut-off valves in the tailcone, opens the emergency pressurization valve and annunciates both the EMERG PRESS ON and ACM O HEAT lights. AIR DISTRIBUTION SYSTEM When conditioned air leaves the water separator at between 35 F to 40 F, it is ducted forward to a four-outlet wye near the rear pressure bulkhead. Two of the wye ducts are plumbed into the overhead distribution system, terminating at the cockpit overhead wemacs. This overhead system contains only cold air. The remaining two wye ducts are plumbed into the cabin/cockpit warm air distribution system, and temperature in this ductwork is controlled by mixing cold air with hot bleed air. The distribution sub-systems are described in greater detail below. Page 1

the tailcone mounted ECU. On the aft side of the aft pressure bulkhead, this single line splits into the four-outlet wye. After penetrating the pressure vessel, the cold air lines (left and right) feed into left and right overhead ducts which run the length of the cabin and terminate in the cockpit. An outlet (wemac) is provided at each passenger and flight crew location. These outlets are operated individually, and may be rotated from a full open to a full closed position. This overhead distribution duct is continuously pressurized with cold air when the engines and/or APU are running and bleed air is being supplied. COCKPIT RECIRC BOOST FAN CONTROL Figure 2-21 CABIN AIR DISTRIBUTION - The lower cabin air distribution system supplies conditioned air through the left hand lower supply duct. When air enters the cabin, it is split into several paths; the left hand armrest and foot warmer ducts, the dropped aisle ducts located on the left hand side of the dropped aisle, and to the right hand armrest and foot warmer ducts. The foot warmer and armrest ducts are of a piccolo tube design that allows the air to flow evenly over the length of the cabin. COCKPIT AIR DISTRIBUTION - The cockpit air distribution system supplies conditioned air through the right hand lower supply duct. The air enters in the aft cabin and is ducted underneath the right hand seats towards the cockpit. After reaching the cockpit, the air is split off into side wall diffusers, side window defog and forward bulkhead diffusers. COCKPIT VENT SYSTEM - The cockpit vent system consists of side console air outlets, foot warmers and console wemacs which are supplied by a fan located in the foot warmer ducting. The side console air outlets are installed on the top surface of the pilot s and copilot s side consoles. The right console air outlet is connected to the cockpit air duct inside the console. The left console air outlet is supplied air through a crossover duct which extends from the co-pilot s side console to the pilot s side console and follows the lower fuselage contour. The side console air outlets are opened and closed by rotating the nozzles. The left and right foot warmer outlets are mounted in the forward crossover ducting. the side console wemacs are supplied with air pulled in from the foot warmer ducts. Air is supplied through flex ducts connected to a center outlet, between the left and right foot warmers on the forward ducting. The cockpit recirc fan is mounted in the center of the forward foot warmer duct. The cockpit recirc fan is controlled electrically by a fan switch on the co-pilot s instrument panel. Condensation on the cockpit side windows is prevented by using frost panels to prevent moist cockpit air from coming in contact with the cold outer window surface. Page 2

There is a small vent hole placed in the upper corner of the frost pane to allow the air to flow over the pane and into the cockpit. WINDSHIELD DEFOG Windshield defog is accomplished by electric windshields powered by engine driven AC alternators. The windshield heat should be turned on prior to descent from altitude to provide adequate clearing for descent into high humidity conditions. If the outside windshield fogs over after landing, the electric windshield anti-ice system may be turned to the O'RIDE position. TEMPERATURE CONTROL SYSTEM The basic principle of operation in the temperature control system is to mix a stream of cold air from the ECU (35 F to 40 F) with a stream of warm bleed air (approximately 475 F) from either engine and/or APU. This mixed air passes through the aft pressure bulkhead and is then distributed throughout the cockpit and cabin area via a series of under floor ducts and distribution points. Once inside the cabin, this air may further mix with overhead cold air to create a composite temperature conducive to passenger comfort. Two sensors measure this composite temperature and convey data to the cockpit mounted display and controller. Individual zone controls allow the flight crew to set different temperatures in the cockpit and in the cabin area (typically between 65 F to 85 F). The temperature control system consists of three temperature control valves (cabin, cockpit and ECU low limit), two mixing muffs, three duct temperature sensors, two zone temperature sensors, two duct overheat temperature switches, and the temperature controller (which is integral with the selector/indicator). TEMPERATURE CONTROL VALVES - Three temperature control valves are utilized to regulate the amount of hot bleed air mixed in with the cold air out of the ECU. Two of the valves are located just aft of the aft pressure bulkhead, and the third is located near the ECU. The ECU valve receives commands from the cockpit temperature controller, but its operation is automatic. The other two valves also receive commands from the cockpit temperature controller in response to either manual or automatic temperature change requests from the flight crew. MIXING MUFFS - The mixing muffs are devices that mix the hot and cold air streams. The mixing muff surrounds the conditioned air duct and injects hot bleed air into the conditioned air duct. The quantity of bleed air to be mixed is controlled upstream by the temperature control valves. The mixed air becomes temperature controlled conditioned air and is routed to the cabin and cockpit. DUCT TEMPERATURE SENSORS - The duct temperature sensors monitor the air temperature at three points in the system. Sensors are located near the aft pressure bulkhead (left and right lower duct locations) and downstream of the water separator in the tailcone area. ZONE SENSORS - Two zone sensors sample representative air temperature and display temperature data on the controller. Each sensor contains a small fan which pulls cabin air across the sensor to provide a more representative zone temperature. The cockpit zone sensor is located in the right hand side console. The cabin zone sensor is located in the aft cabin in the passenger service unit. Page 3

(left and right lower duct) to provide an over-temperature indication. If either switch detects an overtemperature condition (temperature exceeds 300 F), the switch will close, causing the DUCT O HEAT CKPT or the DUCT O HEAT CAB annunciator to illuminate in conjunction with the MASTER CAUTION warning. TEMPERATURE CONTROLLER - The temperature controller is mounted on the center tilt panel and provides dual zone adjustments and monitoring of both the cockpit and cabin systems. The TEMP SEL knobs provide for automatic and manual settings of the temperature (both zones), and a center knob allows the cockpit or cabin selected temperature and the cockpit or cabin duct temperature to be monitored. A digital display in the center of the controller shows temperature readout (in Fahrenheit) of the selected sensor. TEMPERATURE CONTROLLER Figure 2-22 TEMPERATURE CONTROLLER ERROR CODES - The temperature controller is equipped with bit test (B.I.T.E.) capabilities. This test is initiated each time power is applied to the temperature controller. When the B.I.T.E. is enabled, a display check and a test of the associated system are conducted immediately and on each subsequent temperature controller power-up. If system faults are discovered, one or more of the following error codes may be displayed on the temperature display. Error codes displayed are for the specific compartment selected. Page 4

Test Code Meaning 888 Test of display elements is being conducted. E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 B.I.T.E. enable and test of the associated system is being conducted. Zone temperature sensor resistance is too low. Zone temperature sensor resistance is too high. Duct temperature sensor resistance is too low. Dust temperature sensor resistance is too high. Temperature control valve closing current is too low. Temperature control valve opening current is too low. Temperature control valve closing current is too high. Temperature control valve opening current is too high. Idle current is too high. 2. An unusually hot or cold sensor may cause E1 through E4 to be displayed. These error codes will clear themselves when the sensors enter the normal operating range. The normal operation of the B.I.T.E. is with the CKPT TEMP SEL or CABIN TEMP SEL switch set to AUTO. Error codes E5 through E9 are latched and will continue to be displayed while the B.I.T.E. is enabled until a new B.I.T.E. sequence is initiated. A B.I.T.E. sequence is initiated by disabling, then enabling the B.I.T.E. by turning the system power off and back on. Page 5

ENVIRONMENTAL CONTROL SYSTEM Figure 2-23 (Sheet 1 of 2) Page 6

ENVIRONMENTAL CONTROL SYSTEM Figure 2-23 (Sheet 2) Page 7