SMC Auto Switch Variations

Similar documents
Applicable Auto Switch Model

2 Pneumatics. Auto Switch Guide. Applicable Cylinder Series 1 CDA2-X1184 MDB-X1184 CDQ2-XB14 CDG5 S HYDB CDJ5 S CDJP2 CDQM MDU CDQS HYDQ CDJ2 MDB1

CDA2-X1184 MDB-X1184 MDB1 CDA2 CDUJ CDU CDS1 CDS2. ø12 to ø20. ø125 to ø160. ø6 to ø32. ø6 to ø10 P.1516

2 4times. Compact Cylinder/Guide Rod Type. ±0.2 or less. Guide Rod. Load can be directly mounted.

Applicable Auto Switch Variations

2 4times. Compact Cylinder/Guide Rod Type. Guide rod. Load can be directly mounted. Mounting dimensions compatible with the CQS, CQ2 series.

Applicable Cylinder Series

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3)

Elliptical design for space-savings

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes

Reed Switches/Direct Mounting Type D-Z73/Z76/Z80

Compact Type Dual-Rod Cylinder

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80

Slide Unit. Series CXWM/CXWL. Slide bearing/cxwm: ø10, ø16, ø20, ø25, ø32 Ball bushing bearing/cxwl: ø10, ø16, ø20, ø25, ø32

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting

Toggle Type Air Gripper

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Air Cylinder: Standard Type Double Acting, Single Rod. How to Order. Standard stroke (mm) ø6 15, 30, 45, 60. Cushion Nil A

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting

Series MSU. Rotary Table. High Precision. Vane Type/Sizes 1, 3, 7, 20. High precision series MSUA introduced to vane type rotary tables CAT.

Valve Mounted Cylinder Double Acting, Single Rod. How to Order. Electrical entry. L L plug connector M M plug connector. G Grommet

Series C95 ø32, ø40, ø50, ø63, ø80, ø100

A rectilinear rotation unit that compactly integrates a slim cylinder and a rotary actuator.

Series MXY. Air Slide Table Long Stroke. ø6, ø8, ø12. A long-stroke type of Series MXP air slide table with integrated linear guide is newly released.

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing. How to Order CY1L 25 H 300 J79W. Load voltage 5 V 200V 100 V 12 V 5 V, 12 V

Series MHZ2/MHZJ2. Parallel Type Air Gripper. Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type.

CAT.ES A -UK. Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released.

SeriesMHZL2 How to Order

Dual-Rod Cylinder Compact Type

Compact Hydraulic Cylinder

New cylinder body allows small auto switches to be mounted on 4 surfaces.

140 mm. Mechanically Jointed Rodless Cylinder. Series MY3A/3B. Scale: 100% Height reduced by 36% at the maximum * Overall length reduced by

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space

Series CE2. Brake mechanism added to a stroke reading cylinder which can measure stroke length. Stroke Reading Cylinder with Brake

140 mm. Mechanically Jointed Rodless Cylinder. Series MY3A/3B. Scale: 100% Height reduced by 36% at the maximum * Overall length reduced by

Series MXH. Compact Slide. ø6, ø10, ø16, ø20

Dual-Rod Cylinder Compact Type

3-Position Rotary Table

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece

Series MXU ø6, ø10, ø16

Microspeed Cylinders

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

Mini Free Mount Cylinder

CAT.ES A. Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm.

Series MLGP. Low Profile Guide Cylinder with Lock. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions

How to Order. Standard stroke (mm) ø10 15, 30, 45, 60

Free Mount Cylinder. Series CU. A space saving air cylinder with multiple surfaces for mounting. The series consist of an array of cylinders.

CAT.ES Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm.

CAT.ES20-53 E. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

EX-F70 SERIES EX-F60 SERIES

Series CRJ. Mini-Rotary Actuator. Rack-and-Pinion Type/Size: 05, 1

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Rotary Actuator Rack & Pinion Style

Compact Hydraulic Cylinder. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. How to Order Z73. Bore size. 20mm 25mm 32mm 40mm 50mm 63mm 80mm 100mm

Air Cylinder. ø6, ø10, ø16. Easy installation. Reduced piston rod deflection

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

Air Cylinder. New RoHS. Series CJ2. are. added to the mounting types. Improved amount of mounting freedom Head cover with boss is added.

Rotary Actuator Rack & Pinion Style

Electric Cylinders. It can be operated like an air cylinder. Directional control driver like a solenoid valve

Electric Cylinders. It can be operated like an air cylinder. Directional control driver works like a solenoid valve

Series CY1F. Magnetically Coupled Rodless Cylinder Low Profile Guide Type

Round Type Hydraulic Cylinder

Vane Type Rotary Actuator 50, 63, 80, 100

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

Series MHZJ2. How to Order MHZJ2 16 D F9PV. Body option. Nil. Port. Port

Round Type Hydraulic Cylinder

Series MHY2/MHW Angular Gripper. Series MHY/Cam Style. Light and compact size in small bore sizes. Auto switch mounting at 4 locations

Mini Free Mount Cylinder

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

SA1W: Water Detection Sensors

Series RQ. The new standard for the future. Compact Cylinder with Air Cushion. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

Small Bore Hydraulic Cylinder

Mounting style. B Basic style L Foot style. Shaft type. S Single shaft W Double shaft Not available for ø30. Size 11 - C D R A 1 B S C - A53

Vane Type Rotary Actuator

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Cylindrical Inductive Proximity Sensor GX-M SERIES

Trimmer Auto Switch Series D- 7K/D-R K

Series MXH. ø6, ø10, ø16, ø20. Compact Slide

Series MXP. Precision Air Slide Table. ø6, ø10, ø12, ø16. Size ø6 (with stroke adjuster and auto switches) and shock absorber introduced to series MXP

3 Pneumatics. Valve Mounted Cylinders CV MVGQ. Valve Mounted Cylinders. Series CVQ. Series CVJ5. Series CVJ3. Series CVM5/ CVM5K Double acting

Compact Cylinder: Standard Type Double Acting, Single Rod. How to Order 30 D F9BW. Body option <Standard stroke> Nil C M. Double acting.

Lube, Non-lube: ø125, ø140, ø160, ø180, ø200, ø250, ø300 Air-hydro: ø125, ø140, ø160. How to Order. Bore size. 125mm 140mm 160mm

Mini Free Mount Cylinder

Series CRJ. More Compact! Mini-Rotary Actuator Rack-and-Pinion Type/Size: 05, 1

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

Air Cylinder. ø6, ø10, ø16. Easy installation. Reduced piston rod deflection

Compact Cylinder ISO Standards [ISO/21287]

High-speed detection even a little liquid leak

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

2-Color Display High-Precision Digital Pressure Switch

Transcription:

SMC Auto Variations Mounting Function Style method Electrical entry Auto switch model No. Page D-C7/C7/C80 D-B5/B54/B4 5.-9 5.- Connector D-C7C/C80C 5.- Terminal conduit D-A/A4 D-AA/A4A 5.- 5.- DIN terminal D-A44 D-A44A 5.- 5.- General purpose auto switch Connector Terminal conduit DIN terminal Connector D-A72/A7/A80 D-A72H/A7H/A7H/A80H D-A7C/A80C D-A5/A54/A5/A4/A7 D-AC/A4C D-A44C D-A90/A9/A9 D-A90V/A9V/A9V D-90/97 D-90A/9A D-Z7/Z7/Z80 D-E7A/E7A/E80A D-H7A1/H7A2/H7B D-G59/G5P/K59 D-H7C 5.-14 5.-15 5.-1 5.-17 5.-18 5.-19 5.-20 5.-21 5.-22 5.-2 5.-24 5.-29 5.-0 5.-1 Solid state switch Terminal conduit Connector Terminal conduit D-G9/K9 D-G9A/K9A D-F79/F7P/J79 D-F7NV/F7PV/F7BV D-J79C D-F59/F5P/J59/J51 D-G9C/K9C D-F9N/F9P/F9B D-F9NV/F9PV/F9BV D-Y59A/Y7P/Y59B D-Y9A/Y7PV/Y9B 5.-2 5.- 5.-4 5.-5 5.- 5.-7 5.-8 5.-9 5.-40 D-M5N/M5P/M5B 5.-41 General purpose auto switch 5.- mounting mounting mounting mounting

SMC Auto Variations Mounting Function Style Electrical entry Auto switch model No. Page method The suitable operating point can be indicated with green light. (Red Green Red) 2 color indication style 2 color indication style with diagnostic output Reed switch Solid state switch The output signal can be detected in an unsteady detecting area. Water resistant 2 color indication Solid state switch Water (coolant) resistant performance With timer Solid state switch With built-in OFF-delay timer (200ms) Solid state switch D-B59W D-A79W D-A59W D-H7NW/H7PW/H7BW D-G59W/G5PW/K59W D-F79W/F7PW/J79W D-F7NWV/F7BWV D-F59W/F5PW/J59W D-M5NW/M5PW/M5BW D-Y7NW/Y7PW/Y7BW D-Y7NWV/Y7PWV/Y7BWV D-F9NW/F9PW/F9BW D-F9NWV/F9PWV/F9BWV D-H7LF (Latching style) D-H7NF D-G59F D-F7LF (Latching style) D-F79F D-F5LF (Latching style) D-F59F D-H7BAL D-G5BAL D-F7BAL D-F5BAL D-Y7BAL D-F9BAL D-G5NTL D-F7NTL D-F5NTL D-M5NTL/M5PTL Possible to use in an environment where disturbance magnetic fields are generated. 5.-25 5.-2 5.-27 5.-42 5.-4 5.-44 5.-45 5.-4 5.-47 5.-48 5.- 5.-49 5.-50 5.-51 5.-52 5.-5 5.-5 5.-54 5.-55 5.-5 5.-57 5.-58 5.- 5.-7 5.-59 5.-0 5.-1 5.-2 RB J D -X 20- Technical Data Strong magnetic field resistant Solid state switch 2 color indication D-P5DWL 2 color indication with diagnostic output Water resistant 2 color indication With timer 5.-4 5.-4

Prior to Use Auto Specifications Precautions Refer to "Auto Precautions" in p.0-44 to 0-4 before handling. Auto Common Specifications Auto switch style Current leakage Operating time Shock resistance None 1.2ms 00m/s 2 Solid state switch wire: 0 µa or less, 2 wire: 1mA or less 1ms or less () 00m/s 2 Insulation resistance 50 M Ω or more at 500MV DC (between lead wire and the case) Withstand voltage Ambient temperature 1500V AC/min. (between lead wire and the case) (1) to 0 C 00V AC/min. (between lead wire and the case) Protective construction IEC529 Standard IP7, Waterproof construction (JISC0920) (2) Note 1) Connector style (D-A7C/A80C/C7C/C80C) and D-9/9 A/A9/A9 V style: 00V AC/min. (between lead wire and the case) Note 2) IEC529 Standard IP, Rainproof construction (JISC0920) for Terminal conduit style (D-A/A A/A C/G9/G9A/G9C/K9/K9A/K9C) and DIN teminal style (D-A44/A44A/A44C). Note ) Except solid state switch with timer (D-M5 TL, G5NTL, F7NTL, F5NTL) and Auto switch for strong magnetic field resistance (D-P5DWL). D-J51: 5ms or less Lead Wire Length How to Order Ex.) 5.-5 D-A7 L Lead wire length 0.5m L m Z N 5m None Applicable for the connector style (D- C) only Note 1) Applicable auto switch with 5 meter lead wire ("Z") : D-B5/B54, D-C7 (C)/C80C,D-A7(C)(H)/A80C D-A5/A54, D-Z7, D-90/97/90A/9A Solid state switch: Manufactured upon receipt of order as standard (Except D-F9/F9 V) Note 2) The standard lead wire length of solid state switch with timer or with water resistant 2 color indication is meters. (Not available 0.5m) Note ) The standard lead wire length of strong magnetic field resistant solid state switch is or 5 meters. (Not available 0.5m.) Part No. of lead wire with connector (Available for connector style only.) Part No. D-LC05 D-LC0 D-LC50 Lead wire length 0.5m m 5m Change of Lead Wire Color Lead wire colors of SMC auto switches have been changed in order to meet Nippon Electric Control Equipment Industries Association Standard No. 402. 2 wire auto switch wire auto switch Output (+) Output ( ) Power supply Old Red Old Red New Solid state auto switch with diagnostic output New GND Output White Diagnositc Yellow output Orange Power supply GND Old Red New Output White Solid state auto switch with latching style diagnostic output Power supply GND Old Red New Output White Latching style diagnostic outout Yellow Orange

Prior to Use Auto Hysteresis/Contact Protection Box Contact Protection Box/CD-P, CD-P 1 The following auto switches are not incorporated with the contact protection box. D-A7/A8, D-A7 H/A80H, D-A7C, A80C, D-C7/C8, D-C7C/C80C, D-E7 A, E80A, D-Z7/Z8, D-9/9 A, D-A9/A9 V, and D-A79W type Use an auto switch with a contact protection box in any case listed below. Unless using a contact protection box, the contact life may be shortened. (Due to permanent energizing conditions.) D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length. qoperating load is an inductive load. wthe wiring length to load is more than 5m. ethe load voltage is 0 or 200 V AC. 2 Contact SMC when using built-in contact protection style (D-A4[A] [C], D-A44[A] [C], D-A54/A4, D-B54/B4, D-A59W, D-B59W) in the following conditions: q The wiring length to load is more than 0m. w When using PLC with large flow current Contact Protection Box/Internal Circuit ( ): If applicable for IEC Standard CD-P CD-P Contact Protection Box/Dimensions Contact Protection Box/Specifications Part No. CD-P voltage 0V AC max. 200V AC Max. load current 25mA.5mA Lead wire length - connecting side 0.5m connecting side 0.5m CD-P 24V DC 50mA Auto Hysteresis The distance between the turn-on point (ON) of the switch by moving of the piston to the turn-off point (OFF) is called "Hysteresis". This hysteresis is included as part of the operating range (one side). Contact Protection Box/Connection Method For connection of the switch body and the contact protection box, connect the lead wire in the side indicated as "SWITCH" on the contact protection box to the lead wire from the switch body. The length of lead wire between the switch body and the contact protection box should be within 1m and they should be set as close together as possible. RB J D -X 20- Technical Data Note) Hysteresis may fluctuate due to the operating environment. Contact SMC if the hysteresis causes a problem. 5.-

Prior to Use Auto Connection Method/Connection Example Basic Wiring Solid state switch wire NPN wire PNP ciruit 2 wire ciruit 2 wire Indicator protective (When power source for switch and load is not common.) ciruit Indicator protective Typical PLC (Programmable Logic Controller) Connection Circuits Sink input wire NPN IN Source input wire PNP IN Connect according to the input specification of PLC because the connection method varies with the input specification of PLC. COM PLC internal 2 wire 2 wire IN COM IN PLC internal COM PLC internal COM PLC internal AND (Serial), OR (Parallel) Connection Examples wire NPN/AND connection (with relay) NPN/AND connection (with switch) NPN/OR connection 1 2 Relay Relay Relay contact 1 2 1 2 Indication lights up when both switches are ON. 2 wire (2 pcs.) AND connection 1 2 When 2 switches are connected by AND, load voltage will decrease at ON and these connections may cause malfunction of load. Indication lights up when both switches are ON. voltage at ON=Supply voltage-internal drop voltage X 2 pcs. =24V-4V X 2 pcs. =1V Example) Supply voltage 24V DC, switch internal drop voltage 4V OR connection [Solid state switch] When 2 switches are connected by OR, load voltage will increase at OFF and these connections may cause 1 malfunction. [] There is no current leakage so that load voltage does not in- crease at OFF. 2 The flowing current is broken up into the ON-state switches, so indicator light becomes dark or may not turn ON due to the lack of the current. voltage at OFF=Leakage current X 2 pcs. X impedance =1mA X 2 pcs. X k½ =V Example) impedance k½, switch leakage current 1mA 5.-7

Reed / Mounting D-A72/D-A7/D-A80 Electrical entry : Perpendicular Applicable Actuator Series Series Bore size (mm) CDJ2, CDVJ CDXW CDY1S, CY1L ø, ø1 ø, ø1, ø20, ø25, ø2, ø40, ø50, ø, ø80, ø0, ø5, ø140, ø Plate mounted ø, ø1, ø20, ø25, ø2, Housing mounted ø1, ø20, ø25, ø2 ø, ø, ø15, ø20, ø25, ø2, ø40 ø1, ø20, ø2, ø40, ø50 ø25, ø2, ø40, ø50, ø ø, ø20, ø2, ø40, ø50, ø ø20, ø25, ø2, ø40, ø50, ø ø2, ø40 Internal Circuit ( ): If not applicable for IEC Standard D-A72 D-A7 D-A80 LED Resistance Zener diode (Red) () Contact protection box CD-P LED (Red) Contact Resistance protection box Zener diode CD-P CD-P () Contact protection box CD-P CD-P Choke coil Surge absorber OUT(+) (Red) Note) qin the case operation load is an inductive load. win the case the wiring length to load is > 5m. ein the case the load voltage is 0 or 200V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. D-A72 must be used with contact protection box. Refer to p.5.- for the details of contact protection box. to OUT(±) (Red) to OUT( ) () ± OUT (Red) to OUT () OUT( ) () Specifications PLC: Programmable Logic Controller D-A7 (With indicator light) Auto switch model number D-A72 D-A7 Application Relay/PLC Relay/PLC voltage 200V AC 24V DC 0V AC current range 5 to ma 5 to 40mA 5 to 20mA Contact protection None Internal voltage drop ² 2.4V Indicator light ON: When red light emitting diode D-A8 (Without indicator light) Auto switch model number D-A80 Application Relay/IC /PLC voltage AC 24V DC or less 48V AC DC 0V AC DC Max. load current 50mA 40mA 20mA Contact protection None Internal resistance 1½ or less (Including m lead wire) Lead wire Oilproof vinyl heavy insulation cable, ø.4, 0.2mm 2, 2 cores (, ), 0.5m Note 1) Refer to common specifications on the p.5.-5. Note 2) Refer to the p.5.-5 for lead wire length. Dimensions Operation Range ( l Dimension) Actuator series CDJ2, CDVJ B CDXW P CDY1S CY1L 8 15 1 9 20 Bore size 25 2 40 50 Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%) 80 0 5 140 (mm) 5.-14 RB J D -X 20- Technical Data

Solid State / Mounting D-F79/D-F7P/D-J79 D-F79 D-F7P Internal Circuit ( ): If not applicable for IEC Standard DC(+) (Red) OUT (White) DC( ) () Applicable Actuator Series Series CDJ2, CDVJ, CDVJ5 CD XW CDY1S, CY1L Specifications D-F7 /D-J79 (With indicator light) Auto switch model number D-F79 Wiring Output Application Power voltage Current consumption voltage current Internal voltage drop Current leakage Indicator light Dimensions Bore size (mm) ø, ø1 ø, ø1, ø20, ø25, ø2, ø40, ø50, ø, ø80, ø0, ø5, ø140, ø Plate mounted(p), ø, ø1, ø20, ø25, ø2, Housing mounted(b), ø1, ø20, ø25, ø2 ø, ø, ø15, ø20, ø25, ø2, ø40 ø20, ø25, ø2, ø40, ø50 ø25, ø2, ø40, ø50, ø ø, ø20, ø2, ø40, ø50, ø ø20, ø25, ø2, ø40, ø50, ø ø2, ø40 D-F7P wire NPN PNP IC /Relay/PLC 5//24V DC (4.5 to 28V DC) ² ma ² 28V DC ² 40mA 1.5V or less 0.8V or less at ma of load current ² 0µA at 24V DC PLC: Programmable Logic Controller 80mA or less 0.8V or less ON: When red light emitting diode D-J79 2 wire 24V DC Relay/PLC 24V DC ( to 28V DC) 5 to 40mA 4V or less ² 0.8mA at 24V DC Lead wire Oilproof vinyl heavy insulation cable, ø.4, 0.2mm 2, cores (,, ), 2 cores (, ), 0.5m Note 1) Refer to common specifications on p.5.-5. Note 2) Refer to p.5.-5 for lead wire length. RB J D -X 20- D-J79 DC(+) (Red) OUT (White) DC( ) () OUT(+) (Red) OUT( ) () Operation Range ( l Dimension) Actuator series CDJ2, CDVJ, CDVJ5 B CD XW P CDY1S, CY1L 5 15 4 1 5 4 2.5 20.5 Bore size 25 2 40 50 5.5.5.5 5 4 2.5 7.5.5 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%).5.5.5.5.5 80.5 (mm) 0 5 140 7 9 9 8.5 Technical Data 5.-4

Information w How to Mount and Move the Auto Mounting Bracket mounting <Applicable auto switch> D-A72, D-A7, D-A80, D-A72H, D-A7H, D-A7H, D-A80H D-A7C, D-A80C, D-A79W Solid state switch D-F79, D-F7P, D-J79, D-F7NV, D-F7PV, D-F7BV, D-J79C D-F79W, D-F7PW, D-J79W, D-F7NWV, D-F7BWV D-F79F, D-F7LF, D-F7BAL, D-F7NTL How to mount and move the auto switch qslide the auto switch mounting nut inserted into the mounting rail and set it at the auto switch mounting position. wfit the convex part of auto switch mounting arm into the concave part of auto switch mounting rail. Then slide the switch over the nut. ( series: Fit the convex part of auto switch mounting arm through the auto switch spacer into the concave part of auto switch mounting rail.) Part No. of auto switch mounting bracket (including nut, screw and spacer) Cylinder series 5.-71 1 20 25 2 40 Mounting screw set (Stainless steel specification) Use the following mounting screw set (Nut included.) according to the required operating conditions. (Auto switch spacer is not included.) BBA2: For D-A7/A8/F7/J7 D-F7BAL is mounted on the cylinder with the above stainless steel screw BBA2 before shipment of BBA2 is enclosed with D-F7BAL when shipped without cylinder. epush the auto switch mounting screw lightly into the mounting nut through the hole of auto switch mounting arm. rafter reconfirming detection position, tighten the mounting screw to secure the auto switch. (Tightening torque of M screw should be 0.5 to 0.7Nm.) tmodification of the detecting position should be made in the condition of e. Bore size (mm) 50 80 0 5 140