Valves. Double stage and modulant motorized butterfly valves MRBV & MRBV-CMAP (E1302 rev /04/2011)

Similar documents
Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Burners. Pilot Heads BTC & BTSA (E3121 rev /04/2018)

Orifice Flow Meters POP-S (E5720 rev /03/2013)

Valves. Slow opening and rapid closing solenoid valves VM-L (E1111 rev /11/2012)

Burners. Pilot Heads BTC & BTSA (E3121 rev /09/2010)

Burners. Ribbon linear flame burners AB & ABM (E3010 rev /11/2017)

Burners. Metallic free flame burners. EMB (E3004 rev /02/2010)

Free flame burners EMB (E3004 rev /02/2015)

Burners. Self-recuperative burners high speed with flat flame REKO-SIK-SW (E3903 rev /06/2015)

Burners. High velocity LOW NOx combustion air burners EMB-SIK-NxT (E3507 rev /11/2016)

Radiant tube burners RT (E3900 rev /01/2018)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-S (E7021 rev /05/2015)

OIL REGULATORS RFG SERIES FEATURES APPLICATIONS DESCRIPTION INSTALLATION. Bulletin E5301 rev03 02/04/03. Body and valve seat: Shutter seat:

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901FF rev /05/2009)

Electronics. Permanent operation microprocessor burner control device ESA GENIO-PRS (E7022 rev /05/2015)

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

RS/M SERIES. Modulating Gas Burners FIRING RATES

PNEUMATIC PUMP Series

Electronics. Permanent Operation Microprocessor Burner Control ESA ESTRO-PO (E7014PO rev /05/2013)

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

VALVES WITH NA ELECTRIC ACTUATOR

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Powers TM Controls EA 338 Electronic Actuator

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Automatic concealed bollards 275 H600 and 275 H800 Control station

Actuators for air dampers and control valves of oil burners

VE4000 & VE5000 SERIES

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Flow Meter Terminal Boxes

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

VALVES WITH SA ELECTRIC ACTUATOR

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

Electromotoric Actuators

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Combi valves PN 16 with flanged connections

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

Actuators for air dampers and control valves of oil burners

Solenoid Valve DF-SA-series

BELT CONVEYOR CB/M5 Series

Automatic concealed bollards 275 H600 and 275 H800 with pit

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Q u a r t e r T u r n E l e c t r i c A c t u a t o r s

Electromotoric actuators

Modulating control valves with magnetic actuators, PN 16

2- and 3-port valves with flanged connections, PN 16

Electromotoric Actuators

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

2-port seat valves PN16 with flanged connection

VG6000 Series Forged Brass Valves

Solenoid Valve ST-SA-series

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Troubleshooting Bosch Proportional Valves

MA-5200 Series MA-5300 Series

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Motorized Butterfly Valve

BOAX-B Mat E. Type Series Booklet

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

Sentry Battery Charger. Installation and Operations Manual Section 75

2- and 3-port valves with flanged connections, PN 16

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

SERIES 2000 GAS SAFETY SHUT OFF VALVE

SAX Electronic Valve Actuator

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Solenoid Valve DF-SB-series

Actuators for air dampers and control valves of oil burners

INSTALLATION INSTRUCTIONS

Motorized Butterfly Valve

VALIADIS S.A. HELLENIC MOTORS

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

SG-B1 SERIES / SG-A1 SERIES

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

A44 W0...W2: Motorised actuator

US - UP2/OIL 12V US - UP2/OIL 24V

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Modulating control valve PN16 with magnetic actuator

Electromotoric Actuators

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

ATTENTION: Industrial machinery for professional use. These instructions are for qualified personnel USE AND MAINTENANCE MANUAL

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

2-port ball valves with flanged connection, PN25

Modulating control valves with magnetic actuators, PN 16

Transcription:

Valves Double stage and modulant motorized butterfly valves MRBV & MRBV-CMAP (E1302 rev. 04-07/04/2011)

GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting the norms present at the time and place of the installation. ¾ To avoid damage to people and things, it is essential to observe all the points indicated in this handbook. The reported indications do not exonerate the Client/User from observing general or specific laws concerning accidents and environmental safeguarding. ¾ The operator must wear proper DPI clothing (shoes, helmets...) and respect the general safety, prevention and precaution norms. ¾ To avoid the risks of burns or high voltage electrocution, the operator must avoid all contact with the burner and its control devices during the ignition phase and while it is running at high temperatures. ¾ All ordinary and extraordinary maintenance must be performed when the system is stopped. ¾ To assure correct and safe use of the combustion plant, it is of extreme importance that the contents of this document be brought to the attention of and be meticulously observed by all personnel in charge of controlling and working the devices. ¾ The functioning of a combustion plant can be dangerous and cause injuries to persons or damage to equipment. Every burner must be provided with certified combustion safety and supervision devices. ¾ The burner must be installed correctly to prevent any type of accidental/undesired heat transmission from the flame to the operator or the equipment. ¾ The performances indicated in this technical document regarding the range of products are a result of experimental tests carried out at ESA-PYRONICS. The tests have been performed using ignition systems, flame detectors and supervisors developed by ESA-PYRO- NICS. The respect of the above mentioned functioning conditions cannot be guaranteed if equipment, which is not present in the ESA-PYRONICS catalogue, is used. To dispose of the product, abide by the local legislations regarding it. GENERAL NOTES: ¾ In accordance to the internal policy of constant quality improvement, ESA-PYRONICS reserves the right to modify the technical characteristics of the present document at any time and without warning. ¾ It is possible to download technical sheets which have been updated to the latest revision from the www.esapyronics.com website. ¾ The products manufactured by ESA-PYRONICS have been created in conformity to the UNI EN 746-2:2010 Norms: Equipment for industrial thermal process - Part 2: Safety requirements for combustion and the movement and treatment of combustible elements. This norm is in harmony with the Machine Directive 2006/42/CE. It is certified that the products in question respect all the requirements prescribed by the above mentioned Norms and Directives. ¾ Certified in conformity with the UNI EN ISO 9001 Norm by DNV GL. CERTIFICATIONS: Conforms to the 2014/35/UE (low voltage) Directive. The products conform to the requests for the Euroasia market (Russia, Belarus and Kazakhstan). ASSISTANCE/CONTACTS: Headquarters: Esa S.p.A. Via Enrico Fermi 40 24035 Curno (BG) - Italy Tel +39.035.6227411 Fax +39.035.6227499 esa@esacombustion.it www.esapyronics.com International Sales: Pyronics International s.a. Zoning Industriel, 4ème rue B-6040 Jumet - Belgium Tel +32.71.256970 Fax +32.71.256979 marketing@pyronics.be www.esapyronics.com 2

The MRBV & MRBV-CMAP series butterfly valves are suitable for double stage regulation or modulation of ambient temperature air flow in low pressure ducts. A screw-type organ placed on the butterfly valve shaft allows for easy minimum flow regulation with the valve closed. MRBV APPLICATIONS ¾Air flow regulation for impulse controlled burners (ON/OFF or OFF/MIN/MAX). ¾Air flow regulation for modulant burners with minimum adjustable mechanical by-pass. VALVE CHARACTERISTICS - MRBV ¾Maximum working pressure: 210 mbar ¾Maximum fluid temperature: 200 C ¾Drawing capacity with closed valve: about 2% (with closed by-pass seat) ¾Available sizes from DN65 PN16 to DN150 PN16 ¾Coupling flanges: excluded ¾Flange gaskets: excluded ELECTRIC MOTOR UNIT F130203 ¾Model: ECON-V ¾Couple: 5Nm ¾Voltage supply: 24/115/230Vac +10-5% ¾Frequency supply: 50 60Hz ¾Command signal: ON/OFF ¾Working temperature: -10 C +50 C ¾Storage temperature: -20 C +80 C ¾Absorption: 4VA ¾n 2 optional auxiliary switch flow: 5A/250Vac ¾Rotation angle: 90 ¾90 rotation time: 7,5 sec. ¾Manual command: force open ¾Protection degree: IP54 ¾Mass: 1,7 Kg ¾Electric cable inlet: nr. 2 threaded inlets PG 13,5 ¾Mounting position: any ¾Servocontrol attachment holes: DIN ISO 5211 F07 ¾Working environment: not apprpriate in explosive or corrosive environments MRBV MATERIAL COMPOSITION: ¾Valve body: cast iron G40 ¾Lens holder shaft: AISI303 ¾Valve disc: AISI304 ¾Minimum adjustment screw: brass ¾Motor unit case: molten-pressed aluminium ¾Motor unit support: aluminium ¾Surface treatment : phosphate coated F130204 www.esapyronics.com 3

CHARACTERISTICS - MRBV-CMAP MRBV-CMAP VALVE ¾Maximum working pressure: 210 mbar ¾Maximum fluid temperature: 200 C ¾Drawing capacity with valve closed: about 2% (with by-pass seat closed) ¾Available sizes from DN65 PN16 to DN150 PN16 ¾Coupling flanges: excluded ¾Flange gaskets: excluded ELECTRIC MOTOR UNIT: ¾Model: ECON-O ¾Couple: 20Nm (options 4Nm/7Nm/15Nm) ¾Voltage supply: 24/115/230Vac +10-5% ¾Frequency supply: 50 60Hz ¾Command signal: open/close or proportional ¾Type of proportional command: 0-10V 4-20mA (only for ECON-O 24 Vac) ¾Working temperature: -10 C +60 C ¾Storage temperature: -20 C +80 C ¾Absorption: 7VA ¾n 2 optional auxiliary switch flow: 5A/250Vac ¾Open/close mod. potentiometer feedback: nr.1 1000 Ohm (options 150 Ohm/1000 Ohm/2500 Ohm) ¾Proportional mod. feeback signal: 0-10Vdc ¾Rotation angle: 90 ¾90 rotation time: 60 sec. (options from 7 sec. to 120 sec.) ¾Lever shaft connection: panel 9,5 mm ¾AUTO-MAN command station: included ¾Protection degree: IP54 ¾Mass: 2,5 Kg ¾Electric cable inlet: nr. 2 threaded inlets PG 13,5 ¾Mounting position: any ¾Working environment: not apprpriate in explosive or corrosive environments MATERIAL COMPOSITION: ¾Valve body: cast iron G40 ¾Lens holder shaft: AISI303 ¾Valve disc: AISI304 ¾Minimum regulation screw: brass ¾Motor unit case: molten-pressed aluminium ¾Motor unit support plate: Fe360 ¾Motor unit coupling rod: Fe360 ¾Valve command lever: brass ¾Surface treatment: phosphate and zinc coated MRBV-CMAP F1302I05 F1302I06 www.esapyronics.com 4

DESCRIPTION The MRBV series butterfly valves are divided into two categories: double stage regulation valves, identified by the code MRBV and the modulant regulation valves identified by MRBV-CMAP. The valves have been created to allow easy use for the operator. They are made up of a butterfly valve body and a series of leverages placed at the ends. A screw type mechanism allows minimum flow regulation with the valve closed. The MRBV and MRBV- CMAP are meant for automatic applications in which the opening and closing of the butterfly is controlled by an electric motor unit. The MRBV valves have the motor unit directly connected to the valve spindle; an auxiliary limit switch signals the open valve position. In the MRBV-CMAP models, the motor unit is mounted on a support plate and is connected to the valve spindle via a system of slotted levers, rods and adjustable joints, to improve the calibration control according to the apllication needs. The support plate pucturing allows for different types of motor units to be mounted due to the fact that the ECON-O model is not applicable. ESA-PYRONICS supplies the MRBV-CMAP valves with ECON-O motor unit predisposed for regulation from 0 90. All the motor units have a manual command station, two auxiliary limit switches calibrated at 10 and 80 as well as a feedback signal for the position reached. In particular in the models with open/close command the feedback takes place via an ohmic potentiometer, whilst in the models with proportional command an analogical signal in volts is available. www.esapyronics.com 5

FLOW CHART The choice of MRBV valves must be made according to the specific use: if the valve must be used as an interception device, it must have the same diameter as the piping; if it must used as a regulation organ, it must guarantee a charge loss which is compatible with an appropriate regulation. The maximum flow graph identifies the charge loss with a completely open valve. The minimum flow graph instead, identifies the charge loss with a completely closed valve and regulation screw completely open. MAXIMUM 10,0 20MRBV 24MRBV 32MRBV Charge loss [mbar] 48MRBV 1,0 100 1000 Air flow @ 20 C P.S.= 1 [Nm 3 /h] 5000 G1302I01 MINIMUM 100,0 20MRBV 24MRBV 32MRBV 48MRBV Charge loss [mbar] 10,0 1,0 1 10 100 500 Air flow @ 20 C P.S.= 1 [Nm 3 /h] - Regulation screw completely open G1302I02 www.esapyronics.com 6

WARNINGS ¾Make sure that working pressure and fluid temperature is lower than the maximum allowed values. ¾The MRBV valves are supplied without coupling flanges and gaskets. The flanges and gaskets to be applied must be suitable for the type of valve and its application. ¾Check the correct installation of the valve before starting the flow in the pipeline. ¾Check the correct electric connections. Before connecting electricity to the motor unit, make sure that the voltage, frequency and command signals are correct. Check that the user s absoprtion is not higher than the maximum flow of the auxiliary contacts. ¾The motor unit is intended to be electrically connected on a permanent basis. Inverting the connection phase/neutro can compromise the safety of the system. Do not use different phases among the various voltage inlets and do not apply tension on the outlet clamps. ¾Only intervene on the motor unit and its connected devices when there is no voltage supply ( electric current disconnected). Number the conductors before disconnecting the device. ¾To avoid damaging the internal adapter, do not rotate the motor unit shaft neither by forcing the lever nor with tools. ¾In case of motor unit malfunctioning, follow the instructions in the MAINTENANCE chapter of the present manual or contact ESA-PYRONICS assistance. ¾Any modification or repair done by third parties may compromise the application saftey and will automatically cause the general waranty conditions to expire. INSTALLATION To install carefully follow the instructions below: 05 02 04 01 04 02 06 03 03 D1302I01 Maintain a certain distance from surrounding elements allowing air to circulate freely. 3 - Check that the flanges (pos. 02), gaskets (pos. 04) and pipes (pos. 03) are compatible with the valve and with the fluid. 4 - Check the correct alignment of the pipe fittings and check the correct distance between the pipes and the assembly (flanges/gaskets/valve body), to avoid exerting tension on the pipes during the tightening phase. 5 - Weld the flanges (pos.02) at the ends of the pipes, eliminating any residual flash. 6 - Make sure that there are no foreign objects inside the valve nor in the pipes before proceeding to assemble. If necessary remove the impurities. 7 - Position the valve between the two flanges and and then mount the gaskets (pos. 04), bolts (pos.05), washers and nuts (pos. 06). 8 - Using appropriate instruments, progressively screw the bolts on crossing them over each other, avoiding excessive tightening. ASSEMBLY 1 - Place the MRBV valves far from excessive heat sources and products such as: liquids, solvents or corrosive gases. 2 - The valve (pos. 01) may be installed in any position. www.esapyronics.com 7

ELECTRICAL CONNECTION 1 - Check that the motor unit is compatible with the control system, both for voltage supply as well as for the type of command. 2 - Use the inlets that have already been placed on the motor unit for the passage of electric cables, without making other holes in the case. Install cable glands or conduit fittings made to waranty a protection degree equal to or not less than IP40. For systems used in open air, the minimum protection degree must be IP54. The protection degree can also be garanteed by the container in which the device has been put. 3 - The signal command cable of the proportional motor unit must be screened and layed out separately from the power lines (inverter) and network voltage; multipolar cables must not be used. The same applies to the position feedback signals of both motor unit models; open/close as well as proportional type. 4 - If the power feed system is a phase-phase type, it is necessary to install an insulation transformer with a secondary earthing connection. F1302I07 5 - When connecting electricity refer to the technical documentation, respecting the polarity between phase and neutral. The electrical connection clamps are screwon type and can accept section conductors from 0.5 to 2.5mm²; the choice of conductors and their location must be suitable for the application. The numbering and use of appropriate terminals on these conductors is suggested. 6 - Always make sure that earthing protection is connected to the relative clamps and to the motor unit box by conductors withh appropriate sections. 7 - After connecting make sure the conductors do not interfere internally with the motor unit s gear system. Close the lid, checking the correct position of the gasket and verifying that the conductors do not remain pressed between the lid and the box. F1302I08 www.esapyronics.com 8

REGULATION AND SETTING The operations indicated in the following chapter must be carried out by expert qualified technicians. During the regulation phase monitor the duct flow using flowmeters (calibrated flanges, differential pressure gauges, etc...) MRBV VALVE The regulation and setting of the motorized MRBV valves defines the maximum and minimum opening of the valve which is controlled by the electric motor unit. The two limit positions of the valve movement must correspond to the minimum and maximum flow desired. The minimum flow regulation takes place by regulating the minimum screw with the valve closed, whereas the maximum regulation is actuated by reducing the motor unit s stroke. When the valve is fed without command, it is in the closed position. Once it receives the comamnd signal, the butterfly places itself in the maximum opening position. 1 - Open the motor unit lid to get access to the manual command station, afterwhich, connect the motor unit to the electrical supply. 2 - Check that there is no opening command and that the OPEN/CLOSE switch is on the CLOSE position. In these conditions the valve must be closed. 3 - Extract the security dowel (pos.1) from the valve spindle and and act on the regulation screw (pos.2) screwing on to decrease and unscrewing to increase thus obtaing the requested minimum flow. After regulation, screw the security dowel back onto the spindle again (pos. 1) checking that the flow regulation does not vary. 4 - Place the OPEN/CLOSE switch in the OPEN position, so that the shaft rotates allowing the valve to open completely. The S2 cam defines the opening limit position. 5 - Check the flow value with valve completely open: if the value is higher than the maximum requested value, the motor unit stroke must be reduced, making the maximum opening of the cam intervene in advance (S2). 6 - Place the OPEN/CLOSE switch in the CLOSE position so that the shaft rotates making the valve close completely. 7 - Make the maximum opening limit switch intervene in advance using the straight side of the appropriate lever: insert the pivot in one of the holes situated on the sides of the mobile cam crown then drag it to the desired position. If the mobile crown is in the completely backward position, use the curved side of the lever to drag it to a more suitable position for regulation. 8 - Remove the lever before starting the motor unit. Via the OPEN/CLOSE switch, move the motor unit checking that there is the maximum flow requested in the new valve open position. 9 - Place the OPEN/CLOSE switch in the CLOSE position checking that the motor unit respects the control system commands. Finally, close the lid again, checking that the gasket is in the correct position and making sure that the conductors do not remain pressed between the lid and the box. F1302I08 The ECON-V motor units are supplied by the factory already prepared for a 90 rotation on ON/OFF command. The S3 and S4 limit switches are optional and only available on request. 02 01 For the S3 and S4 limit switch regulation, follow the instructions below: 1 - Open the motor unit lid to have access to the manual command station. D1302I02 www.esapyronics.com 9

2 - Via the OPEN/CLOSE switch, place the valve in the desired position, corresponding to the limit switch activation. 3 - Regulate the limit switch cams using the straight side of the appropriate lever: insert the pivot in one of the holes situated on the sides of the mobile cam crown then drag it to the desired position. If the mobile crown is in the completely backward position, use the curved side of the lever to drag it to a more suitable position for regulation. 4 - Remove the lever before starting the motor unit. Via the OPEN/CLOSE switch, move the motor unit checking that the limit switch activation is in the correct position. 5 - Then place the OPEN/CLOSE switch in the CLOSE position and close the lid again checking the position of the gasket and conductors. MRBV-CMAP VALVE The regulation and calibration of the motorized MRBV- CMAP defines the minimum and maximum opening of the valve controlled by the electric motor unit. The two limit positions of the valve movement correspond to the minimum and maximum flow desired. The minimum flow regulation takes place by regulating the minimum screw with valve closed, whilst the regulation of maximum flow takes place by varying the rotation angle of the valve compared to the motor unit, acting on the intermediate controls and joints. Decreasing the motor unit stroke is unadvisable, for models with open/close command, whereas for proportional motor units, it is impossible. 1 - Open the motor unit lid to get access to the manual command station. Place the AUTO/MAN commutator on the manual position indicated by the hand A, afterwhich, activate electric current to the motor unit. 2 - Place the OPEN/CLOSE switch on the q symbol (closed), so that the shaft rotates in the clockwise direction making the valve close completely. The S1 cam defines the closed position limit. 3 - Extract the security dowel (pos.8) from the valve spindle (pos.7) and adjust the regulation screw (pos.9) screwing on to decrease and unscrewing to increase, obtaining the minimum flow requested. After regulation, screw the security dowel back onto the spindle again (pos.8) making sure that the flow regulation does not change. 4 - Place the OPEN/CLOSE switch on the p symbol (open), so that the shaft rotates in the anticlockwise direction opening the valve completely. The S2 cam defines the opening position limit. Check the regulated flow of the valve during the amplitude between maximum and minimum opening positions. 5 - Evaluate the flow regulation carried out by the valve: if the maximum flow is reached before the motor unit gets to the maximum opening, the valve stroke must be redu- A 6 9 8 7 MRBV-CMAP DN PN16 4 5 1 2 3 OPENED CLOSED D1302I03 F1302I09 ced, otherwise it must be increased. 6 - Put the valve back to the minimum opening (see point 2) until the motor unit stops. 7 - Change the position of the joints (pos.02 and pos.05) making them slide into the appropriate jointed levers (pos.01 e pos.04). To decrease the valve stroke compared to the motor unit it is necessary to bring the joint (pos.02) closer to the motor unit pivot (pos.06), or move the joint (pos. 05) away from the valve pivot (pos.07). The difference between the two actions is that, with equal displacement, the one carried out on the jointed lever motor unit (pos.01) changes the valve angle more. 8 - Loosen the rod security dowel which is placed on the valve joint (pos.05). Manually adjust the minimum opening of the valve making the rod slide (pos.03) inside the joint moving the valve via its appropriate jointed lever (pos.04), obtaining the minimum flow previously regulated (see point 3). At the end fasten the security dowel. 9 - Check the new regulation of the valve by repeating the www.esapyronics.com 10

operations indicated between points 4 and 8 until obtaining the requested flow regulation. 10 - Place the AUTO/MAN commutator on the automatic position checking that the motor unit respects the system s control commands. Finally, close the lid again, checking the corect position of the gasket and making sure that the conductors do remain pressed between the lid and the box. The ECON-O motor units are supplied by the factory already prepared for a 90 rotation, with the S3 and S4 limit switches respectively regulated at 10 (S3 minimum opening) and 80 (S4 maximum opening). For the open/close motor units the potentiometer is set for a 90 angle rotation. If the motor unit s rotation is reduced, theresistance variation will be reduced proportionally, whereas if the angle is increased, there will be no further increase in resistance. For motor units with proportional command, all calibrations have already been set by the factory and therefore any intervention on the cam limits (S1 and S2) and on the potentiometer is unadvisable. To adjust the S3 and S4 auxiliary switches follow the indications below: 1 - Open the motor unit lid to get access to the manual command station. Place the AUTO/MAN commutator on the manual position shown by the hand A. 2 - Using the OPEN/CLOSE switch, place the valve in the desired position, corrisponding to the activation of the limit switch. 3 - Regulate the limit switch cam using the straight side of the appropriate lever: insert the pivot in one of the holes situated on the sides of the cam s mobile crown and drag it to the position desired. In case the mobile crown is in the completely backward position, use the curved side of the lever to drag it to the position most suitable for regulation. 4 - Remove the lever before starting the motor unit. Via the OPEN/CLOSE switch, move the motor unit checking that the limit switch is in the correct position. 5 - Finally place the AUTO/MAN commutator in the automatic position and close the lid checking the position of the gasket and conductors. GENERAL MAINTENANCE PLAN Operation Type (*) Suggetsed Schedule Gasket integrity O annual Bolt tightening E annual Motor unit cable connection integrity O half yearly Valve movement O/E half yearly Valve regulation O/E annual Electric motor unit O/E annual Minimum regulation screw integrity E annual Butterfly valve maintenance E annual Notes Check that there are no air fume leaks towards the outside. In case there are vibrations, reduce to half yearly application. Check external insulation integrity as well as the absence of abrasions or overheating of conductors. Check that the valve movement is not hindered in any way. Check the flow regulation carried out by the valve. Check that the commands are respected and check that the auxiliary switches and the feedback signals are correct. Check the condition, cleanliness and functioning of the screw. Check the condition of the internal elements of the valve. NOTES: Key: O = ordinary / E = extraordinary (*) It is advisable to replace the gaskets each time the valve is dismantled. www.esapyronics.com 11

EXTRAORDINARY MAINTENANCE For correct maintenance of the MRBV valves, scrupulously follow the instructions below. Before manouvring anything with the plant on, make sure that the process and operator safety is not compromised. If necessary perform maintenance checks with the plant off. INTEGRITY CHECKS ¾The integrity of the gaskets can be checked visually. If the use of leak detection liquid is necessary, only check if the flow inside the duct is cold and in low pressure. ¾The integrity of the electric cables can be checked visually. If it is necessary to operate on the conductors to check the cables, ishouòd they not be fully visible, disconnect power supply running to the device before carrying out any operation. Before replacing the motor unit, make sure that this is indeed the cause of malfunctioning. VALVE MOVEMENT tude, visually checking that there is no friction nor stroke limits. If the valve is an air or fume interception valve, before performing the operation, switch off the connected burners. VALVE REGULATION - ELECTRIC MOTOR UNIT ¾Check valve regulation with burners off but with the presence of flow in the duct. Check that the flow regulation carried out by the valve is correct, if necessary repeat all the steps indicated in the REGULATION AND SET- TINGS section. ¾Check the motor unit with burners off, with or without flow in the duct. Check that the commnads sent by the control system are carried out by the motor unit and that the feedback position and auxiliary switch signals send the control system the correct indications. If necessary repeat all the steps indicated in the REGULATION AND SETTINGS section. ¾Checking that there is nothing hindering the valve movement must be done by performing a complete ampli- EXTRAORDINARY MAINTENANCE For correct maintenance of the MRBV valves, scrupulously follow the instructions below that are to be carried out when the plant is off. BOLT TIGHTENING ¾ The bolt tightening check must be made when the plant is off and cold. BUTTERFLY VALVE MAINTENANCE - GASKET REPLACEMENT 1 - Close the interception valve upstream the piping and make sure that there is no flow in the duct. 2 - Place the valve in the completely closed position, otherwise it is impossible to extract the piping. 3 - Progressively unscrew the screws which fix the valve in a crossed position. Extract the valve and check the state of its internal components. 4 - Clean the inside of the valve body and the butterfly with a clean cloth and compressed air. Do not use tools that could damage the internal parts. 5 - Check that the fixing screws on the lens holder shaft are tightened correctly. 6 - Make sure that the butterfly moves freely without friction. If necessary lubricate with mineral oil which is suitable for high temperatures. 7 - Replace the gaskets and reassemble the valve in its place, following the steps indicated in the INSTALLA- TION section. 8 - Finally check that the valve moves freely without hinderance. 9 - Check that the regulation carried out by the valve is correct, if necessary repeat all the steps indicated in the REGULATION AND SETTING chapter. MOTOR UNIT REPLACEMENT 1 - Make sure the motor unit is indeed the cause of malfunctioning and check that you have a spare motor unit which is the same as the one that needs to be replaced. 2 - Disconnect electric supply, remove the lid of the motor unit and then disconnect all electrical connections from the clamp. 3 - Unhook the jointed lever (pos. 01) from the pivot on the motor unit (pos. 06) without lossening the regulation of the joints (pos. 02 e pos.05), to facilitate the regulation operations afterwards (motor unit pivot position constant). 4 - Unscrew the fixing screws of the motor unit baseplate and remove it. 5 - Fix the new motor unit onto the support plate, reconnect the jointed lever (pos. 01) from the pivot on the motor unit (pos. 06) paying attention not to erroneously place the butterfly opening indicator. 6 - Put the conductors back into the motor unit case and connect them to the clamp referring to the wiring diagram. 7 - Make sure that the commands sent by the control sytem are carried out by the motor unit and that the feedback position and auxiliary switch signals send the control system correct indications. If necessary repeat all the steps indicated in the REGULATION AND SETTINGS section. www.esapyronics.com 12

OVERALL DIMENSIONS - MRBV 46.5 148 "D" "C" "E" 144.5 Ø"B" Ø"F" "G" D1302I04 Model DN ø B ø C ø D ø E ø F ø G Mass Kg 20MRBV 65 122 60 104 169 24 40 4.6 24MRBV 80 138 68 126 189 24 40 5.1 32MRBV 100 158 81 150 199 28 46 6.6 48MRBV 150 212 110 210 219 32 54 9.9 www.esapyronics.com 13

OVERALL DIMENSIONS - MRBV-CMAP 145 "I" 150 OPEN "H" Ø"B" 45 CLOSED OPEN 45 24 MRBV-CMAP DN80 PN16 132 "G" CLOSED "C" "D" "F" "E" D1302I05 Model DN ø B C D E F G H I Mass Kg 20MRBV-CMAP 65 122 60 108 138 229 40 165 311 5.2 24MRBV-CMAP 80 138 68 128 158 257 40 165 311 6.5 32MRBV-CMAP 100 158 81 138 168 198 46 255 400 7.5 48MRBV-CMAP 150 212 110 158 216 218 54 255 400 11.0 www.esapyronics.com 14

ELECTRIC CONNECTIONS - MOTOR UNIT ECON-V (MRBV) a b c d OPEN COM NC NO COM NC NO Ph L + Ph L + Ph L + N1 2 3 4 16 17 20 21 22 23 24 25 D1302I06 a b Power feed and rotation commands Outputs for position limit reached c S3 auxiliary switch outputs * d S4 auxiliary switch outputs * CLAMP CONNECTOR N1 Neutral feeding 2 Opening command input (phase) 3 Not connected 4 Power feed phase 16 Output for max. opening reached (phase) 17 Output for min. opening reached (fase) 20 Auxiliary switch output S3 (COM)* 21 Auxiliary switch output S3 (NC)* 22 Auxiliary switch output S3 (NO)* 23 Auxiliary switch output S4 (COM)* 24 Auxiliary switch output S4 (NC)* 25 Auxiliary switch output S4 (NO)* * Optional www.esapyronics.com 15

ELECTRIC CONNECTIONS - OPEN/CLOSE MOTOR UNIT ECON-O (MRBV-CMAP) a b c d e CLOSE OPEN COM NC NO COM NC NO MIN SIGNAL MAX Ph L + Ph L + Ph L + N1 2 3 4 16 17 20 21 22 23 24 25 30 31 32 D130207 a b c Power feed and rotation commands Outputs for position limit reached Auxiliary switch output S3 d e S4 auxiliary switch outputs Potentiometer feedback position outputs CLAMP CONNECTOR N1 Neutral feeding 2 Closing command input (phase) 3 Opening command input (phase) 4 Power feed phase 16 Output for max. opening reached (phase) 17 Output for min. opening reached (fase) 20 S3 (COM) auxiliary switch output 21 S3 (NC) auxiliary switch output 22 Auxiliary switch output S3 (NO) 23 Auxiliary switch output S4 (COM) 24 Auxiliary switch output S4 (NC) 25 Auxiliary switch output S4 (NO) 30 Potentiometer feedback output (Minimum) 31 Potentiometer feedback output (Cursor) 32 Potentiometer feedback output (Maximum) www.esapyronics.com 16

ELECTRIC CONNECTIONS - PROPORTIONAL MOTOR UNIT ECON-O (MRBV-CMAP) a b c d e f INPUT OUTPUT COM NC NO COM NC NO 24 Vac 0 Vac Ph L + + IN - IN + OUT - OUT Ph L + Ph L + Ph L + 1 2 3 4 20 21 22 23 24 25 40 41 D1302I08 a Power 24Vac d S3 Auxiliary limit switch output b Analogical comand signal e S4 Auxiliary limit switch output c Analogical reverse action signal f Power feed of optional internal transformer CONNECTING CLAMPS 1 Power inlet of 24Vac 22 Auxiliary limit switch output S3 (NO) 2 0Vac power feed inlet, negative analogical comand signal and negative reverse action analogical comand. 23 Auxiliary limit switch output S4 (COM) 3 Positive analogical comand signal inlet 4 Positive reverse action analogical comand outlet 20 Auxiliary limit switch output S3 (COM) 21 Auxiliary limit switch output S3 (NC) 24 Auxiliary limit switch output S4 (NC) 25 Auxiliary limit switch output S4 (NO) 40 Power feed phase of optional internal transformer 41 Neutral of optional internal transformer www.esapyronics.com 17

90 MRBV & MRBV-CMAP - E1302 rev. 04-07/04/11 OVERALL DIMENSIONS - MOTOR UNIT ECON-V (MRBV) M8 No.4 HOLES 108 Ø70 Ø50 148 M6 No. 4 HOLES 108 36 22.5 108 61 142 13 81 Ø4 7No. Ø10 2 PLUGS PG13.5 56 D1302I09 www.esapyronics.com 18

OVERALL DIMENSIONS - MOTOR UNIT ECON-O (MRBV-CMAP) 200 17 166 17 115 152 50 0 180 90 143 50 POWER END 85 2xPg13,5 12 183 126 103.3 9,5 144 124 7 D1302I10 www.esapyronics.com 19

ORDER CODE - MRBV - MRBV - 01 02-03 Model 01 02 Voltage DN65 DN80 DN100 DN150 20 24 32 48 24 Vac +10-15% 115 Vac +10-15% 230 Vac +10-15% 24 115 230 03 Optional limit switch Not installed Present / S ORDER CODE - MRBV-CMAP - MRBV - CMAP - 01 02-03 Model 01 02 Motor unit voltage feed DN65 DN80 DN100 DN150 20 24 32 48 24Vac 50 60Hz 115Vac 50 60Hz 230Vac 50 60Hz 24V 115V 230V 03 (*)Command type Proportional (only 24V) In current In voltage 4-20mA 0-10V (*) Not applicable for models with open/close command www.esapyronics.com 20