AZM300 More than just a solenoid interlock

Similar documents
More than just a solenoid interlock AZM300

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Solenoid interlock AZM 200 The non-contact interlock.

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Safety Sensor CSS 180 Product Information

Operating instructions Solenoid interlock AZM About this document. Content

Safety door-handle system STS

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Transponder-coded. with guard locking

Workshop Solenoid Interlocks

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Transponder-coded. with guard locking

AZM 161SK 12/12RKED/TU 024

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

IDEM MPC Non-Contact Coded Magnetic Safety Switches MPC Series Plastic Housing

Guard locking systems for the protection of man and machine

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Safety Control HR1S-AC. Safety Relay HR1S-AC

Sense7-series Non-contact coded safety switch

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

IP69K Stainless Steel Safety Interlock Switches

F3S-TGR-KHL1/-KHL3/-KHL3R

Datasheet. Electrical Switching / Locking

Industrial communication AS-Interface instead of complex wiring

Universal Gate Box with Safety Interlocking TYPE: UGB-KLT FEATURES & APPLICATION:

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet

CAUTION CM-SE CM-S21 CM-S41

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Technical data. Standards: IEC/EN BG-GS-ET-15

Lexium integrated drives

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Safety stop buttons Smile, INCA and Compact

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

ABB i-bus KNX DG/S x DALI-Gateway Basic

NHP SAFETY REFERENCE GUIDE

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

NHP SAFETY REFERENCE GUIDE

LR-LX-LK-LW Safety Switches with separate actuator

EH170U Twinlift Mobile Harbour Crane Spreader

EH5U Single Lift Mobile Harbour Crane Spreader

Safety interlock switch MKey

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

YSX40E All Electric Yard Crane Spreader

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Session Four Applying functional safety to machine interlock guards

Safety. Detection. Control. EOS4 - EOS2. Type 4 - Type 2 Safety Light Curtains. Product catalogue

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Tandem E 3 Ship to Shore Spreader

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

EOS4. Safety level: Type 4 SIL 3 SILCL 3 PL e Cat. 4

proat Head Options & Ordering Information Part Number Item No. Description T6 ITM proat Head

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Protecting People, Industry and Productivity

Hinge Wing Safety Interlock Switches

EOS 2. Safety level: Type 2 SIL 2 SILCL 2 PL d Cat. 2

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Modular pneumatic valve island

SSX40 Ship to Shore Spreader

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

ABB JOKAB SAFETY Products. Material handling industries Machine safeguarding products

MKey9-series Safety Interlock Switch with Guard Locking

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

60Hz UP6 15, UP6 20, UP6 25, UP6 30

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

ARCAPRO positioner. Positioner customized for specific tasks

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

FUNCTIONAL SAFETY SOLUTIONS in Solenoid Valves

IDEM Solenoid Interlock Safety Switches

Limit Switches and Safety

SG-B1 SERIES / SG-A1 SERIES

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

Safety Interlock Switches

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

PD-Series Ground Fault Circuit Protection

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Data Sheet. AmLok.

Lexium integrated drives

Freefall metal detection system Vistus with separator ST 2.0

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

Tandem Fix 40 Ship to Shore Spreader

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Modular electrical and pneumatic automation system

Thermal Overcurrent Circuit Breaker 3120-F...

Transcription:

AZM300 More than just a solenoid interlock

AZM300 The one for all Symmetrical mounting for right- and left-hinged doors Only one version for hinged and sliding doors Compact design Can be used as end stop 3 actuating directions High tolerance to door misalignment Holding force 1,000 N Switchable latching force (25 N / 50 N) PL e / SIL 3 Series-wiring without reduction of the safety level More than 30,000 different codings Serial diagnostic Low power consumption

mounting situations Power to lock or power to unlock Actuator or solenoid interlock monitoring Hygiene-compliant design: resistant to many cleaning agents Protection class IP69K Manual release Easily mounted to standard extrusion guards LED status indication 200ms delayed locking to ensure door closure and reduce stress on locking mechanism

Protection against hazardous inertial movements One of the unique features of the AZM300 is the innovative patented operating principle with rotating shaft and star handle. This operating principle offers the advantage that the safety guard is pulled into its end position upon closing the guard door and it is held shut. The solenoid interlock can be used as an end stop, which eliminates the use of a separate door stop. The integrated latching ensures that the closed condition of the door is maintained after the unlocking of the solenoid interlock and that the door cannot autonomously open itself. The latching force can be easily increased by turning the star handle by 180 from 25 N to 50 N. For safe identification of the actuator an RFID sensor is used, featuring three different coding levels thus providing protection against defeat. Fields of application Packaging machinery Wood-processing machinery Printing machines and presses Handling and assembly technology Special-purpose and customised machine construction Food-processing industry Pharmaceutical industry Printing machines and presses

Identical mounting for left and right hinged doors Protecting humans and machines The safety outputs of the AZM300Z solenoid interlock (solenoid interlock monitoring) are enabled when the safety guard is closed and the solenoid interlock is locked. For applications where process protection is required, the AZM300B version (actuator monitoring) can be used. The safety outputs of this model are enabled when the safety guard is closed and can be locked. With this device locking is not required for operation, however the ability for a proper locking is still monitored. Three actuating directions Acutation from the rearside Actuation from the slim side Actuation from front

Automatic teaching after the operating voltage is switched on Minutes 10 minute restart inhibit following the teaching procedure of a replacement actuator Protection against defeating through individual coding If interlocking devices are defeated, the machine is not operated under the conditions foreseen by the manufacturer. The result could be a significantly increased residual risk for the operator, possibly much higher than acceptable. If the defeating incentive cannot be eliminated completely by modified or additional modes of operation, then the designer has only one element left. This is to make the defeating of interlocking devices more difficult or even impossible. (Excerpt from pren ISO 14119). The basic version of the AZM300 accepts any suitable target. A second version only accepts the actuator that has been taught upon the first activation. And finally, a third variant is available; here, the teaching process can be repeated an arbitrary number of times. In this way, the user can choose the most suitable coding variant for the intended application as well as the desired degree of protection against defeating. This is enabled by integration of the RFID technology into the safety sensor technology. Teaching actuators without additonal tools The AZM300-I1 and AZM300-I2 versions with individual coding, no tool whatsoever is required for the actuator teaching procedure. The teaching process starts automatically as soon as the device is switched on. The user must connect the solenoid interlock to the operating voltage and bring the actuator into the detection range. After approx. 10 seconds, a brief cyclic flash of the AZM300 LED indicates to remove the operating voltage. Next the operating voltage is switched back on and the actuator must be placed in the detection range once again to activate the actuator code. For ordering suffix -I1, once the actuator coding process has been completed it is irreversible. For ordering suffix -I2, the teaching procedure for a new actuator can be repeated an unlimited number of times. A restart inhibit period of 10 minutes prevents the last-minute change of an actuator, thus increasing the protection against tampering.

Serial diagnostic Similar to all electronic safety sensors and solenoid interlocks from Schmersal, the AZM300 is also available with serial diagnostic. Solenoid interlocks with serial diagnostic feature have a serial input and output cable instead of the conventional diagnostic output. When solenoid interlocks are wired in series, the serial diagnostic cables are wired in series, in addition to the safety channels. The thus created "common diagnostic line" is wired to a serial Diagnosic Gateway for evaluation. Up to 31 different Schmersal electronic safety devices can be wired in series. For the evaluation of the serial diagnostics line either the PROFIBUS-Gateway SD-I-DP-V0-2 or the Universal-Gateway SD-I-U- are used. This serial diagnostic interface is integrated as a slave in an existing field bus system. In this way, the diagnostic signals can be evaluated by means of a PLC. In addition to the comprehensive diagnostic and status information, the solenoid interlock is locked or unlocked through the diagnostic cable. The device can be wired either directly to the machine through a special Y-adapter or in the control cabinet by means of terminal blocks. Because of the use of serial diagnostics, an input (diagnostic) and an output (locking signal) can be saved for each device in the PLC. Hygiene-sensitive applications Packaging machinery

➄ ➊ ➅ ➆ ➋ ➃ ➌ The AZM300 in detail Legend ➀ High degree of protection against tampering because of the coded RFID sensor (also available with individual coding) ➁ Dampener for door stop - saves costs: no additional mounting parts required ➂ Star handle - adjustable latching force - 25 N or 50 N ➃ Mounting hole for M6 screws ➄ Connector plug M12, 8-pole ➅ Manual release ➆ LED display Features ± 2.0 mm ± 3.5 mm Large actuator tolerances Actuator tolerance in longitudinal direction ± 3.5 mm, lateral direction ± 2.0 mm Easy latching force adjustment The latching force can be increased from 25 N to 50 N simply by turning the star handle 180. Position I: approx. 25 N, Position II: approx. 50 N LED display Smart diagnostic by means of 3-color LEDs LED green: Power LED yellow: Status LED red: Fault

Technical data Technical data Holding force: Latching force: Mechanical life: End stop: Protection class: Dimensions: 1,000 N 25 N / 50 N > 1,000,000 operations 5 kg guard door, 0.5 m/s 50,000 operations IP66, IP67, IP69K 100 x 85 x 35 mm Supply voltage: 24 VDC 15% / +10% Electrical connection: Connector plug M12, 8-pole Outputs: 2 p-type safety outputs, 1 p-type diagnostic output or serial diagnostic Diagnostic and status display: 3 LEDs Classification: PL e / SIL 3 Approvals: Solenoid monitored Actuator monitored Power to unlock Power to lock Universal coding Individual coding Diagnostic output Serial diagnostic Ordering details Ordering code AZM300Z-ST-1P2P 103001435 AZM300Z-ST-1P2P-A 103001450 AZM300Z-I2-ST-1P2P 103001439 AZM300Z-I2-ST-1P2P-A 103001454 AZM300Z-ST-SD2P 103001436 AZM300Z-ST-SD2P-A 103001451 AZM300Z-I2-ST-SD2P 103001440 AZM300Z-I2-ST-SD2P-A 103001455 AZM300B-ST-1P2P 103001411 AZM300B-ST-1P2P-A 103001423 AZM300B-I2-ST-1P2P 103001415 AZM300B-I2-ST-1P2P-A 103001427 AZM300B-ST-SD2P 103001412 AZM300B-ST-SD2P-A 103001424 AZM300B-I2-ST-SD2P 103001416 AZM300B-I2-ST-SD2P-A 103001428 Version I1 with individual coding upon request. Door detection monitoring featured on all versions. Actuator AZ/AZM300-B1 101218025 Mounting plate AZM300 MP-AZ/AZM300-1 103003172 Mounting set actuator MS-AZ/AZM300-B1 103002891 Connector M12, 8-pole,IP67, 2,5 m A-K8P-M12-S-G-2,5M-BK-1-X-A-2 101209963 Connector M12, 8-pole,IP67, 5 m A-K8P-M12-S-G-5M-BK-1-X-A-2 101209964 Connector M12, 8-pole,IP69K, 5 m A-K8P-M12-S-G-5M-BK-1-X-A-4-69 101210560 Connector M12, 8-pole,IP69K, 10 m A-K8P-M12-S-G-10M-BK-1-X-A-4-69 103001389

Electronic safety sensors Sensor AZM300 102.6 9.2 78 34.4 25 Ø6.5 Ø6.3 Ø34 43 87.4 17.5 95.3 120.3 Thermoplastic enclosure 2 short-circuit proof, p-type safety outputs (24 VDC per 250 ma) Increased protection against tampering by optional individual coding of safety sensor and actuator Adjustable latching from 25N to 50N Safety and diagnostic signals can be wired in series Integral cross-wire, wire breakage and external voltage monitoring of the safety cables up to the control cabinet LED status indication Robust design using cleaning agent-resistant materials achieving protection class IP69K Approvals 13.3 Actuator AZM300 35 18.5 Thermoplastic Solenoid actuator key Dampener for end stop RFID tag Approvals 127 55 16.4 Ø6.7 23.4 Ø5 37.4 Certification in combination with safety sensor Technical data Standards: IEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN ISO 13849-1 Enclosure: glass-fibre reinforced thermoplastic Mode of operation: RFID Actuator: AZ/AZM300-B1 Series-wiring: unlimited number of components, up to 200 M; max. 31 components for serial diagnosis Connection: Integrated connector M12 - Integrated connector: M12, 8-pole, A-coded Switching distances to IEC 60947-5-3: Rates switching distance S n : 2 mm Assured switch-on point S ao : 1 mm Assured switch-off point S ar : 20 mm Minimum distance between two sensors: 100 mm Ambient conditions: Ambient temperature Tu: 0 C +60 C Storage and transport temperature: -10 C +90 C Protection class: IP66 / IP67 to EN 60529; IP69K to DIN 40050-9 Mechanical Data: Resistance to vibration: 10 150 Hz, amplitude 0.35 mm Resistance to shock: 30 g / 11 ms Electrical data: Switching frequency f: 0.5 Hz Response time: 120 ms Duration of risk: < 200 ms Standby delay: 5 s Rated Supply voltage U s : 24 VDC -15% / +10% (PELV) Power consumption with solenoid enabled: 0.25 A Power consumption without load: Required rated short-circuit current: 0.1 A 100 A Ordering details Ordering details Ordering details AZM300 ➀ - ➁ -ST- ➂ - ➃ No. Option Description ➀ Z Guard locking monitored B Actuator (RFID) monitored ➁ I1 I2 Standard version Individual coding (Irreversible) Individual coding (re-teachable) ➂ 1P2P Diagnostic output SD2P Serial Diagnostic ➃ A Power to unlock (spring lock) Power to lock Actuator AZ/AZM300-B1 Connector Cables A-K8P-M12-S-G-5M-BK-1-X-A-4 IP69K cable, 5 meter length A-K8P-M12-S-G-10M-BK-1-X-A-4 IP69K cable, 10 meter length A-K8P-M12-S-G-5M-BK-1-X-A-2 IP67 cable, 5 meter length A-K8P-M12-S-G-10M-BK-1-X-A-2 IP67 cable, 10 meter length Mounting MP-AZ/AZM300-1 Spacer plate MS-AZ/AZM300-B1 Mounting kit for actuator

NOTES

Electronic Safety Sensor & Solenoid Interlock Product Family CSS180 CSS34 CSS30S Schmersal offers a wide selection of Electronic safety devices which are designed to help solve application challenges for industry while enhancing operator safety. Non-contact sensor principle 3 color LEDs indicate status, error codes AZ200/AZM200 MZM100 CSS16 Integrated dual monitoring microprocessor provides continuous internal function tests Highest level of safety: PLe per ISO 13849-1, SIL3 per IEC 62061 Wired in series without detriment to safety level Serial Diagnostic option for connection to PLCs RFID allows for individual coding of actuators RSS36 AZM300 The available features from the Schmersal electronic family provide our customers multiple options when selecting the appropriate product for any application. USA 660 White Plains Road Suite 160 Tarrytown, New York 10591 Tel: (914) 347-4775 Fax: (914) 347-1567 E-mail: salesusa@schmersal.com www.schmersalusa.com Canada 15 Regan Road Unit #3 Brampton, Ontario L7A 1E3 Tel: (905) 495-7540 Fax: (905) 495-7543 E-mail: salescanada@schmersal.com www.schmersalcanada.com AZM Rev1 7/13