STC 2W160 Series Solenoid Valves

Similar documents
STC 2L Series Solenoid Valves

STC 2W Series Solenoid Valves

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

STC 2P025 Series Solenoid Valve

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

3V SERIES SOLENOID VALVE

4V130P-430P SERIES AIR PILOT VALVE

2V1-3V1 SERIES SOLENOID VALVE

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC 2E Series High Pressure Solenoid Valves Two-Way, Pilot Piston, Normally Closed

S T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM

STC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves

STC KS/KD Air Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

KS/KD Air Actuated Ball Valves

AIR & ELECTRIC ACTUATED VALVES

STC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders

Kirby Fridgebox TM Series IV Outdoor Condensing Unit

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

POWER BANK 规格书 POWER BANK SPECIFICATION. Cell(1S2P)+Housing 电芯 (1S2P)+ 胶壳 MB 组合类型 : Product Model. 成品型号 : Pack Capacity (mah) Pack Type

right and left as used throughout this manual are determined by facing the direction the machine will travel when in use.

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

HR-20P Pneumatically Controlled Pressure Regulator

BI-PIPE INSTALLATION MANUAL. AUDI PERFORMANCE & RACING 1027-B Opelika Road Auburn Alabama 36830

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

XMQ6900J PARTS CATALOGUE

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Solids Control. Centrifugal Pump

II DISTRIBUTION & SUBSTATION TYPE C

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

OWNERS MANUAL JANUARY 2007 ISO

WEB CONTROL PRODUCTS

ADI-125/750 ADI-125/1500 ADI-125/2500

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

DAP-625S and DAP-875S

INSTALLATION INSTRUCTIONS

Straight-Bore Clutch LSCC-32, 44, 54

PARTS ORDERING INSTRUCTIONS

Terms and Conditions

GWC Valve International

Type Flexair Pneumatic Pressure Control Valves

Preface. and reliability etc. can reach to the present international level, and the environmental protection criterions, such as

10 Year Limited Warranty

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

FCB-450, LCB-600, MCB-800

Packaging 22Mar11 Rev Y Specification MOD JACK ASSY, VERTICAL, COMPLIANT PIN, 8 POSN

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

DC to AC Power Inverters

MityFlex Peristaltic Pump

2015 & 2018 Fender Brace Installation Instructions

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

List prices are for individual parts See following pages for illustration of parts by number

Installation / Operation Instructions Sunnex ORION Series Exam Lights

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

MIL-24/2600Q MIL-24/3200DQ

FR1118- P10. User s Manual

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

K-Motion Valve Springs are the choice of winning racers. K-Motion

2003-Up Mitsubishi EVO 8. Installation of the Rear Coil Springs

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

P/N# Performance Lowering Springs Installation Instructions

DC to AC Power Inverters

OWNERS MANUAL JANUARY 2007 ISO

Losi (LOSB9810) 2400mAh 11.1V LiPo Transmitter Battery for JR Z1, KoPropo Helios, and Other Radios of Similar Battery Configuration

22421 SPORT SWAY BAR SET TOYOTA COROLLA

END USER TERMS OF USE

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

TYPE S RELAY VALVE (Volume booster) Service Manual

BMRX Series ROTARY LEVEL CONTROL

PIVOT BUSHING KIT GM F-BODY

Web Volume Control Model WV220

1401 / 1402 / 1403 ADJUSTABLE TRAILING ARM MOUNT BRACES INSTALLATION OF HOTCHKIS PERFORMANCE ADJUSTABLE TRAILING ARM MOUNT BRACES

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

SULZER (RLB76) ITEM PART NO. 中文名称 ENGLISH DESCRIPTION

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

SPC-PANEL Simplex, Single Phase Pump Control Panel

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Dual Fueler CP3 Pump Kit Installation Guide for LBZ/LMM

Installation Instructions

Power. On Your Terms.

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Sport Sway Bar Kit UP SCION xb

V-Twin Forward Control Installation Instructions

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

Rear Suspension System C-10 Pickup Truck

Freedom Designs, Inc. Embroidery Catalog. Over 50 New Design Options! Freedom 12Pg Embroidery Self Cov 1

OWNER'S MANUAL SLT-330F Scissor Lift Table

EZR7 Universal 7-Pin Heavy Duty Plug Installation Instructions and Product Warranty Professional Installation Required

THD-2-FM CONTROLAIR VALVE

Installation Power Management Unit Battery Cables and Battery Harness

94-96 Impala SS/ B-Body Rear Coilover Conversion Kit

Chicane Coilover Kit For '64 to '72 Chevelle/ A Body. Installation Instructions

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

Sport Sway Bar Kit Chevy Camaro

Transcription:

STC 2W60 Series Solenoid Valves 2W60 Series Solenoid Valve Specifications Valve Model 2W60-3/8 Valve Type 2 Way, Normally Closed (NC) Action Direct Lift Diaphragm, Uni-Directional Orifice 6 mm Operating Pressure 0 to 50 PSI Proof Pressure 750PSI Operating Temperature) Media: -5 to 80 C; Ambient: -5 to 5 C Port Size (NPT) 3/8 Body Materials Brass Seal Materials NBR (Buna) Coil Duty Class H, IP65, 00% ED Voltage Voltage Options: 2, 2VDC; 2, 0/20, 220/20 VAC, 50/60Hz Voltage Tolerance 0% of Specificed Voltage Coil Power 20W Electrical Connections DIN 3650, Form A Service Air, Gas, Liquid, Vacuum Life Cycles (Air) Greater than 500,000 cycles S T C TM

2

Installation and Operation: To connect the valve Inlet and Outlet: Connect the inlet and outlet in the direction of the arrow marked on the valve. To connect DIN coil:. Remove the Philip screw from the plastic housing and unplug it from the DIN coil. 2. From the screw opening, push the terminal block out from the plastic housing. 3. Note the, 2 and ground markings on underside of DIN enclosure.. For DC DIN Coil, Connect to Positive, 2 to Negative. 5. For AC DIN Coil, connect to HOT wire, 2 to Neutral wire, and if required connect Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil. The coil temperature may become hot after being energized for extended periods, but it is normal. Smoke or burning odor indicates excessive coil temperature and should disconnect the power to the coil immediately. Operation: 2W60 series valve is a 2/2 Direct Lift Diaphragm Normally Closed, zero differential, solenoid valve. When the valve receives an electrical signal, a magnetic field is formed which attracts the plunger covering the main orifice to lift off, causing system pressure to drop. As system pressure on the top of the diaphragm is reduced, full system pressure on the other side of the diaphragm acts to lift the diaphragm away from the main orifice, which allows media to flow through the valve. Since the bleed orifice is dimensionally smaller than the pilot orifice, the system pressure cannot rebuild on the top of the diaphragm as long as the pilot orifice remains open. When the valve is de-energized, it releases its hold on the plunger. Then the plunger forced by the spring drops and covers the main orifice. The system pressure builds up on the top of the diaphragm through the bleed orifice, forcing the diaphragm down until it covers the main orifice and stops media flow through the valve. 3

7 6 5 3 2 0 9 8 7 6 5 3 2 序号 GB859-87 GB802-88 2W60-5-3 2W60-5-2 2W60-5- 2W60-5-0 2W60-5-09 2W60-5-08 2W60-5-07 2W60-5-06 2W60-5-05 GB70-85 GB859-87 2W60-5-0 2W60-0-03 2W60-5-02 2W60-0-0 代 号 盖型螺母轻型弹垫铭牌旋钮铁壳线圈总成弹簧导磁板 先导头总成密封垫动铁芯总成内六角螺钉轻型弹垫拉簧阀盖膜片总成 名 阀体 称 数量 材 A3 65Mn LY2 塑料冷扎板 Cr8Ni9Ti?0.6.8 29 6 冷扎板 PTFE 5Mn 65Mn Cr8Ni9Ti HPb59- HPb59- 料 总计单件重量 Kg 备 M0?0 M6 6?6?0.7 2.8 0 5 STC 注 标记处数设计校对审核工艺 分 区 更改文件号签名标准化审定制图批准 年月日 阶段标记 共 3 张 重量比例 : 第 张 电磁阀装配图 2W60-0-00

2W60 Series Valve Installation Dimensions 5

Catalog No.: PUB09C-2W60 Terms and Conditions By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as agreed in writing signed by us. We reserve the right to correct typographic errors and reject orders. SHIPMENTS: All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 9303, USA. Most orders are shipped via UPS Standard Ground unless instructions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping. RETURN OF MERCHANDISE: No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully prepaid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error. Shortages & Mis-Shipments: Any shortages or mis-shipment must be reported within 5 days. CANCELLATION POLICY: Blanket order can be canceled 90 days before scheduled ship date. There will be a 0% charge if a blanket order is cancel within 90 days of scheduled ship date, and a 20% charge if cancel within 60 days. Regular order for non-custom parts can be canceled any time before the order is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever comes later.. Remittances should be sent to: Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 9303, USA Credit Card Payments: Visa, MasterCard, Discover, or American Express Accepted International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card. Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account numbers. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER: Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This limited warranty expires one year after delivery to the end-user. STC s entire obligation to the Purchaser for breach of this limited warranty shall be limited to replacement of the defective product or refund of the original purchase price of this product, at STC s option. Purchaser has thirty (30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser. STC s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during handling or storage.. DISCLAIMER OF IMPLIED WARRANTIES: All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular application. OBLIGATIONS You warrant, represent and agree: () to comply with all laws; (2) that our sale and shipment of the product will not, by export thereof, your legal status or otherwise, cause us to violate any law; and (3) to indemnify us against any losses from a failure by you or a third party to comply with law or these terms and conditions, or from use of the product. SAFETY WARNING: Improper Selection or Failure to follow Usage Instructions of the products described on the Sizto Tech Corporation (STC) Internet Site and its related publications can cause Death, Personal Injury, and Property Damage. All system set-ups require the supervision of a qualified individual who is familiar with installation, inspection and testing through training or experience. IMPORTANT NOTICE: All prices are subject to change without notice. We continuously improve the products, and we reserve the right to change specifications without incurring any obligation to incorporate new factors in equipment previously sold. Information contained herein may be changed without prior notification. S T C Sizto Tech Corporation 892 Commercial Street Palo Alto, CA 9303 USA Tel: 650-856 8833 Fax: 650-856 88 Email: Sales@StcValve.com; www.stcvalve.com 6