Direct solenoid and solenoid pilot operated valves

Similar documents
Direct solenoid and solenoid pilot operated valves

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Bullet Valve (BV) Series

Direct solenoid and solenoid pilot operated valves

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

Bullet Valve (BV) Series

Direct solenoid and solenoid pilot operated valves

Specifications 54 Series Valve

32, CONTENTS SMALL LARGE

42 Series MAConnect TM. 42 Series Plug-In Manifold

92 Series MAConnect with Sub D

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

82 Series MAConnect with Sub-D

MAC VALVES, INC. Rev. T

MAC Pulse Valve PV03 Series

MAC Pulse Valve PV06 Series

MAC VALVES EUROPE, INC.

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

Section 2 Proportional Quick Exhaust

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

LYCOMING CYLINDER PRICING

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

Action Automation & Controls, Inc.

ISO 5599/ Series Technical and Operating Data

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Balanced Valve Series Multi-Purpose Direct-Acting Solenoid Valves

2012 Series Solenoid Pilot Actuated Valves

Introduction Section 1 Section 2 Section 3

Electrical Interface Dimensional Drawings Connector Kits

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

3 Port Solenoid Valve Direct Operated Poppet Type

Series 581 ISO Pneumatic Directional Control Valves

SOLENOID VALVES AND PNEUMATIC VALVES

2035 Series Solenoid Pilot Actuated Valves

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

INSTRUMENT PANEL CLUSTERS

CUSTOM ADD-ONS FOR ENGLISH UNITS

EAGLE SERIES VALVES E3 AND E4 SERIES. A Solenoid coil is available in AC or. B Manual override plunger provides. C Valve body is tapped #10-32 and may

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Contact Air Incorporated for further assistance. Ph:

KRONES DIRECT REPLACEMENTS

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

Pilot Operated 2 Port Solenoid Valve for Dry Air

Miniature Multimedia Valves

Sub-Base Mounted Valves to ISO 5599/2 Fielbus Electronics - 239

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

S: With magnet. Bore x stroke (basic type) Cushion P: pneumatic adjustable

Chapter 6: Check Valves

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

Miniature Pneumatic Solenoid Valve

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD.

Directional Seat Valve Series D4S (Denison)

Chapter 10: Valves for Pipe Mounting

Valve Manifolds. Series Fielbus Electronics - 51

Series PD directly operated solenoid valves

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Port Flow Rate/ Function Series Actuators Page Number Size Factor

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

MOUNTING BRACKETS. Dimensional Drawing - Mounting Options

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Solenoid valves "OPTYMA32-S" General. Series 2200

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

Solenoid valves "OPTYMA32-S" General. Series 2200

2/2 or 3/2 way direct acting rocker solenoid valve

Double Pump Operating Specifications

NEW! MAXIMATIC SOLENOID VALVES

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Dimensional Drawing - Mounting Options

Field Variable Area Flowmeters BFP Global Purgemaster

F5 Valve F6 Valve F7 Valve

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Technical Bulletin. MAC Valves, Inc., is pleased to announce. Introduction - Plunger up / Plunger Cooling / Counterblow Solutions

3 Port Solenoid Valve

FITTINGS CHEST FITTINGS CHEST. Get organized with the Pneuforce Fittings Chest!

Guided compact cylinder General

Pilot Operated 2 Port Solenoid Valve for Dry Air

Transcription:

Direct solenoid and solenoid pilot operated valves 8mm valve Series 33 Function Port size Flow (Max) Individual mounting Series 3/ NC M3 0.08 C v Inline OPERATIONAL BENEFITS 1. 8mm valve direct solenoid operated.. Balanced poppet, immune to pressure variations. 3. Short stroke with high flow. 4. Patented solenoid develops high shifting forces. 5. Low wattage solenoids. 6. Powerful return spring. 7. Extremely fast response times. HOW TO ORDER Port size M3 ** For use with solenoids above 4.0 W - MOD number required. (Consult factory) SOLENOID OPERATOR N.C. Only 33A-AAB-RXXX-XXX R XXX-XXX XX Voltage X Lead wire length X Manual operator XX DA DB DC DF DG DH DJ DM 4 VDC (0.5W) 4 VDC (1.0W) 4 VDC (1.8W) 4 VDC (4.0W) 1 VDC (0.5W) 1 VDC (1.0W) 1 VDC (1.8W) 1 VDC (4.0W) * Other options available, see page 31. 0 No Lead wire* A 18 B 4 C 36 D 48 E 7 * Not available for flying leads connectors Washdown capability is possible for the B and R type electrical connectors. Consult factory for ordering information. 0 No manual operator 1 Non-locking recessed 3 Non-locking extended Patents and patents pending N.C. Only ** 33A-BAB-RXXX-XXX BA BB BC BD RA RB RC RD TA TB TC TD Electrical connection Flying leads Flying leads w/led Flying leads w/mov Flying leads w/led & MOV Mini JAC Solenoid plug-in Mini JAC Solenoid plug-in w/led Mini JAC Solenoid plug-in w/mov Mini JAC Solenoid plug-in w/led & MOV JST Solenoid plug-in JST Solenoid plug-in w/led JST Solenoid plug-in w/mov JST Solenoid plug-in w/led & MOV 33 34 36 3 37 38 5 67 69 44 46 4 47 48P 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 15 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 33 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40µ 0 F to 10 F (-18 C to +50 C) 4W: (Cv.08) - 3W: (Cv.06) -.5W: (Cv.06) - 1.8W: (Cv.055) - 1.0W: (Cv.030) - 0.5W: (Cv.00) Class A wire (#6 AWG x18), continuous duty -15% to +10% of nominal voltage 4.0W - 3.0W -.5W - 1.8W - 1.0W - 0.5W DIMENSIONS 35,3 Dimensions shown are metric (mm) 10,6 4,5 Shown with JST Connector 4,6 4,0 16,0 13,5 1,30 0, 3,4 8,0 Ø, Thru Typ () 8,00 4,00 7,5 16 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 34 Function Port size Flow (Max) Individual mounting Series 3/ NO-NC, / NO-NC M5, # 10-3 0.1 C v Inline OPERATIONAL BENEFITS 1. 10 mm valve, direct solenoid operated.. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. Patented solenoid develops high shifting forces. 5. Powerful return spring. 6. Manual operator standard on all valves. HOW TO ORDER Port size M5 # 10-3 SOLENOID OPERATOR Universal valve 34C-ABA-G XXX-XXX 34C-AAA-G XXX-XXX G XXX-XXX * XX Voltage X Wire length X Manual operator XX AA DC DD DF 10 VAC (.5W) 4 VDC (1.8W) 4 VDC (.5W) 4 VDC (4.0W) Note : AC voltage requires connector with rectifier. * Other options available, see page 311. A 18 B 4 C 36 Washdown capability is possible for the G type electrical connectors. Consult factory for ordering information. 1 Non-locking recessed 3 Non-locking extended NC only valve 34C-ABB-G XXX-XXX 34C-AAB-G XXX-XXX BA BT GA GB GC GD GE GF GG GH KA KC KT Electrical connection Flying leads Flying leads with light w/diode w/mov w/led w/diode & LED w/mov & LED w/rectifier w/rectifier & LED Plug-in wire assembly Plug-in wire assembly with rectifier and light Plug-in wire assembly with light 33 34 36 3 37 38 5 67 69 44 46 4 47 48P 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 19 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 34 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 4 W : (0.1 C v ).5 W : (0.10 C v ) 1.8 W : (0.06 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 4 W.5 W 1.8 W Energize : 3.4 ms De-energize : 1.5 ms DIMENSIONS 31,5 3,3 DIA. MTG. HOLES () C L C L C L Dimensions shown are metric (mm) 50, 9,3 0,0 1,0 4,0 1 4,5 14,5 3 5,3 0,8 5,0 7,0 10,0 10,0 0,0 0 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series 3/ 1/8 0.3 C v Inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Universal valve NC only valve 33 34 36 3 37 38 5 67 69 44 1/8 NPTF 36A-AAA-J XXX-XXX 36A-AAB-J XXX-XXX 46 SOLENOID OPERATOR J XXX-XXX * (-G) Add "G" for ground XX Voltage X Lead wire length X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) A 18 B 4 C 36 * Other options available, see page 317. Note : - AC voltage requires connector with rectifier. - With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number. 1 Non-locking recessed Locking recessed BA GA GB GD GG Electrical connection Flying leads with diode with light with rectifier 4 47 48P 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 3 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8 Watt: (0.15 C v ),.4 Watt: (0.15 C v ), 5.4 Watt: (0.30 C v ) Class A wire (# AWG x 1), continuous duty -15% to +10% of nominal voltage Consult factory 5.4 W.4 W 1.8 W Option : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 3.3 4.3 58. 16.6 13.1 8.0 3.3 10.1 8. 4.5 1.5 Ø 3.4 15.3 30.5 4 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series 3/ 1/8" # 10-3 0.3 C v Stacking OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size 1/8 NPTF # 10-3 SOLENOID OPERATOR NC only stacking CYL INEXH 36A-SAB-J XXX-XXX 36A-SBB-J XXX-XXX NC stacking Universal poppet CYL INEXH 36A-SAC-J XXX-XXX 36A-SBC-J XXX-XXX NO stacking Universal poppet CYL IN EXH 36A-SAD-J XXX-XXX 36A-SBD-J XXX-XXX J XXX-XXX * (-G) Add "G" for ground XX Voltage X Lead wire length X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) A 18 B 4 C 36 * Other options available, see page 317. Note : - AC voltage requires connector with rectifier. - With the MAC JAC, washdown capability is possible. Consult factory for washdown modification number. End plate kit required (port size 1/4") : M-36001-01. BODY TYPE OPTIONS 36A-SAB-JXXX-XXX S Stacking body T Stacking body with bottom inlet 1 Non-locking recessed Locking recessed BA GA GB GD GG Electrical connection Flying leads with diode with light with rectifier 33 34 36 3 37 38 5 67 69 44 46 4 47 48P 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 5 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8 Watt: (0.15 C v ),.4 Watt: (0.15 C v ), 5.4 Watt: (0.30 C v ) Class A wire (# AWG x 1), continuous duty -15% to +10% of nominal voltage Consult factory 5.4 W.4 W 1.8 W Option : Spare parts : BSPP threads Inlet & exhaust isolator plate : N-36001 Inlet isolator : N-3600 Exhaust isolator : N-36003 Tie rod (x) : 79411 DIMENSIONS 15.0 16.5 8.3 15.0 14.1 Dimensions shown are metric (mm) Note: Isolator adds.5 mm to length of stack. 59. 51.3 35.. 9.0 5.0 4.7 1/4" COMMONS 9.3 86.0 6 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series 3/ 1/8" - 5/3 Pressed-in 0.3 C v tube receptacle Manifold base plug-in OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Valve less base 1/8 NPTF 5/3 tube receptacle SOLENOID OPERATOR Universal Valve Normally Closed 36A-J00-00-J XXP-XXX 36A-JSA-AE-J XXP-XXX 36A-JSF-AE-J XXP-XXX J XX P-XXX * Universal Valve Normally Open 36A-K00-00-J XXP-XXX 36A-KSA-AF-J XXP-XXX 36A-KSF-AF-J XXP-XXX Normally Closed Only 36A-L00-00-J XXP-XXX 36A-LSA-AE-J XXP-XXX 36A-LSF-AE-J XXP-XXX (-G) Add G for ground 33 34 36 3 37 38 5 67 69 44 46 4 47 48P XX Voltage X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) * Other options available, see page 317. Note : AC voltage requires connector with rectifier. 1 Non-locking recessed Locking recessed Example : Manifold base only : 36A-0SA-AE (Normally closed manifold base). End plate kit required (port size 1/4") : M-46003-01. FA FB FG Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 7 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.30 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult Factory 5.4 W.4 W 1.8 W Option : Spare parts : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 79443 DIMENSIONS 18.6 16.5 8.0 Dimensions shown are metric (mm) 8.0 4.0 Note: For Normally closed manifold the A port is plugged. For Normally open manifold the B port is plugged. 78.0 4.4 94.3 Ø 4.3 1/4" COMMONS 3.8.5 9.5 4.0 19.0 34. 5.5 79.0 95.5 3/4"-14 NPSM 8 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series 3/ 1/8" - 5/3 Pressed-in 0.3 C v tube receptacle OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure.. Patented solenoid develops high shifting forces. 3. Short stroke with high flow. 4. Higher forces result in lower wattages for given flow. 5. Powerful return spring. HOW TO ORDER Port size Valve less base 1/8 NPTF 5/3 tube receptacle SOLENOID OPERATOR Universal Valve Normally Closed 36A-J00-00-J XXP-XXX 36A-JSA-AG-J XXP-XXX 36A-JSF-AG-J XXP-XXX J XX P-XXX * Universal Valve Normally Open 36A-K00-00-J XXP-XXX 36A-KSA-AH-J XXP-XXX 36A-KSF-AH-J XXP-XXX Manifold base plug-in with pressure regulators Normally Closed Only 36A-L00-00-J XXP-XXX 36A-LSA-AG-J XXP-XXX 36A-LSF-AG-J XXP-XXX (-G) Add G for ground 33 34 36 3 37 38 5 67 69 44 46 4 47 48P XX Voltage X Manual operator XX AA DA DB DC DD 10 VAC (5.4W) 4 VDC (5.4W) 1 VDC (5.4W) 4 VDC (.4W) 1 VDC (.4W) * Other options available, see page 317. Note : AC voltage requires connector with rectifier. 1 Non-locking recessed Locking recessed FA FB FG Electrical connection Base plug-in Base plug-in with diode Base plug-in with rectifier 48 400 9 OPTIONS 36A-JSA-AG-JXX P-XXX G NC manifold & regulator with slotted stem adjustment 36A-KSA-AH-JXX P-XXX H NO manifold & regulator with slotted stem adjustment S NC manifold & regulator with locking slotted stem adjustment T NO manifold & regulator with locking slotted stem adjustment J NC manifold & regulator with knob adjustment K NO manifold & regulator with knob adjustment Note : All manifold bases are only available with a bottom cylinder port. Example : Manifold base only : 36A-0SA-AJ (Normally closed manifold base & regulator with knob). End plate kit required (port size 1/4") : M-46003-01. 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 9 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Compressed air, vacuum, inert gases Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1.8W : (0.0 C v ).4W : (0.0 C v ) 5.4W : (0.30 C v ) Class A continuous duty, # AWG x 1 base leads -15% to +10% of nominal voltage Consult Factory 5.4 W.4 W 1.8 W Option : Spare parts : BSPP threads Inlet isolator : 8501 Exhaust isolator : 850 Valve cover plate : M-4600 Tie rod (x) : 79443 DIMENSIONS 18.6 16.5 Dimensions shown are metric (mm) Note: For Normally closed manifold the A port is plugged. For Normally open manifold the B port is plugged. 78.0 3.8 4.4 94.3.5 9.5 1/8" GAGE PORT 69. Ø 4.3 1/4" COMMONS 7.9 4.0 5.5 19.0 34. 47.6 3.6 79.0 95.5 3/4"-14 NPSM 30 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 3 Function Port size Flow (Max) Individual mounting Series 3/ NO-NC 1/8 0.4 C v Sub-base non plug-in OPERATIONAL BENEFITS 1. 3-way valve with 4-way integral pilot.. 10 mm valve (stacks on 10.5 mm centers). 3. High flow (up to 0.4 C v ). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. 33 34 36 HOW TO ORDER Port size Valve less base 1/8 NPTF Note : Above codes are for side port. STANDARD SOLENOID OPERATOR Pilot air NO valve NC valve 10 1 10 1 3 1 3 1 Internal External Internal External 3B-BMA-000-GXXX-XXX 3B-BMB-000-GXXX-XXX 3B-BMA-CAL-GXXX-XXX 3B-BMB-CAM-GXXX-XXX 3B-AMA-000-GXXX-XXX 3B-AMB-000-GXXX-XXX 3B-AMA-CAL-GXXX-XXX 3B-AMB-CAM-GXXX-XXX G XXX-XXX * Universal valve 10 1 3 1 3B-GMB-000-GXXX-XXX 3B-GMB-CAM-GXXX-XXX 3 37 38 5 67 69 44 46 4 47 48P XX Voltage X Wire length X Manual operator XX AA DA DC DD DF 10 VAC (.5W) 4 VDC (1.0W) 4 VDC (1.8W) 4 VDC (,5W) 4 VDC (4.0W) OPTIONS Pilot/Base Configuration : 3B-XMX-XAX-GXXX-XXX A 18 B 4 C 36 Note : AC voltage requires connector with rectifier. * Other options available, see page 311. Latching solenoid also available, see page 41. With MAC JAC electrical connector washdown capability is possible. Consult factory for modification number. A Individual base Side port B Individual base Bottom port M Pilot exhaust muffled P Pilot exhaust piped (# 10-3) U Pilot exhaust to main exhaust (not available with external pilot) 1 Non-locking recessed Locking recessed BA BT GA GB GC GD GE GF GG GH KA KT KD Electrical connection Flying leads Flying leads with light w/diode w/mov w/led w/diode & LED w/mov & LED w/rectifier w/rectifier & LED Plug-in wire assy. Plug-in wire assy. with light Plug-in wire assy. with rectifier & light & ground 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 33 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 3 TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI 0 to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8 : (0.40 C v ) Class A wire (# AWG x 18), continuous duty -15% to +10% of nominal voltage 1.0 to 4.0 W Energize : 5 ms De-energize : 5 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) 6.0 4.5 X 1 67.4 79.1 Ø 4.3 49.9 37. 3 4.7 8.0 4.0 6.0 8.0 3.1 6.0 31.8 34 Consult Precautions page 37 before use, installation or service of MAC Valves..