VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

Similar documents
Independent Testing Laboratory for High Voltage Equipment

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

High Voltage Technology & Testing

PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories

HMI, APRIL, Test Laboratories in Ratingen

REPORT OF TEST ON Elastimold Molded Vacuum Reclosers (MVRs)

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

CERTIFICATE OF ACCREDITATION

Gas Insulated Switchgear

Item 1: Contents of the complete training & CV of the lecturer

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

power cable accessories

Energy Division. PCA Single Column Polymeric Surge Arrester

TEKNISK RIKTLINJE TR05-10E

Voltage limiting device HVL

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

CERTIFICATE OF ACCREDITATION

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

ANSI DESIGN TEST REPORT Report No. EU 1512-HR-00.5 Type PDV 100 Optima Heavy Duty Distribution Class Surge Arrester

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

Voltage limiting device HVL

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

Surge arrester POLIM-H..SD

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Transformer bushings, type GOH. Technical guide

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Surge arrester POLIM-H.. ND

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Product Specification

Medium Voltage Metal-Enclosed Switches

Prüffeld der Schaltwerke

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

MEDIUM VOLTAGE NETWORKS

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Product Description: Objective and Certification: Test Samples and Test Cable:

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Surge arrester POLIM-C.. HD

Shielded surge arresters

NXPLUS C Single busbar. Maintenance-free for lifetime

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Surge arrester POLIM-H..N

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Air-insulated switchgear UniGear type ZS1

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Bowthorpe EMP LV/MV Outdoor Surge Arresters

B kv T&D GAS INSULATED SWITCHGEAR

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

EE 741 Over-voltage and Overcurrent. Spring 2014

Breaking new ground. A circuit breaker with the capacity to switch 15 large power plants

PROVINCIAL ELECTRICITY AUTHORITY

Medium Voltage Metal-Enclosed Switches

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

POLYMER INSULATOR. Index

Gas Insulated Switchgear

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Accident, Maryland, USA

Overhead transmission lines Spacers

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

Our test laboratory - Apparatebau Kirchheim-Teck GmbH

VariSTAR Type AZG2 Surge Arrester, 10,000 A, Line Discharge Class 2 IEC (99-4)

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Zinc Oxide Surge Arrester EXLIM R

RI-KFUPM High Voltage Laboratory

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Technical Specification

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SWITCHGEAR DIVISION PRODUCT PROFILES

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

B kv Gas-insulated Substations

TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

OHB Outdoor sulphur Hexafluoride circuit-breaker

PORCELAIN INSULATORS

3EK7 Medium Voltage Silicone Insulated Surge Arresters

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

power pazifik Metal Oxide Surge Arrester with composite polymer insulator Type series SBK-I to IV /10.3

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

Glass insulators for kv overhead lines and substations. Global Insulator Group

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

I B D Q I B D Q O I B D Q O

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

3EK7 Distribution Class Surge Arresters. Answers for energy.

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Generic Requirements for Outdoor Telephone Network Interface Devices (NIDs)

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Transcription:

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

VEIKI-VNL Ltd. VEIKI-VNL Electric Large Laboratories Ltd. is an independent accredited testing member laboratory of Short-circuit Testing Liaison (STL) and a product certification body. The testing activities started in 1950s when Hungarian government decided to found the Institute for Electrical Power Research (VEIKI). We are accredited by the Hungarian Accreditation Board (NAT) as a testing laboratory according to ISO/IEC 17025 and as product certification body according to ISO/ IEC 17065. Our quality management system is conforming to the requirements of ISO 9001 and the environmental management follows ISO 14001 which are certified by the Hungarian Standards Institute. Testing facilities of VEIKI-VNL Ltd. are unique in Hungary, and cover the whole range of power network equipment. Our company consists of four laboratories as High Voltage Laboratory, High Power Laboratory, High Current Laboratory, laboratory for testing of equipment of nuclear power plants (LOCA Laboratory) and the Certification Office. Main activities of VEIKI-VNL Ltd. are laboratory tests, diagnostics, product certification and research & development.

High-voltage tests The testing activity of the High Voltage Laboratory covers the dielectric tests, RIV and corona tests and partial discharge measurements on equipment, cables, cable accessories, insulators, insulator sets and fittings for overhead lines and substations. The impulse voltage tests can be carried out in the indoor testing hall up to 1800 kvpeak and in the outdoor test site till 3400 kvpeak. The maximum available power frequency voltage is 700 kvrms in the indoor testing hall and 1400 kvrms in the outdoor test site. main parameters: Power-frequency voltage (Continuous current: 1 A) Direct voltage (100 ma) Lightning impulse voltage ( 0.5-5 / 10-100 µs) Switching impulse voltage ( 250 / 2500 µs ) Steep front wave voltage Superimposed single-phase voltages: Power-frequency voltage + lightning impulse voltage Power-frequency voltage + switching impulse voltage Power-frequency voltage + power-frequency voltage Three-phase synchronizing generator: Three-phase generator with adjustable frequency Single-phase transformer for RIV and partial discharge tests (500mA) Faraday cage (5m x 5m x 4m) for partial discharge test 1400 kv rms 200 kv DC 3400 kv peak 2800 kv peak 3000 kv peak /µs 1000 kv rms + 3400 kv peak 1000 kv rms + 2800 kv peak 700 kv rms + 360 kv rms 1000 V rms, 1000 A 100 Hz, 1000 V rms, 3 25 A 700 kv rms, 3 pc, 10 dbµv 60 kv rms, 1 pc

SHORT-CRICUIT tests The testing activity of High-Power Laboratory covers of short-circuit tests on different equipment as making and breaking tests, internal arc tests, power arc tests, short-time withstand current and peak withstand current tests supplied from 50 Hz power network. The synthetic apparatus of the laboratory provides the testing environment for high-voltage circuit breakers including short-line fault tests and terminal fault tests using single-phase current injection synthetic test circuit with D.C. recovery voltage. testing parameters: Test frequency 50 Hz Single-phase short-circuit power max. 1000 MVA Three-phase short-circuit power max. 650 MVA Synthetic short-circuit current breaking tests Highest TRV peak 330 kv Highest short-circuit current parameters 50 ka rms / 140 ka peak Parameters of artificial lines (SLF tests) t dl >=100 ns Power arc tests on insulator sets max. 50 ka Short-circuit tests on (bundled) overhead lines (with or without spacer-dampers) max. 50 ka rms on 62 m length max. 31.5 ka rms on 135 m length max. 20 ka rms on 250 m length Short-circuit tests on spacer-dampers max. 125 ka peak on 62 m bundle length Short-circuit tests on fittings for substations and overhead lines max. 63 ka Short-circuit tests on high-voltage surge-arresters max. 50 ka Short-circuit withstand tests supplied from low-voltage max. 170 ka rms Short-circuit tests on transformers in three-phase circuit U r-primary 35 kv; S n 16 MVA Short-circuit tests on transformers in single-phase test circuit 35 kv U r-primary 123 kv (145 kv) S n 40 MVA Short-circuit making and breaking tests on low-voltage apparatus 150 ka rms /330 ka peak at < 350V 110kA rms /240 ka peak at 430V-550V 55kA rms /121 ka peak at 690V-1100V

Temperature-rise tests Temperature-rise tests on equipment as transformers, switchgears, prefabricated substations, cables, conductors and fittings for substations and overhead lines are performed in the High-Current Laboratory up to 10 ka. Laboratory has individual supply for three-phase short-circuit tests with maximum power of 80 MVA such a way short-circuit and temperature-rise systems can be combined for special tests. Currents and more than 100 temperature magnitudes can be recorded using our analogue and digital measuring systems. Mechanical tensile tests Mechanical tensile tests on conductors, fittings and insulators can be executed up to 300 kn. Our laboratories have two tensile machines for stress-strain and breaking strength tests with lengths of 10 m (vertical) and 14 m (horizontal). The tensile machines have optional chambers for thermomechanical tests in temperature range of -40 C +50 C and for electromechanical tests up to 100 kv. Mechanical tests in special test arrangement for bending, for torsion and for mechanical impact tests or higher mechanical loads can be achieved using individual structure. Tests on overhead lines and accessories The laboratory is able to perform dielectric, corona and radio interference (RIV), short-circuit, temperature-rise, heat-cycle, sag-tension, lightning and mechanical tests as well as stressstrain, breaking, individual wire tensile, vibration, creep, sheave, galopping tests on overhead lines. Corona, RIV tests and numerous mechanical tests can be performed on accessories of the overhead lines like spacer-dampers and stockbridge-dampers. Tests on cables and accessories Dielectric, temperature-rise, heat-cycle test, electrical ageing in dry or wet environment, shortcircuit on core, screen and flammability test can be carried out on cables and cable accessories.

Pollution and ageing tests Ageing, heat-cycle ageing, accelerated ageing test and pollution tests can be carried out in our laboratories on cables, fittings for conductors or substations, insulators or materials and on special equipment. There are hermitically closed test chambers for different tests in humidity, wet, salt fog, clear fog, high-temperature, lowtemperature, high-pressure or high intensity UV environment, meanwhile the electrical properties of the test specimen can be monitored. LOCA tests for nuclear power plants The purposes of the Loss Of Coolant Accident (LOCA) tests to verify the operability of electrical equipment in case of malfunction for areas require very high reliability as nuclear power plants. An occasional malfunction can be modelled in our accident simulation chambers with variable thermo hydraulic parameters (temperature, pressure, steam, high humidity and condensation).

Development of testing equipment and methods VEIKI-VNL Ltd. founded a division for serving the support of the measuring technique and develops new testing or diagnostics equipment and software as follows: Method and equipment for corrosion detection of ACSR conductors Method for power line diagnostics Software for the short- circuit temperature rise calculation of conventional and OPGW conductors Data base management and evaluation software for overhead line diagnostics Rogowski-coil current measuring system up to 200 ka with accuracy of 0.5% Michro-ohm meter with max. test current of 200 ADC with accuracy of 0.2% Modular multichannel optical transient recorder with sampling rate of 500 khz with accuracy of 0.1% Extra services Binocular, image intensifier (photo multiplier) equipment and day-light UV camera for detection of visible corona Digital high-speed video camera up to 6000 fps (2000fps in full resolution) for evaluating flashovers and mechanical tests or the behaviour of the plasma channel during the power arc tests on insulator sets (Optical) pressure measurements during internal arc tests or breaking tests or for short-circuit tests on liquid-immersed equipment Infrared thermos vision camera for detecting hot spots on equipment

References /partners Contacts: VEIKI-VNL Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY Phone: +36 1 417 31 57 Fax: +36 1 417 31 63 www.vnl.hu vnl@vnl.hu