XMC0 Series. Definite Purpose Contactors

Similar documents
XMC0 Series DEFINITE PURPOSE CONTACTORS

2. No tools required for snap-on accessories require that make modification quick and easy.

XMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

Cross reference. Definite Purpose Contactors

30C30 definite purpose contactor

Data Sheet Definite Purpose Contactors Ex9CK Series

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Micro Contactor MA Series

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Table of Contents. HCC Contactor Nomenclature

AF40... AF96 3-pole contactors Technical data

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Essential equipment for all your requirements

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

F-Series. Circuit Breaker

F-Series. Circuit Breaker

AF series contactors (9 2650)

Definite purpose contactors

Capacitor Switching Contactors Type K3...-A, K3...-K

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

YS Series Contactors YS1N- F11 ****

General Purpose Relays Industrial Relays. Power Relay RM 2/3/7

Installation Contactors RIC, RAC

Features and benefits. Normally open, normally closed contact logic

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF series contactors (9 2650)

Application Description

UEW5 series intelligent air circuit breaker

Manual Motor Starters. Meta-MEC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Miniature Circuit Breakers

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1

ASL09..S 3-pole Contactors - Spring Terminals

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Description. Positive safety relays

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Series KTU7 UL489 Molded Case Circuit Breakers

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Definite Purpose Contactors and Starters

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Enclosed Full-Voltage Starters

Bulletin 190-M Compact Starters. Selection Guide

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Enclosures. See Section Typical Description

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE

Product Description. Application Description

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

Thermal Overload Relays - WEG RW Series, 2 Pole

Mini contactors B6, BC6 with 3 pole

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

3. Coils shall be of molded construction

JARD by MARS JARD by MARS

JOSLYN CLARK VACUUM CONTACTORS

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

DPX Magnetic only

Thermal Overload Relays

B Mini Contactor V Hz

Definite Purpose Contactors and Starters

Series KTU7 UL489 Molded Case Circuit Breakers

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

W Datasheet: DIN Rail Contactors, series AMPARO

General Purpose Relays Power Relays. T9G series, DC coil 30A PCB Relay

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Industrial Contactors CTX 3 3P 185A - 800A

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Features. Type List A

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

4.1. Definite Purpose Contactors and Starters. Contents

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Features. Type List 832A

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

Enclosed Full-Voltage Starters

Bussmann series Quik-Spec Power Module Switch elevator disconnect

DPX earth leakage DPX 3 -I earth leakage

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

High Current Solutions High Current Devices

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Thermal Overcurrent Circuit Breaker 3120-F...

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Switches Unlimited Phone: * Fax:

Thermal-magnetic Miniature Circuit Breaker 4230-T...

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Thermal Overcurrent Circuit Breaker 3120-F...

T75S5D Product Details

PD-Series Ground Fault Circuit Protection

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Motor Protection Circuit Breakers

Transcription:

Description American Zettler XMC0 series of are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are found in refrigeration, air conditioning and heating. Other applications include elevators, food service equipment, cranes, hoists, welding machines, power supplies, vending machines, lighting, pumps and compressors. XMC0 contactors are built to the ARI 780/790 standard in our ISO 9001 manufacturing facility for high performance and great reliability. XMC0 is available in various pole configurations and load ratings up to 90 amps. Features A variety of termination options for specific application requirements Universal mounting plate: Easy replacement of competitor's contactors Heavy-duty contacts ensure long electrical life EE lamination (magnetic assembly) provides optimum performance while reducing power consumption Performance unaffected by position mounting Dust-free internal construction UL, CUR file no. E222994

PART NUMBERING SYSTEM Full Load Amps Number of Poles Coil Voltage Mounting Plate Cover Terminal Contact Material Aux Switch Block Left Aux Switch Block Right Coil Terminals Power Q.C. Terminals Custom Special Code Full Load Amp 25 25 FLA 32 32 FLA 40 40 FLA 50 50 FLA 63 63 FLA 75 75 FLA 90 90 FLA Number of Poles 1 1-pole + 1 shunt - Compact 2 2-pole - Compact 7 1-pole - Compact 3 3-pole* - Standard 3A 2-pole - Standard * 3P is only option for 50/63/75/90 Amp models D 12V 12V E 24V 24V F 110-120V 110-120V I 208-220V 208-240V L 277V N 380-415 440-480V U 550-600V 550-600V XMC0 Mounting Plate A B C Cover A B A Screw - 50 3 B B B C - H 0 0 F G - XXXX Plastic Base Metal Plate Metal Plate with DIN rail mounting* * Available for 50 &63 Amp versions only Terminal with Quick Connects B Sems clamp C Slotted & Hex head washer D Box lug Box lug (Line) Slotted & E Hex head washer Slotted & Hex head F washer (Line) Box lug Nil H Long cover Short cover Contact Material AgSnO2 AgCdO *Contact option available in 40A version only. All other amperages use AgCdO Auxiliary Contact Options ( Right and Left) 0 1 3 4 5 6 1P 3P 4P 5P 6P None ( standard type) 1NC+1NO, pressure plate screws w/ Q.C. 1NC,pressure plate screws w/ Q.C. 1NO, pressure plate screws w/ Q.C. 2NC, pressure plate screws w/ Q.C. 2NO, pressure plate screws w/ Q.C. 1NC+1NO, pressure plate screws 1NC, pressure plate scerws 1NO, pressure plate screws 2NC, pressure plate screws 2NO, pressure plate screws Coil Terminals Dual Terminals w/o screws in 1 & 2 pole Nil and single terminals w/ screw in 3 pole F Dual Terminals w/ screws in 3 pole Power Terminals Nil G D Q Quad Terminals 1&2 poles Dual Terminals 3 pole Without any terminals Dual terminals in 1&2 poles Dual terminals at the side near coil terminal and quad terminals on opposite side in 3 pole

General Data Rated insulation voltage 690 Vrms Di-electric strength 2500Vrms (coil to contact & contact to contact) Designs/conforms to IEC 60947-4-1, GB14048.4, EN60947-4, ARI780 / 790 Agency approvals UL,CUR file E220475 Operating position Vertical and Horizontal mounting recommended Operating altitude 2000 meters without derating -20 C to 70 C Ambient temperature -40 C to 70 C Shock resistance Contact Open: 6g ; Contact Closed: 15g (1/2 ~ wave) = 11ms Vibration resistance (5-300Hz) Contact Open: 2g ; Contact Closed: 4g Weight 20-40A: 230-420g, 50/63A: 650g, 75/90A: 1550g Torque Screws 25 lb-in/lugs 25 lb-in for 20-40FLA types Screws 45 lb-in/lugs 50 lb-in for 50-63FLA types Screws 50 lb-in/lugs 60 lb-in for 75-90FLA types Screws 8 lb-in for Auxiliary Contact Blocks Coil Screws 8 lb-in for 3-pole 30-40FLA and 12 lb-in for 50-90FLA types Main Screws 12 lb-in/auxiliary Screws 8 lb-in/ Coil Screws 8 lb-in for small frame types The female connector should meet IEC 60760, necessary QC Wiring to ensure the reliability of connection between female connectors and QC terminals Electrical Rated Operating voltage 12V-600V max. Make capacity (230V, cos Ø=0.45) 12 x FLA Break capacity (230V, cos Ø=0.45) 10 x FLA Switching frequency 360 operations/hour Electrical endurance (ARI 780/790) 250,000 cycles Mechanical endurance (ARI 780/790) 3,000,000 cycles Auxiliary Contact Block Data Conventional thermal current ( A) Rated Insulation Voltage ( V ) Rated Operational Current (A) 10 690 AC600 (AC-15) 230/380V 3/1.9 N600(DC-13) 110/230V 2.2/1.1

Electrical Ratings Size Compact Standard Full Load Amps (FLA) Resistive Load Amps (RLA) 25 32 150 240VAC 480VAC 600VAC 125 100 32 40 180 150 120 40 50 240 200 160 25 32 150 125 100 32 40 180 40 50 240 50 63 300 Locked Rotor Amps (LRA) 150 120 200 160 Pole Form Order Number 1P XMC0-257 1P+1shunt XMC0-251 2P XMC0-252 1P XMC0-327 1P+1shunt XMC0-321 2P XMC0-322 1P XMC0-407 1P+1shunt XMC0-401 2P XMC0-402 2P XMC0-253A 3P XMC0-253 2P XMC0-323A 3P XMC0-323 2P XMC0-403A 3P XMC0-403 250 200 3P XMC0-503 63 80 360 300 240 3P XMC0-633 75 95 450 375 300 3P XMC0-753 90 120 540 450 360 3P XMC0-903 Coil Data Pole Form Inrush Sealed Sealed VA VA (W) 1 pole, 1 pole + 1 shunt 32 5.0 1.5-3 2 pole 40 6.0 2.5-4.5 3 pole, 2 pole standard (3A) 60 8.0 3.6-6 3 pole -503 & 633 120 17.0 3.5-8 3 pole -753 & 903 235 32.0 6.0-17 *Us = nominal coil voltage Pickup Voltage Dropout Voltage < Â Us Us* Ã > 0.2 0.2 Us* Us

Dimensions 81 4147 41 50 59.8 Fig 1-1-pole/1-pole +shunt 2 pole (plastic base, 25-40 A Compact) 27 16 38 45 81 41 50 59.5 Fig 2-1-pole/1-pole +shunt 2 pole (metal base, 25-40 A Compact)

41 50 0.12 61 38 45 0.12 0.12 Fig 3-2-pole (metal base, 25-40 A Compact) 16 3 pole plastic base (standard version) 16 +0.4-0.1 +0.13-0.03 1 47 81.9 96 0.3 0.5 5.3 +0.20 35+0.50 38 0.2 50.4 0.2 61 0.3 81.5 0.5 Fig 4-3-pole (plastic base, 25-40 A Standard)

81.9 ± 0.3 XMC0 Series 3 pole plastic base (standard version) 16 16 1 47 96 ± 0.5 35 ± 0.50 5.3 ± 0.20 38 ± 0.2 50.4 ± 0.2 61 ± 0.3 81.5 ± 0.5 Fig 5-3-pole (plastic base, 25-40 A Standard) 10 50 0.1 92.5 82 0.2 79.5 0.2 61 78 Fig 6-3-pole (metal base, 25-40 A Standard) 10 38 0.195 50.4 0.23

127 ± 0.4 102.6 ± 0.4 80 ± 0.3 112.5 ± 0.4 117.5 ± 0.4 XMCO Series ± 0.2 82.5 ± 0.3 84 ± 0.5 83 ± 0.5 38 ± 0.2 57 ± 0.2 73 ± 0.3 Fig 7-3-pole (metal base, 50-63 A Standard) 94 ± 0.4 112 ± 0.4 63 ± 0.3 73 ± 0.3 Fig 8-3-pole (metal base, 75-90 A Standard)

XMCO Series 63.8 61 71 1 6.4