Magnetic Proximity Switch MSW-L (Latching Type) DC/AC Version CE Classification: M2C235AU9

Similar documents
M-100 Adjustable flow switch with right-angle flow

LEVEL SWITCH WITH 1 FLOAT

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

3 Port Solenoid Valve

Basic Motor Theory. Introduction

40 Series - Miniature PCB relays A. Features

Electrical Measuring Instruments

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

Reed, Electronic. MOVEMENT > Proximity switches Series CST-CSV-CSH GENERAL DATA

DG 060 DG 061 DG 062 DG 063 DG 064 for Pressure and High Pressure Filters Operating pressure up to 600 bar Response/switching pressure up to 5,0 bar

Charles Flynn s Permanent Magnet Motor.

EMC Issues in Electric Drives

Clogging Indicators. Description. Page 393. Application Monitoring the contamination of pressure and high pressure filters.

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

90 Series - Socket overview for 60 series relays

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

HI-POT/CONTINUITY TESTER Model PLEP01

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary

CPLab / CP Factory. Application module magazine. Data sheets

Note 8. Electric Actuators

MAGNETIC PROXIMITY SWITCHES

Inline Ultrasonic Flowmeter

BELT-DRIVEN ALTERNATORS

CORROSION RESISTANT IN LINE FLOW SWITCHES

94 Series - Socket overview for 55 series relays

ELECTROMAGNETISM. 1. the number of turns. 2. An increase in current. Unlike an ordinary magnet, electromagnets can be switched on and off.

Chapter 4 Ignition & Electrical Systems

Pluggable interface relays RT, PT and MT range

Shape - Typical designs with sector angles of pi/2 [90 degrees], and 2pi/3 [120 degrees] are shown below.

Inductive Proximity Sensor

Materials can be classified 3 ways

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

5 mm contact pin pitch PCB or 95 series sockets

Self-Adjusting Hall Effect Gear Tooth Sensor IC CYGTS9802 with Complementary Output

Instrumental technique presentation

SG-B1 SERIES / SG-A1 SERIES

Self-Adjusting Two-Wire Hall Effect Gear Tooth Sensor IC CYGTS9804

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

7.9.8 Elctromagnetism

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

Temperature Probes. Operating Range: -40 F to 140 F -40 C to 60 C

Induction motors advantages of induction motors squirrel cage motor

Magnetism and Electricity ASSIGNMENT EDULABZ. the mere presence of magnet, is called...

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0)

Hydro-Flow Model 2200 Installation and Operation Guide B

Sensor boxes SRBE Key features and product range overview

Safety Sensor CSS 180 Product Information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

1. What type of material can be induced to become a temporary magnet? A) diamagnetic B) ferromagnetic C) monomagnetic D) paramagnetic

EXPERIMENT 5 (a) PRESSURE, PROXIMITY AND MAGNETIC FIELD SENSORS

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Specification of Battery Charger

Compact System NRGS 11-2 NRGS Original Installation Instructions English

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

General purpose relays 6-10 A

A Practical Guide to Free Energy Devices

2 pole 10 A PCB mount A1 A

Cautions in Using The Relays 1/5

Reed Technology. standexmeder.com

21.2 Electromagnetism

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

HFS - High Frequency Limit Level Sensor

Electrical position feedback for actuator sizes Ø mm

MAGNETO-INDUCTIVE POSITION DETECTORS

Technical data. Standards: IEC/EN chromated and painted Protection class: IP 67 to EN 60529

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Contents. 1. Preface Product Outline Model Number Construction Specifications Outline Drawings and Wiring diagram...

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Science 30 Unit C Electromagnetic Energy

QUASAR KIT No THYRISTOR - TRIAC TESTER

55 Series - Miniature General Purpose Relays 5-10 A

Non-Contact Phase Rotation Tester

Ch 4 Motor Control Devices

User Manual Solar Charge Controller 3KW

Specifications. Fluid Ambient and fluid temperature ( C)

Chapter 22: Electric motors and electromagnetic induction

EXPERIMENT 13 QUALITATIVE STUDY OF INDUCED EMF

MS.RAJA ELGADFY/ELECTROMAGENETIC PAPER3

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

EVS RP6020. Instruction Manual

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

Onboard power supply management

The Discussion of this exercise covers the following points:

Schmidt Mess- und Regeltechnik

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Operating Manual for the RE-19 Multi-pin Valve Terminal

2006 MINI Cooper S GENINFO Starting - Overview - MINI

EMC Compatible enclosure assembly

MAGNETIC EFFECTS OF ELECTRIC CURRENT

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Transcription:

SYGNATECH,INC. 3215 Golf Rd, #266, Delafield, WI 53018 USA Phone: (262) 646-2464 Fax: (262) 646-2392 Magnetic Proximity Switch MSW-L (Latching Type) DC/AC Version CE Classification: M2C235AU9 SYG.MSWL/man11, 2003 1

GENERAL DESCRIPTION Magnetic proximity switches are used to detect the position of a moving object without mechanical actuation. The MSW-L switches have been specially designed for mine hoist applications. The distinctive feature of MSW-L switches is their high sensitivity, allowing them to be activated from a relatively long distance from the actuating magnet. The switch also has a heavy duty, corrosion resistant red brass enclosure to ensure reliability against the harsh conditions normally present in mining applications. Switch type MSW-L offers latching type operation. It will stay either open or closed after being subjected to a magnetic field. Its state (open/closed) is maintained even after power supply failure. These are ideal for detecting the position of a mine hoist conveyance in the shaft. From the connection point of view, the MSW-L switch operates as ordinary contact with 2 terminals. The MSW switches can operate with different types of actuating magnets. For mine hoist applications, we recommend Sygnatech MM-1 magnets. They are flat, relatively thin, and easy to mount on the side of the conveyance. The standard version is type MM-1-S, which has the South pole facing the switch.. SYG.MSWL/man11, 2003 2

DIMENSION DRAWINGS SWITCH MSW-L MAGNET MM-1-S Note: The same magnet is available with magnetic North pole on the operating side. Its designation is MM-1-N SYG.MSWL/man11, 2003 3

PRINCIPLE OF OPERATION The state of the latching proximity switch (open or close) depends on the direction of the magnetic field the switch was subjected to. This principle makes it ideal for determination of the position of the object fitted with permanent magnet. A typical example is a mine hoist conveyance in the shaft. When the conveyance is above the switch (passed the switch on the way up) the switch is in one state (for example closed) but when the conveyance is below the switch (passed the switch on the way down) the state of the switch changes (in this example from closed to open). The operation principle of the MSW-L switch is shown below. In Zone H, the switch status could be closed or open, depending on the direction of movement. If the magnet is moving down the switch is closed in Zone H and opens when the magnet reaches Switch Open Zone. If the magnet is moving up, the switch is open in Zone H and closes when the magnet reaches Switch Closed Zone. Note, that the undefined Zone H is wider if the magnet is oriented vertically. So if a narrow Zone H is required, the magnet should be mounted in a horizontal position. SYG.MSWL/man11, 2003 4

PRINCIPLE OF OPERATION(cont d) Some features of the MSW-L latching switch: The magnet should travel along the arrow marked on the cover of the switch. The switch cover can be mounted in 4 positions, 90 degrees apart. This allows matching the existing position of the switch to the direction of travel and polarity of the magnet. The switch state (open, closed) depends on the polarity of the magnet and direction of its travel. If the South Pole of the magnet is facing the switch, the switch closes when the magnet passes it in the direction pointed by the arrow on the switch cover. When the magnet passes the switch in other direction it opens. Passing the switch several times in the same direction (by magnet of the same polarity) does not change the state of the switch. Reversing the action of the switch (opening/closing) for the same direction of magnet travel can be done either by turning the switch cover of 180 degrees or by reversing the polarity of the magnet. The advantage of latching switches is that their state (open/closed) indicates that the conveyance has passed the switch and is above or below. Also, latching action allows easy assessment of the proper switch operation, which is rather difficult in case of pulse switch and fast speed conveyance (very short pulse duration). If the path of the magnet is very close to the switch it might produce additional short pulse when the magnet is in the vicinity of the switch. This however does not result in an incorrect state after the magnet passed the switch - its state will always be as described above. SYG.MSWL/man11, 2003 5

TECHNICAL DATA Type of operation Operating distance with MM-1 magnet Latching (bistable) 10 inch (254 mm) - standard, 15 inch (381 mm) - sensitive Output contact Reed Switch Number of connecting wires 2 Max. size of connecting wires Rated voltage Rated current Maximum switching current Maximum switching power Weight (approx) Dimensions 12 AWG (3.3 mm2) 120 VDC/AC 0.2 A DC/AC 1.0 A DC/AC 25 W (DC), 25 VA (AC) 14.8 lbs (6.7 kg) 9.3x5.4x3.2 inch (235x137x83 mm) Environmental conditions: Ambient temperature -40 to +170 deg F (-40 to +76 deg C) Humidity 0 100 % Altitude -15,000 ft to + 20,000 ft (-4572m to +6096 m) SYG.MSWL/man11, 2003 6

ELECTRICAL CONNECTIONS Basic Circuit Diagram Remarks: With the inductive load and AC application, it is advisable to have a voltage arrestor across the load in form of varistor or RC-type suppressor. With the inductive load and DC application, it is advisable to have a voltage arrestor across the load in form of varistor or free-wheeling diode. SYG.MSWL/man11, 2003 7

Mechanical Installation: INSTALLATION INSTRUCTIONS The switch should be mounted using the 4 mounting holes on its base. The surrounding of the switch, especially the area between the switch and the passing magnet should be free from the ferromagnetic material (steel, iron) which could attract the magnetic flux from the magnet thus deflecting it from the switch and reducing its sensitivity. The switch should be mounted in the vicinity of the passing magnet, with the arrow on the cover parallel to the movement path of the magnet. For reliable operation the distance between the surface of the switch and the magnet should be about 50 to 90% of the operating distance of the switch. For standard MSW-L switch with operating distance of with 10 inches (254 mm), this relates to about 5-9 inches (127-228 mm). For the sensitive version, this distance would be 7.5-13.5 inches (190 343 mm). The position of the switch base should be either vertical (with the cable entry from the bottom) or horizontal. For convenience, the cover of the switch is fixed to the base with 4 mounting screws and can be mounted in 4 directions to match the path of the actuating magnet and required operation of the switch (opening or closing) The MSW-L switches can operate with different types of actuating magnets. For mine hoist applications, however, we recommend using Sygnatech MM-1 magnets. They are flat, relatively thin, and easy to mount on the side of the conveyance. Similarly as the switch, the magnet should not have any ferromagnetic material in front of or on its side. However, if magnet MM-1 is used, it can be mounted directly on the conveyance or on a non-magnetic plate mounted on the surface of the steel conveyance. The non-magnetic plate prevents magnetization of the conveyance below or above the magnet, thus eliminating the possibility of false action of the switch. The switch state (open, closed) depends on the polarity of the magnet and direction of its travel. If the South Pole of the magnet is facing the switch (MM-1- S), the switch closes when the magnet passes it in the direction pointed by the arrow on the switch cover. When the magnet passes the switch in other direction it opens. In applications where the switch can be subjected to falling rocks it is advisable to provide a protective shield for the switch and connecting cable in form of a steel rod or beam, mounted minimum 20 inches (500 mm) above the switch. SYG.MSWL/man11, 2003 8

Electrical Installation: INSTALLATION INSTRUCTIONS 1. The electrical installation should follow local electrical codes and regulations. 2. The switch connections are done by removing the switch cover and connecting the cable conductors to 2 switch wires using screw type terminals inside the switch. Maximum size of cable conductor - AWG12 (3.3 mm2). It is not important which wire of the switch is connected to the load. Ground connection should be done using grounding screw on the switch body, inside the switch. 3. After connecting the wires, the cover of the switch has to be remounted on the switch base. Make sure connecting wires do not get between the cover and the flat surface of the switch base. 4. The cover should be aligned with the arrow pointing the proper direction as described in Principal of Operation. The four mounting bolts should be tightened with a torque of about 3 ft-lbs (4 Nm). 5. In a wet environment, even though the switch is sealed, there is a possibility of a moisture development inside the switch. Adequate protection in such case is provided by covering the connecting points of switch wires and cable conductors with Vaseline see picture below. SYG.MSWL/man11, 2003 9

MAINTENANCE INSTRUCTIONS The switch is basically maintenance free. Periodical visual inspections have to be done in order to check the integrity of the switch (integrity of connecting cable, integrity of the enclosure, integrity of the actuating magnet). The frequency of these checks depends on the local condition the switch operates in. If the supply voltage of the switch does not have ground fault detection, periodical insulation test should be conducted. It is recommended to use insulation tester with the voltage between 250V and 500 V. The frequency of this test depends on the local conditions and regulations, but it is suggested to do it at least once per year. SYG.MSWL/man11, 2003 10