Fluid Flow Conditioning

Similar documents
FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

Fundamentals of Turbine Meters. Paul Honchar Sensus Metering Systems

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

ONICON Insertion Turbine Flow Meters Single Turbine vs. Dual Turbine Selection Criteria

Vortex Plate. Model VP General Specification. Product Features

FUNDAMENTALS OF GAS TURBINE METERS Paul Honchar Sr. Product Manager Sensus 805 Liberty Boulevard DuBois, PA, USA 15801

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

Fundamentals of Natural Gas Measurement

Model 8800C Vortex Installation Effects English Rev. CA

COMPRESSIBLE FLOW ANALYSIS IN A CLUTCH PISTON CHAMBER

Model FVP General Specification. Flanged Vortex Plate. Product Features

LIQUID MEASUREMENT STATION DESIGN Class No

BASICS OF ULTRASONIC FLOW METERS

Low Profile Insertion Vortex

The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture

DFX Series Liquid Ultrasonic Flow Meters

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.

AN INNOVATIVE APPROACH TO INCREASE DIAGNOSTIC SENSITIVITY IN ULTRASONIC FLOW METERS

Technical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects

Experiment No.3: Flow through orifice meter. Background and Theory

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

FLUID FLOW. Introduction

Rosemount 8800 Vortex Installation Effects

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Technical Data Sheet , Rev HA October Rosemount 8800 Vortex Installation Effects

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

Fundamental Training. Flow Con t

Experiment (4): Flow measurement

MODEL 1100 TURBINE FLOW METER

ORIFICE PLATE METER DIAGNOSTICS

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

VERIS FLOW MEASUREMENT GROUP

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

Hot Tap Insertion Vortex

Flow Measurement SITRANS F S Clamp-on

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

Applied Fluid Mechanics

Commercial/Industrial Ultrasonic Gas Meter Operation & Diagnostics Western Regional Gas Conference Bayview Ballroom 2 8/29/2017 9:00 9:45

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

Low-Cost Pipeline Flow Meter

11/12/2017 Erwin H. Doorenspleet

Heat Exchangers (Chapter 5)

ORIFICE PLATES, FLANGES FLOW NOZZLES, VENTURI TUBES AND ACCESSORIES

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

The use of CAD System for Improving Flow Conditioner Design to Reduce Installation Effects On Orifice Metering

The Effects of Pipewall Offsets on Water Meter Accuracy

Linear Shaft Motors in Parallel Applications

Model 1100 Turbine Flow Meter

Paddle-wheel flow controller with optical principle for On/Off control

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

FLUID CONTROL RESEARCH INSTITUTE

DY-LWGY Liquid turbine flow meter

Minimizing Noise. Marybeth G. Nored Dr. Klaus Brun Eugene Buddy Broerman Augusto Garcia Hernandez Dennis Tweten. Southwest Research Institute

Causes and Cures of Regulator Instability

flow measurement solutions RIM10 series rotor insertion flowmeters

Virtual Flow Bench Test of a Two Stroke Engine

Skip over navigation. Follow Flow Control Magazine On: facebook twitter youtube linkedin. Search Flow Control: Flow Control

Paddle-wheel flow controller for On/Off control

Permanent Multipath Clamp-On Transit Time Flow Meter

NUCLEAR POWER INDUSTRY

INSERTION flow sensor for continuous flow measurement

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

CFD ANALYSIS OF PRESSURE DROP CHARACTERISTICS OF BUTTERFLY AND DUAL PLATE CHECK VALVE

The Discussion of this exercise covers the following points:

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Impacts of Short Tube Orifice Flow and Geometrical Parameters on Flow Discharge Coefficient Characteristics

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

Model 1000 Vortex Meter

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

How You Benefit From The KC Sealing System A New Definition Of Leaky Flanged Joints Comparison Of Flanged Joint After Bolt-Up...

F-2600 SERIES INLINE VORTEX FLOW METER

Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

Hydraulic energy control, conductive part

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

Proving Liquid Ultrasonic Flowmeters Summary of Testing Conducted January 2011

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description

Lease Automatic Custody Transfer

FUNDAMENTALS OF VOLUME MEASUREMENT (TURBINE METERS) Tony Petitto. FMC Technologies Measurement Solutions, Inc.

Motional emf. as long as the velocity, field, and length are mutually perpendicular.

Single-phase Coolant Flow and Heat Transfer

Determination and Verification of the Forchheimer Coefficients for Ceramic Foam Filters Using COMSOL CFD Modelling

F-2700 SERIES INSERTION VORTEX FLOW METER

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Welker Gas Sampler Model MPS-2

The Shape of Things to Come

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

DEVELOPMENT OF A 3D MODEL OF TUBE BUNDLE OF VVER REACTOR STEAM GENERATOR

SENSOR MUT2300. Electromagnetic flowmeter. The electromagnetic flowmeter designed for the toughest applications DS401-1-USA

Transcription:

Fluid Flow Conditioning March 2014 Flow Conditioning There is no flow meter on the market that needs flow conditioning. All flow meters are effective without any type of flow conditioning. 1

Flow Conditioning Why do we want to use flow conditioners then? Can eliminate up to 80 90% of pipeline swirl. Restore flow profile symmetry and eliminate distortions. Isolates the flow meter from upstream disturbances. Allows much shorter meter runs to be used with much higher repeatability. Improves the benefits of many USM diagnostics by providing flow stabilty. Helps with noise or pulsation problems. Helps balance the pressure, velocity and flow rate of meter tubes running in parallel. They UNLOAD the flow meter, helping it become even more accurate. Flow Conditioning What if we have debris in our pipe? The debris has to go somewhere, ignoring the flow conditioner won t make it disappear. Install a filter (or another flow conditioner UPSTREAM of the meter run to catch the debris). Without something to catch debris, we risk damaging or destroying any sample probes, thermo wells or any other equipment in the pipe. Better hope there isn t a compressor or turbine downstream somewhere. If the gaskets are unraveling, recommend switching to Flexitallic CGI gaskets with an inner ring to keep the windings intact. 2

What is a Flow Conditioner? What is a Flow Conditioner? 3

What is a Flow Conditioner? What is a Flow Conditioner? 4

What is a Flow Conditioner? Why should we use a Flow Conditioner? When dealing with flow measurement, we cannot simply stick a flow meter in the pipe, turn it on and expect perfect results. In the real world, we have to deal with: Installation effects Swirl Flow profile distortion Pulsation Noise All of these combine in different ways to generate measurement errors! 5

Fully Developed Flow Fully developed pipeline flow is the ideal state of a fluid in a pipe. If we had an infinitely long pipe, this is the flow we would always see. It is mathematically predictable. It is perfectly symmetrical around the center of the pipe. It has no swirl. This *should* guarantee us perfect, error free, repeatable measurement. Installation effects take us away from this state. Fully Developed Flow 1.6 30000000 3000000 300000 30000 15000 10000 6000 1000 300 1.4 Normalized Flow Velocity (V/Vavg) 1.2 1 0.8 0.6 0.4 0.2 0 0 0.05 0.1 0.15 0.2 0.25 0.3 Distance Across Pipe (m) 6

Fully Developed Flow Swirl Swirl is the rotation of fluid in a pipe. It is caused by any change in piping direction! It can also be caused by any partial restriction of a pipe. 7

Swirl Swirl 8

Swirl Swirl 9

Swirl Swirl causes unpredictable distortions in the flow profile that change over time. Swirl flattens and then inverts flow profiles due to centripetal force. The harder the fluid is spinning, the more energy that is pushed to the pipe walls. Swirl can cause local effects due to the location of pressure taps (dp measurement) or in the case of Ultrasonic Meters (adding to or subtracting to local path velocity). Installation Effects Every pipe fitting generates an installation effect. Tees Elbows Expanders Reducers Valves Probes All of these objects can combine to create a deviation from perfect fully developed flow. 10

Installation Effects Elbows Installation Effects Tees 11

Installation Effects Tees Installation Effects Tees /w Turbulence 12

Installation Effects Probes Installation Effects Valves 13

Installation Effects Elbows & Orifice Plates Installation Effects Reducers 14

Measurement Errors The further we get from our perfect, swirl free, fully developed flow, the more uncertain our measurement becomes. Error due to flow profile distortion deviation from baseline state. Error due to swirl itself. What if we want to shorten our meter run? What do we do? Without Flow Conditioning 15

Flow Conditioning A properly designed Flow Conditioner converts this flow......into this. Flow Conditioning A properly designed Flow Conditioner converts this flow......into this. 16

Flow Conditioning 50.00 Empty 5&5 OIMLR137 25m 15000 Horizontal 2.5D Upstream Empty 5&5 OIMLR137 25m 15000 Horizontal 1D Upstream Empty 5&5 OIMLR137 25m 15000 Vertical 2.5D Upstream Empty 5&5 OIMLR137 25m 15000 Vertical 1D Upstream 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 6.00 4.00 2.00 0.00 2.00 4.00 6.00 Flow Conditioning 30.00 CPA50E 10&10 OIMLR137 25m 11500 Horizontal 5D Downstream CPA50E 10&10 OIMLR137 25m 11500 Horizontal 8D Downstream CPA50E 10&10 OIMLR137 25m 11500 Horizontal 15D Downstream CPA50E 10&10 OIMLR137 25m 11500 Vertical 5D Downstream CPA50E 10&10 OIMLR137 25m 11500 Vertical 8D Downstream CPA50E 10&10 OIMLR137 25m 11500 Vertical 15D Downstream 25.00 20.00 15.00 10.00 5.00 0.00 6.00 4.00 2.00 0.00 2.00 4.00 6.00 17

How They Work Hole pattern is arranged so that the resulting downstream condition is a fully developed profile, the same as would be achieved by a long length of straight, uniform pipe. Stream is forced towards the holes in the plate which forces the pressure field to balance immediately upstream of the flow conditioner. Fluid accelerates to over twice its initial velocity where the flow through each hole is roughly proportional to its area. If swirl is present, this is cut out by the acceleration of the gas, and the thickness of the plate. How They Work 1.2 1 0.8 Fluid Velocity (m/s) 0.6 0.4 0.2 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Distance Across Pipe (m) 5 FPS 25 FPS 75 fps 75 FPS. P=52000 Pa 75 FPS, Rough Wall 75 FPS, Smooth Wall 18

Meter Types All volumetric flow meters can be flow conditioned: Orifice, Ultrasonic, Venturi, Coriolis Vortex, Turbine, Cone, Mag, etc. Every meter type responds differently to the effects of swirl and flow profile distortion. Volumetric flow meters are looking for good flow. Flow with minimal swirl and good flow profiles. A flow conditioner is simply trying to improve the flow that the meter is seeing. CPA once said. It s far easier to measure good flow with a bad meter, than trying to measure bad flow with a good meter. 19

Ultrasonic Meters Rely on a noise pulse that is transmitted through the fluid and the flow rate is computed using the transit time. Transit time is affected by velocity disturbances within the pipe, slowing or speeding up the pulse. Multiple paths help to generate a complete picture of the cross sectional flow within the pipe. The meter only knows how long it took for the pulse to travel from point A to point B. It cannot guess the state of the flow along the way. CFD Ultrasonic Simulation SawchukSonic CFD Ultrasonic Flow Meter 7 path layout (every 1/8 pipe diameter). 45 degree path angle. Dual, redundant meters (14 paths total). Ability to switch paths on and off at will to show effect on final flow meter output. Path layout, angle and weighting has not been optimized for accuracy, reynolds number shifts or ability to handle installation effects. Meter is for demonstration purposes only. 20

Computational Fluid Dynamics (CFD) Computational Fluid Dynamics (CFD) 21

Computational Fluid Dynamics (CFD) Computational Fluid Dynamics (CFD) 22

Computational Fluid Dynamics (CFD) Computational Fluid Dynamics (CFD) 23

Computational Fluid Dynamics (CFD) Computational Fluid Dynamics (CFD) 24

Computational Fluid Dynamics (CFD) Computational Fluid Dynamics (CFD) 25

Computational Fluid Dynamics (CFD) OIML R137 Piping Dual elbows/bends out of plane (DBOOP) Half moon plate separating the elbows. Opening is towards the outside of the turn radius. Expander at the meter run inlet is no longer used; the elbows are the same pipe diameter as the flow meter. 26

OIML R137 Piping OIML R137 Piping 27

OIML R137 Piping OIML R137 Piping 28

OIML R137 Piping OIML R137, DBOOP & HMP, No FC 29

OIML R137, DBOOP & HMP, No FC OIML R137, DBOOP & HMP, No FC 30

OIML R137, DBOOP & HMP, No FC OIML R137, DBOOP & HMP, No FC 31

OIML R137, DBOOP & HMP, No FC OIML R137, DBOOP & HMP 32

OIML R137, DBOOP & HMP OIML R137, DBOOP & HMP 33

OIML R137, DBOOP & HMP, No FC, 10D Downstream OIML R137, DBOOP & HMP, CPA 55E, 10D Downstream 34

OIML R137, DBOOP & HMP, No FC OIML R137, DBOOP & HMP, No FC 35

OIML R137, DBOOP & HMP, No FC OIML R137, DBOOP & HMP, CPA 55E 36

OIML R137, DBOOP & HMP, CPA 55E OIML R137, DBOOP & HMP, CPA 55E 37

7 Path USM CFD Simulation, Flow Profiles No FC FC, CPA 55E 7 Path USM CFD Simulation, Swirl Profiles No FC FC, CPA 55E 38

7 Path USM CFD Simulation, USM Flow Profiles No FC FC, CPA 55E 7 Path USM CFD Simulation, USM Swirl No FC FC, CPA 55E 39

7 Path USM CFD Simulation, 2 Path Error No FC FC, CPA 55E No FC, 1.29% CPA 55E, 2.38% 7 Path USM CFD Simulation, 3 Path Error No FC FC, CPA 55E No FC, 3.29% CPA 55E, 0.37% 40

7 Path USM CFD Simulation, 4 Path Error No FC FC, CPA 55E No FC, 1.86% CPA 55E, 0.16% 7 Path USM CFD Simulation, 7 Path Error No FC FC, CPA 55E No FC, 0.41% CPA 55E, 0.07% 41

USM Results, No FC USM Results, CPA 55E 42

Ultrasonic Meters Since ultrasonic meters cannot actually determine what the transducer pulse is seeing, we want to guarantee the best flow profile possible. A flow conditioner helps ensure that this is possible. It helps creates a reference state so that no matter what the upstream conditions are, the ultrasonic meter is measuring a more predictable and repeatable flow profile shape. Deviations from this baseline result in errors that add to the complexity of calculating flow rate. Plate Based Isolating Flow Conditioners A properly designed flow conditioner is recommended for use in a range of Reynolds numbers. All fluid flows can improve from some sort of flow conditioning. While highly viscous flows are extremely resilient to swirl and flow profile distortions, the use of a flow conditioner quickly eliminates the remaining bulk rotation. What is the downside? How much pressure drop are we willing to spend? 43

Flow Conditioning Swirl Removal Flow Conditioning Swirl Removal 44

Pressure Drop All fittings, obstructions, even pipe itself has a k factor. The k factor is the pressure loss coefficient for a particular piece of piping. It is experimentally determined using the measured pressure drop. 2 P k V 2 K = Pressure loss coefficient. ΔP = Pressure drop across a section of pipe or a fitting. ρ = Bulk fluid density, kg/m 3. V = Bulk fluid velocity, m/s. Pressure Drop For natural gas applications, most plate flow conditioners have a K factor of approximately 2. Tube bundles are closer to 0.75 1.5. What if we are worried about the pressure drop across the flow conditioner? 45

Pressure Drop The CPA 50E K factor ~ 2.0 (dp same as roughly 277 feet of pipe, 12 ID). CPA 65E K factor ~ 1.0 (dp same as roughly 140 feet of pipe, 12 ID) Long radius Elbow K factor ~ 0.6 0.8 Tee, flowing straight through ~0.5 Tee, flow turning 90 degrees from inlet to outlet ~ 1.2 1.8 Flow from a inlet header into a meter run ~ 1.0 Flow from a meter run into an outlet header ~ 0.78 Pressure Drop The uni directional meter run on page 27 of AGA9, excluding the flow conditioner, will have a total K factor of at least 3.0 4.0. This is ignoring the fittings that would be needed to connect up to the tees. Adding two additional tees would nearly double the pressure drop. This is assuming fully developed flow. Swirl and profile distortion will change the pressure drop! 46

Pressure Drop Relative Pressure Drop 47

Pressure Drop Tube Bundle vs CPA 19 Tube Bundle CPA 50E/55E CPA 65E Wall Thickness (Inches) 0.125 0.25 0.298 Pipe Diameter (Inches) 11.938 11.938 11.938 11.938 11.938 Pipe Area (Inches^2) 111.932 111.932 111.932 111.932 111.938 Flow Area (Inches^2) 94.957 79.848 74.493 53.450 65.206 Porosity (%) 84.84% 71.34% 66.55% 47.75% 58.25% Surface Area The 19 Tube Bundle has multiple sets of fluid passages: 48

Surface Area Per unit length (1 ) the 19 Tube Bundle used has about 287 In 2 of wetted surface area. A plate flow conditioner such as the CPA 50E has 128 In 2 Surface Area it gets worse. Most plate flow conditioners have a thickness of 10 20% of the pipe diameter. In a 12 Schedule 40 pipe, a 19 Tube Bundle will have a length of twice the pipe NPS, giving a thickness of 25.5 inches, resulting in a overall wetted surface area of 7322 In 2. Roughly 34 times the surface area of a plate flow conditioner! 49

Pressure Drop Tube Bundle vs CPA Pressure Loss Coefficient vs Reynolds Number (Viscosity) 20.000 CPA 50E AGA 3 19-Tube Bundle 18.000 16.000 Pressure Loss Coefficient / K Factor 14.000 12.000 10.000 8.000 6.000 4.000 2.000 0.000 1 10 100 1,000 10,000 100,000 1,000,000 10,000,000 100,000,000 Reynolds Number Pressure Drop 50

Plate Based Isolating Flow Conditioners Total Life Cycle Costs (Capital + Operating + Compression) 3500 3000 2500 2000 1500 1000 500 0 Fuel Gas Driven (Compression Costs To Overcome Severe Pressure Drop) Optimal Flow Conditioner Porosity 0 10 20 30 40 50 60 70 80 90 100 Pipe Porosity or Pipe Open Area (%) Capital Cost Driven (Longer Meter Stations) Measurement Value Graph 51

Flow Conditioning Conclusion Can eliminate up to 80 90% of pipeline swirl. Help restore flow profile symmetry and eliminate distortions. Isolates the flow meter from upstream disturbances. Allows much shorter meter runs to be used with much higher repeatability. Are applicable for all liquid or gas flows! The flow conditioner is merely helping out the meter, providing higher reproducibility and lower uncertainty! Thank You For Further information www.flowconditioner.com www.cpacfd.com Danny Sawchuk danny@cpacl.ca 403.236.4480 52