Free position locking flat and compact cylinder UFCD Series

Similar documents
Light weight clamp cylinder CAC-N32/40 Series Light weight position locking clamp cylinder UCAC-N32/40 Series

Mechanical power cylinder

Super-Mini Complete with Easy-to-Use Functions. Guided Cylinder. STM Series GUIDED CYLINDER STM SERIES CC-884A 1

Features. Maintenance is simplified with the separable scraper section adapter.

Balancing Unit BBS Series

GUIDED CYLINDER STG SERIES

New Products. 3 Port Solenoid Valve with Spool Position Detection SNP Series

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

Compact Cylinder SSD2 Series

Linear slide cylinder Double acting single rod type. Bore size: 4.5, 6, 8. Descriptions Bore size mm

Medium bore size cylinder Double acting, non-rotating type. CMK2-M Series. Bore size: 20, 25, 32, 40

MSDG Series. Axial space saving structure and precise guided type. High precision, high rigidity and space saving High precision guided

New Products. Speed Control Valve with Adjusting Dial. DSC series SPEED CONTROL VALVE WITH ADJUSTING DIAL DSC SERIES. Visible Flow Rate!

HFP Series. Specifications. Switch specifications. Wide parallel hand Double acting. Operational stroke length: 20, 30, 40, 60mm.

Position locking clamp cylinder. UCAC2 Series. Bore size: ø50, ø63. Double acting single rod type

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Lateral parallel hand Double acting. Operational stroke length: 20, 30, 40mm. 980m/s2

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Plug-in manifold W4G4 Series

King Of Valve Co.,Ltd.

Guide Table. ø40, ø63, ø100

Guide with rated load approx. 1.5-fold higher incorporated!

INSTRUCTION MANUAL FOR

Design & Selection. Installation & Adjustment

Guide Table. MGF Series

Compressed air to

New Product. High speed transfer 0.5 sec./cycle realized. Linear type P&P unit. PPLX Series PPLX SERIES CC-N-371A 4

HMV/HSV. Manual selector valve. 4-port valve CONTENTS

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

Energy efficiency and Flow

Series MGPS. Compact Guide Cylinder: ø50, ø80 MGP S Z73. How to Order. Applicable auto switches. Compact Guide Cylinder.

For material handling and clamping of small workpieces

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

Compact Guide Cylinder

Guide Table. Series MGF

Series variation. STS/STL Series. Guided cylinder. STS/STL Series. : Standard, : Option, : Custom order, : Not available Bearing method.

Compact Cylinder/Plate type

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

CAT.ES20-53 E. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Vacuum pump system type

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations.

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Series CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations.

CAT.ES C. Compact Guide Cylinder. SeriesMGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. New end lock type introduced to Series MGP

2 port pilot operated solenoid valve

Exhaust Throttle (Needle) Valve ET

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Rotary Table/Vane Style

Series C95N. ISO/VDMA Cylinder: With Lock Type Double Acting, Single Rod. ø32, ø40, ø50, ø63, ø80, ø100. How to Order

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Bore size: JSC3: φ40/φ50/φ63/φ80/φ100. JSC4: φ125/φ140/φ160/φ180

Multi-Circuit Rotary Block

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

SRM3. High precision guided rodless cylinder. ø25 ø32 ø40 ø63. Rodless type

Series C95 ø32, ø40, ø50, ø63, ø80, ø100

Speed Controller High Flow

Compact Guide Cylinder with Lock

Series MSU. Rotary Table Vane Style. High Precision. Size: 1, 3, 7, 20 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D mm or less.

Compact Guide Cylinder Series MGQ

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions

22mm Space required between the bottom of the cylinder body and your equipment is reduced.

HN B G1/US B G2/US B G3

Related vacuum products

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting

Custom stroke length (per mm) Axial foot type both sides. Max. stroke length (mm) Min. stroke length (mm) Axial foot type single.

King Of Valve Co.,Ltd.

CVE2/CVSE2 CVE3/CVSE3

Compact Rotary Actuator

HMV/HSV. Manual switching valve. 4 port valve

HBL Series. Specifications. Switch specifications. Fulcrum hand Double acting/single acting. Open and close angle: -5 to 20. Descriptions 2CS 20 1C 15

Compact direct acting precision regulator

Compact Rotary Actuator

Heavy Duty Stopper Cylinder

Mini Rotary Actuator/Rack & Pinion Style

Dual Rod Cylinder. ø6, ø10, ø15, ø20, ø25, ø32. Dual rod cylinder with guide function suitable for pick & place applications.

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

Rotary Actuator/Vane Type

Miniature Regulator Series ARJ310

Series RSH/RS1H. To stop pallets gently. Heavy Duty Stopper Cylinder. Stopper cylinder with built-in shock absorber. ø20, ø32 ø50, ø63, ø80

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

and High precision guide provided High cylinder position accuracy, and wide guide realizes radial moment resistant high rigid structure.

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Mini Rotary Actuator/Rack & Pinion Style

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

Specifications Fluid. Basic Roller lever. Mechanical operation. One way roller lever. Roller plunger. Push button (Flush) Manual operation

Mini Free Mount Cylinder

ACTUATORS GENERAL CATALOG

Compact Guide Cylinder

Free Mount Cylinder for Vacuum

Push-In Fitting Type Quick Exhaust Valve

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

HEP Series. Specifications. Switch specifications. Bearing parallel hand Double acting/single acting. Operational stroke length: 24, 36, 40, 50, 60mm

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

SMD2. Compact cylinder. Space saving structure 6, 10, 16 20, 25, 32. Simple square design. Switch integrated. Easy centering. Precise installation

and High precision guide provided High cylinder position accuracy, and wide guide realizes radial moment resistant high rigid structure.

Connector Series. Multiple Push-In Fitting Type. Desorption of Several Tubes at One Time. Combinable Connectors by Connector Band.

Double Power Cylinder. Non-rotating Double Power Cylinder. Series MGZ. Series MGZR (without MGJ MGP MGQ MGG MGC MGF MGZ MGT. non-rotating mechanism)

Transcription:

Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series CC-954A

Introducing the Free Position Locking Cylinder to the Flat Cylinder FCD Series! Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking mechanism If the piston rod is stationary, the cylinder can be locked at any position. Lock forward or backward. The lock s reverse direction is free, enabling caught workpieces, etc., to be removed easily. Simple space-saving design The flat shape enables installation in small spaces or in a row. Simple design fits in other devices, while providing position locking. Piston rod Lock metal When unlocked Lock Free When locked Intro 1 Nonrotating mechanism not required The cylinder is oval and prevents rotation, so no separate nonrotating mechanism is required. RoHS-Compatible All substances adversely affecting the environment, including lead and hexavalent chrome, have been eliminated.

Series variation Free position locking flat and compact cylinder UFCD Series : Standard : Option Option Variation Model no. Bore size (mm) Standard stroke length (mm) Min. stroke length Custom stroke length Max. stroke length Rod end male thread Switch Page 5 10 15 20 25 30 40 50 (mm) ( per ) mm (mm) N Double acting single rod type cushioned with switch UFCD-KL ø25, ø32, ø40, ø50, ø3 or equivalent 1 1 150 1 Intro 2

Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe warnings and precautions to ensure device safety. Check that device safety is ensured, and manufacture a safe device. WARNING 1 This product is designed and manufactured as a general industrial machine part. It must be handled by an operator having sufficient knowledge and experience in handling. 2 Use this product in accordance of specifications. This product must be used within its stated specifications. Do not attempt to modify or additionally machine the product. This product is intended for use as a general-purpose industrial device or part. It is not intended for use outdoors or for use under the following conditions or environment. (Note that this product can be used when CKD is consulted prior to use and the customer consents to CKD product specifications. The customer must provide safety measures to avoid risks in the event of problems.) 1 Use for special applications requiring safety including nuclear energy, railroad, aviation, ship, vehicle, medical equipment, equipment or applications coming into contact with beverage or food, amusement equipment, emergency shutoff circuits, press machine, brake circuits, or for safeguard. 2 Use for applications where life or assets could be adversely affected, and special safety measures are required. 3 Observe corporate standards and regulations, etc., related to the safety of device design and control, etc. ISO4414, JIS B8370 (pneumatic system rules) JFPS2008 (principles for pneumatic cylinder selection and use) Including High Pressure Gas Maintenance Law, Occupational Safety and Sanitation Laws, other safety rules, corporate standards and regulations, etc. 4 Do not handle, pipe, or remove devices before confirming safety. 1 Inspect and service the machine and devices after confirming safety of the entire system related to this product. 2 Note that there may be hot or charged sections even after operation is stopped. 3 When inspecting or servicing the device, turn off the energy source (air supply or water supply), and turn off power to the facility. Discharge any compressed air from the system, and pay enough attention to possible water leakage and leakage of electricity. 4 When starting or restarting a machine or device that incorporates pneumatic components, make sure that the system safety, such as pop-out prevention measures, is secured. 5 Observe warnings and cautions on the pages below to prevent accidents. The safety cautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section. DANGER: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries, or when there is a high degree of emergency to a warning. WARNING: When a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries. CAUTION: When a dangerous situation may occur if handling is mistaken leading to minor injuries or physical damage. Note that some items described as CAUTION may lead to serious results depending on the situation. In any case, important information that must be observed is explained. Intro 3 Disclaimer 1. CKD cannot be held liable for any business interruption, loss of profit, personal injury, delay cost, or any other ancillary or indirect loss, cost, or damage resulting from the use of or faults in the use of CKD products. 2. CKD cannot be held responsible for the following damage. 1 Damage resulting from disaster or failure of CKD parts due to fire from reasons not attributable to CKD, or by intentional or negligence of a third party or customer. 2 Damage that could have been avoided if customer equipment were provided with functions and structure, etc., generally accepted in the industry, when a CKD product is assembled into customer equipment. 3 Damage resulting from use exceeding the scope of specifications provided in CKD catalogs or instruction manuals, etc., or from actions not following precautions for installation, adjustment, or maintenance, etc. 4 Damage resulting from product modifications not approved by CKD, or from faults due to combination with other software or other connected devices.

Pneumatic components Safety precautions Always read this section before starting use. Refer to "Pneumatic Cylinders I (No. CB-29SA)" for the general cylinder or cylinder switch. Free position locking flat and compact cylinder UFCD Series Design & Selection WARNING This cylinder is a cylinder with a position locking (holding cylinder static state) mechanism. Life drops markedly if used for emergency stops (stopping while the cylinder is moving). If back pressure is applied to the locking mechanism, the lock may be released. Use a discrete valve, or use an individual exhaust type manifold. Do not apply torque to the rod in locked state because holding force drops and create a hazard. Use a mechanism that does not rotate the rod. To release the lock, when using forward locking, supply pressure to port B, and when using backward locking, supply pressure to port A. Check that load is not applied to the locking mechanism. When both ports A and B are exhausted and the piston is locked, if pressure is supplied to port A for forward locking or to port B for backward locking, the lock may not be released or, even if released, the piston rod may pop out and creating a hazard. CAUTION Basic circuit diagram Pipe the air piping for forward locking type as shown below. Faults such as a delayed response may result if piping other than that below is used, such as independent piping to the position locking mechanism. 1. As shown below, branch the piping to this cylinder at a position behind the valve, and pipe to the position locking section (connect main pipe to lock release port) and to the cylinder section (connect branched pipe to cylinder port). 2. If cylinder operation is faster than lock release, the lock may not be released or, even if released, the piston rod may pop out. This is hazardous, so design piping so that lock release is faster than cylinder operation. Forward locking type (Downward load) (Branched pipe) Forward locking type (Downward load) Backward locking type (Upward load) (Main pipe) Port A Port B Lock release port Port B (Lock release port) Port A Intro 4

UFCD Series Installation & Adjustment WARNING Do not apply grease to the piston rod because holding force drops and creates a hazard. Do not apply torque to the piston rod because holding force drops. CAUTION Main piping in the basic circuit diagram on the previous page should be thicker and shorter than branch piping. When attaching a load to male threads, fix the wrench hook at the end of the rod with a wrench. Apply load on the piston rod so that it is in the axial direction. Avoid applying rotation torque. Otherwise, use within the specified rotation torque range. Model no. Descriptions ø25 ø32 ø40 ø50 ø3 Allowable torque (N m) 1 1. 2.5 3.9 5.9 Avoid applying rotation torque with impact, or in ways that change the direction of the torque load instantly. When using several cylinders synchronized, install a separate guide. If only cylinders are used, synchronization is not possible, the rod twists, and operation becomes faulty. Fixing wrench When fixing onto female threads, fix the wrench hook at the end of the rod with a wrench using a standard tool (hexagon rod wrench), and tighten. Intro 5

During Use & Maintenance UFCD Series Precautions WARNING Do not lubricate the lock because holding force drops. How to unlock manually Do not disassemble the unit, since this may cause a hazardous situation. To prevent faults, use a dust cover during operation except when manually releasing brakes. Forward lock (lock direction ) Backward lock (lock direction ) If no air pressure is supplied in vertical mounting, etc., holding force may not be sufficient when the lock is manually released. This may cause the rod to move (drop) with the load's weight. For safety, take the following measures before manually releasing the lock: Move the load to the lowest end. Provide a stopper on the load. Supply air pressure to the cylinder and balance the load. When the cover is removed and a minus headed screw driver is inserted and titled lightly in the direction of arrow, the release lever rises, the lock is released, and the piston rod is freed. The cylinder may be damaged or may malfunction if a unit with excessive inertia, etc., is moved. Use within the allowable energy absorption range. CAUTION When locking the first time after leaving the lock released for a long time, a delayed response occur in the lock. Do not leave the lock pressurized, and operate the lock at each cylinder operation. (Use the basic circuit diagram shown on Intro 4.) If the cylinder is held while pressure is applied to the locking mechanism, the locking pin could dislocate and create a very hazardous situation. Do not use a 3-position closed center or 3-position P/A/B solenoid valve. Due to the structure, the piston rod drops by about 1 mm when the lock is applied. Intro

Free position locking flat and compact cylinder, double acting, single rod type UFCD Series Bore size: ø25, ø32, ø40, ø50, ø3 Specifications Descriptions UFCD-KL Bore size mm ø25 or equivalent ø32 or equivalent ø40 or equivalent ø50 or equivalent ø3 or equivalent Actuation Working fluid Double acting/cushioned Compressed air Max. working pressure MPa 0.7 Min. working pressure MPa 0.25 Withstanding pressure MPa 1.05 Ambient temperature C -10 to 0 (no freezing) Port size M5 Rc1/8 Rc1/4 Stroke tolerance mm + 0.5 (to 50) 0 Working piston speed mm/s 50 to 500 Cushion Lubrication Rubber cushion Not required (when lubricating, turbine oil Class 1 ISOVG32) Lock force N 345 543 904 1350 2220 Allowable energy absorption J 0.034 0.54 0.7 1.02 1.5 Non-rotating accuracy/allowable torque Descriptions ø25 or equivalent ø32 or equivalent ø40 or equivalent ø50 or equivalent ø3 or equivalent Revolvable angle tolerance Note 2 ±1 ±0.8 ±0.5 ±0.5 ±0.5 Allowable torque N m 1 1. 2.5 3.9 5.9 Note 1: Avoid applying rotation torque with impact, or in ways that change the direction of the torque load instantly. Note 2: "Nonrotating accuracy" is the value when a torque load equivalent to 10% of "tolerable rotation torque" is applied to the end of the piston rod. Stroke length Model no. Bore size (mm) Standard stroke length (mm) * Max. stroke length (mm) Min. stroke length (mm) ø25, ø32, 5, 10, 15, 20, 25, UFCD-KL ø40, ø0, 150 1 ø3 or equivalent 30, 40, 50 Note 1: Custom stroke length is available per 1mm increment. Note 2: Min. stroke length varies depending on installation method. Refer to the table below. Min. stroke length of type with switch With 1 piece With 2 pieces Rod end installation Head end installation Different surface installation Same surface installation 10mm 15mm 35mm (ø25, 32, 40, 50) 30mm (ø3) 1

Switch specifications Proximity switch Descriptions Applications M2V Proximity 2 wire M2WV (2 color indicator type) Programmable controller M3V Proximity 3 wire M3PV (Custom order) Programmable controller, relay, IC circuit, small solenoid valve UFCD Series Specifications M3WV (2 color indicator type) Output method - NPN output NPN output PNP output NPN output Power voltage - 4.5 to 28 VDC 10 to 28 VDC Load voltage 10 to 30 VDC 30 VDC or less Load current 5 to 30mA 200mA or less 100mA or less 150mA or less Light LED (ON lighting) Red/green LED (ON lighting) LED (ON lighting) Yellow LED (ON lighting) Red/green LED (ON lighting) Leakage current 1mA or less 10 A or less 0.05mA or less 10 A or less Reed switch Descriptions Reed 2 wire MOV M5V Applications Programmable controller, relay Programmable controller, relay, IC circuit (without indicator light), serial connection Load voltage 5 to 50mA with 12/24 VDC 50mA or less with 5/12/24 VDC Load current 7 to 20mA with 110 VAC 20mA with 110 VAC Light LED (ON lighting) Without indicator light Leakage current 0mA Note 1: Refer to "Pneumatic Cylinders I (No. CB-29SA)" about other switch specifications. 2

UFCD Series How to order UFCD-KL 25 10 F M2V R N A Model no. B Bore size C Port thread type D Stroke length Note on model no. selection Note 1: Refer to page 1 for the min. stroke of the cylinder with switch. E Lock direction F Switch model no. * indicates lead wire length. G Switch quantity H Option A Symbol Descriptions Model no. UFCD-KL Double acting/cushioned, with switch B Bore size (mm) 25 ø25 32 ø32 40 ø40 50 ø50 3 ø3 C Port thread type Blank Rc thread NN NPT thread (ø40 and over) (custom order) GN G thread (ø40 and over) (custom order) D Stroke length (mm) Bore size Stroke length Note 1 Custom stroke length ø25 to ø3 1 to 150 1 mm increment E Lock direction F Forward lock B Backward lock F Switch model no. Radial lead wire Contact Indicator Lead wire M2V* 1 color indicator type M2WV* 2 color indicator type 2-wire M3V* Proximity 1 color indicator type M3WV* 2 color indicator type 3-wire M3PV* 1 color indicator type (custom order) M0V* 1 color indicator type Reed M5V* Without indicator light 2-wire *Lead wire length Blank 1m (standard) 3 3m (option) 5 5m (option) G Switch quantity R One on rod end H One on head end D Two T Three H Option Blank Rod end female thread N Rod end male thread <Example of model number> UFCD-KL-25-10-F-M2V-R-N Model: Free position locking flat and compact cylinder A Model no. : Double acting/cushioned, with switch B Bore size : ø25mm C Port thread type : Rc thread D Stroke length : 10mm E Lock direction : Forward lock F Switch model no.: Proximity switch M2V, lead wire 1m G Switch quantity : One on rod end H Option : Rod end male thread 3

UFCD Series How to order How to order switch Switch body + mounting bracket Only switch body Mounting bracket FCS M2V SW M2V FCS M Switch model no. (item F on previous page) Switch model no. (item F on previous page) Bracket 4

UFCD Series Internal structure and parts list UFCD-KL-25, 32 Lock direction: F (forward lock) Lock direction: B (backward lock) 5 4 3 2 7 1 2 3 4 5 7 8 12 14 13 10 11 9 8 9 10 11 12 14 13 No. Parts name Material Remarks No. Parts name Material Remarks 1 Hexagon socket head cap bolt Alloy steel Blackening 8 Hexagon socket head cap bolt Alloy steel Blackening 2 Spring Steel Blackening 9 Rod cover Aluminum alloy 3 Pan head sems screw with cross-head socket Steel Trivalent chromate 10 Lock tube Aluminum alloy 4 Dust cover Stainless steel 11 Lock plate Special steel Trivalent chromate 5 Release piston Bronze casting 12 Rod packing seal Nitrile rubber Piston packing seal Nitrile rubber 13 Metal bush Oil-less metal 7 Gasket Nitrile rubber 14 Lock Nitrile rubber Black alumite UFCD-KL-40 to 3 Lock direction: F (forward lock) Lock direction: B (backward lock) 9 8 7 5 4 3 2 1 10 1 2 3 4 7 5 8 9 10 11 12 14 1 13 18 17 15 14 11 12 13 1 18 17 15 No. Parts name Material Remarks No. Parts name Material Remarks 1 F type: Hexagon socket head tapered screw plug Alloy steel 9 O ring Nitrile rubber B type: Hexagon socket head set screw Alloy steel 10 Gasket Nitrile rubber 2 Brake spring Steel Blackening 11 Hexagon socket head cap bolt Alloy steel 3 Dust cover Stainless steel 12 Rod cover Aluminum alloy 4 Piston ø40, ø50: bronze casting ø3: aluminum 13 Lock plate Special steel Trivalent chromate 14 Rod packing seal Nitrile rubber 5 Piston spring Steel 15 Metal bush Oil-less metal Pan head sems screw with cross-head socket Steel 1 Lock tube Aluminum alloy Hard alumite 7 Release piston tube Stainless steel 17 Rod packing seal Nitrile rubber 8 Piston packing seal Nitrile rubber 18 Lock Aluminum alloy Black alumite 5

Dimensions (ø25) UFCD Series Dimensions UFCD-KL-25-F (forward lock) Rod end male thread (option symbol N) 4.7 M5 depth 4 Lock release port 4.7 22 20 5 7.5 53.5 M5 depth 4 Return port M5 depth 4 Advance port 7.5 25 4-M5 depth 7 1 1 5.5 M10 x 1.25 Width across flats 17 Width across four sides (irregular positioning) 4-M5 penetrating M5 depth 9 10 24 38 55 ø12 Width across four sides 10 (irregular positioning) 2-M5 depth 7 7 (rod end) 7 (head end) 25.5 5 4 20.5 4 12 40 + stroke length 44 + stroke length 28 + stroke length 12 4 103 + stroke length UFCD-KL-25-B (backward lock) 4.7 M5 depth 4 Unlocked and return port 4.7 M5 plug 53.5 M5 depth 4 Advance port 7.5 25 4-M5 depth 7 1 1 5.5 Width across four sides (irregular positioning) M5 depth 9 4-M5 penetrating 10 24 38 55 ø12 2-M5 depth 7 7 (rod end) 7 (head end) 20.5 4 5 12 4 25.5 8 + stroke length 90 + stroke length 28 + stroke length 103 + stroke length 12 4

UFCD Series Dimensions (ø32) UFCD-KL-32-F (forward lock) Rod end male thread (option symbol N).2 M5 depth 4 Lock release port M5 depth 4 Advance port.2 22 20 8 7 13.5 3.5 M5 depth 4 Return port 7.5 28 4-M depth 8 M depth 11 2 1 5.5 M14 x 1.5 Width across four sides (irregular positioning) 4-M5 penetrating 14 30 45 5 ø1 Width across flats 22 Width across four sides 14 (irregular positioning) 2-M depth 8 8 (rod end) 8 (head end) 30.5 7 5 25.5 4 12 41 + stroke length 45 + stroke length 29 + stroke length 4 12 11 + stroke length UFCD-KL-32-B (backward lock) M5 depth 4 Unlocked and return port.2.2 M5 plug 54.5 M5 depth 4 Advance port 7.5 28 4-M depth 8 2 1 5.5 Width across four sides (irregular positioning) 4-M5 penetrating 14 30 45 5 M depth 11 ø1 2-M depth 8 8 (rod end) 8 (head end) 25.5 4 7 12 5 30.5 97 + stroke length 101 + stroke length 29 + stroke length 11 + stroke length 4 12 7

Dimensions (ø40) UFCD Series Dimensions UFCD-KL-40-F/B (forward lock/backward lock) Rod end male thread (option symbol N) 22 7 20 8 M14 x 1.5 Width across flats 22 Width across four sides 14 (irregular positioning) Rc1/8 F type: Return port B type: Unlocked and return port 7.5 7.5 Rc1/8 F type: Lock release port B type: Plug 8.5 9.5 Rc1/8 Advance port 8.5 32 4-M8 depth 10 2 2 5.5 8-ø9.5 spot face Depth 5.4 M8 depth 13 Width across four sides (irregular positioning) ø1 4-M penetrating 14 34 52 83 2-M8 depth 10 9 (rod end) 9 (head end) 7 8 8 15.5 45.5 1 15.5 10 + stroke length 110 + stroke length 30 + stroke length 130 + stroke length 8 15.5 8

UFCD Series Dimensions (ø50) UFCD-KL-50-F/B (forward lock/backward lock) Rod end male thread (option symbol N) 28 8 2 11 M18 x 1.5 Width across flats 27 Width across four sides 17 (irregular positioning) Rc1/8 F type: Return port B type: Unlocked and return port 9 9 Rc1/8 F type: Lock release port B type: Plug 10.5 85.5 Rc1/8 Advance port 10.5 39 4-M10 depth 12 2 3 8-ø11 spot face Depth.5 M8 depth 13 Width across four sides (irregular positioning) 17 40 2 101 5.5 ø20 4-M8 penetrating 2-M10 depth 12 10 (rod end) 10 (head end) 57.5 17.5 8 9.5 8.5 9.5 17.5 75 124 + stroke length 122 + stroke length 31 + stroke length 150.5 + stroke length 8.5 9.5 17.5 9

Dimensions (ø3) UFCD Series Dimensions UFCD-KL-3-F/B (forward lock/backward lock) Rod end male thread (option symbol N) 28 2 11 8 M18 x 1.5 Width across flats 27 Width across four sides 17 (irregular positioning) Rc1/4 F type: Return port B type: Unlocked and return port 10.5 10.5 Rc1/4 F type: Lock release port B type: Plug 11.5 95.5 Rc1/4 Advance port 11.5 49 4-M12 depth 15 2 7 5.5 8-ø17.5 spot face Depth 10.5 Width across four sides (irregular positioning) M10 depth 15 ø20 17 54 8 125 4-M12 penetrating 2-M12 depth 18 14 (rod end) 14 (head end) 8 10 9.5 21 3 84 21 141 + stroke length 35 + stroke length 170.5 + stroke length 21 10 10

11 M E M O

Related products UFCD Series Related products Position locking flat clamp cylinder CACF Series (custom order) A front crevice fitting has been installed on the UFCD Series. This space-saving clamp cylinder uses a narrow width. This cylinder is ideal for using several in a row or for installation in small spaces. Position locking compact cylinder USSD Series This space-saving cylinder is compact and thin, and the position locking section does not protrude. The position is locked at any position in the stroke, the same as for the UFCD Series. 12

2008.9.ACC