High Pressure Bypass System Type SOV acc. to TRD 421

Similar documents
SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

Yarway Narvik Desuperheater Model 18/54 and 28/64 Heavy Duty

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

Injection Desuperheater

Purpose & Advantages. The ARTES desuperheater can be actuated by means of electric, pneumatic or hydraulic drives.

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

PREHEATER BYPASS SYSTEMS

OLYMPUS. Gas Turbine Fuel Controls. Building of complete custom designed fuel systems. Single or serial production quantities

DVG/AF Variable Geometry Desuperheater

Heavy Duty Que - Temp Desuperheater Model: 13 / 23

High Pressure Turbine Bypass Valve HBSE

FM SAMUANG TURBINE BYPASS SYSTEM

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Electrohydraulic Drive System EHC-A

YARWAY NARVIK MODEL 33/43 STANDARD DUTY QUE-TEMP DESUPERHEATER

OAKLEAF INVESTMENT HOLDINGS 52 (Pty) ltd

FLOW TEK VALVES & CONTROL S INC

Starting up hydraulic systems

Product Overview SAFETY valves. Sempell ǀ product overview SAFETY valves

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

TempLowHT Steam Desuperheater Model: 59/69/79

Typetested versions With Type 3213 Globe Valve, unbalanced. With Type 3214 Globe Valve, balanced

Standard Duty Que - Temp Desuperheater Model: 33 / 43

Aeroflow SCV Steam Control Steam Conditioning Turbine Bypass Valve

High End Technology. Tight Shutoff. Reliability. Expertise you can trust. General Products

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

High CATALOG. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

Steam-Conditioning Valve

DESUPERHEATER (SERIES 800)

Series DK Type DKV and DKM

Pressure degassing systems

DRAG VLN Turbine Bypass Valve for Hot Reheat Bypass Applications

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

Specially designed low-maintenance control valves for a wide range of applications in water circulation

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

BOSS Series D Control Valve

Operating & Maintenance Manual For Steam Conditioning Valve

A MEMBER OF THE ARCA FLOW GROUP

Valves and Solutions for Power Plants. Engineering GREAT Solutions

BULLETIN 1163 MARCH 2002 TURBINE BYPASS SYSTEMS

Yarway Narvik Model 37 and 47 Cryogenic injector

DESYsmart / TESYsmart steam test unit

Fuel control. The fuel injection system tasks. Starting fuel pump (FP)

SAFETY QUICK SHUT-OFF VALVES FOR OIL. Safety devices with automatic shut-off function ASV DN 15, 20, 25 KVAZ DN 32, 40, 50

Pilot-Operated Regulators

Series TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection

abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 210 MKII LOW TEMPERATURE CELL SAMPLER

Control Ball Valve Type W

Series DK. Type DKV. Desuperheaters to control the Temperature of Superheated Steam (or Gas)

VELOCITY CONTROL TECHNOLOGY DESUPERHEATERS

ARI-FABA -ANSI LongLife Stop valve with bellows seal

Electro hydraulic actuating system is a complete modular unit with a wide range of actuator cylinders (type ASM) having a

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

Crown Actuated Valves & Controls

Turbine Bypass. Systems

DBOY Series Pneumatic Control Valve

Control Ball Valve Type G

SAMPLE SPECIFICATIONS

asfa actuators Welcome

Automatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection

Standard Duty SLN - Temp Desuperheater Model: 50 / 60

Si 6303 / Si 6304 / Si 6305

Typical Feed Water Heater Isolation System.

TRUNNION MOUNTED METAL SEATED BALL VALVES

Pressure reducing valve Pressure reducing valve in straightway form DN

Purpose & Advantages

CONTROL CHOKE SINCE1958. Unique. Precise. Quality. Reliable.

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Sempell controlled non-return or Bled Steam Check Valves prevent unallowable pressure built up in the turbine coming due to back-flowing steam.

VAD Variable Area Desuperheaters

Spring Loaded Safety Valve. SiC 11/13/14

VG6000 Series Forged Brass Valves

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

A E R Z E N S C R E W C O M P R E S S O R S

Tips & Technology For Bosch business partners

Every component precisely matched

Metrovick F2/4 Beryl. Turbo-Union RB199

Cast iron Nodular iron BR 006/306 Page 2. BR 006/306 Page 2. Forged steel BR 006 Page 3. Stainless steel BR 006 Page 3. Forged steel BR 005 Page 5

Fisher TBX Steam Conditioning Valve

Si Engineering GREAT Solutions. Steam Safety Valves to PED and DIN/EN standards

: Automation Laboratory 1

Cast iron Nodular iron BR 006/306 Page 2. Cast steel BR 006/306 Page 2. Forged steel BR 006 Page 3. Stainless steel BR 006 Page 3

TRIPLE OFFSET BUTTERFLY VALVE TYPE LTR 43

DESCRIPTION AND OPERATION

MNSD-V & MNSD-U. Multiple Nozzle Spray Desuperheater

So how does a turbocharger get more air into the engine? Let us first look at the schematic below:

Delivery Programme for Shipbuilding and Industry Valves, Fittings, Engineering and Service

VALVOLE. Choke Valves Gate Valves WellHead Control Panels Control Systems Oil & Gas Upstream Equipment CELEBRATING

CASH VALVES TYPE G-60 PRESSURE REGULATORS

CASH VALVES TYPE G-60 HIGH CAPACITY PRESSURE REGULATOR

High Flow Safety Valves

SECTION METERS AND GAGES FOR PLUMBING PIPING

APPLICATIONS IN PALM OIL MILL - CONTROL VALVE - DESUPERHEATER -PRDS -FLOWMETER -GAUGES

Transcription:

High Pressure Bypass System Type SOV acc. to TRD 421 GS valve engineering GmbH Phone: +49-208-833 2090 sales@gs-valve.eu Duisburger Strasse 375 Fax: +49-208-833-2095 www.gs-valve.eu 46049 Oberhausen GERMANY

1. Application The safety overflow valve combination covers the ranges resulting from the operation of a power station system where the turbine cannot or can only partly absorb the steam produced by the boiler. In the following cases of operation, the safety overflow valve ensures that the steam passing through is cooled before reaching the reheater system. a) When starting up the boiler (cold, hot, superheated start): The safety overflow station controls the free orifice crosssection of the main valve so that the maximum permissible pressure and temperature change velocity in the boiler is not exceeded and the vapour pressure is maintained at or, during a cold start-up, reduced to a minimum. b) During start-up of the turbine, the function of the safety overflow valve is to control the transfer of the generated vapour output of the boiler to the turbine. The free orifice cross-section of the main valve is closed as the turbine inlet valves open. The transfer process is completed when the turbine has absorbed all the generated steam and the safety overflow valve is closed. c) Control during output operation: The valve has the function of discharging the excess vapour in the event of relatively rapid drops in output and of absorbing pressure peaks. d) The safety devices must ensure that, in the event of all possible failures during operation, the vapour pressure in the boiler and in the live steam system of the station does not exceed the maximum permissible value. The safety overflow valve must satisfy the safety function and be able to discharge the maximum supply of vapour generated by the boiler into the cold reheater station. - 2 -

2. Construction and Function 2.1 Safety Overflow Valve (SOV): The valve with its electro-hydraulic control system corresponds, as regards its construction and function, to the safety recommendations of the German vapour' boiler commission (Deutscher Dampfkesselausschuß). lt closes against the vapour pressure and the conical surface and against the opening spring assembly with its centrally positioned oil cylinder which is subjected to pressure from above. The valve thus operates on the pressure relief principle. The reduction in the pressure of the vapour is effected with the proven principle of stepped relief which guarantees low noise and vibration levels The cooling water is injected via two lateral studs on the outlet stud downstream of the silencer where it is immediately atomized by high-pressure atomising steam coming through the valve stem and top flange into the ring nozzle - 3 -

A particular advantage of this design is that in every control position, the water supply is effected in a high-velocity partial vapour stream. This guarantees perfect fine water atomization combined with the vapour cooling. As experience in many power stations has shown, damage due to thermal shock is thus practically impossible. In addition, the performed cage and the outlet side protects the pressure-bearing valve outlet housing against thermal shock. case of safety operation, irrespective of the particular control position selected. The use of limit switches permits the valve stroke to be limited so that in the event of safety action, an excess of water is not supplied. Independently of this fact, the control system is able to drive the valve beyond this stroke limit to a position required to achieve the nominal temperature required in the cold reheater station. Subsequent adjustment of the valve stroke, and thus of the output, can be performed (in the presence of personnel of the German Industrial Safety Authority, TÜV) with a simple screwed connection. 2.3 Injection Shut-Off Valve (STV): This open-closed valve is normally installed in front of the injection control valve (2.2) for advance shut-off and, with the exception of the inner trim, is identical to it. 2.2 Injection Control Valve (SPV): The design of the injection control valve is based on the type proven for many years. The purpose of the shut-off valve is to prevent water from entering the cold reheater station in the event of a leak in the control valve. The valve seat can be replaced without the valve itself having to be removed from the line. Control operation is effected by a centrally mounted hydraulic piston actuator. The valve is closed as the oil pressure is increased. A central spring assembly operates in opening direction. It also serves the rapid opening of the valve in the - 4 -

2.4 Electro-Hydraulic Control System with Safety and Test Device: The electro-hydraulic control system consists primarily of the common oil supply for all the valves, the hydraulic cylinders required to operate.the valves and the separate hydraulic link-up for control and regulation of each valve In accordance with the demands for greater availability, the oil supply system has two pump aggregates, each of which is dimensioned for the entire output required. If the pump or electric motor of the aggregate currently in operation fails, a hydraulic switch automatically turns on the second aggregate. The actuation cylinders of the valves are loaded on the one side against springs with oil pressure. Control is effected continuously via proportioning valves or in steps via solenoid valves. The electric modules for control, regulation and safety switching are installed in a separate control cabinet mounted on the side of the oil supply unit. The outside of the control cabinet contains signalling elements for all the important functional equipment which indicates the defective unit in the event of a failure. The collective failure signal on the control cabinet can also be signalled in the control room. If the vapour pressure increases beyond the permissible value, the safety device is actuated via bourdon tube switches in the vapour test sampler. In accordance with the safety regulations, this device is designed on the three-line principle and is circuited at least twice in accordance with the closed-circuit principle. Furthermore, it is possible to actuate the safety device via an additional relay, independently of the vapour test sample. When the signal for rapid opening of the valves has been cancelled, the valves return to their preset control position. After the safety device is actuated, the oil from the operating cylinder of the valves is forced back into the oil tank in the desired time (min. 1.5 seconds, adjustable via throttles in the return line). - 5 -