Leak testing in the automotive industry. Applications for Component Manufacturing and Final Testing

Similar documents
TSHR 6000 series TN/TS/TX analyzer

1 of 12 10/5/2015 8:11 AM

Cooling System Description and Operation

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H4DOTC

RELIABLE AND EFFICIENT SYSTEMS

The new range of service stations for vehicle A/C systems. Alaska START Alaska START HFO Alaska BUS Alaska PREMIUM Alaska PREMIUM HFO

2013 Kia Optima L4-2.0L Turbo

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H6DO

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

EMISSION CONTROL (AUX. EMISSION CONTROL DEVICES) H4SO

Hot Runner Solutions for Technical Moulding. An Introduction to Mastip Technology.

TSHR 7000 series TN-TS-TX analyzer

MOBILAIR M 114. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 9.7 m³/min ( cfm)

The reliable choice for the Oil and Gas industries

How innovative valve technology can improve cooling of die casting processes

Varian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7

MANUAL CONTROL / SEMIAUTO TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Ram Cushions and Pressure Parallels Dynamic Solutions For A Global Market

2006 Ford Pickup F350 Super Duty

Drive and Motion Systems for Compactors

Agricultural Drive and Motion Systems

Liquid Gas Transport and Storage Reciprocating Compressors for Low Temperature Gases Down to Minus 170 C

Engine Emission Control 6.7L Diesel

AVL Media Conditioning Systems

EVAP system, servicing

Fuel and exhaust systems 4A 21

7. Evaporative Emission Control System

next TURBOMOLECULAR PUMPS

Cetane ID 510. Customer Presentation. Refining. Petrochemical

Combustion process Emission cleaning Fuel distribution Glow plugs Injectors Low and high pressure pumps

DIM Heating and Air Conditioning

Statim G4 Error Codes

INNOVATIVE RADIOTRACER TECHNIQUES APPLIED TO THE DEVELOPMENT OF ENGINES AND LUBRICANTS

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

1991 TOYOTA Electrical Components MR2. evaporator. compartment. ARTICLE BEGINNING BUZZERS, RELAYS & TIMERS

MOBILAIR M 122/M 123. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 7.3 to 11.4 m³/min ( cfm)

Range of KONFORT stations

CHAPTER 12 SERVICING. Section Title Page

Intake and Exhaust System, Design and Function

Acura Plus Comprehensive & Major Component Coverage

KONFORT 744 for CO2. Mercedes-Benz. KONFORT 744 is approved and recommended by:

Diagnostic Trouble Codes (continued) SAE Defined Codes

MOBILAIR M 200. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 14.5 to 21.2 m³/min ( cfm)

THE NEW EXPERIENCE IN TURBOPUMPS

MOBILAIR M 135/M 170/M 171. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 10.5 to 17.0 m³/min ( cfm) COMPRESSORS

IN-VEHICLE SERVICING > VALVE COVER - RH

AVL Particle Measurement System Aviation

Appendix A. Standard Symbols for Hydraulic Components

breakthrough versatility

CASE STUDY APPLICATIONS OF THE DC300

Gemini MxG50x BENEFITS. Long lifetime in harsh environments

FACT SHEET 12 Mobile air-conditioning

Brevini Evolution Series Winches. The new BWE Series for mobile and industrial markets.

Section 10 Chapter 7

Drained coolant must be stored in a clean container for disposal or reuse.

2014 Buick Encore. Fig. 2: Replacing Measured Compressor Oil Courtesy of GENERAL MOTORS COMPANY

EPA 2016 PACCAR MX-11 Engine. Month XX, 20XX

LEXUS EXTRA CARE GOLD. VEHICLE SERVICE AGREEMENT offered by LEXUS FINANCIAL SERVICES

1997 Volvo 850 GLT. Fig. 2: Removing Drive Shaft, Engine Mount Bolt & Torque Arm (5-Cylinder) Courtesy of VOLVO CARS OF NORTH AMERICA.

MSG TURBO-AIR API. API 672 Centrifugal Air Compressor Packages Efficient, reliable, 100% oil-free air* *Per ISO certification

4.0L CEC SYSTEM Jeep Cherokee DESCRIPTION OPERATION FUEL CONTROL DATA SENSORS & SWITCHES

System Solutions For. Marine Applications. Parker On Board, Around the World

As diesel fuel ages it degrades in 2 ways: particulate formation, and biological growth.

ITT Industrial Products

- Rugged - Durable - Reliable - Versatile

Engine seals. The Power of Knowledge Engineering

THE FKFS 0D/1D-SIMULATION. Concepts studies, engineering services and consulting

FAG Active Magnetic Bearing

Brief Overview 2018 WEH CONNECTOR SOLUTIONS for pressure-tight connections in seconds WEH Q UA LIT Y. since 1973

Recirculating Coolers

MOBILAIR M 114. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 7.5 to 9.7 m³/min ( cfm)

TURBOVAC ix Turbomolecular Pumps 90 l/s l/s

measure. analyze. innovate.

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

Lubrication & Cooling Systems

IMPORTANT: Hoses touching the frame, body, or engine may cause system noise. Verify that the hoses do not touch any other part of the vehicle.

ENGINE AND EMISSION CONTROL

Introducing R744 charging solutions. Featuring ECO 2 MASTER Technology

Vacuum Furnace Pumping Systems

Applications. Compressor-Features The Vilter Advantages. LNG Boil Off Gas Gathering BIO - Gas Digester CO 2 Nitrogen Hydrogen Refrigerant

Component and System Level Modeling of a Two-Phase Cryogenic Propulsion System for Aerospace Applications

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

2014 RAM C/V Tradesman

Knowledge of diagnosis and rectification of light vehicle engine faults

Knowledge of Diagnosis and Rectification of Light Vehicle Engine Faults

Diagnosis of fuel tank systems with fuel tank leak diagnosis module (DMTL)

ENGINE 6G74 3.5L-SOHC-24 VALVE

Climatic Wind Tunnel in Decatur Illinois Replicates Extreme Conditions

Graco PD44. Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing

Integrated PowerStation. Advanced Power Solution for Reactor 2

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

Advanced High-Tech Solutions for Coil Winding Process Control

THE MOST ADVANCED COMPRESSOR TECHNOLOGY AVAILABLE A WORLD OF COMPRESSORS FOR A WORLD OF DIFFERENCE

Engine Compartment Inspection

High efficiency compressed air filtration & water separation

SKF sealing solutions for off-highway machines Protecting productivity and profitability at jobsites worldwide


Product Range A-201-2

Installation Instructions HD Performance Turbo Control Valve Focus ST225 model Focus RS model

Sullair: An Industry Leader

Transcription:

Leak testing in the automotive industry Applications for Component Manufacturing and Final Testing

LEAK TESTING METHODS INFICON offers a wide variety of leak detection options for the various leak testing methods available in the manufacturing of automotive components and sub-assemblies. INFICON is the ideal supplier for your leak detection needs Dependable, accurate measurements High repeatability and reproducibility Extremely reliable leak detectors offering low cost of ownership Vacuum leak detection Leak detectors for helium, hydrogen and final medium e.g. refrigerants, natural gas, fuel, etc. Leak detection as well as easy leak location Easy to operate Typical Applications Quality Assurance of components, sub-assemblies in component production and final assembly, as well as for rework loops Leak testing in garages and service centers Accumulation leak detection About INFICON INFICON is a global provider of innovative instrumentation, critical sensor technologies and advanced process control software used for leak detection in air conditioning, refrigeration, and automotive manufacturing. INFICON employs approximately 950 people worldwide, including more than 350 in North America. INFICON technologies set quality-control standards for leak detection at automotive manufacturing facilities around the globe. Innovative INFICON helium, hydrogen and refrigerant gas leak detectors are used for checking a variety of components and subassemblies. Auto makers and their suppliers utilize INFICON products to ensure quality throughout their manufacturing and assembly operations. Sniffer leak detection Comparison of bubble testing to detectable leak rates Grafik Nachweisgrenzen im Wasserbad LEAK RATE IN MBAR*L/S = ATM*CC/SEC

Reliable, accurate tools for any of your leak detection tasks Components testing: Drive train, Oil and Water Circuit alternative drive technologies Engine block Engine head Transmission Torque converter Charge-air intercooler Plastic oil tank Oil cooler Oil pan 10-1 - 10-2 (1-12) 10-1 - 10-2 (2-12) 10-1...1 (5... 100) Protec 10-3 - 10-4 ~ 10-3 ~ 10-3 10-2...10-4 ~ 10-2 Modul1000 LDS3000 LDS3000 LDS3000 Oil pump 10-2... 10-1 (1... 10) Modul1000 Coolant expansion tank 10-2... 10-1 (1... 10) Water cooler Water pump E-car battery E-car battery cooling hoses ~ 10-2 10-2... 10-1 (2... 15) ~ 10-1 (4-10) Modul1000 Protec LDS3000 LDS3000 Protec LDS3000 Natural gas engine Hydrogen fuel tank 10-4 - 10-5 10-4 - 10-5 10-4 - 10-5 Protec Protec

Components testing: Fuel systems, Safety features and more Fuel tank Tank filler neck Tank filler cap Fuel tank sending unit Swirl pot (Diesel) Fuel injector Fuel pump High pressure fuel rails 10-4 - 10-6 ~ 10-4 ~ 10-4 ~ 10-4 10-2 - 10-4 10-4 - 10-5 10-4 10-4 - 10-6 Modul1000 LDS3000 LDS3000 Protec LDS3000 Fuel lines Diesel fuel filter Wheels Shock absorber Brake hoses Seat belt pretensioner Airbag ignitor caps Airbag generator 10-4 - 10-6 10-4 - 10-6 ~ 10-4 ~ 10-4 10-3 - 10-4 10-3 - 10-4 ~ 10-4 Cold gas: ~ 10-4 Hot gas: 10-3 - 10-4 Modul1000 Modul1000 Modul1000 Modul1000 Modul1000 LDS3000 LDS3000 LDS3000 LDS3000 LDS3000

leak detection expertise from a single source! Components Testing: AC Systems, Various Final Assembly testing: AC system, engine, E-drive Power steering housing Servo oil reservoir Windshield wiper fluid can Starter battery Brake fluid reservoir Power brake booster Vacuum brake pump AC hoses AC compressor 10-2 - 10-4 10-2 - 10-4 ~ 10-2 ~ 10-3 10-3 - 10-4 10-3 - 10-4 ~ 10-1 (5-20) 10-4 - 10-5 10-4 - 10-5 LDS3000 Modul1000 AC evaporator AC condenser AC filling valve Typical leak rates (mbar l/s) Expansion valve Air conditioning systems 10-4 - 10-5 10-4 - 10-5 10-4 - 10-5 10-4 - 10-5 5 g/a refrigerant per joint Engine oil circuit Engine water circuit Engine fuel circuit Cooling circuit E-battery ~ 10-1 (~ 10) HLD6000 ~ 10-1 (~ 10) LDS3000 LDS3000 LDS3000 LDS3000 Ecotec E3000 Protec 10-3 - 10-5 5 g/a refrigerant per joint Modul1000 Modul1000 Modul1000 Modul1000 Ecotec E3000 HLD6000 Ecotec E3000 Final Assembly

A wide range of leak detection products for your automotive application PROTEC HELIUM Protec is specifically designed for full-time sniffing applications in industrial production environments. Its patented Wise Technology sensor offers highest availability and low cost of ownership. Protec P3000XL is designed to prevent operator errors and allows the operator to detect leaks in even difficult to reach locations. It is ideal for detecting gaseous leaks. SENSISTOR HYDROGEN is a leak detector for automatic and accumulation systems. The use of a low cost forming gas (5% hydrogen in 95% nitrogen) makes it a l ow cost solution for many applications. The is ideal for finding very small leaks that would allow leaking of liquids such as water, liquid fuel or oils. Leak Detector is a dedicated leak sniffer offering leak locating in a variety of situations, both on the production and repair lines. High selectivity, wide dynamic range and short recovery time make this detector highly adaptable. The - which uses 5% hydrogen in 95% nitrogen as tracer gas - excels in finding fluid leaks and is sensitive enough for finding gas leaks. ECOTEC E3000 MULTI-GAS Ecotec E3000 allows the operator to detect leaks by sniffing for the escape of a final medium like fuel or refrigerant. The unit can detect four gases selectively at any time. Ecotec E3000 is designed to minimize operator error and to maximize reliability of testing. LDS3000 HELIUM AND HYDROGEN LDS3000 is a modular leak detector used in integrated leak detection chamber systems. Its compact design and variety of interfaces and protocols allows for easy integration into automated testing systems. An optional touch screen display enables easy operation. MODUL1000 HELIUM Modul1000 is a plug and play leak detector for universal integration into industrial leak testing systems (vacuum or sniffer mode). With flexible vacuum architecture, the Modul1000 provides the adaptability to accommodate changes in production specifications. T-GUARD LEAK DETECTION SENSOR is a leak detection sensor for use in integral leak testing of components. Through the use of the patented Wise Technology sensor can be used in leak testing chamber systems without the need for vacuum. It offers the sensitivity of helium leak testing at the price of pressure decay systems, and is ideal for testing warm, wet or dirty parts. Service S D-TEK Select, Compass and TEK-Mate are refrigerant leak detectors for vehicle air conditioning service. The Whisper ultrasonic leak detector is a versatile tool useful in detecting leaks of any gas under pressure or vacuum, diagnosing solenoid operations and detecting worn pistons and bearings. Service leak detectors are battery operated tools, designed to maximize productivity on the job site. HLD6000 REFRIGERANT HLD6000 is a sniffer leak detector for testing air conditioning assemblies. It is available for hydrocarbons as well as for CO 2. Its dual inlet technology guarantees high reliability and repeatability of results, even in environments with an increased concentration of refrigerant. www.inficon.com reachus@inficon.com Due to our continuing program of product improvements, specifications are subject to change without notice. miba00e1-b (1407) 2014 INFICON