SMOKEX EMERGENCY SMOKE EXTRACT AIR VENT T E C H N O L O G Y. C E certified to Class F300/120 or F400

Similar documents
"LCA"- long cased axial fan

MAJAX-2 GENERAL SPECIFICATION

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES

Bifurcated Case Axial Fans (BIFA)

Axial fans. What s more, non-stock models are normally available within two weeks.

TGT Series Adjustable Pitch Fans

Short casing. Long casing (L version) Commercial premises

Max. airflow m 3 /s Diam. min. Diam. max

TGT Series Adjustable Pitch Fans

ExpressBuild STANDARD FAN RANGE

Novenco axial flow fans. ZerAx - Standard January 2010

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Hison Axial Flow Fans

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Size and Configurations

High Performance Axial Fans

Hison Axial Flow Fans

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Performance. Sound Levels. Impellers. Motors. Accessories

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Novenco Tunnel Fans. Novax October 2007

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Sabre Plate Mounted Sickle Fans (VSP)

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

WINDER. Impellers with higher efficiency and less sound level

Section 4. Axial Fans - Section 4

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

SECTION AXIAL HVAC FANS

NOVENCO FAN CATALOGUE

REVOLUTION SLCX Product Brochure

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Acoustic Twin Fans (ATQ)

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

SILENT MV Ultra Quiet In-line Fans

JM Aerofoil Multi-Stage 50 Hz

AC Commercial Fans Edition. ErP ready

ROOFMASTER STEF-HT ROOF FAN

DUCT-M HT F400/2h. Smoke exhaust ducted axial fan APPLICATIONS TECHNICAL SPECIFICATIONS VERSIONS ACCESSORIES ON REQUEST. May 2018 Catalog N 000 Rev.

CGT Series Adjustable Pitch Fans

SECTION CENTRIFUGAL HVAC FANS

ROOFMASTER STEF-HT ROOF FAN

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

CGT Series Adjustable Pitch Fans

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

MTF. Technical features

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.


Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Uniclass L7534. Manufacture controlled to ISO9001

SECTION HVAC POWER VENTILATORS

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

BIFLOW SB CON Product Brochure

JM Aerofoil Bifurcated Fans

Defining Innovation. backward curved FANs

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Multi-Port Centrifugal Fans for Round Duct

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

HIGH INDUCTION DIFFUSERS WITH VARIABLE GEOMETRY

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

SMART Application Structure Acoustics s n fa f o o R

BIFURCATED AXIAL FANS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

HIGH TEMPERATURE TWIN SQUIF FANS

TURBOFLOW TF Contra Rotating Axial Flow Fan

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Twin City Fan & Blower

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

FEATURES & BENEFITS UPON REQUEST

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

BPF. Centrifugal Plug Fans

Radial roof fans - SMART-UL. Application. Stylistics. Structure. Efficiency adjustment. Acoustics

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Transcription:

EMERGENCY SMOKE EXTRACT AIR VENT T E C H N O L O G Y C E certified to Class F300/120 or F400

Emergency Smoke Extract dex LCA-JT/HT SMOKEX Axial impulse fans for car park ventilation F300/120 - F400 Pages 4-5 JTCHT SMOKEX Centrifugal induction fans for car park ventilation F300/120 Pages 6-7 CAHT SMOKEX High efficiency duct axial fans F300/120 - F400 Pages 8-14 LCAHT SMOKEX High performance duct axial fans F300/120 - F400 CRHHT SMOKEX Centrifugal roof fans F400 Page 15 Pages 16-18 CRHT SMOKEX Vertical discharge centrifugal roof fans F400 PRQ/HT SMOKEX Backward curved centrifugal fans F400 CBBHT SMOKEX Belt driven double inlet box fans F400 Pages 19-22 Pages 23-26 Pages 27-30 Car Park Ventilation - Principles and Solutions Pages 31-33 Accessories Pages 34-39 Page 2

Emergency Smoke Extract Principles and Solutions troduction The mechanical ventilation systems shown in this catalogue resolve the problems connected to smoke extraction at high temperature and are the ideal solution for emergency extraction in case of fire. Potential Risks in Fire Situation release of gas and toxic substances causing eyes to water and consequent difficulty in escaping ashes can be suspended in the atmosphere leading to reduced or no visibility development of very high temperatures the increase of carbon monoxide and reduction of oxygen in the air (possibly leading to asphyxiation) Function and Advantages of Mechanical Ventilation in Case of Fire 1. Mechanical ventilation removes smoke and fumes produced by a fire and by creating negative pressure (in the ambient) it prevents smoke spreading into other parts of the building. This makes it easier for people to escape and simplifies the job of the fire and rescue services. 2. enclosed areas, temperatures can easily exceed 1000 C, causing combustion from heat radiation and mak ing any external extinguishing opera tion useless. Keeping the tempera ture relatively low (300-400 C) by extracting hot air, can avoid the collapse of support structures. addition, the higher oxygen levels will cause better combustion and thus, for most materials, a lower production of toxic smoke. 3. Mechanical ventilation allows the siting of the exhaust outlets away from the fire. High temperature axial fans are easily connected to a duct system. 4. Mechanical ventilation allows the extraction of cold fumes, which since they remain at a lower level are dangerous and are difficult to remove using static systems. 5. Mechanical ventilation allows for ventilation in normal circumstances (clean air), using products with two speed motors: at low speed for normal ventilation (so with lower noise level) and at high speed for emergency conditions. For this type of operation, it is necessary to install the fan with a dedicated power line that automatically operates in case of fire. Certification Emergency Smoke Extract fan design and installation is regulated by the European standard EN12101-3, which establishes the temperature ranges/operation time certified products must comply with. The SMOKEX range is CE certified to classes F300 and F400 and guaranteed to operate at 300 C for two hours in compliance with EN12101-3 standard by the Applus laboratories in Barcelona. Page 3

JET FANS impulse fans for car park ventilation LCA-JT/HT F300/120 & F400 Certificate 0370-CPR-2095 Certificate 0370-CPR-2094 3/4 week delivery Description Axial impulse fans suitable for installation in underground car parks and/or tunnels. They have been designed and certified for the handling of smoke and hot gases caused by fire. These fans are dual purpose, i.e. they provide both normal ventilation (carbon monoxide removal) and smoke control in case of fire. the standard configuration for normal ventilation (CO extract), the range can be used up to a temperature of +60 C. The fire/smoke extraction models (HT) are CE certified to class F300 or F400, and guaranteed to operate at 300 C for two hours in compliance with Standard EN12101-3 by the Applus laboratories in Barcelona. The special impulse induction fan technology represents the most innovative and cost-effective alternative to traditional ducted mechanical extraction systems. There is a drastic reduction in the cost of installation (no need for ducted and grilled systems) and considerable running cost savings (the same fan controls polluted air and smoke and hot gases). Additionally, it is possible for sections of the system to operate only when the need arises (with other sections of the system not operating). Construction Silencers in galvanized steel sheet lined with high performance acoustic insulation material. Deflector on outlet side for optimum air discharge and directional control. Supplied as standard. Protection guard on inlet side. Fixing brackets in galvanized steel sheet for ceiling (or wall) installation. Supplied as standard and pre-assembled. Silencers are fitted at both ends with a specially designed smooth bell shape to improve air performance, reduce loss, and lower sound level. Housing in electrolytically galvanized steel sheet. Hub impeller and aerofoil profile blades in aluminium. They are balanced according to ISO 1940 G.6.3. with variable pitch angle. Terminal box IP54, resistant to high temperature and supplied as standard. or Asynchronous three-phase motors 380-420V 50 Hz conforming to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE. Suitable for DOL (Direct On Line) start. CE marked. Protection IP55, class F or H. Execution 4 (with impeller directly coupled to motor with feet) Also available Non SMOKEX models suitable for continuous operation to a maximum of 60ºC. Size 350mm. Models with 100% reversible airflow. Service switch IP67 for high temperature, assembled. Service switch - IP67 tested & guaranteed for high temperature Terminal Box - IP54 high temperature resistant Page 4

JET FANS impulse fans for car park ventilation LCA-JT/HT Technical Data Airflow m 3 /sec Airspeed m/sec Thrust N @ 3m Speed (400V) Amps Volts - 50 Hz LCA-JT312HT 1.28 17.3 27 54 2790 0.75 1.57 380-420 LCA-JT312/4HT 1.28/0.64 17.3/8.7 27/07 54/43 2820/1400 0.80/0.20 1.91/0.60 380-420 LCA-JT402HT 2.88 22.3 78 58 2870 1.50 3.01 380-420 LCA-JT402/4HT 2.88/1.44 22.3/11.2 78/20 58/47 2900/1435 1.50/0.37 3.54/1.25 380-420 LCA-JT404HT 1.44 11.2 20 47 1430 0.55 1.36 380-420 LCA-JT312T 1.28 17.3 27 54 2830 0.55 1.50 380-420 LCA-JT402T 2.88 22.3 78 58 2825 1.50 3.40 380-420 LCA-JT404T 1.44 11.2 20 47 1330 0.18 0.70 380-420 Temp Class F300/120 F400 +60ºC Dimensions (mm) Fixing Brackets Protection Grid Deflector Service Switch Model A B ØC D E F G H 1 Weight kg LCA-JT310 415 375 415 240 630 200 134 1595 6 65 LCA-JT400 500 460 500 270 800 230 134 1965 6 80 Page 5

Centrifugal induction fans for car park ventilation JTCHT F300/120 Certificate 0370-CPR-2096 3/4 week delivery Description Centrifugal induction fans suitable for installation in underground car parks and/or tunnels. They have been designed and certified for the handling of smoke and hot gases caused by fire. These fans are dual purpose, i.e. they provide both normal ventilation (carbon monoxide removal) and smoke extract in case of fire. The fans are suitable for continuous operation at +40 C and are CE certified to F300 class and guaranteed to operate at 300 C for two hours, in compliance with Standard EN12101-3 by the Applus laboratories in Barcelona. The special impulse induction fan technology represents the most innovative and cost-effective alternative to traditional ducted mechanical extraction systems. There is a drastic reduction in the cost of installation (no need for ducted and grilled systems) and considerable running cost savings (the same fan controls polluted air and smoke and hot gases). Additionally, it is possible for sections of the system to operate only when the need arises (with other sections of the system not operating). Construction Hub impeller and aerofoil profile blades made in aluminium and balanced according to ISO 1940. Housing in electrolytically galvanized steel sheet. Protection guard on inlet side. Fixing brackets in galvanized steel sheet for ceiling (or wall) installation. Supplied as standard and pre-assembled. or Asynchronous three-phase double polarity motors 380-420V 50 Hz. Suitable for continuous operation in maximum ambient temperature of 40ºC (service S1) Will operate for 2 hours in temperature up to 300ºC (service S2) CE marked. Protection IP55, class H. Suitable for continuous running (S1). Execution 5 (with impeller directly coupled to motor shaft). Also available Service switch IP67 for high temperature, assembled Page 6

Centrifugal induction fans for car park ventilation JTCHT Technical Data Airflow m 3 /sec Airspeed m/sec Thrust N @ 3m Speed (400V) Amps Volts - 50 Hz Temp Class JTC254/8HT 1.5 26.9 50 70/53 1400/700 1.2/0.3 3.3/1.40 380-420 JTC304/8HT 2.7 30 100 71/55 1400/700 2.2/.055 5.6/2 380-420 -20ºC to +40ºC F300/120 Dimensions (mm) Model A B C D E F G H 1 J K L Weight kg JTCHT250 830 863 897 415 186 458 740 252.5 230.5 740 1170 1206 78 JTCHT300 1000 1074 1067 500 243 515 852 308 291 852 1425 1457 100 Page 7

High efficiency duct axial fans CAHT F300/120 & F400 Certificate 0370-CPR-2093 Certificate 0370-CPR-2092 3/4 week delivery Description The CAHT range are high efficiency duct axial fans designed for high temperature smoke extraction.these fans are dual purpose, i.e. they provide both normal ventilation (carbon monoxide removal) and smoke extract in case of fire. The fans are suitable for continuous running at the temperature of +70 C and are certified to F300 or F400 class and guaranteed to operate at 300 C for two hours, in compliance with Standard EN12101-3 by the Applus laboratories in Barcelona. The CAHT fans are a range of fixed performance models specifically sized to represent the typical duties required in smoke extract situations. Dimensions (mm) Construction Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EURO-VENT standard. Protected against atmospheric agents by epoxy paint High efficiency axial impeller in diecast aluminium with aerofoil profile blades, optimised for high temperature operation. Balanced according ISO 1940. Variable pitch angle in still position. Execution 4 (with impeller directly coupled to motor with feet) and air flow from impeller to motor. or Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F or H, F300 or F400 certified according to the European Directive EN 12101-3 Accessories Extended casing let cone High temperature flexible connector Flat protection grid Support feet Counter-flange Counter-flange with collar Cylindrical silencers Roof terminal kit Anti-vibration mounts Also available External terminal box for high temperature, ready assembled Model A ØB ØC ØD E ØF G kg CAHT310 200 310 355 395 8 10 380 22 CAHT350 200 350 395 446 8 10 380 25 CAHT400 230 400 450 496 8 12 430 30 CAHT450 230 450 500 546 8 12 430 38 CAHT500 250 500 560 598 12 12 440 39 CAHT560 250 560 620 658 12 12 440 42 CAHT630 250 630 690 730 12 12 470 52 CAHT710 250 710 770 810 16 12 520 66 CAHT800 350 800 860 910 16 12 580 125 CAHT900 350 900 970 1030 16 16 680 180 CAHT1000 350 1000 1070 1130 16 16 750 215 Page 8

High efficiency duct axial fans CAHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 3 m Phase Poles Speed CAHT312 T 2 2790 0.75 1.57 55/F 80 67 CAHT314 T 4 1430 0.55 1.36 55/F 80 51 Phase Poles Speed CAHT352 T 2 2790 0.75 1.57 55/F 80 73 CAHT354 T 4 1430 0.55 1.36 55/F 80 56 Phase Poles Speed CAHT402 T 2 2870 1.50 3.01 55F 90 76 CAHT404 T 4 1430 0.55 1.36 55% 80 69 Phase Poles Speed CAHT452 T 2 2840 2.20 4.48 55/F 80 77 CAHT454 T 4 1430 0.55 1.36 55/F 80 63 Page 9

High efficiency duct axial fans CAHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 3 m Phase Poles Speed CAHT504A T 4 1440 1.10 2.63 55/F 90 66 CAHT504B T 4 1415 0.75 1.71 55/F 80 63 CAHT504C T 4 1430 0.55 1.36 55/F 80 64 Phase Poles Speed CAHT506A T 6 930 0.37 1.23 55/F 80 65 CAHT506B T 6 930 0.37 1.23 55/F 80 63 CAHT506C T 6 930 0.37 1.23 55/F 80 61 Phase Poles Speed CAHT564A T 4 1420 1.50 3.19 55/F 90 70 CAHT564B T 4 1440 1.10 2.53 55/F 90 67 CAHT564C T 4 1415 0.75 1.71 55/F 80 67 Phase Poles Speed CAHT566A T 6 930 0.37 1.23 55/F 80 64 CAHT566B T 6 930 0.37 1.23 55/F 80 64 CAHT566C T 6 930 0.37 1.23 55/F 80 65 Page 10

High efficiency duct axial fans CAHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 3 m Phase Poles Speed CAHT634A T 4 1420 2.20 3.19 55/F 90 74 CAHT634B T 4 1440 1.50 2.53 55/F 90 71 CAHT634C T 4 1415 1.10 1.71 55/F 80 71 Phase Poles Speed CAHT636A T 6 930 0.55 1.62 55/F 80 68 CAHT636B T 6 930 0.37 1.23 55/F 80 68 CAHT636C T 6 930 0.37 1.23 55/F 80 68 Phase Poles Speed CAHT714A T 4 1410 3.00 5.94 55/F 100 77 CAHT714B T 4 1420 2.20 4.61 55/F 100 72 CAHT714C T 4 1420 1.50 3.19 55/F 90 72 Phase Poles Speed CAHT716A T 6 920 0.75 1.97 55/F 90 71 CAHT716B T 6 930 0.55 1.62 55/F 80 71 CAHT716C T 6 930 0.37 1.23 55/F 80 72 Page 11

High efficiency duct axial fans CAHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 3 m Phase Poles Speed CAHT804A T 4 1465 5.50 10.6 55/F 132 79 CAHT804B T 4 1430 4.00 7.62 55/F 112 78 CAHT804C T 4 1410 3.00 5.94 55/F 100 76 Speed Phase Poles (5/10 blades) CAHT804A5/10 T 4 1430 4.00 7.62 55/F 112 76 CAHT804B5/10 T 4 1410 3.00 5.94 55/F 100 74 CAHT804C5/10 T 4 1420 2.20 4.61 55/F 100 76 Phase Poles Speed CAHT806A T 6 940 1.50 3.78 55/F 100 75 CAHT806B T 6 925 1.10 2.82 55/F 90 75 CAHT806C T 6 920 0.75 1.97 55/F 90 74 Speed Phase Poles (5/10 blades) CAHT806A5/10 T 6 925 1.10 2.82 55/F 90 69 CAHT806B5/10 T 6 920 0.75 1.97 55/F 90 69 CAHT806C5/10 T 6 930 0.55 1.62 55/F 80 69 Page 12

High efficiency duct axial fans CAHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 3 m Phase Poles Speed CAHT904A T 4 1465 11.0 21.0 55/F 160 82 CAHT904B T 4 1465 7.50 14.2 55/F 132 80 CAHT904C T 4 1430 5.50 10.6 55/F 132 78 Speed Phase Poles (5/10 blades) CAHT904A5/10 T 4 1465 5.50 10.6 55/F 132 76 CAHT904B5/10 T 4 1430 4.00 7.62 55/F 112 75 CAHT904C5/10 T 4 1410 3.00 5.94 55/F 100 74 Phase Poles Speed CAHT906A T 6 960 3.00 6.82 55/F 132 74 CAHT906B T 6 940 2.20 5.36 55/F 112 73 CAHT906C T 6 940 1.50 3.78 55/F 100 71 Speed Phase Poles (5/10 blades) CAHT906A5/10 T 6 940 1.50 3.78 55/F 100 71 CAHT906B5/10 T 6 925 1.10 2.82 55/F 90 69 CAHT906C5/10 T 6 920 0.75 1.97 55/F 90 69 Page 13

High efficiency duct axial fans CAHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 3 m Phase Poles Speed CAHT1004A T 4 1455 15.0 28.4 55/F 160 88 CAHT1004B T 4 1455 11.0 21.0 55/F 160 85 CAHT1004C T 4 1455 7.50 14.2 55/F 132 83 (5/10 blades) Phase Poles Speed CAHT1004A5/10 T 4 1465 7.50 14.2 55/F 132 86 CAHT1004B5/10 T 4 1465 5.50 10.6 55/F 132 86 CAHT1004C5/10 T 4 1465 4.00 7.62 55/F 112 85 Phase Poles Speed CAHT1006A T 6 960 5.50 12.2 55/F 132 86 CAHT1006B T 6 960 4.00 8.74 55/F 132 84 CAHT1006C T 6 960 3.00 6.82 55/F 132 82 Speed Phase Poles (5/10 blades) CAHT1006A5/10 T 6 940 2.20 5.36 55/F 112 81 CAHT1006B5/10 T 6 940 1.50 3.78 55/F 100 81 CAHT1006C5/10 T 6 925 1.10 2.82 55/F 90 81 Page 14

Duct axial fans LCAHT F300/120 & F400 Certificate 0370-CPR-2098 Certificate 0370-CPR-2097 Description The LCAHT range are duct axial fans designed and certified for high temperature smoke extraction. They have been designed specifically for applications where precise, high performances are required. This is primarily due to the high specification impeller which is fundamentally stable at high temperature and high speed. LCAHT fans are suitable for continuous running at the temperature of 70 C and are CE certified to class F300 or F400, and guaranteed to operate at 300 C for two hours in compliance with Standard EN12101-3 by the Applus laboratories in Barcelona. Construction Casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EURO-VENT standard. Protected against atmospheric agents by epoxy paint High performance axial impeller with aerofoil profile blades. Made in die-cast aluminium. Balanced according ISO 1940. Variable pitch angle in still position. Execution 4 (with impeller directly coupled to motor with feet) and air flow from impeller to motor. or Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F or H, F300 or F400 certified according to the European Directive EN 12101-3 3/4 week delivery Accessories Extension with inspection door let cone High temperature flexible connector Flat protection grid Support feet Counter-flange Counter-flange with collar Cylindrical silencers Roof terminal Anti-vibration mounts Also available Casing protected against atmospheric agents by hot dip galvanizing. High temperature external terminal box. All these fans are custom made to order - performance details therefore available upon request Dimensions (mm) Model A ØB ØC ØD E ØF G Kg LCAHT400 230 400 450 496 8 12 430 30 LCAHT450 230 450 500 546 8 12 430 38 LCAHT500 250 500 560 598 12 12 440 39 LCAHT560 250 560 620 658 12 12 440 42 LCAHT630 250 630 690 730 12 12 470 52 LCAHT710 250 710 770 510 16 12 520 66 LCAHT800 350 800 860 910 16 12 580 125 LCAHT900 350 900 970 1030 16 16 680 180 LCAHT1000 350 1000 1070 1130 16 16 750 215 LCAHT1120 350 1120 1190 1250 20 16 750 235 LCAHT1250 350 1250 1320 1380 20 16 750 265 LCAHT1400 450 1415 1470 1540 20 16 850 515 LCAHT1600 450 1615 1680 1730 24 18 850 550 Page 15

Centrifugal roof fans CRHHT F400 Certificate 0370-CPR-2091 Description The CRHHT range are centrifugal roof fans for direct or duct application. They are suitable for high temperature smoke extraction. The range is CE certified to F400 by the Applus laboratories in Barcelona to EN12101-3. Dimensions (mm) Construction Base frame in galvanized steel sheet. Protection guard in drawn steel rod protected against atmospheric agents and manufactured according to UNI 10615:1997. Backward curved impeller in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according to ISO 1940. Upper cover in ABS, with appropriate slots for motor cooling (controlled collapse of cowl in case of fire) or Asynchronous three-phase motors manufactured according to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Electric supply: 400V/50HZ three phase. Accessories Counter base for secure fixing. let side guard. Model A B C D E F G ØH ØI KG CRHHT40 900 640 38 650 600 530 471 296 12 30 CRHHT45 900 650 38 650 600 530 471 296 12 38 CRHHT50 1100 750 38 760 710 650 550 320 14 55 CRHHT56 1100 750 38 760 710 650 550 370 14 57 CRHHT63 1300 850 38 930 870 775 665 430 14 75 CRHHT71 1300 880 38 930 870 775 665 480 14 94 CRHHT75 1300 880 38 930 870 775 665 480 14 108 CRHHT80 1300 880 38 930 870 775 665 530 14 118 Page 16

Centrifugal roof fans CRHHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 6 m Phase Speed CRHHT40 High T 1400-.055 1.06 55/F 80 49 CRHHT40 Low T 910-0.55 0.90 55/F 80 39 Phase Speed CRHHT45 High T 1400-0.75 2.20 55/F 80 53 CRHHT45 Low T 910-0.75 1.30 55/F 80 44 Phase Speed CRHHT50 High T 1400-1.10 2.80 55/F 90S 57 CRHHT50 Low T 910-1.10 1.60 55/F 90S 47 Phase Speed CRHHT56 High T 910-0.55 2.00 55/F 80 52 CRHHT56 Low T 680-0.55 1.30 55/F 80 46 Page 17

Centrifugal roof fans CRHHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 6 m Phase Speed CRHHT63 High T 910-1.10 3.40 55/F 90L 55 CRHHT63 Low T 690-1.10 2.00 55/F 90L 49 Phase Speed CRHHT71 High T 930-1.50 4.30 55/F 100L 57 CRHHT71 Low T 700-1.50 2.50 55/F 100L 51 Phase Speed CRHHT75 High T 940-1.80 5.00 55/F 100L 61 CRHHT75 Low T 700-1.80 2.90 55/F 100L 56 Phase Speed CRHHT80 High T 940-3.00 7.00 55/F 112M 62 CRHHT80 Low T 720-3.00 4.10 55/F 112M 56 Page 18

Vertical discharge centrifugal roof fans CRHT F400 Certificate 0370-CPR-2090 Description The CRHT range are centrifugal roof fans for direct or duct application suitable for high temperature smoke extraction. The main feature of this range is the vertical exhaust cowl which guarantees optimum safety in the event of a fire. It provides fast and effective toxic fume extraction, leading to safer escape routes, easier access for the emergency teams, and minimizes the effects of fire on the building structure. The range is suitable for running at a temperature of +150 C and is CE certified F400 according to EN12101-3 by the Applus laboratories in Barcelona. Dimensions (mm) Construction Base frame in galvanized steel sheet protected with epoxy finish. Protection guard in drawn steel rod protected against the atmosphere and manufactured according to UNI 10615:1997. Backward curved impeller in galvanized steel sheet, with high efficiency and low noise level, designed to withstand high temperatures and to ensure the proper cooling of the motor in emergency mode. Statically and dynamically balanced according to ISO 1940. Directly coupled to flanged motor. Upper cover and vertical exhaust cowl made of galvanized steel sheet protected with epoxy finish grey RAL 7001. or Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Accessories Counter base for secure fixing. let protection guard Also available High temperature service switch High temperature terminal box Model AxA B C D E ØH KG CRHT 350 800 590 38 500 450 270 45 CRHT 400 950 640 38 650 600 296 65 CRHT 450 950 640 38 650 600 296 65 CRHT 500 1200 720 38 760 710 327 102 CRHT 560 1200 720 38 760 710 370 110 CRHT 630 1480 890 38 930 870 430 165 CRHT 710 1480 930 38 930 870 480 180 CRHT 750 1480 930 38 930 870 480 210 CRHT 800 1480 960 38 930 870 530 240 Page 19

Vertical discharge centrifugal roof fans CRHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 6 m Phase Poles Amps IP/CL CRHT354 M 4 0.25 2.35 55/F 71 45 CRHT354 T 4 0.25 0.86 55/F 71 49 Phase Poles Amps IP/CL CRHT404 M 4 0.55 4.75 55/F 80 48 CRHT404 T 4 0.55 1.60 55/F 80 51 Phase Poles Amps IP/CL CRHT454 M 4 0.75 5.60 55/F 80 56 CRHT454 T 4 0.75 2.20 55/F 80 55 CRHT456 M 6 0.37 3.00 55/F 80 47 CRHT456 T 6 0.37 1.20 55/F 80 39 Page 20 Phase Poles Amps IP/CL CRHT504 T 4 1.10 2.80 55/F 90 60 CRHT506 T 6 0.37 1.20 55/F 80 49

Vertical discharge centrifugal roof fans CRHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 6 m Phase Poles IP/CL Amps CRHT566 T 6 0.55 1.80 55/F 80 55 Phase Poles IP/CL Amps CRHT636 T 6 1.10 3.40 55/F 90 59 Phase Poles IP/CL Amps CRHT716 T 6 1.50 4.30 55/F 100 62 Phase Poles IP/CL Amps CRHT756 T 6 2.20 5.00 55/F 112 65 Page 21

Vertical discharge centrifugal roof fans CRHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 6 m Phase Poles IP/CL Amps CRHT806 T 6 3.00 7.20 55/F 132 67 Page 22

Backward curved centrifugal fans PRQ/HT F400 Certificate 0370-CPR-1998 Description The PRQ/HT range are backward curved centrifugal fans suitable for high temperature smoke extraction. The main characteristic of the PRQ range is the quadrangular construction, which allows the fan to be installed in any of four orientations (0-90 -180-270 ). The dimensions are reduced due to the absence of a motor support. The range is suitable for running at a temperature of +100 C and is CE certified to F400 by the Applus laboratories in Barcelona. to EN 12101-3. Construction Spiral casing with quadrangular frame, manufactured in galvanized steel sheet protected against atmospheric agents. Single inlet, backward curved impeller with high efficiency, manufactured in galvanized steel sheet and steel hub. let/outlet made according to UNI EN ISO 13351 Execution 5 (impeller directly coupled to flanged motor), rotation RD. or Asynchronous three-phase motor manufactured according to interna tional standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Electric supply: 400V/50HZ three phase. Accessories let/outlet flexible connectors. let and outlet protection guard manufactured according to UNI 12499 norm and protected against atmospheric agents. let/outlet counterflange. Antivibration supports. Transformer or inverter speed controllers. Orientation Page 23

Backward curved centrifugal fans PRQ/HT Dimensions (mm) Model A A1 B B1 C D E F G H H1 let I L M N kg PRQ/HT350 620 520 650 55 295 325 370 280 177 270 450 270 450 8 M8 35 PRQ/HT400 680 580 790 690 305 375 440 350 277 320 520 296 500 8 M8 45 PRQ/HT450 740 640 880 780 305 435 490 390 255 320 520 296 500 8 M8 50 PRQ/HT500 820 660 960 800 340 480 540 420 265 400 620 327 560 12 M8 75 PRQ/HT560 890 730 1040 880 370 520 600 440 300 400 585 370 620 12 M8 80 PRQ/HT630 910 750 1100 940 410 500 650 450 320 455 675 430 690 12 M8 100 Model Outlet a b n1xc d n2xe f g h l m PRQ/HT350 315 200 2x125 353 1x100 238 385 270 14 10 PRQ/HT400 355 250 2x125 393 1x125 288 425 320 14 10 PRQ/HT450 400 250 2x125 438 1x125 288 470 320 14 10 PRQ/HT500 450 300 3x125 514 2x125 364 550 400 18 12 PRQ/HT560 500 300 3x125 564 2x125 364 600 400 18 12 PRQ/HT630 560 355 4x125 624 2x125 419 660 455 20 12 Page 24

Backward curved centrifugal fans PRQ/HT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 1.5 m Phase Speed PRQ/HT 35 High T 1350-0.26 0.96 55/F 71 69 PRQ/HT 35 Low T 980-0.26 0.55 55/F 71 69 Phase Speed PRQ/HT 40 High T 1400-0.55 1.06 55/F 80 70 PRQ/HT 40 Low T 980-0.55 0.90 55/F 80 59 Phase Speed PRQ/HT 45 High T 1400-0.75 2.20 55/F 80 72 PRQ/HT 45 Low T 980-0.75 1.30 55/F 80 61 Phase Speed PRQ/HT 50 High T 1400-1.10 2.80 55/F 90S 73 PRQ/HT 50 Low T 980-1.10 1.60 55/F 90S 63 Page 25

Backward curved centrifugal fans PRQ/HT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 1.5 m Phase Speed PRQ/HT 56 High T 900-0.55 2.00 55/F 80 70 PRQ/HT 56 Low T 730-0.55 1.30 55/F 80 64 Phase Speed PRQ/HT 63 High T 900-1.10 3.40 55/F 90L 73 PRQ/HT 63 Low T 730-1.10 3.40 55/F 90L 65 Page 26

Belt driven double inlet box fans CBBHT F400 Description The belt driven double inlet CBBHT fans are designed for installation into industrial buildings where there is a requirement for the extraction of fire smoke. They are suitable for continuous operation in clean air and non dusty smoke to a maximum temperature of +200 C. emergency smoke extract situations the range will operate at +400 C for 120 minutes and is CE certified to F400 in compliance with EN12101-3 by the Applus laboratories in Barcelona. Dimensions (mm) Construction Dismountable cabinet in galvanized steel sheet. Double inlet impeller with forward curved blades in galvanized steel sheet. Belt coupling with self aligning supports, outside the airflow. Height adjustable motor support plate for the tensioning of the belt. Belt coupling protected by a guard in galvanized sheet. or Asynchronous three-phase motor, IP55 mechanical protection, insula tion class F, single or double polarity, suitable for S1 service, mounting type B3, construction according to IEC/EEC (UNEL MEC). Arrangement 9: belt coupling with motor placed on the upper panel. Arrangement 12: belt coupling with motor placed aside on a common base plate (only for motors above 7.5). Also available Model with 2 Pole motor Model A B H C D E ØF G I L M Q Kg min max CBBHT 250 650 600 600 300 300 158 405 100 370 230 300 350 75-90 CBBHT 300 730 700 680 350 350 173 500 100 425 255 340 410 100-135 CBBHT 350 860 800 750 400 400 173 610 100 470 280 375 410 145-270 CBBHT 400 1030 900 840 450 450 173 650 100 535 305 420 420 210-330 CBBHT 450 1200 1000 960 500 500 173 750 100 630 330 480 420 250-500 CBBHT 500 1250 1200 1020 600 600 173 800 100 640 380 510 420 310-590 Page 27

Belt driven double inlet box fans CBBHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 1.5 m Phase Speed Amps m3 /hr IP/CL CBBHT 254/A T 1800 2.20 4.90 5700 55/F 100 66 CBBHT 254/B T 1600 1.50 3.45 5050 55/F 90 64 CBBHT 254/C T 1400 1.10 2.64 4300 55/F 90 61 CBBHT 254/D T 1200 0.75 1.93 3700 55/F 80 57 CBBHT 254/E T 1000 0.37 1.11 3150 55/F 71 53 Phase Speed Amps m3 /hr IP/CL CBBHT 304/A T 1800 5.50 11.0 9700 55/F 132 72 CBBHT 304/B T 1600 4.00 8.26 8700 55/F 112 69 CBBHT 304/C T 1400 3.00 6.47 7400 55/F 100 67 CBBHT 304/D T 1200 2.20 4.90 6300 55/F 100 63 CBBHT 304/E T 1000 1.10 2.64 5300 55/F 90 59 Page 28

Belt driven double inlet box fans CBBHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 1.5 m Phase Speed Amps m3 /hr IP/CL CBBHT 354/A T 1600 11.00 21.30 13600 55/F 160 74 CBBHT 354/B T 1400 5.50 11.00 12000 55/F 132 71 CBBHT 354/C T 1200 4.00 8.26 10100 55/F 112 68 CBBHT 354/D T 1000 2.20 4.90 8250 55/F 100 64 CBBHT 354/E T 800 1.10 2.64 6800 55/F 90 59 Phase Speed Amps m3 /hr IP/CL CBBHT 404/A T 1400 11.00 21.30 18200 55/F 160 74 CBBHT 404/B T 1200 7.50 14.60 16000 55/F 132 72 CBBHT 404/C T 1000 4.00 8.26 13000 55/F 112 68 CBBHT 404/D T 800 2.20 4.90 10100 55/F 100 63 Page 29

Belt driven double inlet box fans CBBHT Technical Data Frequency 50Hz: Air temperature 15 C: Barometric pressure 760 mm Hg: Air specific weight 1.22 Kg/m 3 : sound pressure level measured at 1.5 m Phase Speed Amps m3 /hr IP/CL CBBHT 454/A T 1400 22.00 38.80 25500 55/F 180 74 CBBHT 454/B T 1200 15.00 27.70 22000 55/F 160 72 CBBHT 454/C T 1000 7.50 14.60 18000 55/F 132 68 CBBHT 454/D T 800 4.00 8.26 14500 55/F 112 63 CBBHT 454/E T 600 1.50 3.45 11000 55/F 90 60 Phase Speed Amps m3 /hr IP/CL CBBHT 504/A T 1400 30.00 53.00 35000 55/F 225 82 CBBHT 504/B T 1200 22.00 38.80 30000 55/F 180 78 CBBHT 504/C T 1000 15.00 27.70 25000 55/F 160 74 CBBHT 504/D T 800 7.50 14.60 20000 55/F 132 70 CBBHT 504/E T 600 3.00 6.47 15000 55/F 100 64 Page 30

Car Park Ventilation Principles and Solutions Basic Principle The ventilation of enclosed or underground car parks demands certain key fundamentals: the removal of pollutants emitted by vehicles the control and removal of hot fumes and gases in the event of a fire the effective protection of escape routes (which also provides easier access for Emergency Services) Special Technology recent years, the jet or induction fan technology has become the new standard for normal ventilation and for smoke extraction in case of fire in enclosed car parks. This technology represents the most innovative and cost-effective alternative to traditional ducted mechanical extraction systems. The careful management of the project in all its development stages (requireing the use of fluid dynamics calculation programs) ensures that the system will operate efficiently and correctly. Car park ventilation systems provide either normal ventilation to remove fumes and other pollutants, or can extract smoke at very high temperatures should there be a fire in an underground car park. Or they can be combination of both, i.e. dual purpose fans. tegrated Systems A fully integrated car park ventilation system requires five key elements: suitably positioned carbon monoxide (CO) and heat/smoke sensors a system control panel CFD (computation fluid dynamics) analysis accurate selection and positioning of smoke control fans contaminated air removal system. LCA-JT/HT or JTCHT CAHT Normal Ventilation The axial impulse or centrifugal induction fans efficiently ventilate both bottom and top layers avoiding the creation of areas where air could get trapped. The fans are only operated when the CO (carbon monoxide) detectors show a level of pollution higher than the pre-set level (variable according to requirements). Normal Ventilation Emergency Smoke Extract A fire starts The ventilation system starts to operate LCAHT LCA-JT/HT - axial impulse fans for car park ventilation JTCHT - centrifugal induction fans for car park ventilation The system is based on placing a set of axial impulse fans or centrifugal induction fans throughout the parking area, which operate in a similar way to a ducted system. When installed on the ceiling, they transfer the smoke-laden air from the upper to the lower layers, creating a continuous air flow, inducing cleaner, cooler air which drives the smoke to the extraction and removal points. The system is completed by natural or mechanical air inlets and exhaust fans. The smoke is extracted Page 31

Car Park Ventilation Principles and Solutions Advantages A smoke and fume extract system based on impulse axial or centrifugal induction fans can easily be split into different control areas. This ensures maximum extraction of smoke from the area where fire has broken out and increased the air pressure where the fire needs to be extinguished. Pressure is lowered at the site of the fire, stopping fumes spreading, and reducing the temperature of the fire affected area. Compared to a ducted ventilation system, this innovative system ensures multiple benefits in terms of the low cost and efficiency associated with its design, installation, operation and usage. Design The compact size of the fans and the flexibility of installation allows the optimisation of space. Design time is saved since there is no need for a complex ducted system. The system effectiveness can be pre dicted with CFD (fluid dynamics cal culation) modelling. It allows the project designer to benefit from a better pre-sales customer service. The project can be financially assessed within 24 hours to make sure that the final costs are in line with ex pected costs. stallation The fans are easy to install, ensuring time saving in terms of hours of work. There is no need for an expensive and complex duct and grille systems. The smaller sizes of the fans adds to the ease of installation of other services (sprinklers, lighting etc); The fans and systems are easy to maintain and service. Operation Major savings in running costs are ensured by the system's distinctive features: The ventilation system can be fully or partly operational. Carbon monoxide (CO) detectors and the smoke sensors, ensure that only those fans operate which are located in areas where pollution levels are exceeded or where a fire has started. Less total power required as the ac curate design ensures the optimal size of the ventilation system. The inlet and exhaust fans can be smaller as the jet or induction fans generate a negligible pressure drop compared to ducted systems. Use Better quality of breathable air: this system creates a continuous air flow mixing different layers of air and avoiding areas of trapped air. Optimised safety in the event of a fire: fast and effective toxic fume extraction, leading to safer escape routes, easier access for emergency services, promoting people safety and minimising the effects of fire on the building structure. From Design to Customer Service Designing a car park ventilation system requires the application of CFD. The high complexity and reliability of fluid dynam ics calculations are well established. During this crucial design stage, we can offer a full CFD analysis and valuable engineering support. How it Works CFD calculation is essential to ensure that all areas of the car park are correctly ventilated and, in the event of fire, fume extraction is optimised. CFD analysis is also necessary to calculate accurately the size of the ventilation system required together with the correct positioning of the jet or induction fans and of the other exhaust and/or inlet fans. This calculation is based on computer simulation and combines variables such as the required number of air changes/hour (as required by regulation), air volume and direction, and the structural features of each car park (in a 3D model). The data generates dynamic scenarios based on air speed profiles, particle movement and airflow distribution. This allows a customised ventilation scheme to be designed. This methodical approach allows not only prediction of the system effectiveness, but also ensures the most cost-effective solution. Page 32

Car Park Ventilation Principles and Solutions Calculation Set-up and Scenario Development Account must be taken of boundary conditions and initial conditions such as external pressure and outside air temperature. Structural parameters (light wells, access ramps etc) also need to be specified, together with operating conditions (material definition, assignment of air performance required). Mesh definition is also necessary (ie the quantity of primary volumes the model must be split into). Data processing and assessment of each scenario can be made by changing the type, quantity and position of the fans. Final Scenario During this last stage, the computer programme analyses the system effectiveness. Analysing Results and Developing a Balanced Solution Data can be analysed by checking the air speed inside each section of the car park. The graph shown below represents the average air speed on a sectional floor. Page 33

Accessories EXTLCA Extension for Cased Axial Fans A A1 ØB ØC ØD E ØF kg EXTLCA400 200 430 400 450 496 8 12 6 EXTLCA450 200 430 450 500 546 8 12 7 EXTLCA500 200 450 500 560 598 12 12 8 EXTLCA560 200 450 560 620 658 12 12 9 EXTLCA630 240 490 630 690 730 12 12 11 EXTLCA710 280 530 710 770 810 16 12 13 EXTLCA800 340 590 800 860 910 16 12 20 EXTLCA900 410 690 900 970 1030 16 16 31 EXTLCA1000 410 760 1000 1070 1130 16 16 39 Converts short cased axial fans into long cased versions. Impellers and motors are completely protected inside the casing. Manufactured in steel sheet. Fixing flanges to UNI ISO6580-EUROVENT standard. Protected against atmospheric agents with epoxy paint. Complete with inspection porthole and holes for cable entry. IC let Cones for Cased Axial Fans Model No A B C D E F G H I L kg IC310 175 446 355 395 8 10 8 10 307 395 4.5 IC350 175 496 395 450 8 12 8 10 357 446 5.0 IC400 175 546 450 500 8 12 8 12 407 496 5.6 IC450 175 598 500 560 12 12 8 12 457 546 6.3 IC500 190 658 560 620 12 12 12 12 507 598 8.5 IC560 190 730 620 690 12 12 12 12 567 658 8.5 IC630 190 810 690 770 16 12 12 12 637 730 9.8 IC710 230 910 770 860 16 12 16 12 708 810 12.4 IC800 250 1025 860 970 16 16 16 12 808 910 15.2 IC900 300 1125 970 1070 16 16 16 16 910 1030 29.4 IC1000 300 1245 1070 1190 20 16 16 16 1010 1130 33.3 IC1120 300 1380 1190 1320 20 16 20 16 1130 1250 37.3 IC1250 300 1525 1320 1470 20 16 20 16 1260 1380 42.5 IC1400 300 1735 1470 1630 24 18 20 16 1415 1540 49.8 IC1600 300 1935 1680 1880 24 18 24 18 1615 1750 57.2 It allows a higher fan efficiency where installation is with inlet or outlet not ducted. Manufactured in steel sheet, with one flange according to UNI ISO6580 EUROVENT to be fitted to the fan, and an aerodynamically shaped bell mouth, with fixing holes for a protection guard (of one size bigger, example IC710 71 + PG800). Protected against atmospheric agents with epoxy paint. Page 34

Accessories FLCHT High Temperature Flexible Connector for Cased Axial Fans A ØB ØC ØD E ØF kg FCLHT400 200 400 450 496 8 12 7 FCLHT450 200 450 500 546 8 12 8 FCLHT500 200 500 560 598 12 12 9 FCLHT560 200 560 620 658 12 12 10 FCLHT630 200 630 690 730 12 12 11 FCLHT710 200 710 770 810 16 12 13 FCLHT800 200 800 860 910 16 12 21 FCLHT900 200 900 970 1030 16 16 23 FCLHT1000 200 1000 1070 1130 16 16 26 FCLHT1120 200 1120 1190 1250 20 16 29 FCLHT1250 200 1250 1320 1380 20 16 32 FCLHT1400 200 1415 1470 1540 20 16 38 FCLHT1600 200 1615 1680 1730 24 18 44 It reduces the incidence of vibration along the duct system. Manufactured with two flanges in steel sheet, according to UNI ISO6580 EUROVENT standard for fixing to the fan and to the duct, and a strong flexible fabric joint. Suitable for high temperature operation. Components in steel sheet protected against atmospheric agents by epoxy paint. PG Protection Guard for Cased Axial Fans ØA kg PG400 450 0.8 PG450 500 1.0 PG500 560 1.3 PG560 620 1.6 PG630 690 1.9 PG710 770 2.2 PG800 860 3.0 PG900 970 3.4 PG1000 1070 3.5 PG1120 1190 4.0 PG1250 1320 4.5 PG1400 1470 6.5 PG1600 1680 8.5 They prevent contact with moving parts of the fan. Manufactured in steel rod according to UNI 10615 standard and protected against atmospheric agents. They are flat for fitting on the impeller side of the fan. Page 35

Accessories MF Mounting Feet for Cased Axial Fans A B C D ØE kg MF400 400 300 320 2 10 1.0 MF450 450 350 350 2 10 1.5 MF500 500 400 380 2 10 2.0 MF560 560 460 410 2 10 2.5 MF630 630 480 450 2 10 2.8 MF710 710 550 490 2 10 3.0 MF800 800 660 540 3 14 3.8 MF900 900 760 600 3 14 4.5 MF1000 1000 860 640 3 14 4.8 MF1120 1120 820 710 3 14 6.8 MF1250 1250 950 770 3 14 7.8 MF1400 1400 1100 850 3 14 11.0 MF1600 1600 1300 960 3 16 21.5 For fastening the fan to the floor or to the ceiling. Manufactured in steel sheet and protected against atmospheric agents by epoxy paint. SPIG Connecting Flange for Cased Axial Fans ØA ØB C ØD kg SPIG400 400 450 8 12 1.7 SPIG450 450 500 8 12 2.0 SPIG500 500 560 12 12 2.2 SPIG560 560 620 12 12 2.5 SPIG630 630 690 12 12 2.9 SPIG710 710 770 16 12 3.3 SPIG800 800 860 16 12 3.8 SPIG900 900 970 16 16 4.2 SPIG1000 1000 1070 16 16 5.0 SPIG1120 1120 1190 20 16 5.8 SPIG1250 1250 1320 20 16 6.5 SPIG1400 1415 1470 20 16 10.0 SPIG1600 1615 1680 24 16 12.0 Connecting flange with 80 mm of round duct. It is used for easier connection between the fan and the duct. Page 36

Accessories LCSP and LCS Silencers with and without pod for Cased Axial Fans ØB Øb ØC D ØE ØF LCSP/LCS400 540 400 450 8 M10 195 LCSP/LCS450 610 450 500 8 M10 195 LCSP/LCS500 660 500 560 12 M10 250 LCSP/LCS560 720 560 620 12 M10 250 LCSP/LCS630 790 630 690 12 M10 300 LCSP/LCS710 870 710 770 16 M10 380 LCSP/LCS800 1000 800 860 16 M10 380 LCSP/LCS900 1100 900 970 16 M12 380 LCSP/LCS1000 1200 1000 1070 16 M12 655 LCSP/LCS1120 1320 1120 1190 20 M12 655 LCSP/LCS1250 1450 1250 1320 20 M12 655 No LCSP400 1 LCSP450 2 LCSP500 3 LCSP560 4 LCSP630 5 LCSP710 6 LCSP800 7 LCSP900 8 LCSP1000 9 LCSP1120 10 LCSP1250 11 Pressure Loss on Silencers with Pod A1Ø kg A1.5Ø kg A2Ø Kg LCSP400 400 14 600 21 800 26 LCSP450 450 17 675 24 900 29 LCSP500 500 23 750 32 1000 39 LCSP560 560 28 840 37 1120 44 LCSP630 630 32 945 44 1260 55 LCSP710 710 44 1065 62 1420 78 LCSP800 800 56 1200 79 1600 101 LCSP900 900 130 1350 153 1800 175 LCSP1000 1000 143 1500 180 2000 216 LCSP1120 1120 165 1680 202 2240 238 LCSP1250 1250 193 1875 240 2500 282 A1Ø kg A1.5Ø kg A2Ø Kg LCS400 400 12 600 17 800 21 LCS450 450 15 675 20 900 24 LCS500 500 18 750 25 1000 32 LCS560 560 21 840 28 1120 35 LCS630 630 24 945 33 1260 43 LCS710 710 35 1065 49 1420 63 LCS800 800 43 1200 61 1600 79 LCS900 900 70 1350 94 1800 112 LCS1000 1000 113 1500 137 2000 161 LCS1120 1120 130 1680 154 2240 178 LCS1250 1250 152 1875 185 2500 213 The cylindrical silencers are available in two versions, with pod (LCSP) and without pod (LCS). The presence of the pod gives higher noise attenuation, but creates an additional pressure drop in the system. Both the versions can be fixed to the corresponding flange of the fan in inlet and outlet. The LCS range does not create additional loss, but the LCSP versions do. Silencers can be in lengths equal to 1, 1.5 or 2 times the diameter (b). The silencers are manufactured completely in galvanized steel. The internal part and the pod are made in perforated sheet, to allow effective sound absorption of the acoustic lining in mineral wool. The working temperature is from -40 C and +150 C. Page 37

Accessories RTVJ/LCAHT Roof Terminal for Duct Axial Fans A B C i kg RTVJ/LCAHT800 1280 750 1250 50 80 RTVJ/LCAHT900 1280 750 1250 50 80 RTVJ/LCAHT1000 1580 600 1500 60 100 RTVJ/LCAHT1120 1580 600 1500 60 100 RTVJ/LCAHT1250 1840 685 1800 85 120 RTVJ/LCAHT1400 1840 685 1800 85 120 Outer conveyor for vertical exhaust with epoxy painted steel sheet base and with vertical panels in galvanized steel sheet. The kit includes: Double wing aluminium gravity shutters, acoustically lined. Support plate in epoxy painted steel sheet. Weatherproof outlet protection guard according to norm UNI 10615 CB Counter Base for CRHT and CRRHT fans Model No A B C ØD kg CB400 630 600 30 M8x30 3.2 CB450 630 600 30 M8x30 3.2 CB500 740 710 30 M10x40 3.6 CB560 740 710 30 M10x40 3.6 CB630 900 870 30 M10x40 4.0 CB710 900 870 30 M10x40 4.0 CB750 900 870 30 M10x40 4.0 CB800 900 870 30 M10x40 4.0 The counter base ensures an effective anchorage to the concrete support, through the fixing of four metal strips suitably designed. It is made in solid steel with fan base fixings. Page 38

Accessories SPIG-PRQ/HT Connecting Flange for PRQ/HT A B n1xc D n2xe F G H L M Sp kg SPIG-PRQ/HT350 315 200 2x125 353 1x100 238 385 270 14 10 15/10 0.47 SPIG-PRQ/HT400 355 250 2x125 393 1x125 288 425 320 14 10 15/10 0.55 SPIG-PRQ/HT450 400 250 2x125 438 1x125 288 470 320 14 10 15/10 0.58 SPIG-PRQ/HT500 450 300 3x125 514 2x125 364 550 400 18 12 20/10 1.30 SPIG-PRQ/HT560 500 300 3x125 564 2x125 364 600 400 18 12 20/10 1.38 SPIG-PRQ/HT630 560 355 4x125 624 2x125 419 660 455 20 12 20/10 1.56 G-PRQ/HT Outlet Guard for PRQ/HT A B n1xc D n2xe F G H L M kg G-PRQ/HT350 315 200 2x125 353 1x100 238 385 270 14 10 3.5 G-PRQ/HT400 355 250 2x125 393 1x125 288 425 320 14 10 4.0 G-PRQ/HT450 400 250 2x125 438 1x125 288 470 320 14 10 4.5 G-PRQ/HT500 450 300 3x125 514 2x125 364 550 400 18 12 5.0 G-PRQ/HT560 500 300 3x125 564 2x125 364 600 400 18 12 5.5 G-PRQ/HT630 560 355 4x125 624 2x125 419 660 455 20 12 6.0 PG-PRQ/HT Outlet Protection Guard for PRQ/HT A B n1xc D n2xe F L M kg PG-PRQ/HT350 385 270 2x125 353 1x100 238 14 10 15/10 0.49 PG-PRQ/HT400 425 320 2x125 393 1x125 288 14 10 15/10 0.58 PG-PRQ/HT450 470 320 2x125 438 1x125 288 14 10 15/10 0.61 PG-PRQ/HT500 550 400 3x125 514 2x125 364 18 12 20/10 1.33 PG-PRQ/HT560 600 400 3x125 564 2x125 364 18 12 20/10 1.41 PG-PRQ/HT630 660 455 4x125 624 2x125 419 20 12 20/10 1.59 Page 39

AIR VENT TECHNOLOGY LTD 56 Reith Way Portway dustrial Estate Andover Hampshire SP10 3TY Tel: +44(0)1264 356415 Fax: +44(0)1264 337854 Certificate No: GB9455 Part of the Vectaire Group of Companies Air Vent Technology reserves the right to alter specifications as part of its policy of continuous development Aug2015/ESE/02 E & O.E